期刊文献+
共找到1,478篇文章
< 1 2 74 >
每页显示 20 50 100
A method for phase reconstruction in optical three-dimensional shape measurement
1
作者 乔闹生 贺志 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第9期267-270,共4页
In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that ... In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that lie in the x-axis direction of the phase domain are given. Partial derivatives of the phase function in the x- and y-axis directions are obtained with a phase-shifting mechanism, the origin of which is analysed. Furthermore, to avoid phase unwrapping in the phase reconstruction, we derive the gradient of the phase function and perform a two-dimensional integral along the x- and y-axis directions. The reconstructed phase can be obtained directly by performing numerical integration, and thus it is of great convenience for phase reconstruction. Finally, the results of numerical simulations and practical experiments verify the correctness of the proposed method. 展开更多
关键词 phase reconstruction optical three-dimensional shape measurement measurement pre-cision
下载PDF
Multi-objective strategy to optimize dithering technique for high-quality three-dimensional shape measurement 被引量:2
2
作者 Ning Cai Zhe-Bo Chen +1 位作者 Xiang-Qun Cao Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期381-386,共6页
Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the pro... Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the problem with the latter is that it cannot enhance phase quality directly nor efficiently. In this paper, we present a multi-objective optimization framework for three-dimensional(3D) measurement by utilizing binary defocusing technique. Moreover, a binary patch optimization technique is used to solve the time-consuming issue of genetic algorithm. It is demonstrated that the presented technique consistently obtains significant phase performance improvement under various defocusing amounts. 展开更多
关键词 three-dimensional(3D) shape measurement MULTI-OBJECTIVE dithering GENETIC algorithm
下载PDF
Dual-frequency fringe for improving measurement accuracy of three-dimensional shape measurement 被引量:2
3
作者 Zixiao Miao Qican Zhang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2021年第10期81-87,共7页
A new phase unwrapping method based on dual-frequency fringe is proposed to improve both high accuracy and large measurement range of three-dimensional shape measurement by synthesizing the projected dual-frequency fr... A new phase unwrapping method based on dual-frequency fringe is proposed to improve both high accuracy and large measurement range of three-dimensional shape measurement by synthesizing the projected dual-frequency fringes obtaining higher and lower frequencies.The lower-frequency one is their phase difference,which can help unwrap the wrapped phase of the higher-frequency one from their phase sum.In addition,the relationship between the measuring accuracy and the frequencies of the projected fringes is studied to guide the frequency selection in actual measurement.It is found that the closer the two frequencies are,the higher the measurement accuracy will be.The computer simulation and experiment results show the viability of this method. 展开更多
关键词 fringe projection 3D shape measurement dual frequency phase shifting phase sum
原文传递
Three-Dimensional Measurement and Reconstruction of Fabric Drape Shape 被引量:1
4
作者 沈毅 尹红媛 刘玄木 《Journal of Donghua University(English Edition)》 EI CAS 2007年第1期39-42,共4页
This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes... This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics. 展开更多
关键词 fabric drape non-contact measurement structurelight image process three-dimension reconstruction.
下载PDF
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
5
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
A fast and precise three-dimensional measurement system based on multiple parallel line lasers
6
作者 Yao Wang Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期276-284,共9页
This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on... This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm. 展开更多
关键词 three-dimensional shape measurement multiple parallel line lasers fast and precise measurement parameter calibration
下载PDF
Volumetric measurement techniques for assessment of cutaneous neurofibromas:A review
7
作者 Xinyu Wang Jiayi Xu +2 位作者 Yun Zhu Chengjiang Wei Zhichao Wang 《Chinese Journal of Plastic and Reconstructive Surgery》 2024年第2期83-86,共4页
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc... Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain. 展开更多
关键词 Cutaneous neurofibroma Tumor volume measurement Vernier caliper Ultrasound Computed tomography Magnetic resonance imaging three-dimensional scanning imaging
下载PDF
Evaluating the contribution of satellite measurements to the reconstruction of three-dimensional ocean temperature fields in combination with Argo profiles 被引量:1
8
作者 Jian Chen Hengqian Yan +3 位作者 Senliang Bao Xindong Cui Chengzu Bai Huizan Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第2期65-79,共15页
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ... Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics). 展开更多
