The improved PAC method for a three-phase PWM grid-connected inverter
1
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
2
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
3
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
4
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE invertER three-phase four-leg invertER Unbalanced Load Imbalanced VOLTAGE
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
5
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter three-phase grid-connected inverter DECOUPLING Control
下载PDF
Highly efficient three-phase grid-connected parallel inverter system 被引量:3
6
作者 Evren ISEN Ahmet Faruk BAKAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第5期1079-1089,共11页
In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the gr... In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype. 展开更多
关键词 Active filter invertER efficiency RIPPLE CANCELLATION three-phase grid-connected invertER
原文传递