An ultra-high voltage(UHV)composite bypass switch(BPS)faces increasing seismic challenges when UHV projects extend to high seismic intensity areas.The UHV composite BPS still generates excessive stress at the bottom s...An ultra-high voltage(UHV)composite bypass switch(BPS)faces increasing seismic challenges when UHV projects extend to high seismic intensity areas.The UHV composite BPS still generates excessive stress at the bottom section although hollow composite insulators with high flexural strength are adopted.Since the standard retrofitting strategy by using stiffer supports cannot reduce stress responses,wire rope isolation is introduced.The optimal design of isolation considers both stress and displacement responses since the slenderness and composite material of insulators contribute to significant displacement.The results show that properly designed isolation can significantly reduce stress without excessive displacement responses.A larger radius configuration helps to improve the applicability of small stiffness isolators under high winds.When the isolation still cannot satisfy the requirement,smaller stiffness isolators with a larger radius,or isolators with increased loops and smaller radius,can be introduced to gain better energy dissipation capacity and effectiveness in response mitigation.Accordingly,a three-step design procedure is proposed to increase the damping force but fix the rotational stiffness of isolation.Hence,the application of wire rope isolation can be extended to UHV composite BPS with a low natural frequency,but conductors with enough redundancy should be used.展开更多
This paper reports a contact cantilever MEMS switch. The designed switch has a metal cantilever that acts as an electrostatically activated switch with processing options to achieve dielectric isolation of the control...This paper reports a contact cantilever MEMS switch. The designed switch has a metal cantilever that acts as an electrostatically activated switch with processing options to achieve dielectric isolation of the controlvoltage path from the signal path. To obtain good material properties,an ANSYS FEA tool is used to optimize the structure. The RF MEMS switch is fabricated via a surface micromachining process. The switch has an actuation voltage of 12V,which is close to the simulated value of 11V. The measured and the HFSS simulated isolations are both higher than - 20dB from 0.05 to 10GHz. The measured insertion loss is less than - 0.9dB, relatively larger than the simulated loss of less than - 0.2dB from 0.05 to 10GHz. This is because a contact resistance introduced due to poor physical contact between the bottom lines and the metal cantilever.展开更多
基金National Natural Science Foundation of China under Grant No.51878508National Key R&D Program of China under Grant No.2018YFC0809400。
文摘An ultra-high voltage(UHV)composite bypass switch(BPS)faces increasing seismic challenges when UHV projects extend to high seismic intensity areas.The UHV composite BPS still generates excessive stress at the bottom section although hollow composite insulators with high flexural strength are adopted.Since the standard retrofitting strategy by using stiffer supports cannot reduce stress responses,wire rope isolation is introduced.The optimal design of isolation considers both stress and displacement responses since the slenderness and composite material of insulators contribute to significant displacement.The results show that properly designed isolation can significantly reduce stress without excessive displacement responses.A larger radius configuration helps to improve the applicability of small stiffness isolators under high winds.When the isolation still cannot satisfy the requirement,smaller stiffness isolators with a larger radius,or isolators with increased loops and smaller radius,can be introduced to gain better energy dissipation capacity and effectiveness in response mitigation.Accordingly,a three-step design procedure is proposed to increase the damping force but fix the rotational stiffness of isolation.Hence,the application of wire rope isolation can be extended to UHV composite BPS with a low natural frequency,but conductors with enough redundancy should be used.
文摘This paper reports a contact cantilever MEMS switch. The designed switch has a metal cantilever that acts as an electrostatically activated switch with processing options to achieve dielectric isolation of the controlvoltage path from the signal path. To obtain good material properties,an ANSYS FEA tool is used to optimize the structure. The RF MEMS switch is fabricated via a surface micromachining process. The switch has an actuation voltage of 12V,which is close to the simulated value of 11V. The measured and the HFSS simulated isolations are both higher than - 20dB from 0.05 to 10GHz. The measured insertion loss is less than - 0.9dB, relatively larger than the simulated loss of less than - 0.2dB from 0.05 to 10GHz. This is because a contact resistance introduced due to poor physical contact between the bottom lines and the metal cantilever.