Electrical Impedance Tomography(EIT)as a non-invasive of electrical conductivity imaging method commonly employs the stationary-coefficient based filters(such as FFT)in order to remove the noise signal.In the practica...Electrical Impedance Tomography(EIT)as a non-invasive of electrical conductivity imaging method commonly employs the stationary-coefficient based filters(such as FFT)in order to remove the noise signal.In the practical applications,the stationary-coefficient based filters fail to remove the time-varying random noise which leads to the lack of impedance measurement sensitivity.In this paper,the implementation of adaptive noise cancellation(ANC)algorithms which are Least Mean Square(LMS)and Normalized Least Mean Square(NLMS)filters onto Field Programmable Gate Array(FPGA)-based EIT system is proposed in order to eliminate the time-varying random noise signal.The proposed method was evaluated through experimental studies with biomaterial phantom.The reconstructed EIT images with NLMS is better than the images with LMS by amplitude response AR=12.5%,position error PE=200%,resolution RES=33%,and shape deformation SD=66%.Moreover,the Analog-to-Digital Converter(ADC)performances of power spectral density(PSD)and the effective number of bit ENOB with NLMS is higher than the performances with LMS by SI=5.7%and ENOB=15.4%.The results showed that implementing ANC algorithms onto FPGA-based EIT system shows significantly more accurate image reconstruction as compared without ANC algorithms implementation.展开更多
针对当前的有源消弧方法因谐波电流检测精度不足而效果较差,以及传统消弧线圈在谐波影响下容易导致消弧失败的问题,设计了一种无须谐波检测便可有效抑制故障点残流中谐波分量的新型消弧线圈。该消弧线圈由逆变器并联传统消弧线圈构成,...针对当前的有源消弧方法因谐波电流检测精度不足而效果较差,以及传统消弧线圈在谐波影响下容易导致消弧失败的问题,设计了一种无须谐波检测便可有效抑制故障点残流中谐波分量的新型消弧线圈。该消弧线圈由逆变器并联传统消弧线圈构成,其中逆变器的指令电压根据中性点电位进行调整,可使逆变器支路不产生基波电流;逆变器的低谐波阻抗特性可有效降低故障点残流中的谐波分量;同时传统消弧线圈过补偿可抵消电容电流。经过Matlab和PSCAD/EMTDC(power systems computer aided design/electromagnetic transients including direct current)仿真,结果显示新型消弧线圈将故障点处的5次谐波、7次谐波分别由25.62、65.85 A降低到了0.11、0.57 A,能够实现可靠消弧。该研究在配电网消弧领域具有一定的应用前景。展开更多
Alumina coating was formed on AA7075 aluminum alloy by micro arc oxidation(MAO) method and its corrosion and stress corrosion cracking(SCC) behaviors were examined in 3.5%(mass fraction) NaCl solution.Electroche...Alumina coating was formed on AA7075 aluminum alloy by micro arc oxidation(MAO) method and its corrosion and stress corrosion cracking(SCC) behaviors were examined in 3.5%(mass fraction) NaCl solution.Electrochemical impedance spectroscopy(EIS) was used to evaluate the degradation of the coating as a function of immersion time and was modeled with appropriate equivalent circuits.Constant load stress corrosion cracking(SCC) results followed by post-test metallographic observations demonstrated the usefulness of MAO coating to avoid the premature failure of the alloy due to severe localized corrosion initiated by Cu-and Fe-rich intermetallic phases.展开更多
Fe-based coatings reinforced by spherical tungsten carbide were deposited on 304 stainless steel using plasma transferred arc(PTA) technology.The composition and phase microstructure of the coatings were evaluated usi...Fe-based coatings reinforced by spherical tungsten carbide were deposited on 304 stainless steel using plasma transferred arc(PTA) technology.The composition and phase microstructure of the coatings were evaluated using scanning electron microscopy(SEM),energy dispersive spectrometer(EDS) and X-ray diffraction(XRD).The corrosion behaviors of the coatings in 0.5 mol/L HCl solution were studied using polarization curve and electrochemical impedance spectroscopy(EIS) measurements.The experimental results shows that the tungsten carbide improves the corrosion resistance of the Fe-based alloy coating,but increase in the mass fraction of tungsten carbide leads to increasing amount of defects of holes and cracks,which results in an adverse effect on the corrosion resistance.The defects are mainly present on the tungsten carbide but also extend to the Fe-based matrix.The tungsten carbide,acting as a cathode,and binding material of Fe-based alloy,acting as an anode,create a galvanic corrosion cell.The binding material is preferentially corroded and causes the degradation of the coating.展开更多
