期刊文献+
共找到18篇文章
< 1 >
每页显示 20 50 100
The improved PAC method for a three-phase PWM grid-connected inverter
1
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Generalized thermoelastic interaction in functional graded material with fractional order three-phase lag heat transfer 被引量:3
2
作者 Ibrahim A.Abbas 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第5期1606-1613,共8页
The present work is concerned with the solution of a problem on thermoelastic interactions in a functional graded material due to thermal shock in the context of the fractional order three-phase lag model. The governi... The present work is concerned with the solution of a problem on thermoelastic interactions in a functional graded material due to thermal shock in the context of the fractional order three-phase lag model. The governing equations of fractional order generalized thermoelasticity with three-phase lag model for functionally graded materials(FGM)(i.e., material with spatially varying material properties) are established. The analytical solution in the transform domain is obtained by using the eigenvalue approach.The inversion of Laplace transform is done numerically. The graphical results indicate that the fractional parameter has significant effects on all the physical quantities. Thus, we can consider the theory of fractional order generalized thermoelasticity an improvement on studying elastic materials. 展开更多
关键词 three-phase lag model fimctionally graded materials fractional calculus generalized thermoelasticity
下载PDF
Effective electroelastic constants for three-phase confocal elliptical cylinder model in piezoelectric quasicrystal composites 被引量:5
3
作者 Yongbin WANG Junhong GUO 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2018年第6期797-812,共16页
A three-phase confocal elliptical cylinder model is proposed to analyze micromechanics of one-dimensional hexagonal piezoelectric quasicrystal (PQC) compos- ites. Exact solutions of the phonon, phason, and electric ... A three-phase confocal elliptical cylinder model is proposed to analyze micromechanics of one-dimensional hexagonal piezoelectric quasicrystal (PQC) compos- ites. Exact solutions of the phonon, phason, and electric fields are obtained by using the conformal mapping combined with the Laurent expansion technique when the model is subject to far-field anti-plane mechanical and in-plane electric loadings. The effective elec- troelastic constants of several different composites made up of PQC, quasicrystal (QC), and piezoelectric (PE) materials are predicted by the generalized self-consistent method. Numerical examples are conducted to show the effects of the volume fraction and the cross-sectional shape of inclusion (or fiber) on the effective electroelastic constants of these composites. Compared with other micromechanical methods, the generalized self- consistent and Mori-Tanaka methods can predict the effective electroelastic constants of the composites consistently. 展开更多
关键词 piezoelectric quasicrystal (PQC) three-phase elliptical cylinder model effective constant generalized self-consistent method
下载PDF
A novel dynamic equivalence method for grid-connected wind farm 被引量:2
4
作者 Jia-geng QIAO Zong-xiang LU Yong MIN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第4期558-563,共6页
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, a... Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method. 展开更多
关键词 grid-connected wind farm Dynamic equivalence Squirrel-Cage Induction generator (SCIG) Genetic algorithm
下载PDF
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
5
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
6
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
7
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter three-phase grid-connected Inverter DECOUPLING Control
下载PDF
Predictive direct power control of three-phase PWM rectifier based on TOGI grid voltage sensor free algorithm
8
作者 ZHAO Feng LI Shute +4 位作者 CHEN Xiaoqiang WANG Ying GAN Yanqi NIU Xinqiang ZHANG Fan 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第4期451-459,共9页
In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)i... In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results. 展开更多
关键词 three-phase PWM rectifier predictive direct power control grid voltage sensor free algorithm third-order generalized integrator power correction
下载PDF
Grid-Connected PV Solar Energy Converter with Active and Reactive Power Control
9
作者 Roberto F. Coelho Artur Pagnoncelli Galbiatti Denizar Cruz Martins 《Journal of Energy and Power Engineering》 2014年第2期331-342,共12页
This work proposes a 12 kW three-phase grid-connected single stage PWM DC-AC converter destined to process the energy provided by a photovoltaic array composed of 57 KC200GT PV modules with high power factor for any s... This work proposes a 12 kW three-phase grid-connected single stage PWM DC-AC converter destined to process the energy provided by a photovoltaic array composed of 57 KC200GT PV modules with high power factor for any solar radiation. The PWM inverter modeling and the control strategy, using dqO transformation, are proposed in order to also allow the system operation as an active power filter, capable to compensate harmonic components and react power generated by the non-linear loads connected to the mains grid. An input voltage clamping technique is proposed to impose the photovoltaic operation on the maximum power point. Simulation and experimental results are presented to validate the proposed methodology for grid connected photovoltaic generation system. 展开更多
关键词 Active and reactive power dqO transformation grid-connected PV systems three-phase DC-AC PWM converter.
