Using AVISO satellite altimeter observations during 1993–2015 and a manual eddy detection method, a total of 276 anticyclonic rings and 242 cyclonic rings shed from the Kuroshio Extension(KE) were identified, and the...Using AVISO satellite altimeter observations during 1993–2015 and a manual eddy detection method, a total of 276 anticyclonic rings and 242 cyclonic rings shed from the Kuroshio Extension(KE) were identified, and their three-dimensional(3D) anomaly structures were further reconstructd based on the Argo float data and the Japan Agency for Marine-Earth Science and Technology(JAMSTEC) cruise and buoy data through an interpolation method. It is found that the cyclonic(anticyclonic) rings presented consistent negative(positive) anomalies of potential temperature;meanwhile the relevant maximum anomaly center became increasingly shallow for the cyclonic rings whereas it went deeper for the anticyclonic rings as the potential temperature anomaly decreased from the west to the east. The above deepening or shoaling trend is associated with the zonal change of the depth of the main thermocline. Moreover, the composite cold ring between 140° and 150°E was found to exhibit a double-core vertical structure due to the existence of mode water with low potential vorticity. Specifically, a relatively large negative(positive) salinity anomaly and a small positive(negative) one appeared for the composite cyclonic(anticyclonic) ring at the depth above and below 600 m, respectively. The underlying driving force for the temperature and salinity anomaly of the composite rings was also attempted, which varies depending on the intensity of the background current and the temperature and salinity fields in different areas of the KE region, and the rings’ influences on the temperature and salinity could reach deeper than 1 000 m on average.展开更多
We study the topological properties of magnon excitations in a wide class of three-dimensional (3D) honeycomb lattices with ferromagnetic ground states. It is found that they host nodal ring magnon excitations. Thes...We study the topological properties of magnon excitations in a wide class of three-dimensional (3D) honeycomb lattices with ferromagnetic ground states. It is found that they host nodal ring magnon excitations. These rings locate on the same plane in the momentum space. The nodal ring degeneracy can be lifted by the Dzyaloshinskii- Moriya interactions to form two Weyl points with opposite charges. We explicitly discuss these physics in the simplest 3D honeycomb lattice and the hyperhoneycomb lattice, and show drumhead and are surface states in the nodal ring and Weyl phases, respectively, due to the bulk-boundary correspondence.展开更多
The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who...The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology)by one surgeon at a single hospital were studied.The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule.Data collected included the operative duration,the blood loss,the damage of the important tissue,the biographic union and therecovery of the function after the operation.Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits.The scores of reduction and function were measured during follow-up.Results showed that the wounds of 30 patients were healed in the first stage,and there was no injury of important structures such as blood vessels and nerves.According to the Matta criteria,excellent effectiveness was obtained in 22 cases and good in 8 cases.According to the functional evaluation criteria of Majeed,excellent effectiveness was obtained in 21 cases and good in 9 cases.It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation,which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved,and better surgical result was finally achieved.展开更多
This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to De...This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to December 2016),in which the guiding template printed by the three-dimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis,was performed.Totally,4 males and 3 females were included in template group,aged from 38to 65years old (mean 50.86±8.90).Of them,5 had sacral fractures (3 with Denis type Ⅰ and 2 with type Ⅱ)and 2 the separation of sacroiliac joint.Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out.A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively.The time of each screw insertion,volume of intra-operative blood loss,and the exposure to X ray were analyzed and the Matta's radiological criteria were used to evaluate the reduction quality.The Majeed score was used to evaluate postoperative living quality.The visual analogue scale (VAS)was applied at different time points to judge pain relief of coccydynia.All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months,mean (16.57±2.44)months.Totally 9 sacroiliac screws for the S 1 and S2 vertebra were inserted in the 7 patients.The time length for each screw insertion ranged from 450 to 870 s,mean (690.56±135.68)s,and the number of times of exposure to X ray were 4 to 8,mean (5.78±1.20).The intra-operative blood loss ranged from 45to 120 mL,mean (75±23.32)mL.According to Matta's radiology criteria,the fracture and dislocation reduction were excellent in 6cases and good in 1.The pre-operative VAS score ranged from 5.2 to 8.1,mean (7.13±1.00).The average one-week/six-month post-operative VAS was (5.33±0.78)and (1.33±0.66),respectively (P<0.05 when compared with pre-operative VAS).The 12-month post-operative Majeed score ranged from 86 to 92,mean (90.29±2.21).The three-dimensional printed guiding template for sacroiliac screw insertion,which could significantly shorten the operation time,provide a satisfied outcome of the stabilization of the pelvic ring,and protect doctors and patients from X-ray exposure,might be a practical and valuable new clinical technique.展开更多