关键词 satellite measurements ARGO three-dimensional reconstruction ocean temperature
下载PDF
First application of large reactivity measurement through rod drop based on three-dimensional space–time dynamics
9
作者 Wen-Cong Wang Li-Yuan Huang +6 位作者 Cai-Xue Liu Han Feng Jiang Niu Qi-Dong Dai Guo-En Fu Lin-Feng Yang Ming-Chang Wu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第2期11-23,共13页
Abstract Reactivity measurement is an essential part of a zero-power physics test,which is critical to reactor design and development.The rod drop experimental technique is used to measure the control rod worth in a z... Abstract Reactivity measurement is an essential part of a zero-power physics test,which is critical to reactor design and development.The rod drop experimental technique is used to measure the control rod worth in a zero-power physics test.The conventional rod drop experimental technique is limited by the spatial effect and the difference between the calculated static reactivity and measured dynamic reactivity;thus,the method must be improved.In this study,a modified rod drop experimental technique that constrains the detector neutron flux shape function based on three-dimensional space–time dynamics to reduce the reactivity perturbation and a new method for calculating the detector neutron flux shape function are proposed.Correction factors were determined using Monte Carlo N-particle transport code and transient analysis code for a pressurized water reactor at the Ulsan National Institute of Science and Technology and Xi’an Jiaotong University,and a large reactivity of over 2000 pcm was measured using the modified technique.This research evaluated the modified technique accuracy,studied the influence of the correction factors on the modification,and investigated the effect of constraining the shape function on the reactivity perturbation reduction caused by the difference between the calculated neutron flux and true value,using the new method to calculate the shape function of the detector neutron flux and avoiding the neutron detector response function(weighting factor)calculation. 展开更多
关键词 Large reactivity measurement Rod drop technique Space-time dynamics Constrained shape function Monte Carlo N-particle
下载PDF
Three-Dimensional Velocity Distribution Measurement Using Ultrasonic Velocity Profiler with Developed Transducer
10
作者 Naruki Shoji Hiroshige Kikura +1 位作者 Hideharu Takahashi Wongsakorn Wongsaroj 《Journal of Flow Control, Measurement & Visualization》 2022年第1期32-55,共24页
This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with u... This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with unique 5-element configuration</span></span><span style="white-space:normal;"><span style="font-family:;" "="">, with all five elements acting as transmitters and four elements as receivers. The receivers are designed to reduce the amount of uncertainty. As the fluid moves through this setup, four Doppler frequencies are obtained. The multi-dimensional velocity information along the measurement line can be reconstructed. The transducer has a compact geometry suitable for a wide range of applications, including narrow flow areas. The transducer’s basic frequency and sound pressure are selected and evaluated to be compatible with the application. First, to confirm the measurement ability, the measurement of the developed system in two-dimensional flow is validated by comparing it to the theoretical data. The uncertainty of measurement was within 15%. Second, the three-dimensional measurement in turbulent and swirling flow is proved experimentally to check the applicability of the proposed technique.</span></span> 展开更多
关键词 Doppler Frequency Liquid Velocity three-dimensional measurement Transducer Design ULTRASONIC
下载PDF
Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology
11
作者 胡永成 《外科研究与新技术》 2011年第2期125-125,共1页
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer... Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the 展开更多
关键词 BONE Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology CT
下载PDF
Three-Dimensional Analytical Modeling of Axial-Flux Permanent Magnet Drivers
12
作者 Wenhui Li Dazhi Wang +3 位作者 Shuo Cao Deshan Kong Sihan Wang Zhong Hua 《Computers, Materials & Continua》 SCIE EI 2023年第4期259-276,共18页
In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare co... In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare comprehensively considered, and the governing equations are solved bysimplifying the boundary conditions. The axial magnetization of the sectorshapedpermanent magnets is accurately described in an algebraic form bythe parameters, which makes the physical meaning more explicit than thepurely mathematical expression in general series forms. The parameters of theBessel function are determined simply and the magnetic field distribution ofpermanent magnets and the air-gap is solved. Furthermore, the field solutionsare completely analytical, which provides convenience and satisfactoryaccuracy for modeling a series of electromagnetic performance parameters,such as the axial electromagnetic force density, axial electromagnetic force,and electromagnetic torque. The correctness and accuracy of the analyticalmodels are fully verified by three-dimensional finite element simulations and a15 kW prototype and the results of calculations, simulations, and experimentsunder three methods are highly consistent. The influence of several designparameters on magnetic field distribution and performance is studied and discussed.The results indicate that the modeling method proposed in this papercan calculate the magnetic field distribution and performance accurately andrapidly, which affords an important reference for the design and optimizationof axial-flux permanent magnet drivers. 展开更多
