期刊文献+
共找到18篇文章
< 1 >
每页显示 20 50 100
Soft-switching PWM boost full-bridge converter 被引量:4
1
作者 周林泉 阮新波 《Journal of Southeast University(English Edition)》 EI CAS 2003年第3期250-255,共6页
This paper proposes a family of PWM modulation strategies for boostfull-bridge (FB) converters. The modulation strategies can be classified into two kinds according tothe turn-on sequence of the diagonal switches. The... This paper proposes a family of PWM modulation strategies for boostfull-bridge (FB) converters. The modulation strategies can be classified into two kinds according tothe turn-on sequence of the diagonal switches. The concept of leading switches and lagging switchesis introduced to realize soft-switching. According to the soft-switching realized by the leadingswitches and the lagging switches, two kinds of soft-switching techniques for PWM boost FBconverters yield: zero-current-switching (ZCS) and zero-current and zero-voltage-switching (ZCZVS).Simulation results verify the analysis. 展开更多
关键词 PWM BOOST full-bridge converters ZERO-CURRENT-SWITCHING ZERO-VOLTAGE-SWITCHING
下载PDF
Design considerations for the improved current-doubler-rectifier ZVS PWM full-bridge converter
2
作者 王建冈 阮新波 陈乾宏 《Journal of Southeast University(English Edition)》 EI CAS 2003年第3期256-263,共8页
The improved current-doubler-rectifier zero-voltage-switching PWM full-bridge converter (CDR ZVS PWM FB converter) achieves ZVS for the switches in a wide load range with the use of the energy stored in the output fil... The improved current-doubler-rectifier zero-voltage-switching PWM full-bridge converter (CDR ZVS PWM FB converter) achieves ZVS for the switches in a wide load range with the use of the energy stored in the output filter inductances, and the rectifier diodes commute naturally, therefore no oscillation and voltage spike occurs. The transformer needs no special manufacture method to limit the leakage inductance. The ZVS achievement and the design considerations for the output filter inductances and the blocking capacitor are discussed for the improved CDR ZVS PWM FB converter. A 540 W prototype converter is built in the lab to verify the operational principle and design considerations for the improved converter, the experimental results are also included. 展开更多
关键词 full-bridge converter ZERO-VOLTAGE-SWITCHING pulse-width-modulation current-doubler-rectifier
下载PDF
Application research on ZVZCS full-bridge converter technique
3
作者 贲洪奇 杨世彦 +1 位作者 原树斌 赵俊宝 《China Welding》 EI CAS 2005年第2期113-116,共4页
Based on ZVZCS (zero voltage zero current switching) full bridge converter technique, a novel inverter welding power supply is designed, in which the secondary side of the transformer adopts passive clamping circuit... Based on ZVZCS (zero voltage zero current switching) full bridge converter technique, a novel inverter welding power supply is designed, in which the secondary side of the transformer adopts passive clamping circuit to reduce voltage stress of rectifying components. This supply can realize power switches ZVS (zero voltage switching ) or ZCS (zero current switching) within a very wide range of load; Only through setting up blocking capacitor in the primary side of transformer, the power transformer's bias in the full-bridge converter is suppressed and the primary current can be reset easily. In addition, how to calculate the blocking capacitor and its influence to power supply performance are also subjects discussed in this paper. 展开更多
关键词 zero voltage switching zero current switching full-bridge converter blocking capacitor
下载PDF
The Implementation of a High Efficiency Full-Bridge Converter
4
作者 Joy Iong-Zong Chen 《Engineering(科研)》 2011年第4期331-339,共9页
A high efficiency full-bridge converter is investigated and implemented in this paper. The measured data result from the other converter implemented by IC UCC3895 is to compare with that of the previous converter. Thi... A high efficiency full-bridge converter is investigated and implemented in this paper. The measured data result from the other converter implemented by IC UCC3895 is to compare with that of the previous converter. This full-bridge converter proposed and implemented converter can obtain about 96% power efficiency in conversion procedure when compared with that of 90%, which were ever published by the conventional techniques. Apart from, the L-C resonance circuits were developed and embedded into the popular PWM (pulse width modulation) power converter, which is referred as the soft-switching, so as to down sizing the volume of the IC which can totally reduces the power losses caused in the duration of a semi-con- ductor switching. 展开更多