Semiconducting carbon nanotube (CNT) field effect transistor (FET) is attractive for constructing three-dimensional (3D) integrated circuits (ICs) because of its low-temperature processes and low power dissipation. Ho...Semiconducting carbon nanotube (CNT) field effect transistor (FET) is attractive for constructing three-dimensional (3D) integrated circuits (ICs) because of its low-temperature processes and low power dissipation. However, CNT based 3D ICs reported usually suffered from lower performance than that of monolayer CNT ICs. In this work, we develop a 3D IC technology through integrating multi-layer high performance CNT film FETs into one chip, and show that it promotes the operation speed of CNT based 3D ICs considerably. We also explore the advantage on ICs of 3D architecture, which brings 38% improvement on speed over two-dimensional (2D) one. Specially, we demonstrate the fabrication of 3D five-stage ring-oscillator circuits with an oscillation frequency of up to 680 MHz and stage delay of 0.15 ns, which represents the highest speed of 3D CNT-based ICs.展开更多
A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in uns...A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei.The CAT-TPC consists of an electronic field cage,double-thick gas-electron-multiplier foils,a general-purpose digital data acquisition system,and a newly developed two-dimensional strip-readout structure.The CAT-TPC was operated using a^(4)He(96%)+CO_(2)(4%)gas mixture at 400 mbar.The working gas also serves as an active target for tracking charged particles.The overall performance of the CAT-TPC was evaluated using a collimated a-particle source.A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction.Threedimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree.展开更多
基金The National Key Research and Development Program of China under contract No. 2016YFC1402607Scientific Research Foundation of Third Institude of Oceanography, Ministry of Nature Resources under contract Nos 2017012 and 2018001Global Change and Air-Sea Interaction Program under contract Nos GASI-IPOVAI-02 and GASI-IPOVAI-03.
文摘Using AVISO satellite altimeter observations during 1993–2015 and a manual eddy detection method, a total of 276 anticyclonic rings and 242 cyclonic rings shed from the Kuroshio Extension(KE) were identified, and their three-dimensional(3D) anomaly structures were further reconstructd based on the Argo float data and the Japan Agency for Marine-Earth Science and Technology(JAMSTEC) cruise and buoy data through an interpolation method. It is found that the cyclonic(anticyclonic) rings presented consistent negative(positive) anomalies of potential temperature;meanwhile the relevant maximum anomaly center became increasingly shallow for the cyclonic rings whereas it went deeper for the anticyclonic rings as the potential temperature anomaly decreased from the west to the east. The above deepening or shoaling trend is associated with the zonal change of the depth of the main thermocline. Moreover, the composite cold ring between 140° and 150°E was found to exhibit a double-core vertical structure due to the existence of mode water with low potential vorticity. Specifically, a relatively large negative(positive) salinity anomaly and a small positive(negative) one appeared for the composite cyclonic(anticyclonic) ring at the depth above and below 600 m, respectively. The underlying driving force for the temperature and salinity anomaly of the composite rings was also attempted, which varies depending on the intensity of the background current and the temperature and salinity fields in different areas of the KE region, and the rings’ influences on the temperature and salinity could reach deeper than 1 000 m on average.
基金Supported by the National Basic Research Program of China under Grant No 2015CB921300the National Natural Science Foundation of China under Grant No 11334012the Strategic Priority Research Program of Chinese Academy of Sciences under Grant No XDB07000000
文摘We study the topological properties of magnon excitations in a wide class of three-dimensional (3D) honeycomb lattices with ferromagnetic ground states. It is found that they host nodal ring magnon excitations. These rings locate on the same plane in the momentum space. The nodal ring degeneracy can be lifted by the Dzyaloshinskii- Moriya interactions to form two Weyl points with opposite charges. We explicitly discuss these physics in the simplest 3D honeycomb lattice and the hyperhoneycomb lattice, and show drumhead and are surface states in the nodal ring and Weyl phases, respectively, due to the bulk-boundary correspondence.
