期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
NUMERICAL ANALYSIS AND EXPERI-MENT OF UNSTEADY THERMAL FIELD OF ROTOR PLATE FOR EDDY CURRENT RETARDER 被引量:10
1
作者 LIU Chengye HE Ren 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第4期71-75,共5页
The physical model based on heat transfer theory and virtual boundary method for analyzing unsteady thermal field of rotor plate for eddy current retarder used in automobile is established and boundary conditions are ... The physical model based on heat transfer theory and virtual boundary method for analyzing unsteady thermal field of rotor plate for eddy current retarder used in automobile is established and boundary conditions are also defined. The finite element governing equation is derived by Galerkin method. The time differential item is discrete based on Galerkin format that is stable at any condition. And a new style of varying time step method is used in iteration process. The thermal field on the rotor plate at the radial and axle directions is analyzed and varying temperature at appointed points on two side-surfaces is measured. The testing and analytical data are uniform approximately. Finite element method can be used for estimating thermal field of the rotor plate at initial design stage of eddy current retarder. 展开更多
关键词 Eddy current retarder Thermal field Numerical analysis Varying time step method
下载PDF
A sensitive and compact mercury analyzer by integrating dielectric barrier discharge induced cold vapor generation and optical emission spectrometry 被引量:1
2
作者 An-Qin Leng Yun-Fei Tian +4 位作者 Ming-Xuan Wang Li Wu Kai-Lai Xu Xian-Deng Hou Cheng-Bin Zheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第2期189-196,共8页
An environmentally friendly,low power consuming,sensitive and compact mercury analyzer was developed for the determination of mercury in water samples by integrating a thin film dielectric barrier discharge induced co... An environmentally friendly,low power consuming,sensitive and compact mercury analyzer was developed for the determination of mercury in water samples by integrating a thin film dielectric barrier discharge induced cold vapor reactor and a dielectric barrier discharge optical emission spectrometer into a small polymethyl methacrylate plate(10.5 cm length×8.0 cm width×1.2 cm height).Mercury cold vapor was generated when standard or sample solutions with or without formic acid were introduced to the reactor to form thin film liquid and exposed to microplasma irradiation and subsequently separated from the liquid phase for transport to the microplasma and detection of its atomic emission.Limits of detection of 0.20 μg L^-1 and 2.6 μg L^-1 were obtained for the proposed system using or not using formic acid,respectively.Compared to the conventional microplasma optical emission spectrometry used for mercury analysis,this system not only retains the good limit of detection amenable to the determination of mercury in real samples,but also reduces power consumption,eliminates the generation of hydrogen and avoids the use of toxic or unstable reductant.Method validation was demonstrated by analysis of a certified reference material of water sample and three real water samples with good spike recoveries(88-102%). 展开更多
关键词 Mercury Real time field analysis Microplasma Optical emission spectrometry Cold vapor generation Miniaturization
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部