In this paper we present a series of monthly gravity field solutions from Gravity Recovery and Climate Experiment(GRACE) range measurements using modified short arc approach,in which the ambiguity of range measureme...In this paper we present a series of monthly gravity field solutions from Gravity Recovery and Climate Experiment(GRACE) range measurements using modified short arc approach,in which the ambiguity of range measurements is eliminated via differentiating two adjacent range measurements.The data used for developing our monthly gravity field model are same as Tongji-GRACEOl model except that the range measurements are used to replace the range rate measurements,and our model is truncated to degree and order 60,spanning Jan.2004 to Dec.2010 also same as Tongji-GRACE01 model.Based on the comparison results of the C_(2,0),C_(2,1),S_(2,1),and C_(15,15),S_(15,15),time series and the global mass change signals as well as the mass change time series in Amazon area of our model with those of Tongji-GRACE01 model,we can conclude that our monthly gravity field model is comparable with Tongji-GRACE01 monthly model.展开更多
resistance,and adhesive strength of vacuum-arc multi-period NbN/Cu coatings is studied.It was found that in thin layers(about 8 nm,in a constant rotation mode),regardless of the change in the pressure of the nitrogen ...resistance,and adhesive strength of vacuum-arc multi-period NbN/Cu coatings is studied.It was found that in thin layers(about 8 nm,in a constant rotation mode),regardless of the change in the pressure of the nitrogen atmosphere,a metastableδ-NbN phase forms(cubic crystal lattice of the NaCl type).At a layer thickness of^40 nm or more,a phase composition changes from the metastableδ-NbN to the equilibriumε-NbN phase with a hexagonal crystal lattice.In the presence of theε-NbN phase in the niobium nitride layers,the highest adhesive strength is achieved with a value of LС5=96.5 N.Corrosion resistance tests have shown that for all the studied samples the corrosion process has mainly an anodic reaction.The highest corrosion resistance was shown by coatings obtained at a pressure of 7·10-4 Torr,with the smallest bias potential of-50 V and the smallest layer thickness;with a thickness of such a coating of about 10 microns,its service life in the environment of the formation of chloride ions is about a year.展开更多
基金he International Research Fellow of Japan Society for the Promotion of Science(Graduate School of Science and Engineering,Chiba University)and JSPS KAKENHI Grant Number JP18F18060.
文摘Electrical Impedance Tomography(EIT)as a non-invasive of electrical conductivity imaging method commonly employs the stationary-coefficient based filters(such as FFT)in order to remove the noise signal.In the practical applications,the stationary-coefficient based filters fail to remove the time-varying random noise which leads to the lack of impedance measurement sensitivity.In this paper,the implementation of adaptive noise cancellation(ANC)algorithms which are Least Mean Square(LMS)and Normalized Least Mean Square(NLMS)filters onto Field Programmable Gate Array(FPGA)-based EIT system is proposed in order to eliminate the time-varying random noise signal.The proposed method was evaluated through experimental studies with biomaterial phantom.The reconstructed EIT images with NLMS is better than the images with LMS by amplitude response AR=12.5%,position error PE=200%,resolution RES=33%,and shape deformation SD=66%.Moreover,the Analog-to-Digital Converter(ADC)performances of power spectral density(PSD)and the effective number of bit ENOB with NLMS is higher than the performances with LMS by SI=5.7%and ENOB=15.4%.The results showed that implementing ANC algorithms onto FPGA-based EIT system shows significantly more accurate image reconstruction as compared without ANC algorithms implementation.