关键词 three-dimensional analytical modeling cylindrical coordinates magnetic field distribution parameter sensitivity analysis performance measurement
下载PDF
Development of a Three-Dimensional Measuring System for Neonates' Head and Facial Morphology 被引量:1
13
作者 邓咏梅 易洁伦 +2 位作者 郭绮莲 黄小珍 吴新培 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期309-312,共4页
A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch... A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch protector for neonates, particularly whoa they are exposed to bright lights such as phototherapy light. Measurements obtained by the system are evaluated and validated against data obtained from optical scanning. Results show that the photogrammetric system meets the requirements of measuring accuracy and safety for neonate in the neonatal units. 展开更多
关键词 close-range photogrammetry (CRP) three-dimensional measurement NEONATES head and facialmorphology
下载PDF
Surface shape detection methods for large radio telescopes
14
作者 Zhengxiong Sun Jinqing Wang +7 位作者 Linfeng Yu Yongchen Jiang Zheng Lou Yongbin Jiang Rongbin Zhao Qian Ye Qinghui Liu Guangli Wang 《Astronomical Techniques and Instruments》 CSCD 2024年第5期275-283,共9页
The surface accuracy of a radio telescope is directly related to its operational efficiency and detection sensitivity.This is crucial under high-frequency observation conditions,where surface shape errors need to be c... The surface accuracy of a radio telescope is directly related to its operational efficiency and detection sensitivity.This is crucial under high-frequency observation conditions,where surface shape errors need to be controlled to within 1/16 of the working wavelength.In addition,the primary reflector of large radio telescopes is subject to dynamic deformation,caused by factors such as gravity and thermal effects.This paper presents a method for detecting the surface shape of radio telescopes using radio interferometry techniques combined with active reflector adjustment technology.This enables accurate assessment and correction of surface errors,ensuring the electrical performance of the radio telescope.This study investigates the practical applications of high-precision measurement techniques,such as microwave holography,out-of-focus holography,and wavefront distortion methods at the Tianma 65 m radio telescope(TMRT).Furthermore,the study presents the construction method of gravity models at different elevation angles and demonstrates the efficacy of the active reflector model.The results of the measurements indicate that the application of these methods to the TMRT has led to a notable enhancement of the accuracy of the primary reflector and a substantial improvement in efficiency in the Q-band.Through a process of iterative measurements and adjustments,the surface shape error is ultimately reduced to 0.28 mm root mean square(RMS). 展开更多
关键词 Radio telescope Holographic measurements Surface shape measurements Antenna efficiency
下载PDF
Balanced Functional Maps for Three-Dimensional Non-Rigid Shape Registration
15
作者 Xu-Peng Wang Hang Lei +1 位作者 Yan Liu Nan Sang 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第4期369-378,共10页
Three-dimensional(3D)shape registration is a challenging problem,especially for shapes under non-rigid transformations.In this paper,a 3D non-rigid shape registration method is proposed,called balanced functional maps... Three-dimensional(3D)shape registration is a challenging problem,especially for shapes under non-rigid transformations.In this paper,a 3D non-rigid shape registration method is proposed,called balanced functional maps(BFM).The BFM algorithm generalizes the point-based correspondence to functions.By choosing the Laplace-Beltrami eigenfunctions as the function basis,the transformations between shapes can be represented by the functional map(FM)matrix.In addition,many constraints on shape registration,such as the feature descriptor,keypoint,and salient region correspondence,can be formulated linearly using the matrix.By bi-directionally searching for the nearest neighbors of points’indicator functions in the function space,the point-based correspondence can be derived from FMs.We conducted several experiments on the Topology and Orchestration Specification for Cloud Applications(TOSCA)dataset and the Shape Completion and Animation of People(SCAPE)dataset.Experimental results show that the proposed BFM algorithm is effective and has superior performance than the state-of-the-art methods on both datasets. 展开更多
关键词 Functional map(FM) Laplace-Beltrami operator shape registration three-dimensional(3D)non-rigid shape.