关键词 High Efficiency full-bridge converter SWITCHING LOSSES SYNCHRONIZATION FILTER
下载PDF
Model predictive control of three-level active front-end converter with low switching frequency
5
作者 YANG Li WANG Lang-zhu +1 位作者 FENG Bo WANG Hong-lin 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第2期153-159,共7页
In medium voltage-high power(MV-HP)applications,the high switching frequency of power converter will result in unnecessary energy losses,which directly affect efficiency.To resolve this issue,a novel finite control se... In medium voltage-high power(MV-HP)applications,the high switching frequency of power converter will result in unnecessary energy losses,which directly affect efficiency.To resolve this issue,a novel finite control set-model predictive control(FCS-MPC)with low switching frequency for three-level neutral point clamped-active front-end converters(NPC-AFEs)is proposed.With this approach,the prediction model of three-level NPC-AFEs is established inα-βreference frame,and the control objective of low average switching frequency is introduced into a cost function.The proposed method not only achieves the desired control performance under low switching frequency,but also performs the efficient operation for the three-level NPC-AFEs.The simulation results are provided to verify the effectiveness of proposed control scheme. 展开更多
关键词 finite control set-model predictive control(FCS-MPC) three-level neutral point clamped active front-end converters(NPC-AFEs) switching frequency
下载PDF
Comprehensive predictive control of neutral-point voltage balancing for back-to-back three-level NPC converters
6
作者 范必双 谭冠政 +1 位作者 樊绍胜 叶吉祥 《Journal of Central South University》 SCIE EI CAS 2014年第11期4210-4219,共10页
A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for th... A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one. 展开更多
关键词 back-to-back converter three-level converter neutral-point balancing comprehensive control predictive control
下载PDF
An Improved Modulation Strategy for Single-phase Three-level Neutral-point-clamped Converter in Critical Conduction Mode
7
作者 Ning Li Yujie Cao +4 位作者 Xiaokang Liu Yan Zhang Ruotong Wang Lin Jiang Xiao-Ping Zhang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期981-990,共10页
Two-level totem-pole power factor correction(PFC)converters in critical conduction mode(CRM)suffer from the wide regulation range of switching frequency.Besides,in highfrequency applications,the number of switching ti... Two-level totem-pole power factor correction(PFC)converters in critical conduction mode(CRM)suffer from the wide regulation range of switching frequency.Besides,in highfrequency applications,the number of switching times increases,resulting in significant switching losses.To solve these issues,this paper proposes an improved modulation strategy for the single-phase three-level neutral-point-clamped(NPC)converter in CRM with PFC.By optimizing the discharging strategy and switching state sequence,the switching frequency and its variation range have been efficiently reduced.The detailed performance analysis is also presented regarding the switching frequency,the average switching times,and the effect of voltage gain.A 2 k W prototype is built to verify the effectiveness of the proposed modulation strategy and analysis results.Compared with the totem-pole PFC converter,the switching frequency regulation range of the three-level PFC converter is reduced by 36.48%and the average switching times is reduced by 45.10%.The experimental result also shows a 1.2%higher efficiency for the three-level PFC converter in the full load range. 展开更多
关键词 Critical conduction mode(CRM) on-board charger switching frequency range switching times power factor correction(PFC) three-level converter
原文传递
Research on Phase-Shifted Full-Bridge Circuit Based on Frequency and Phase-Shift Synthesis Modulation Strategy
8
作者 Mingda Jiang Yanbo Che +2 位作者 Hongfeng Li Muhammad Ishaq Chao Xing 《Energy Engineering》 EI 2022年第2期699-721,共23页
