期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
LMS-LIKE ESTIMATION FOR TIME VARYING PARAMETERS
1
作者 陈翰馥 郭雷 张纪峰 《Acta Mathematica Scientia》 SCIE CSCD 1991年第3期327-340,共14页
An LMS-like algorithm is applied for estimating the time-varying parameter theta-n in the linear model y(n) = phi-n-tau-theta-n + upsilon-n, which is general in the sense that none of the probabilistic properties such... An LMS-like algorithm is applied for estimating the time-varying parameter theta-n in the linear model y(n) = phi-n-tau-theta-n + upsilon-n, which is general in the sense that none of the probabilistic properties such as stationarity, Markov property, independence and ergodicity is imposed on any of the processes {y(n)}, {phi-n}, {theta-n} and {upsilon-n}. It is shown that the alpha-th moment of the estimation error is of order of the alpha-th moment of the observation noise and the parameter variation w(n) change in equivalence theta-n - theta-n-1. 展开更多
关键词 LMS-LIKE ESTIMATION FOR time varying parameters der Zhang ACTA 石蕊 少司
下载PDF
Adaptive bolus chasing computed tomography angiography by a local linear time and space parameter varying model:modeling,control,identification,and experimental results
2
作者 Zhijun CAI Ge WANG Er-Wei BAI 《Frontiers of Electrical and Electronic Engineering in China》 CSCD 2010年第2期119-127,共9页
A high contrast to noise ratio(CNR)is always desirable for contrast-enhanced computed tomography angiography(CTA).To ensure a high CNR of the vascular images in CTA and potentially reduce the radiation exposure and co... A high contrast to noise ratio(CNR)is always desirable for contrast-enhanced computed tomography angiography(CTA).To ensure a high CNR of the vascular images in CTA and potentially reduce the radiation exposure and contrast usage,an adaptive bolus chasing method is proposed and evaluated compared to the existing constant-speed method.The proposed method is based on a local time and space parameter varying model of the contrast bolus.Optimal scan time for the next segment of the vasculature is estimated and predicted in real time and guides the computed tomography(CT)scanner table movement that guarantees that each segment of the vasculature is scanned with the maximum possible enhancement.Simulations and experimental results show that the proposed bolus chasing method outperforms the conventional constant-speed method substantially. 展开更多
关键词 adaptive control bolus chasing computed tomography angiography(CTA) local linear time and space parameter varying model
原文传递
上一页 1 下一页 到第