下载PDF
Inspection of Complex Internal Surface Shape with Fiber-optic Sensor II: for Specular Tilted Surface Measurement
16
作者 赵勇 Li +2 位作者 Pengsheng PU Zhaobang 《High Technology Letters》 EI CAS 2001年第2期27-30,共4页
Complex surface shape measurement has been a focus topic in the CAD/CAM field. A popular method for measuring dimensional information is using a 3D coordinate measuring machine (CMM)with a touch trigger probe. The mea... Complex surface shape measurement has been a focus topic in the CAD/CAM field. A popular method for measuring dimensional information is using a 3D coordinate measuring machine (CMM)with a touch trigger probe. The measurement set up with CMM, however, is a time consuming task and the accuracy of the measurement deteriorates as the speed of measurement increase. Non-contact measurement is favored since high speed measurement can be achieved and problems with vibration and friction can be eliminated. Although much research has been conducted in non-contact measurement using image capturing and processing schemes, accuracy is poor and measurement is limited. Some optical technologies developed provide a good accuracy but the dynamic range and versatility is very limited. A novel fiber-optic sensor used for the inspection of complex internal contours is presented in this paper, which is able to measure a surface shape in a non-contact manner with high accuracy and high speed, and is compact and flexible to be incorporated into a CMM. Modulation functions for tilted surface shape measurement, based on the Gaussian distribution of the emitting beam from single-mode fiber (SMF), were derived for specular reflection. The feasibility of the proposed measurement principle was verified by simulations. 展开更多
关键词 Fiber-optic sensor shape inspection Internal contour Non-contact measurement Gaussian statistics
下载PDF
Diameters and form of skull base foramen ovale measured by three-dimensional spiral CT thin-slice scan in healthy adults
17
作者 Xiaohua Chen Fengxian Deng +1 位作者 Shuhang Wei Tingsong Fang 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期343-346,共4页
BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia... BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults. 展开更多
关键词 Diameters and form of skull base foramen ovale measured by three-dimensional spiral CT thin-slice scan in healthy adults CT base
下载PDF
New Approach for 3D Shape Measurement Based on Color-Coded Fringe and Neural Network
18
作者 QIN Da-hui, SHI Yu-sheng, WANG Cong-jun , LI Zhong-wei (State Key Laboratory of Material Processing and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan 430074, China) 《Computer Aided Drafting,Design and Manufacturing》 2008年第2期50-56,共7页
A new 3D surface contouring and ranging system based on digital fringe projection and phase shifting technique is presented. Using the phase-shift technique, points cloud with high spatial resolution and limited accur... A new 3D surface contouring and ranging system based on digital fringe projection and phase shifting technique is presented. Using the phase-shift technique, points cloud with high spatial resolution and limited accuracy can be generated. Stereo-pair images obtained from two cameras can be used to compute 3D world coordinates of a point using traditional active triangulation approach, yet the camera calibration is crucial. Neural network is a well-known approach to approximate a nonlinear system without an explicit physical model, in this work it is used to train the stereo vision application system to calculating 3D world coordinates such that the camera calibration can be bypassed. The training set for neural network consists of a variety of stereo-pair images and the corresponding 3D world coordinates. The picture elements correspondence problem is solved by using projected color-coded fringes with different orientations. Color imbalance is completely eliminated by the new color-coded method. Once the high accuracy correspondence of 2D images with 3D points is acquired, high precision 3D points cloud can be recognized by the well trained net. The obvious advantage of this approach is that high spatial resolution can be obtained by the phase-shifting technique and high accuracy 3D object point coordinates are achieved by the well trained net which is independent of the camera model works for any type of camera. Some experiments verified the performance of the method. 展开更多
关键词 3D shape measurement color-coded fringe neural network correspondence problem color imbalance
下载PDF
Development of an In-Situ Laser Machining System Using a Three-Dimensional Galvanometer Scanner 被引量:6
19
作者 Xiao Li Bin Liu +3 位作者 Xuesong Mei Wenjun Wang Xiaodong Wang Xun Li 《Engineering》 SCIE EI 2020年第1期68-76,共9页
In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structur... In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs. 展开更多
关键词 In-situ laser machining three-dimensional galvanometer scanner Line structured light three-dimensional measurement
下载PDF
Optimized dithering technique in frequency domain for high-quality three-dimensional depth data acquisition 被引量:2
20
作者 Ning Cai Zhe-Bo Chen +1 位作者 Xiang-Qun Cao Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第8期124-131,共8页
On the basis of the objective functions,dithering optimization techniques can be divided into the intensity-based optimization technique and the phase-based optimization technique.However,both types of techniques are ... On the basis of the objective functions,dithering optimization techniques can be divided into the intensity-based optimization technique and the phase-based optimization technique.However,both types of techniques are spatial-domain optimization techniques,while their measurement performances are essentially determined by the harmonic components in the frequency domain.In this paper,a novel genetic optimization technique in the frequency domain is proposed for highquality fringe generation.In addition,to handle the time-consuming difficulty of genetic algorithm(GA),we first optimize a binary patch,then join the optimal binary patches together according to periodicity and symmetry so as to generate a full-size pattern.It is verified that the proposed technique can significantly enhance the measured performance and ensure the robustness to various amounts of defocusing. 展开更多
关键词 FRINGE generation GENETIC algorithm frequency DOMAIN 3D shape measurement
下载PDF
上一页 1 2 74 下一页 到第
使用帮助 返回顶部