The full-bridge converters usually use transformer leakage inductance and parallel resonant capacitors to achieve smooth current commutation and soft switching functions,which can easily cause problems such as energy ... The full-bridge converters usually use transformer leakage inductance and parallel resonant capacitors to achieve smooth current commutation and soft switching functions,which can easily cause problems such as energy leakage and significant duty cycle loss.This paper designs a novel full-bridge zero-current(FB-ZCS)converter with series resonant capacitors and proposes a frequency and phase-shift synthesis modulation(FPSSM)control strategy based on this topology.Compared with the traditional parallel resonant capacitor circuit,the passive components used are significantly reduced,the structure is simple,and there is only a slight energy loss.By controlling the charging time of the capacitor,it can be achieved without additional switches or auxiliary circuits.The automatic control of capacitor energy based on input current addresses the low efficiency of the traditional control strategies.This paper introduces its principle in detail and verifies it through simulation.Finally,an experimental prototype was built further to demonstrate the feasibility of the theory through experiments.The module can be applied to a photovoltaic DC collection system using input parallel output series(IPOS)cascade to provide a new topology for large-scale,long-distance DC transmission. 展开更多
关键词 full-bridge converter frequency and phase-shift synthesis modulation(FPSSM) photovoltaic DC collection system control strategy
下载PDF
DC Traction Power Supply System Based on Modular Multilevel Converter Suitable for Energy Feeding and De-icing 被引量:1
9
作者 Lingxi Hou Shuqing Zhang +4 位作者 Yingdong Wei Xiaoqian Li Qirong Jiang Mingrui Li Weirui Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期649-659,共11页
A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel convert... A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel converter (MMC). The FBSM-MMC is a novel type of voltage source converter (VSC) and can directly control the output DC voltage and conduct bipolar currents, thus flexibly controlling the power flow of the urban rail transit catenary. The proposed topology can overcome the inherent disadvantages of the output voltage drop in the diode rectifier units, increase the power supply distance and reduce the number of traction substations. The flexible DC technology can coordinate multiple FBSM-MMCs in a wide area and jointly complete the bidirectional control of catenary power flow during the operation of the electric locomotive, so as to realize the local consumption and optimal utilization of the recovered braking energy of the train. In addition, the FBSM-MMCs can also adjust the output current when the locomotive is out of service to prevent the catenary from icing in winter. The working modes of the proposed topology are illustrated in detail and the control strategy is specially designed for normal locomotive operations and catenary de-icing. Simulation cases conducted by PSCAD/EMTDC validate the proposed topology and its control strategy. 展开更多
关键词 DC traction power supply system de-icing for catenary energy feeding modular multilevel converter based on full-bridge submodules(FBSM-MMC) urban rail transit
原文传递
High Power Density Three-Level Three-Phase AC-DC 48 V Power Supply
10
作者 Alessandro Lidozzi Andrea Romanelli Luca Solero 《Journal of Energy and Power Engineering》 2012年第10期1624-1634,共11页
International standards impose several constraints concerning the electric power quality and require that the harmonic content of the line current of grid connected equipment is below assigned limits; for this reason,... International standards impose several constraints concerning the electric power quality and require that the harmonic content of the line current of grid connected equipment is below assigned limits; for this reason, operating of AC-DC converters with high power factor and low line current distortion has become essential. In this paper, the prototypal realization of a three-phase AC-DC 48 V power electronic converter for telecom system supplying is described and experimental testing results are discussed. The main constraints in the power supply design are the required power density of about 900 W per dm3 as well as the absence of the neutral wire in the supply grid. The carried out investigation is focused on three-level power converter configurations which are considered in order to reduce voltage rating of power switches. As a result of the reduced voltage, low on-resistance metal-oxide-semiconductor field effect transistors can be used in the power stage, solution which allows to achieve improved efficiency as well as increased switching frequency with respect to the insulated gate bipolar transistors based two-level topologies. 展开更多
关键词 Power electronics power factor correction three-level converter efficiency.
