Hypoxia is a common pathological process in various clinical diseases and is characterized by abnormal changes in metabolism, function, and morphological structure of tissues resulting from insufficient oxygen supply ...Hypoxia is a common pathological process in various clinical diseases and is characterized by abnormal changes in metabolism, function, and morphological structure of tissues resulting from insufficient oxygen supply or oxygen barriers in tissues. In particular, hypoxia in vital organs such as the brain and heart is an important cause of death;. The prevention of tissue hypoxia and the展开更多
In order to find out the distribution characteristics of BTEX in groundwater, which include Benzene, Toluene, Ethylbenzene, p-Xylene, m-Xylene, and o-Xylene, 82 groups of groundwater samples and 10 surface water sampl...In order to find out the distribution characteristics of BTEX in groundwater, which include Benzene, Toluene, Ethylbenzene, p-Xylene, m-Xylene, and o-Xylene, 82 groups of groundwater samples and 10 surface water samples collected from Guangzhou in Guangdong during 2005 to 2008 were tested by gas chromatography and mass spectrum(GC/MS). The result showed that the BTEX concentration in groundwater does not exceed the standard. The detection rate of BTEX is 14.63% in groundwater, and the total BTEX concentration is lower than 9.5 μg/L. Of 6 kinds of BTEX, toluene had the highest detection rate(12.20%) and detection value(9.5 μg/L), which was followed by Benzene, with the detection rate of 3.65%, and detection value of 4.9 μg/L respectively; most of samples with BTEX are distributed in Huangpu district, Baiyun district, Huadu district and other industrialized areas; this spatial distribution and urban distribution have obvious consistency. With economic development, plant expansion and population growth led to a large amount of waste water discharge, and infrastructure construction is lagging behind, indicating that rapid urbanization is a major driving force of BTEX in groundwater, and through the analysis of a typical area, it is found that benzene system surface water infiltration was an important source of BTEX in groundwater of Guangzhou.展开更多
With the current,our country social economy rapid development,people's living standard and quality of life and therefore have got improved,at the same time,it is the concept of environmental protection and energy ...With the current,our country social economy rapid development,people's living standard and quality of life and therefore have got improved,at the same time,it is the concept of environmental protection and energy saving is also enhanced value,many fields in our country environmental protection and energysaving concept can be seen in the application,especially the application in building water supply and drainage design more widely,to protect the environment,to maximize the use of limited resources,how to reasonable use of water resources in building water supply and drainage construction,above is current the paper mainly discusses the problems in the construction field,this paper based on environmental protection and energy-saving concept,discusses its application in the building water supply and drainage design,for your reference.展开更多
Background Cockroaches are an important indoor allergen source causing allergic rhinitis and asthma. The aim of this study was to investigate the cockroach prevalence in mainland of China and the cross-reactivity of I...Background Cockroaches are an important indoor allergen source causing allergic rhinitis and asthma. The aim of this study was to investigate the cockroach prevalence in mainland of China and the cross-reactivity of IgE between cockroach and house dust mite allergen in Chinese patients.Methods The cockroach sensitization pattern was based on a skin prick test (SPT) obtained from a national multicenter prevalence study, in which 6304 patients from 25 allergy centers across China participated. Factors, including different regions of China, age, gender and the correlations between the American and German cockroaches and house dust mite Der p were investigated. Eighteen out of 1236 clinical sera from south China were selected to perform the cross-inhibition assay between house dust mites and cockroaches.Results Totally 25.7% of patients were SPT positive to the American cockroach (Periplaneta Americana, Per a) and 18.7% SPT positive to the German cockroach (Blattella germanica, Bla g). The prevalence of positive cockroach SPT was higher in southern than in northern China, higher in adults than in children, and higher in males than in females.Patients had relatively low levels of cockroach SPT reactions, mainly class 1 or 2. Of the SPT positive cockroach patients,88% were also SPT positive to house dust mite (Dermatophagoides pteronyssinus, Der p). An IgE cross-inhibition study confirmed that Der P sensitization could cause false positive SPT reactions against cockroach.Conclusions A relatively high prevalence of cockroach sensitivity was found in mainland of China. However, a cross-inhibition study showed that only a small number of patients appear to have Bla g and/or Per a as primary sensitizing source. The importance of cockroaches as a risk factor for sensitization and triggers of allergic symptoms in mainland of China needs to be further investigated.展开更多
基金financially supported by 1226 major project [Grant no.AWS16J018]
文摘Hypoxia is a common pathological process in various clinical diseases and is characterized by abnormal changes in metabolism, function, and morphological structure of tissues resulting from insufficient oxygen supply or oxygen barriers in tissues. In particular, hypoxia in vital organs such as the brain and heart is an important cause of death;. The prevention of tissue hypoxia and the
基金supported by Special Scientific Research Projects on Environmental Protection(201409029)Major Investigation Project of National Land and Resources(1212011121167)
文摘In order to find out the distribution characteristics of BTEX in groundwater, which include Benzene, Toluene, Ethylbenzene, p-Xylene, m-Xylene, and o-Xylene, 82 groups of groundwater samples and 10 surface water samples collected from Guangzhou in Guangdong during 2005 to 2008 were tested by gas chromatography and mass spectrum(GC/MS). The result showed that the BTEX concentration in groundwater does not exceed the standard. The detection rate of BTEX is 14.63% in groundwater, and the total BTEX concentration is lower than 9.5 μg/L. Of 6 kinds of BTEX, toluene had the highest detection rate(12.20%) and detection value(9.5 μg/L), which was followed by Benzene, with the detection rate of 3.65%, and detection value of 4.9 μg/L respectively; most of samples with BTEX are distributed in Huangpu district, Baiyun district, Huadu district and other industrialized areas; this spatial distribution and urban distribution have obvious consistency. With economic development, plant expansion and population growth led to a large amount of waste water discharge, and infrastructure construction is lagging behind, indicating that rapid urbanization is a major driving force of BTEX in groundwater, and through the analysis of a typical area, it is found that benzene system surface water infiltration was an important source of BTEX in groundwater of Guangzhou.
文摘With the current,our country social economy rapid development,people's living standard and quality of life and therefore have got improved,at the same time,it is the concept of environmental protection and energy saving is also enhanced value,many fields in our country environmental protection and energysaving concept can be seen in the application,especially the application in building water supply and drainage design more widely,to protect the environment,to maximize the use of limited resources,how to reasonable use of water resources in building water supply and drainage construction,above is current the paper mainly discusses the problems in the construction field,this paper based on environmental protection and energy-saving concept,discusses its application in the building water supply and drainage design,for your reference.
文摘Background Cockroaches are an important indoor allergen source causing allergic rhinitis and asthma. The aim of this study was to investigate the cockroach prevalence in mainland of China and the cross-reactivity of IgE between cockroach and house dust mite allergen in Chinese patients.Methods The cockroach sensitization pattern was based on a skin prick test (SPT) obtained from a national multicenter prevalence study, in which 6304 patients from 25 allergy centers across China participated. Factors, including different regions of China, age, gender and the correlations between the American and German cockroaches and house dust mite Der p were investigated. Eighteen out of 1236 clinical sera from south China were selected to perform the cross-inhibition assay between house dust mites and cockroaches.Results Totally 25.7% of patients were SPT positive to the American cockroach (Periplaneta Americana, Per a) and 18.7% SPT positive to the German cockroach (Blattella germanica, Bla g). The prevalence of positive cockroach SPT was higher in southern than in northern China, higher in adults than in children, and higher in males than in females.Patients had relatively low levels of cockroach SPT reactions, mainly class 1 or 2. Of the SPT positive cockroach patients,88% were also SPT positive to house dust mite (Dermatophagoides pteronyssinus, Der p). An IgE cross-inhibition study confirmed that Der P sensitization could cause false positive SPT reactions against cockroach.Conclusions A relatively high prevalence of cockroach sensitivity was found in mainland of China. However, a cross-inhibition study showed that only a small number of patients appear to have Bla g and/or Per a as primary sensitizing source. The importance of cockroaches as a risk factor for sensitization and triggers of allergic symptoms in mainland of China needs to be further investigated.