文摘The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology)by one surgeon at a single hospital were studied.The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule.Data collected included the operative duration,the blood loss,the damage of the important tissue,the biographic union and therecovery of the function after the operation.Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits.The scores of reduction and function were measured during follow-up.Results showed that the wounds of 30 patients were healed in the first stage,and there was no injury of important structures such as blood vessels and nerves.According to the Matta criteria,excellent effectiveness was obtained in 22 cases and good in 8 cases.According to the functional evaluation criteria of Majeed,excellent effectiveness was obtained in 21 cases and good in 9 cases.It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation,which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved,and better surgical result was finally achieved.
文摘This study is aimed to explore the clinical application of the guiding template designed by three-dimensional printing data for the insertion of sacroiliac screws.A retrospective study of 7 cases (from July 2016 to December 2016),in which the guiding template printed by the three-dimensional printing technique was used for the insertion of sacroiliac screws of patients with posterior ring injuries of pelvis,was performed.Totally,4 males and 3 females were included in template group,aged from 38to 65years old (mean 50.86±8.90).Of them,5 had sacral fractures (3 with Denis type Ⅰ and 2 with type Ⅱ)and 2 the separation of sacroiliac joint.Guiding templates were firstly made by the three-dimensional printing technique based on the pre-operative CT data. Surgical operations for the stabilization of pelvic ring by applying the guiding templates were carried out.A group of 8 patients with sacroiliac injuries treated by percutaneous sacroiliac screws were analyzed as a control group retrospectively.The time of each screw insertion,volume of intra-operative blood loss,and the exposure to X ray were analyzed and the Matta's radiological criteria were used to evaluate the reduction quality.The Majeed score was used to evaluate postoperative living quality.The visual analogue scale (VAS)was applied at different time points to judge pain relief of coccydynia.All the 7 patients in the template group were closely followed up radiographically and clinically for 14 to 20 months,mean (16.57±2.44)months.Totally 9 sacroiliac screws for the S 1 and S2 vertebra were inserted in the 7 patients.The time length for each screw insertion ranged from 450 to 870 s,mean (690.56±135.68)s,and the number of times of exposure to X ray were 4 to 8,mean (5.78±1.20).The intra-operative blood loss ranged from 45to 120 mL,mean (75±23.32)mL.According to Matta's radiology criteria,the fracture and dislocation reduction were excellent in 6cases and good in 1.The pre-operative VAS score ranged from 5.2 to 8.1,mean (7.13±1.00).The average one-week/six-month post-operative VAS was (5.33±0.78)and (1.33±0.66),respectively (P<0.05 when compared with pre-operative VAS).The 12-month post-operative Majeed score ranged from 86 to 92,mean (90.29±2.21).The three-dimensional printed guiding template for sacroiliac screw insertion,which could significantly shorten the operation time,provide a satisfied outcome of the stabilization of the pelvic ring,and protect doctors and patients from X-ray exposure,might be a practical and valuable new clinical technique.
基金supported by the National Key Research & Development Program (No.2016YFA0201901)the National Natural Science Foundation of China (Nos.61621061,61427901 and 61888102)the Beijing Municipal Science and Technology Commission (No.D171100006617002 1-2).
文摘Semiconducting carbon nanotube (CNT) field effect transistor (FET) is attractive for constructing three-dimensional (3D) integrated circuits (ICs) because of its low-temperature processes and low power dissipation. However, CNT based 3D ICs reported usually suffered from lower performance than that of monolayer CNT ICs. In this work, we develop a 3D IC technology through integrating multi-layer high performance CNT film FETs into one chip, and show that it promotes the operation speed of CNT based 3D ICs considerably. We also explore the advantage on ICs of 3D architecture, which brings 38% improvement on speed over two-dimensional (2D) one. Specially, we demonstrate the fabrication of 3D five-stage ring-oscillator circuits with an oscillation frequency of up to 680 MHz and stage delay of 0.15 ns, which represents the highest speed of 3D CNT-based ICs.
基金supported by the National Key R&D Program of China(No.2018YFA0404403)the National Natural Science Foundation of China(Nos.U1967201,11875074,11875073,and 11961141003)the State Key Laboratory of Nuclear Physics and Technology,PKU(No.NPT2020KFY06)。
文摘A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei.The CAT-TPC consists of an electronic field cage,double-thick gas-electron-multiplier foils,a general-purpose digital data acquisition system,and a newly developed two-dimensional strip-readout structure.The CAT-TPC was operated using a^(4)He(96%)+CO_(2)(4%)gas mixture at 400 mbar.The working gas also serves as an active target for tracking charged particles.The overall performance of the CAT-TPC was evaluated using a collimated a-particle source.A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction.Threedimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree.