期刊文献+
共找到871篇文章
< 1 2 44 >
每页显示 20 50 100
THREE-PHASE BRIDGE INVERTER FOR 9kW DOUBLY SALIENT PERMANENT MAGNET MOTOR
1
作者 黄伟君 秦海鸿 +1 位作者 王慧贞 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2006年第1期27-33,共7页
The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve... The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct. 展开更多
关键词 doubly salient permanent magnet motor three-phase bridge inverter winding back EMF position signal of hall sensor input voltage
下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
2
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE inverter three-phase FOUR-LEG inverter Unbalanced Load Imbalanced VOLTAGE
下载PDF
RELIABLE HYSTERESIS CURRENT CONTROLLED DUAL BUCK HALF BRIDGE INVERTER 被引量:6
3
作者 刘军 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2003年第1期67-72,共6页
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple... A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters. 展开更多
关键词 high frequency switch ing inverterS hysteresis current control half bridge
下载PDF
A new three-phase 5-level current-source inverter 被引量:4
4
作者 BAO Jian-yu BAI Zhi-hong +1 位作者 WANG Qing-song ZHANG Zhong-chao 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第12期1973-1978,共6页
The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw... The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly. 展开更多
关键词 three-phase Current-source inverter (CSI) 5-level HARMONICS POD PWM
下载PDF
H6 Non-isolated Full Bridge Grid-connected PV Inverters With Low Leakage Currents 被引量:29
5
作者 ZHANG Li SUN Kai +2 位作者 FENG Lanlan XING Yan XU Ming 《中国电机工程学报》 EI CSCD 北大核心 2012年第15期I0001-I0022,21,共22页
为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有... 为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有利于热应力均衡,且仍满足续流阶段光伏电池输出端与电网脱离的要求。详细分析拓扑的工作原理,并推论给出H6非隔离光伏并网逆变器的其它3种拓扑结构;比较分析了H5拓扑、Heric拓扑和H6拓扑的损耗和成本。通过1kW通用样机平台对比验证了上述3种拓扑的效率和共模特性。实验结果表明,H6拓扑的变换效率高于H5拓扑、但略低于Heric拓扑,共模特性优于Heric拓扑、但略劣于H5拓扑。 展开更多
关键词 全桥逆变器 并网逆变器 漏电流 共模电压 光伏发电
下载PDF
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
6
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
Symmetrical dynamical characteristic of peak and valley current-mode controlled single-phase H-bridge inverter 被引量:2
7
作者 刘洪臣 李飞 +1 位作者 苏振霞 孙立山 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第11期226-231,共6页
Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were estab... Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current. 展开更多
关键词 single-phase H-bridge inverter symmetrical dynamical phenomenon folding map bifurcation di-agram
下载PDF
The Research of Three-phase Boost/Buck-boost DC-AC Inverter
8
作者 Xiangli Li Zhaoyang Yan +1 位作者 Yanni Gao Hanhong Qi 《Energy and Power Engineering》 2013年第4期906-913,共8页
This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ... This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application. 展开更多
关键词 three-phase BOOST SINGLE-STAGE inverter three-phase BUCK-BOOST SINGLE-STAGE inverter Double-loop CONTROLLER Sliding Mode CONTROLLER
下载PDF
The improved PAC method for a three-phase PWM grid-connected inverter
9
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Research of Mining STATCOM Based on Hybrid Multilevel H-bridge Inverter
10
作者 Yaopu Li Cong Wang +1 位作者 Xu Zhao Kai Zhang 《Energy and Power Engineering》 2013年第4期636-641,共6页
The paper presents a new STATCOM system based on H-bridge inverter. It can be used in mine power network. It has been commonly verified for the positive effects of SVG on the reactive power compensation and voltage fl... The paper presents a new STATCOM system based on H-bridge inverter. It can be used in mine power network. It has been commonly verified for the positive effects of SVG on the reactive power compensation and voltage fluctuation suppression. This paper focuses on a generalized structure of multilevel power converter where individual voltage sources are not necessarily the same. The cascade H-bridge consists of two cells, high-voltage cell and low-voltage cell. The high-voltage cell is responsible for voltage lifting, while the low-voltage cell is responsible for PWM modulation. If two cells are cascaded with DC voltages in a ratio of 2:1, the single-phase output voltage can reach 7 levels. Increasing voltage levels of output waveform can bring up AC current quality, optimize harmonic spectrum and enhance converter efficiency. The hybrid multilevel is characterized by per-phase series connection of a high-voltage H-bridge converter and a low-voltage H-bridge converter. Due to the different capacitor voltage, it is a key problem as to how to maintain the capacitor’s voltage at a reference level. Independent DC source can effectively ensure the DC voltage. Through the reactive power compensation technology, the three-phase voltage and current can remain at the same phase. 展开更多
关键词 H-bridge STATCOM SVG HYBRID Coal MINE PWM Control inverter
下载PDF
Harmonic Distortion Rate Analysis of H-Bridges Multilevel Inverter
11
作者 Mohamed Nejib Ben Nasr Khammassi Anis Kebir Faouzi Ben Ammar 《材料科学与工程(中英文B版)》 2011年第3期308-315,共8页
关键词 多电平逆变器 H桥 失真率 PWM技术 谐波 技术标准 电源开关 控制技术
下载PDF
Finite Set-Model Predictive Current Control of Three-Phase Voltage Source Inverter for RES (Renewable Energy Systems) Applications
12
作者 Ali Almaktoof Atanda Raji Tariq Kahn 《Journal of Energy and Power Engineering》 2014年第4期749-756,共8页
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f... This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system. 展开更多
关键词 Finite set-model predictive control three-phase voltage source inverter renewable energy system application AC filter Matlab/Simulink.
下载PDF
THD Analysis of Cascaded H-Bridge Inverter with Fuzzy Logic Controller
13
作者 Sivakumar N. Sumathi A. 《Circuits and Systems》 2017年第7期171-183,共13页
In recent days, the multilevel inverter technology is widely applied to domestic and industrial applications for medium voltage conversion. But, the power quality issues of the multilevel inverter limit the usage of m... In recent days, the multilevel inverter technology is widely applied to domestic and industrial applications for medium voltage conversion. But, the power quality issues of the multilevel inverter limit the usage of much sensitive equipment like medical instruments. The lower distortion level of the output voltage and current can generate a quality sinusoidal output voltage in inverters and they can be used for many applications. The harmonics can cause major problems in equipments due to the nonlinear loads connected with the power system. So, it is necessary to minimize the losses to raise its overall efficiency. In this paper, a new topology of seven level asymmetrical cascaded H-bridge multilevel inverter with a Fuzzy logic controller had been implemented to reduce the Total Harmonic Distortion (THD) and to improve the overall performance of the inverter. The proposed model is well suited for use with a solar PV application. In this topology, only six IGBT switches are used with three different voltage ratings of PV modules (1:2:4). The lower number of semiconductor switches leads to minimizing overall di/dt ratings and voltage stress on each switches and switching losses. The gate pulses generated by Sinusoidal Pulse Width Modulation (SPWM) technique with a Fuzzy logic controller are also introduced. A buck-boost converter is used to maintain the constant PV voltage level integrated by an MPPT technique followed by Perturb and Observer algorithm is also implemented. The MPPT is used to harness the maximum power of solar radiations under its various climatic conditions. The new topology is evaluated by a Matlab/Simulink model and compared with a hardware model. The results proved that the THD achieved by this topology is 1.66% and realized that it meets the IEEE harmonic standards. 展开更多
关键词 Cascaded H-bridge MULTILEVEL inverter THD Photo Voltaic Modules SPWM Fuzzy LOGIC Controller MPPT Technique
下载PDF
Capacitor Pattern H-Bridge Multilevel Inverter (CPHMLI) Using Phase Diposition Pulse Width Modulation for Grid Applications
14
作者 M. S. Saravanan R. Jeyabharath 《Circuits and Systems》 2016年第10期3310-3319,共10页
This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of ... This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of a proper number of Capacitor connected with switches and power sources. The advanced switching control supplied by Pulse Width Modulation (PDPWM) to attain mixed staircase switching state. The charging and discharging mode are achieved by calculating the voltage error at the load. Furthermore, to accomplish the higher voltage levels at the output with less number of semiconductors switches and simple commutation designed using CPHMLI topology. To prove the performance and effectiveness of the proposed approach, a set of experiments performed under various load conditions using MATLAB tool. 展开更多
关键词 Switched Capacitor Multilevel inverter Phase Diposition Pulse Width Modulation Capacitor Pattern Based Multilevel inverter Total Harmonic Distortion Cascaded H-bridge 17-Level inverter
下载PDF
Graphene Bridge Heterostructure Devices for Negative Differential Transconductance Circuit Applications
15
作者 Minjong Lee Tae Wook Kim +6 位作者 Chang Yong Park Kimoon Lee Takashi Taniguchi Kenji Watanabe Min‑gu Kim Do Kyung Hwang Young Tack Lee 《Nano-Micro Letters》 SCIE EI CAS CSCD 2023年第2期161-171,共11页
Two-dimensional van der Waals(2D vdW)material-based heterostructure devices have been widely studied for high-end electronic applications owing to their heterojunction properties.In this study,we demonstrate graphene(... Two-dimensional van der Waals(2D vdW)material-based heterostructure devices have been widely studied for high-end electronic applications owing to their heterojunction properties.In this study,we demonstrate graphene(Gr)-bridge heterostructure devices consisting of laterally series-connected ambipolar semiconductor/Gr-bridge/n-type molybdenum disulfide as a channel material for field-effect transistors(FET).Unlike conventional FET operation,our Gr-bridge devices exhibit nonclassical transfer characteristics(humped transfer curve),thus possessing a negative differential transconductance.These phenomena are interpreted as the operating behavior in two series-connected FETs,and they result from the gate-tunable contact capacity of the Gr-bridge layer.Multi-value logic inverters and frequency tripler circuits are successfully demonstrated using ambipolar semiconductors with narrow-and wide-bandgap materials as more advanced circuit applications based on non-classical transfer characteristics.Thus,we believe that our innovative and straightforward device structure engineering will be a promising technique for future multi-functional circuit applications of 2D nanoelectronics. 展开更多
关键词 Graphene bridge Heterostructure device Non-classical transfer characteristics Multi-value logic inverter Frequency tripler
下载PDF
New Approach of Multi-Cell Stacked Cell Inverter for Solar Photovoltaic System
16
作者 François Yonga Colince Welba +1 位作者 Abdouramani Dadjé Noël Djongyang 《Journal of Power and Energy Engineering》 2023年第1期1-17,共17页
In this paper, a new inverter topology dedicated to isolated or grid-connected PV systems is proposed. This inverter is based on the structures of a stacked multi-cell converter (SMC) and an H-bridge. This new topolog... In this paper, a new inverter topology dedicated to isolated or grid-connected PV systems is proposed. This inverter is based on the structures of a stacked multi-cell converter (SMC) and an H-bridge. This new topology has allowed the voltage stresses of the converter to be distributed among several switching cells. Secondly, divide the input voltage into several fractions to reduce the number of power semiconductors to be switched. In this contribution, the general topology of this micro-inverter has been described and the simulation tests developed to validate its operation have been presented. Finally, we discussed the simulation results, the efficiency of this topology and the feasibility of its use in a grid-connected photovoltaic production system. 展开更多
关键词 Photovoltaic System MICRO-inverter Stacked Multi-Cell Converter (SMC) H-bridge Pulse Width Modulation (PWM)
下载PDF
Topological Comparison and Analysis of Medium-voltage and High-power Direct-linked PV Inverter 被引量:14
17
作者 Xing Zhang Mingda Wang +3 位作者 Tao Zhao Wang Mao Yuhua Hu Renxian Cao 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期327-334,共8页
Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-pow... Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-power systems,large-scale PV systems are more commercially attractive,because they can reduce the cost of the system per watt.The PV inverters with centralized and string structure have been applied in large-scale PV plant,but it is difficult to further increase the voltage and power levels for a single converter.In addition,the line-frequency isolation transformer requires a large amount of materials and has a large volume and weight.Therefore,it is a current trend for large-scale PV system to increase the voltage and power levels to directly connect to the medium-voltage power grid.Based on this,this paper investigates and compares several topologies of PV inverters without line-frequency transformer,including the MMC structure and the three-phase cascaded H-bridge(CHB)structure,which are able to directly connect to the 35kV medium-voltage power grid,and can not only make the voltage and power levels higher,but also further reduce the cost and volume of the whole system. 展开更多
关键词 Direct-linked PV inverter large-scale PV system MMC structure three-phase CHB structure.
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
18
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
A New Structure of Multilevel Inverter with Reduced Number of Switches for Electric Vehicle Applications 被引量:1
19
作者 M. Ebadpour M. B. B. Sharifian S. H. Hosseini 《Energy and Power Engineering》 2011年第2期198-205,共8页
Both Hybrid Electric Vehicles (HEVs) and Electric Vehicles (EVs) need a traction motor and a power in-verter to drive the traction motor. The requirements for the power inverter include high peak power, opti-mum consu... Both Hybrid Electric Vehicles (HEVs) and Electric Vehicles (EVs) need a traction motor and a power in-verter to drive the traction motor. The requirements for the power inverter include high peak power, opti-mum consumption of energy, low output harmonics and inexpensive circuit. In this paper, a new structure of multilevel inverter with reduced number of switches is proposed for electric vehicle applications. It consists of an H-bridge and an inverter in each phase which produces multilevel voltage by switching the dc voltage sources in series. As the number of switches are reduced, both conduction and switching losses will be de-creased, which leads to increase the efficiency of converter. The size and power consumption of driving cir-cuits are also reduced. The proposed three phase inverter can produces more number of voltage levels in the same number of the voltage source and reduced number of switches compared to the conventional inverters. This structure minimizes the total harmonic distortion (THD) of the output voltage waveforms. The structure of proposed multilevel inverter, modulation method, switching losses, THD calculation and simulation re-sults with PSCAD/EMTDC software are shown in this paper. 展开更多
关键词 Cascaded H-bridge Electric VEHICLES (EVs) Hybrid Modulation inverterS TRACTION Motors
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
20
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter three-phase GRID-CONNECTED inverter DECOUPLING Control
下载PDF
上一页 1 2 44 下一页 到第
使用帮助 返回顶部