下载PDF
Vector Control Strategy of a T-type Three-level Converter Driving a Switched Reluctance Motor 被引量:6
11
作者 Mingyao Ma Zhuangzhi Wang +2 位作者 Qingqing Yang Shuying Yang Xing Zhang 《Chinese Journal of Electrical Engineering》 CSCD 2019年第4期15-21,共7页
A novel 12 voltage vector control strategy for switched reluctance motors(SRM)with a T-type three-level converter is proposed in this study.Based on a causal analysis of torque ripple under the control of conventional... A novel 12 voltage vector control strategy for switched reluctance motors(SRM)with a T-type three-level converter is proposed in this study.Based on a causal analysis of torque ripple under the control of conventional six voltage vectors,six new voltage vectors are added for further reduction of torque ripple.An optimized control rule is adopted based on the division method of the 12 new voltage vectors.A zero-voltage vector is used to adjust the duration of the 12 voltage vectors,the time of which is varied at different parts of the vector sectors according to the torque error.In addition,the windings are connected in a delta configuration,therefore,the number of connections between the converter and SRM is reduced.Finally,the results of MATLAB/Simulink and RT-LAB are presented to verify the validity of the proposed scheme. 展开更多
关键词 Switched reluctance motor(SRM) T-type three-level converter vector control
原文传递
DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System 被引量:38
12
作者 ZHAO ChengYong XU JianZhong LI Tan 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第1期253-261,共9页
Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locat... Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locating and isolating of DC faults and corresponding DC faults ride-through capability evaluation index.This paper introduces the topology mechanism of FBMMC and its loss reduction operation mode,theoretically certifies that the universal decoupled control strategy of Voltage Source Converter(VSC) and the similar modulation strategies of Half-Bridge MMC(HBMMC) can be applied to FBMMC for constructing complete closed-loop control system.On the basis of the existing DC faults locating and isolating schemes of 2-level VSC based Multi-Terminal HVDC(VSC-MTDC) system and the particularity of FBMMC,this paper proposes the DC faults wire selection "handshaking" method of the FBMMC-MTDC system,and proposes the DC Fault Ride-Through Capability Index(DFRTI) for evaluating the DC faults suppressing capability of the VSC-MTDC systems,including FBMMC-MTDC.Simulations of FBMMC-MTDC in PSCAD/EMTDC validate the correctness and effectiveness of the proposed control strategy and evaluation index. 展开更多
关键词 full-bridge modular multilevel converter multi-terminal flexible HVDC handshaking method DC fault ride-through capability index(DFRTI)
原文传递
Neutral-point-clamped hybrid multilevel converter with DC fault blocking capability for medium-voltage DC transmission 被引量:3
13
作者 Xinyu YU Yingdong WEI +3 位作者 Qirong JIANG Xiaorong XIE Yuquan LIU Ke WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期524-536,共13页
This paper proposes a novel hybrid multilevel converter with DC fault-blocking capability, i.e., the neutral-point clamped hybrid multilevel converter(NHMC).By employing two types of unipolar full-bridge submodules al... This paper proposes a novel hybrid multilevel converter with DC fault-blocking capability, i.e., the neutral-point clamped hybrid multilevel converter(NHMC).By employing two types of unipolar full-bridge submodules along with director switches, which are composed of seriesconnected insulated-gate bipolar transistors, the NHMC combines the features and advantages of the neutral-point clamped converter and the modular multilevel converter.The basic topology, operating principles, modulation scheme, and energy-balancing scheme of the NHMC are presented. The DC fault-blocking capability of the NHMC is investigated. The number of power electronic devices used by the NHMC is calculated and compared with other multilevel converters, showing that the proposed NHMC can be an economical and feasible option for medium-voltage DC transmission with overhead lines. Simulation results demonstrate the features and operating scheme of the proposed NHMC. 展开更多