下载PDF
Current Loop Disturbance Suppression for Dual Three Phase Permanent Magnet Synchronous Generators Based on Modified Linear Active Disturbance Rejection Control
10
作者 Dezhi Xu Hu Yao +1 位作者 Yang He Wenxiang Zhao 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第1期101-113,共13页
A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d a... A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d and q axis currents in the d-q subspace and harmonic currents in the x-y subspace.In the d-q subspace,the proposed strategy uses a model-based LADRC to enhance the decoupling effect between the d and q axes and the disturbance rejection ability against parameter variation.In the x-y subspace,the 5th and 7th harmonic current suppression abilities are improved by using quasi-resonant units parallel to the extended state observer of the traditional LADRC.The proposed modified LADRC strategy improved both the steady-state performance and dynamic response of the DTP-PMSG system.The experimental results demonstrate that the proposed strategy is both feasible and effective. 展开更多
关键词 Dual three-phase permanent magnet synchronous generator current loop decoupling control harmonic suppression linear active disturbance rejection control
原文传递
Highly efficient three-phase grid-connected parallel inverter system 被引量:3
11
作者 Evren ISEN Ahmet Faruk BAKAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第5期1079-1089,共11页
In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the gr... In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype. 展开更多
关键词 Active filter INVERTER efficiency RIPPLE CANCELLATION three-phase grid-connected INVERTER
原文传递
Three-phase AC-DC Converter for Direct-drive PMSG-based Wind Energy Conversion System 被引量:1
12
作者 Kumar Abhishek Singh Ayushi Chaudhary Kalpana Chaudhary 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第2期589-598,共10页
In this paper,a wind energy conversion system(WECS)is presented for the electrification of rural areas with wind energy availability.A three-phase AC-DC converter based on a bridgeless Cuk converter is used for power ... In this paper,a wind energy conversion system(WECS)is presented for the electrification of rural areas with wind energy availability.A three-phase AC-DC converter based on a bridgeless Cuk converter is used for power extraction from the permanent magnet synchronous generator(PMSG).The bridgeless topology enables the elimination of the front-end diode bridge rectifier(DBR).Moreover,the converter has fewer components,simple control,and high efficiency,making it suitable for a small-scale WECS.A squirrel cage induction motor(SCIM)is used to emulate a MOD-2 wind turbine to implement the PMSG-based WECS.A direct-drive eight-pole PMSG is used in this study;thus,a low-input-voltage system is designed.The converter is designed to operate in the discontinuous inductor current mode(DICM)for inherent power factor correction(PFC)and the maximum power point tracking(MPPT)is achieved through the tip-speed ratio(TSR)following.The performance of the developed system is analyzed through simulation,and a 500 W hardware prototype is developed and tested in different wind speed conditions. 展开更多
关键词 Permanent magnet synchronous generator(PMSG) three-phase AC-DC converter wind energy conversion system(WECS) wind turbine emulator
原文传递
Multi-area distributed three-phase state estimation for unbalanced active distribution networks 被引量:5
13
作者 Sheng CHEN Zhinong WEI +3 位作者 Guoqiang SUN Ning LU Yonghui SUN Ying ZHU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第5期767-776,共10页
This paper proposes a new multi-area framework for unbalanced active distribution network(ADN) state estimation. Firstly, an innovative three-phase distributed generator(DG) model is presented to take the asymmetric c... This paper proposes a new multi-area framework for unbalanced active distribution network(ADN) state estimation. Firstly, an innovative three-phase distributed generator(DG) model is presented to take the asymmetric characteristics of DG three-phase outputs into consideration. Then a feasible method to set pseudo-measurements for unmonitored DGs is introduced. The states of DGs,together with the states of alternating current(AC) buses in ADNs, were estimated by using the weighted least squares(WLS) method. After that, the ADN was divided into several independent subareas. Based on the augmented Lagrangian method, this work proposes a fully distributed three-phase state estimator for the multi-area ADN.Finally, from the simulation results on the modified IEEE123-bus system, the effectiveness and applicability of the proposed methodology have been investigated and discussed. 展开更多
关键词 Active distribution networks(ADNs) Distributed three-phase state estimation three-phase distributed generator(DG)models Pseudo-measurements Augmented Lagrangian
原文传递
Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator
14
作者 Victor A.F.Almeida Glauco N.Taranto José M.T.Marinho 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第6期1269-1278,共10页
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.... This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations. 展开更多
关键词 Converter-interfaced generator three-phase model power system protection negative-sequence current injection negative-sequence current protection unbalanced fault three-phase root-mean-square(RMS)dynamic simulation
原文传递
Large-signal modeling of three-phase dual active bridge converters for electromagnetic transient analysis in DC grids
15
作者 Maxime BERGER Ilhan KOCAR +1 位作者 Handy FORTIN-BLANCHETTE Carl LAVERTU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第6期1684-1696,共13页