文摘针对当前的有源消弧方法因谐波电流检测精度不足而效果较差,以及传统消弧线圈在谐波影响下容易导致消弧失败的问题,设计了一种无须谐波检测便可有效抑制故障点残流中谐波分量的新型消弧线圈。该消弧线圈由逆变器并联传统消弧线圈构成,其中逆变器的指令电压根据中性点电位进行调整,可使逆变器支路不产生基波电流;逆变器的低谐波阻抗特性可有效降低故障点残流中的谐波分量;同时传统消弧线圈过补偿可抵消电容电流。经过Matlab和PSCAD/EMTDC(power systems computer aided design/electromagnetic transients including direct current)仿真,结果显示新型消弧线圈将故障点处的5次谐波、7次谐波分别由25.62、65.85 A降低到了0.11、0.57 A,能够实现可靠消弧。该研究在配电网消弧领域具有一定的应用前景。
文摘Alumina coating was formed on AA7075 aluminum alloy by micro arc oxidation(MAO) method and its corrosion and stress corrosion cracking(SCC) behaviors were examined in 3.5%(mass fraction) NaCl solution.Electrochemical impedance spectroscopy(EIS) was used to evaluate the degradation of the coating as a function of immersion time and was modeled with appropriate equivalent circuits.Constant load stress corrosion cracking(SCC) results followed by post-test metallographic observations demonstrated the usefulness of MAO coating to avoid the premature failure of the alloy due to severe localized corrosion initiated by Cu-and Fe-rich intermetallic phases.
基金the China Postdoctoral Science Foundation(No.2017M620153)the Science&Technology Program of Shanghai Jian Qiao University(No.SJQ19012)。
文摘Fe-based coatings reinforced by spherical tungsten carbide were deposited on 304 stainless steel using plasma transferred arc(PTA) technology.The composition and phase microstructure of the coatings were evaluated using scanning electron microscopy(SEM),energy dispersive spectrometer(EDS) and X-ray diffraction(XRD).The corrosion behaviors of the coatings in 0.5 mol/L HCl solution were studied using polarization curve and electrochemical impedance spectroscopy(EIS) measurements.The experimental results shows that the tungsten carbide improves the corrosion resistance of the Fe-based alloy coating,but increase in the mass fraction of tungsten carbide leads to increasing amount of defects of holes and cracks,which results in an adverse effect on the corrosion resistance.The defects are mainly present on the tungsten carbide but also extend to the Fe-based matrix.The tungsten carbide,acting as a cathode,and binding material of Fe-based alloy,acting as an anode,create a galvanic corrosion cell.The binding material is preferentially corroded and causes the degradation of the coating.
基金sponsored by National Natural Science Foundation of China(41474017)National Key Basic Research Program of China(973 Program+3 种基金2012CB957703)sponsored by National Natural Science Foundation of China(41274035)State Key Laboratory of Geodesy and Earth's Dynamics(SKLGED2013-3-2-Z,SKLGED2014-1-3-E)State Key Laboratory of Geo-Information Engineering(SKLGIE2014-M-1-2)
文摘In this paper we present a series of monthly gravity field solutions from Gravity Recovery and Climate Experiment(GRACE) range measurements using modified short arc approach,in which the ambiguity of range measurements is eliminated via differentiating two adjacent range measurements.The data used for developing our monthly gravity field model are same as Tongji-GRACEOl model except that the range measurements are used to replace the range rate measurements,and our model is truncated to degree and order 60,spanning Jan.2004 to Dec.2010 also same as Tongji-GRACE01 model.Based on the comparison results of the C_(2,0),C_(2,1),S_(2,1),and C_(15,15),S_(15,15),time series and the global mass change signals as well as the mass change time series in Amazon area of our model with those of Tongji-GRACE01 model,we can conclude that our monthly gravity field model is comparable with Tongji-GRACE01 monthly model.
文摘resistance,and adhesive strength of vacuum-arc multi-period NbN/Cu coatings is studied.It was found that in thin layers(about 8 nm,in a constant rotation mode),regardless of the change in the pressure of the nitrogen atmosphere,a metastableδ-NbN phase forms(cubic crystal lattice of the NaCl type).At a layer thickness of^40 nm or more,a phase composition changes from the metastableδ-NbN to the equilibriumε-NbN phase with a hexagonal crystal lattice.In the presence of theε-NbN phase in the niobium nitride layers,the highest adhesive strength is achieved with a value of LС5=96.5 N.Corrosion resistance tests have shown that for all the studied samples the corrosion process has mainly an anodic reaction.The highest corrosion resistance was shown by coatings obtained at a pressure of 7·10-4 Torr,with the smallest bias potential of-50 V and the smallest layer thickness;with a thickness of such a coating of about 10 microns,its service life in the environment of the formation of chloride ions is about a year.