关键词 Neutral-point-clamped hybrid multilevel converter(NHMC) Unipolar full-bridge submodule(UFBSM) DC fault blocking capability Modulation scheme
原文传递
A DC Chopper Topology to Mitigate Commutation Failure of Line Commutated Converter Based High Voltage Direct Current Transmission 被引量:5
14
作者 Chunyi Guo Bo Liu Chengyong Zhao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第2期345-355,共11页
To reduce the probability of commutation failure(CF)of a line commutated converter based high-voltage direct current(LCC-HVDC)transmission,a DC chopper topology composed of power consumption sub-modules based on thyri... To reduce the probability of commutation failure(CF)of a line commutated converter based high-voltage direct current(LCC-HVDC)transmission,a DC chopper topology composed of power consumption sub-modules based on thyristor full-bridge module(TFB-PCSM)is proposed.Firstly,the mechanism of the proposed topology to mitigate CF is analyzed,and the working modes of TFB-PCSM in different operation states are introduced.Secondly,the coordinated control strategy between the proposed DC chopper and LCC-HVDC is designed,and the voltage-current stresses of the TFB-PCSMs are investigated.Finally,the ability to mitigate the CF issues and the fault recovery performance of LCC-HVDC system are studied in PSCAD/EMTDC.The results show that the probability of CF of LCC-HVDC is significantly reduced,and the performances of fault recovery are effectively improved by the proposed DC chopper. 展开更多
关键词 Line commutated converter based high-voltage direct current(LCC-HVDC)transmission DC chopper power consumption sub-module based on thyristor full-bridge module(TFB-PCSM) commutation failure(CF) fault recovery capability
原文传递
A novel technology for control of variable speed pumped storage power plant 被引量:1
15
作者 Seyed Mohammad Hassan Hosseini Mohammad Reza Semsar 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2008-2023,共16页
Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(V... Variable speed pumped storage machines are used extensively in wind power plant and pumped storage power plant. This paper presents direct torque and flux control(DTFC) of a variable speed pumped storage power plant(VSPSP). By this method both torque and flux have been applied to control the VSPSP. The comparison between VSPSP's control strategies is studied. At the first, a wind turbine with the capacity 2.2 k W and DTFC control strategies simulated then a 250 MW VSPSP is simulated with all of its parts(including electrical, mechanical, hydraulic and its control system) by MATLAB software. In all of simulations, both converters including two-level voltage source converter(2LVSC) and three-level voltage source converter(3LVSC) are applied. The results of applying 2LVSC and 3LVSC are the rapid dynamic responses with better efficiency, reducing the total harmonic distortion(THD) and ripple of rotor torque and flux. 展开更多
关键词 direct torque and flux control(DTFC) two-level three-level voltage source converter(2LVSC&3LVSC) variable speed pumped storage power plant(VSPSP)
下载PDF
A zero-voltage zero-current soft switching DC/DC converter
16
作者 WANG Zheng-shi LOU Zhen-li +1 位作者 ZENG Yu-zhu ZHANG Zhong-chao 《Frontiers of Electrical and Electronic Engineering in China》 CSCD 2006年第4期385-389,共5页
A novel three-level zero-voltage zero-current switching(ZVZCS)DC/DC converter is proposed in this paper.A tapped-inductor is used to replace the normal out-put filter inductor,so that the circulating current in the ze... A novel three-level zero-voltage zero-current switching(ZVZCS)DC/DC converter is proposed in this paper.A tapped-inductor is used to replace the normal out-put filter inductor,so that the circulating current in the zero-state can be reset to zero.The reset voltage and the re-set time can be set conveniently just by simply changing the winding ratio of the tapped inductor.The converter achieves a zero-current tuning off for inner switching,and a zero-voltage tuning on for outer switching.No circulating current exists in the zero state,so that the loss in the on-state is reduced,and the efficiency can be improved.The experimental results verify that the ZVZCS has low voltage stress,zero-voltage and zero-current switching. 展开更多
关键词 three-level DC/DC converter tapped inductor SOFT-SWITCHING