The three-phase dual active bridge(3 p-DAB)converter is widely considered in next-generation DC grid applications.As for traditional AC grids,the successful integration of power electronic converters in DC grids requi... The three-phase dual active bridge(3 p-DAB)converter is widely considered in next-generation DC grid applications.As for traditional AC grids,the successful integration of power electronic converters in DC grids requires accurate time-domain system-level studies.As demonstrated in the existing literature,the development and efficient implementation of large-signal models of 3 pDAB converters are not trivial.In this paper,a generalized average model is developed,which enables system-level simulation of DC grids with 3 p-DAB converters in electromagnetic transient type(EMT-type)programs.The proposed model is rigorously compared with alternative modeling techniques:ideal-model,switching-function and state-space averaging.It is concluded that the generalized average model provides an optimal solution when accuracy of transient response,reduction in computation time,and wideband response factors are considered. 展开更多
关键词 three-phase DUAL ACTIVE bridge(3p-DAB) generalized AVERAGING Large-signal analysis Electromagnetic transient DC–DC conversion
原文传递
Wind Energy Conversion System from Electrical Perspective—A Survey
16
作者 Hyong Sik Kim Dylan Dah-Chuan Lu 《Smart Grid and Renewable Energy》 2010年第3期119-131,共13页
This paper focuses on the wind energy conversion system (WECS) with the three main electrical aspects: 1) wind turbine generators (WTGs), 2) power electronics converters (PECs) and 3) grid-connection issues. The curre... This paper focuses on the wind energy conversion system (WECS) with the three main electrical aspects: 1) wind turbine generators (WTGs), 2) power electronics converters (PECs) and 3) grid-connection issues. The current state of wind turbine generators are discussed and compared in some criteria along with the trends in the current WECS market, which are ‘Variable Speed’, ‘Multi-MW’ and ‘Offshore’. In addition, the other crucial component in the WECS, PECs will be discussed with its topologies available in the current WECS market along with their modulation strategies. Moreover, three main issues of the WECS associating with the grid-connection, fault-ride through (FRT) capability, harmonics/interharmonics emission and flicker, which are the power quality issues, will be discussed due to the increasing responsibility of WECS as utility power station. Some key findings from the review such as the attractiveness of BDFRG are presented in the conclusion of this paper. 展开更多
关键词 WIND Energy WIND Turbine generators POWER Electronic Converters grid-connection BRUSHLESS Reluctance Pulse-Width Modulation Fault RIDE through Capability Voltage DIP Harmonics FLICKER POWER Quality BDFRG
下载PDF
Parameters Analysis and Operational Area Calculations of VSG Applied to Distribution Networks 被引量:1
17
作者 Zhipeng Lyu Xiaotong Gong +1 位作者 Linxu Liu Lan Liu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第6期2214-2223,共10页
Virtual synchronous generator(VSG)technology is an effective way to realize coordinated energy supply of active distribution networks and comprehensive energy at present.This paper starts from the two perspectives of ... Virtual synchronous generator(VSG)technology is an effective way to realize coordinated energy supply of active distribution networks and comprehensive energy at present.This paper starts from the two perspectives of grid-connected operational modes and island operational modes.Based on the mathematical model of VSG,referring to existing grid standards,comprehensively considering its active and reactive-power loop stability and dynamic performance,the influencing factors of the related control parameters K,Dq,J,Dp are analyzed.And selection range for K,Dq,J,Dp is proposed,which ensures stability and robustness in grid-connected and island operational modes.In this paper,this method can be used as a reference for control strategy research and practical engineering applications of VSG.Finally,effects of parameter selection on stability and dynamic performance of active and reactive-power loops are analyzed by using the zero-pole map and Bode diagram,and feasibility of the scheme is verified by PSCAD/EMTDC. 展开更多
关键词 Active-power loop grid-connected island operation modes parameters design reactive-power loop stability analyzes virtual synchronous generator
原文传递
Modeling and control of photovoltaic energy conversion connected to the grid 被引量:2
18
作者 Rebei NAJET Ben Ghanem BELGACEM Hasnaoui OTHMAN 《Frontiers in Energy》 CSCD 2012年第1期35-46,共12页
This paper presents modeling and control of a photovoltaie generator (PVG) connected to the grid. The parameters of the PVG have been identified in previous work (series and parallel resistance, reverse saturation ... This paper presents modeling and control of a photovoltaie generator (PVG) connected to the grid. The parameters of the PVG have been identified in previous work (series and parallel resistance, reverse saturation current and thermal voltage) using Newton-Raphston and the gradient algorithm. The electrical energy from a PVG is transferred to the grid via two static converters (DC/DC and DC/AC). The objective of the proposed control strategy is to maximize energy captured from the PVG. The adapted control law for extracting maximum power from the PVG is based on the incremental conductance algorithm. The developed algorithm has the capability of searching the maximum photovoltaic power under variable irradiation and temperature. To control the DC/AC inverter, an intelligent system based on two structures is constructed: a current source control structure and a voltage source control structure. The system has been validated by numerical simulation using data obtained from the PVG installed in the laboratory research (INSAT, Tunisia). 展开更多
关键词 photovoltaic generator (PVG) maximum power point tracker grid-connected static converters
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部