An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutin...An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutines,designated for locating faults on particular line sections,and additionally the procedure for selecting the valid subroutine.The subroutines are formulated with use of the generalized fault loop model and the distributed parameter line model is applied.Performed ATP-EMTP based evaluation has shown the validity of the derived fault location algorithm and its high accuracy.展开更多
The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contai...The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.展开更多
We study the dynamics of two electron spins in coupled quantum dots (CQDs) monitored by a quantum point contact (QPC) detector. Their quantum state can be measured by embedding the QPC in an LC circuit. We derive ...We study the dynamics of two electron spins in coupled quantum dots (CQDs) monitored by a quantum point contact (QPC) detector. Their quantum state can be measured by embedding the QPC in an LC circuit. We derive the Bloch-type rate equations of the reduced density matrix for CQDs. Special attention is paid to the numerical results for the weak measurement condintion under a strong Coulomb interaction. It is shown that the evolution of QPC current always follows that of electron occupation in the right dot. In addition, we find that the output voltage of the circuit can reflect the evolution of QPC current when the circuit and QPC are approximately equal in frequency. In particular, the wave shape of the output voltage can be improved by adjusting the circuit resonance frequency and bandwidth.展开更多
At present,the over-travel measurement of high-voltage circuit breakers is mostly carried out after the circuit breaker is completely dismantled.The disadvantage of the measurement is that it can only be measured when...At present,the over-travel measurement of high-voltage circuit breakers is mostly carried out after the circuit breaker is completely dismantled.The disadvantage of the measurement is that it can only be measured when the circuit breaker is dismantled and overhauled.Defects are diagnosed in a timely and effective manner,and capacity causes hidden troubles.This article provides a method for direct measurement of hydraulic circuit breakers without any adjustment or disassembly.The method can be carried out in various situations such as minor repairs,major repairs,and temporary repairs,which not only saves time,but also improves accuracy of the measurement.The comparative test results show that this method can be simple,convenient and effective to measure the overtravel of the high-voltage circuit breaker.展开更多
短路分断是断路器的核心功能,提高断路器的短路分断能力是市场的持续需求。针对有效提升塑壳断路器(Moulded Case Circuit Breaker,MCCB)短路分断能力的方法开展了研究。利用栅片电压测量分析法可以检测灭弧栅片在短路分断时切割电弧的...短路分断是断路器的核心功能,提高断路器的短路分断能力是市场的持续需求。针对有效提升塑壳断路器(Moulded Case Circuit Breaker,MCCB)短路分断能力的方法开展了研究。利用栅片电压测量分析法可以检测灭弧栅片在短路分断时切割电弧的情况,评估各灭弧栅片切割电弧的性能以及电弧在灭弧室内的动态特性,为电弧优化提供参考数据。利用有限元仿真的方法进行电磁力计算,有利于快速验证优化设计方案而免去实际的试验验证,节约产品的研发成本,缩短产品的研发周期。蒸汽喷射控制(Vapour Jet Control,VJC)产气材料的运用也能够进一步提高产品的短路分断能力。综合运用以上设计方法,能够在不会大幅增加研发成本的基础上,快速提升MCCB的短路分断能力,工程应用价值较好。展开更多
文摘An accurate fault location algorithm for double-circuit series compensated lines is presented.Use of two-end unsynchronized measurements of current and voltage signals is considered.The algorithm applies two subroutines,designated for locating faults on particular line sections,and additionally the procedure for selecting the valid subroutine.The subroutines are formulated with use of the generalized fault loop model and the distributed parameter line model is applied.Performed ATP-EMTP based evaluation has shown the validity of the derived fault location algorithm and its high accuracy.
文摘The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.
基金Project supported by the National Natural Science Foundation of China (Grant No.11174358)the National Basic Research Program of China (Grant No.2010CB833102)
文摘We study the dynamics of two electron spins in coupled quantum dots (CQDs) monitored by a quantum point contact (QPC) detector. Their quantum state can be measured by embedding the QPC in an LC circuit. We derive the Bloch-type rate equations of the reduced density matrix for CQDs. Special attention is paid to the numerical results for the weak measurement condintion under a strong Coulomb interaction. It is shown that the evolution of QPC current always follows that of electron occupation in the right dot. In addition, we find that the output voltage of the circuit can reflect the evolution of QPC current when the circuit and QPC are approximately equal in frequency. In particular, the wave shape of the output voltage can be improved by adjusting the circuit resonance frequency and bandwidth.
文摘At present,the over-travel measurement of high-voltage circuit breakers is mostly carried out after the circuit breaker is completely dismantled.The disadvantage of the measurement is that it can only be measured when the circuit breaker is dismantled and overhauled.Defects are diagnosed in a timely and effective manner,and capacity causes hidden troubles.This article provides a method for direct measurement of hydraulic circuit breakers without any adjustment or disassembly.The method can be carried out in various situations such as minor repairs,major repairs,and temporary repairs,which not only saves time,but also improves accuracy of the measurement.The comparative test results show that this method can be simple,convenient and effective to measure the overtravel of the high-voltage circuit breaker.