原文传递
Wind energy conversion system using perturb&observe-based maximum power point approach interfaced with T-type three-level inverter connected to grid 被引量:1
17
作者 Pranupa S A.T.Sriram S.Nagaraja Rao 《Clean Energy》 EI 2022年第4期534-549,共16页
In this paper,the performance of a permanent magnet synchronous generator(PMSG)-based wind energy conversion system(WECS)supplied to an uncontrolled rectifier-fed boost converter(BC)interfaced with a three-phase T-typ... In this paper,the performance of a permanent magnet synchronous generator(PMSG)-based wind energy conversion system(WECS)supplied to an uncontrolled rectifier-fed boost converter(BC)interfaced with a three-phase T-type three-level inverter(TLI)has been analysed.The proposed WECS involves three converters,namely an uncontrolled rectifier that is used for conversion from AC to DC;a BC supplied by a PMSG-fed rectifier used to enhance the voltage gain;and a grid-connected three-phase T-type TLI is proposed to eliminate power-quality issues with synchronization of grid voltage and current.The main goal of this research is to model and control the grid-connected T-type TLI using a d-q synchronous frame for wind energy for regulating the DC-link voltage and transferring the generated wind power from the BC to the grid.Furthermore,the perturb&observe(P&O)-based maximum power point(MPP)approach is recommended to keep track of the MPP for a BC that is supplied from a PMSG-based WECS under constant and variable wind speeds.The proposed PMSG-based WECS interfaced with grid-connected T-type TLI using d-q control has been computationally modelled,simulated and validated with constant and variable speeds using MATLAB®and Simulink®.It is confirmed that the P&O-based MPP approach ensures maximum power for varying wind speeds,and the total harmonic distortion of the T-type TLI grid current value is 3.18%,which is within IEEE-519 limits.Furthermore,with grid synchronization,the power factor of the T-type TLI is maintained at unity to avoid power-quality issues. 展开更多
关键词 boost converter grid synchronization perturb&observe T-type three-level inverter wind turbine
原文传递
A Model Predictive Control Method for Hybrid Energy Storage Systems 被引量:3
18
作者 Siyuan Chen Qiufan Yang +1 位作者 Jianyu Zhou Xia Chen 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第2期329-338,共10页
The traditional PI controller for a hybrid energy storage system(HESS)has certain drawbacks,such as difficult tuning of the controller parameters and the additional filters to allocate high-and low-frequency power flu... The traditional PI controller for a hybrid energy storage system(HESS)has certain drawbacks,such as difficult tuning of the controller parameters and the additional filters to allocate high-and low-frequency power fluctuations.This paper proposes a model predictive control(MPC)method to control three-level bidirectional DC/DC converters for grid-connections to a HESS in a DC microgrid.First,the mathematical model of a HESS consisting of a battery and ultra capacitor(UC)is established and the neutral point voltage imbalance of a three-level converter is solved by analyzing the operating modes of the converter.Secondly,for the control of the grid-connected converters,an MPC method is proposed for calculating steady-state reference values in the outer layer and the dynamic rolling optimization in the inner layer.The outer layer ensures the voltage regulation and establishes the current predictive model,while the inner layer,using the model predictive current control,makes the current follow the predictive value,thus reducing the system current ripple.This cascaded topology has two independent controllers and is free of filters to realize the high-and low-frequency power allocation for a HESS.Therefore,it allows two types of energy storage devices to independently regulate the voltage and realizes the power allocation of the battery and UC.Finally,simulation studies are conducted in PSCAD/EMTDC,and the effectiveness of the proposed HESS control strategy is verified in a case,such as a controller comparison and fault scenario. 展开更多
关键词 Double layer control method hybrid energy storage system(HESS) model predictive control(MPC) three-level DC/DC converter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部