Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL...Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL) is developed to provide a rather simple and robust structure with both the high scanning speed and the large delay length.The developed system is used for THz spectroscopic measurements and imaging of the corneal tissue with different amounts of water content,and the measurement results show the consistence with the reported results,in which the measurement time using VCM-ODL is a factor of 360 shorter than the traditional motorized optical delay line(MDL).With reducing the water content a monotonic decrease of the complex permittivity of the cornea is observed.The two-term Debye relaxation model is employed to explain our experimental results,revealing that the fast relaxation time of a dehydrated cornea is much larger than that of a hydrated cornea and its dielectric behavior can be affected by the presence of the biological macromolecules.These results demonstrate that our THz spectrometer may be a promising candidate for tissue hydration sensing and practical application of THz technology.展开更多
The target motion analysis(TMA) for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception(TOI) measurements only is investigated in this paper.By transforming the...The target motion analysis(TMA) for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception(TOI) measurements only is investigated in this paper.By transforming the TOI of multiple scan cycles into the direction difference of arrival(DDOA) model,the observability analysis for the TMA problem is performed.Some necessary conditions for uniquely identifying the scanning emitter trajectory are obtained.This paper also proposes a weighted instrumental variable(WIV) estimator for the scanning emitter TMA,which does not require any initial solution guess and is closed-form and computationally attractive.More importantly,simulations show that the proposed algorithm can provide estimation mean square error close to the Cramer-Rao lower bound(CRLB) at moderate noise levels with significantly lower estimation bias than the conventional pseudo-linear least square(PLS) estimator.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.61205101)the Shenzhen Municipal Research Foundation,China(Grant Nos.GJHZ201404171134305 and JCYJ20140417113130693)the Marie Curie Actions-International Research Staff Exchange Scheme(IRSES)(Grant No.FP7 PIRSES-2013-612267)
文摘Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL) is developed to provide a rather simple and robust structure with both the high scanning speed and the large delay length.The developed system is used for THz spectroscopic measurements and imaging of the corneal tissue with different amounts of water content,and the measurement results show the consistence with the reported results,in which the measurement time using VCM-ODL is a factor of 360 shorter than the traditional motorized optical delay line(MDL).With reducing the water content a monotonic decrease of the complex permittivity of the cornea is observed.The two-term Debye relaxation model is employed to explain our experimental results,revealing that the fast relaxation time of a dehydrated cornea is much larger than that of a hydrated cornea and its dielectric behavior can be affected by the presence of the biological macromolecules.These results demonstrate that our THz spectrometer may be a promising candidate for tissue hydration sensing and practical application of THz technology.
基金co-supported by the Shanghai Aerospace Science and Technology Innovation Fund of China(No.SAST2015028)the Equipment Prophecy Fund of China(No.9140A21040115KG01001)
文摘The target motion analysis(TMA) for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception(TOI) measurements only is investigated in this paper.By transforming the TOI of multiple scan cycles into the direction difference of arrival(DDOA) model,the observability analysis for the TMA problem is performed.Some necessary conditions for uniquely identifying the scanning emitter trajectory are obtained.This paper also proposes a weighted instrumental variable(WIV) estimator for the scanning emitter TMA,which does not require any initial solution guess and is closed-form and computationally attractive.More importantly,simulations show that the proposed algorithm can provide estimation mean square error close to the Cramer-Rao lower bound(CRLB) at moderate noise levels with significantly lower estimation bias than the conventional pseudo-linear least square(PLS) estimator.