Direct on Line Starting Induction Motor with Thyristor Switched Capacitor Based Voltage Regulation
1
作者 E.P.da Silveira R.C. Pires A.T.L.de Almeida A.J.J. Rezek 《Journal of Energy and Power Engineering》 2010年第9期49-55,共7页
The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting o... The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting on an emulated weak transmission line. Thyristor switched capacitor bank was chosen because it is a well known topology, considering the very nature of the direct starting induction motors, which represents a highly inductive load, the use of switched reactors becomes unnecessary. Such fact minimizes the introduction of harmonics components, and also reduces the cost of the implementation. The binary disposition of the banks allows a variable Var compensation with sixteen steps, in this case. The solution makes use of low cost devices combined with sliding window voltage and current measurement algorithm and a PI control with dead band control for achieve the shown experimental results, where the system is able to manage a typically 20% voltage drop, reducing it to less than 4%. The schematic of the developed circuit, the control technique and a quite simple method to calculate the binary weight capacitors banks are also presented. 展开更多
关键词 Induction motor thyristor switched capacitor voltage regulation
下载PDF
A Study of High-Power Thyristor Switch of Poloidal-Field Power Supply System in HT-7U Super-Conductive Tokamak
2
作者 温家良 刘正之 +1 位作者 付鹏 许家治 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第5期1005-1010,共6页
Through theoretical analysis of thyristor switch, criterion of turn-off was derived for the design of thyristor switch. The expression of parameter design and its math model during the turn-off were deduced. The simul... Through theoretical analysis of thyristor switch, criterion of turn-off was derived for the design of thyristor switch. The expression of parameter design and its math model during the turn-off were deduced. The simulation and experiment have been accomplished to validate the analysis. 展开更多
关键词 A Study of High-Power thyristor Switch of Poloidal-Field Power Supply System in HT-7U Super-Conductive Tokamak HT
下载PDF
Hetero-integrated high-peak-optical-power laser source (940 nm) for time-of-flight sensors
3
作者 Sergey Olegovich Slipchenko Aleksandr Aleksandrovich Podoskin +9 位作者 Ilia Vasil'evich Shushkanov Marina Gennad'evna Rastegaeva Artem Eduardovich Rizaev Matvey Igorevich Kondratov Artem Evgen'evich Grishin Nikita Aleksandrovich Pikhtin Timur Anatol'evich Bagaev Maxim Anatol'evich Ladugin Aleksandr Anatol'evich Marmalyuk Vladimir Aleksandrovich Simakov 《Chinese Optics Letters》 SCIE EI CAS CSCD 2024年第7期81-85,共5页
The generation of high-power laser pulses using a compact hetero-integrated assembly based on a semiconductor laser with a dual-element composite 2μm×100μm aperture and a compact heterothyristor switch is demon... The generation of high-power laser pulses using a compact hetero-integrated assembly based on a semiconductor laser with a dual-element composite 2μm×100μm aperture and a compact heterothyristor switch is demonstrated.The achieved peak optical power was 33 W with a pulse duration of 3 ns at a thyristor operating voltage of 55 V.The leading edge of the laser pulse turn-on was 50 ps to a power level of 24.7 W,and the turn-on delay between the elements of the composite aperture was 160 ps. 展开更多
关键词 hetero-integrated assembly semiconductor lasers thyristor switches LIDAR gain-switching mode laser heterostructure
原文传递
Impact of FACTS devices on exercising market power in deregulated electricity market 被引量:1
4
作者 Shanmugam PRABHAKAR KARTHIKEYAN I. JACOB RAGLEND D. P. KOTHARI 《Frontiers in Energy》 SCIE CSCD 2013年第4期448-455,共8页
In power system studies, congestion in trans- mission lines and utilization of flexible alternating current transmission system (FACTS) devices are closely associated. These devices are very important due to their r... In power system studies, congestion in trans- mission lines and utilization of flexible alternating current transmission system (FACTS) devices are closely associated. These devices are very important due to their role in power delivery system enhancement. It is to be noted that the generation companies can exercise their market power which depends on the line flows, line constraints, generators' location and its share to the individual loads. This issue cannot be overlooked as it creates monopoliness which is against the deregulated market policy. The objective of this paper is to study the impact of market power when FACTS devices like thyristor controlled switching capacitor (TCSC) and thyristor controlled phase angle regulator (TCPAR) are used under steady state operation. The market power is determined using nodal must-run share (NMRS) index for the standard IEEE 14- bus system with and without the above FACTS devices and the results obtained are compared. All the above simula- tions are conducted in a MATLAB 7.9-R2009b environment. 展开更多
关键词 flexible alternating current transmission system (FACTS) thyristor controlled switching capacitor (TCSC) thyristor controlled phase angle regulator (TCPAR) market power must-run generation (MRG) nodal must-run share (NMRS)