期刊文献+
共找到33,642篇文章
< 1 2 250 >
每页显示 20 50 100
Prenatal Diagnosis of Proximal Femoral Focal Deficiency Combining Ultrasound and Computer Tomography
1
作者 Erica Stein Ciasca Fernando Maia Peixoto-Filho +3 位作者 Pedro Daltro Heron Werner Adriana Viana Renato Augusto Moreira de Sá 《Advances in Computed Tomography》 2013年第3期102-106,共5页
Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Compute... Four cases of proximal femoral focal deficiency (PFFD) in an otherwise healthy infant are described. Antenatal diagnosis was made at 27, 23, 23 and 18 weeks of gestation by routine ultrasound (US) examination. Computer Tomography (CT) was performed after 30 weeks of gestation and confirmed the images obtained by US. The diagnosis was confirmed after delivery. These cases illustrate the importance of combining US and CT to improve accuracy of prenatal diagnosis of skeletal disorders. 展开更多
关键词 PRENATAL Diagnosis ULTRASONOGRAPHY Imaging Three-Dimensional tomography x-Ray Computed Limb DEFORMITIES CONGENITAL
下载PDF
Reduction of the Beam Hardening Artifacts in the X-Ray Computer Tomography: Energy Discrimination with a Photon-Counting Detector
2
作者 Yukino Imura Takuto Yanagida +2 位作者 Hisashi Morii Hidenori Mimura Toru Aoki 《World Journal of Nuclear Science and Technology》 2012年第4期169-173,共5页
The material identification is a pressing requirement for the sensitive security applications. Dual-energy X-ray computer tomography (DXCT) has been investigated for material identification in the medical and security... The material identification is a pressing requirement for the sensitive security applications. Dual-energy X-ray computer tomography (DXCT) has been investigated for material identification in the medical and security fields. It requires two tomographic images at sufficiently different energies. To discriminate dangerous materials of light elements such as plastic bombs in luggage, it is needed to measure accurately with several tens of kilo electron volts where such materials exhibit significant spectral differences. However, CT images in that energy region often include artifacts from beam hardening. To reduce these artifacts, a novel reconstruction method has been investigated. It is an extension of the Al-gebraic Reconstruction Technique and Total Variation (ART-TV) method that reduces the artifacts in a lower-energy CT image by referencing it to an image obtained at higher energy. The CT image of a titanium sample was recon-structed using this method in order to demonstrate the artifact reduction capability. 展开更多
关键词 x-Ray computer tomography ARTIFACTS PHOTON COUNTING Iterative Reconstruction ART-TV Titanium Sample Security Applications
下载PDF
Measurement and analysis of defects in high-performance concrete with three-dimensional micro-computer tomography 被引量:8
3
作者 郭丽萍 Andrea Carpinteri +1 位作者 孙伟 秦文超 《Journal of Southeast University(English Edition)》 EI CAS 2009年第1期83-88,共6页
In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomogra... In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomography)is employed to quantitatively analyze the initial defects in four series of highperformance concrete (HPC)specimens with additions of different mineral admixtures. The nigh-resolution 3D images of microstructures and filtered defects are reconstructed by micro- CT software. The size distribution and volume fractions of initial defects are analyzed based on 3D and 2D micro-CT images. The analysis results are verified by experimental results of watersuction tests. The results show that the additions of mineral admixtures in concrete as cementitious materials greatly change the geometrical properties of the microstructures and the spatial features of defects by physical-chemistry actions of these mineral admixtures. This is the major cause of the differences between the mechanical behaviors of HPC with and without mineral admixtures when the water-to-binder ratio and the size distribution of aggregates are constant. 展开更多
关键词 high-performance concrete DEFECT MICROSTRUCTURE x- ray micro-focus computer tomography mineral admixtures
下载PDF
Computed tomography versus transthoracic echocardiography in the detection of complex congenial heart diseases in china:a meta-analysis
4
作者 畅智慧 LIN Kun +3 位作者 DU Xiao-li YIN Xiao-li LU Zhao 刘兆玉 《放射学实践》 2012年第11期1168-1173,共6页
Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochran... Objective:To perform a meta-analysis to evaluate the diagnostic performance of computed tomography(CT) and transthoracic echocardiography(TTE) in complex congenital heart diseases(CHD) in China.Methods:MEDLINE,Cochrane library and China National Knowledge Infrastructure(CNKI) database from January 1966 to October 2010,were searched for initial studies in China.All the studies,published in English or Chinese,used TTE,CT,or both as diagnostic tests for CHD and reported the rate of true-positive,true-negative,false-positive and false-negative diagnoses of CHD from TTE and CT findings with the surgical results as the 'gold-standard'(15 studies,XX patients) were collected.The statistic software package,'Meta-Disc 1.4',was used to conduct data analysis.A covariate analysis was used to evaluate the influence of patient or study-related factors on sensitivity.Results:Pooled sensitivity for diagnosis of CHD were 95% [95% confidence interval(CI):94%~96%] for CT studies and 87%(95% CI:85%~88%) for TTE studies.The difference between the pooled sensitivity of CT and that of TTE was statistically significant(P<0.001).TTE had higher sensitivity [0.96(95% CI:0.94~0.97)] for cardiac malformation but lower sensitivity [0.78(95% CI:0.76~0.81)] for extracardiac malformation than CT.Conclusion:CT can provide added diagnostic information compared with TTE in patients with CHD in China,especially for patients suspected of extracardiac malformation. 展开更多
关键词 ECHOCARDIOGRAPHY tomography x-ray computed Heart Defects Congenital META-ANALYSIS
下载PDF
Clinical significance of mesenteric panniculitis-like abnormalities on abdominal computerized tomography in patients with malignant neoplasms 被引量:8
5
作者 Eli D Ehrenpreis Grigory Roginsky Richard M Gore 《World Journal of Gastroenterology》 SCIE CAS 2016年第48期10601-10608,共8页
AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric pan... AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric panniculitis from January 2005 to August 2010 were identified in the Radnet(Rad Net Corporation, Los Angeles, CA) database. Patients with a new or known diagnosis of a malignancy were included for this analysis. Longitudinal clinical histories were obtained from electronic medical records.RESULTS In total, 147794 abdominal CT scans were performed during the study period. Three hundred and fiftynine patients had mesenteric panniculitis(MP)-like abnormalities on their abdominal CT. Of these patients, 81 patients(22.6%) had a known history of cancer at the time of their CT scan. Nineteen(5.3%) had a new diagnosis of cancer in concurrence with their CT, but the majority of these(14/19, 74%) were undergoing CT as part of a malignancy evaluation. Lymphomas were the most common cancers associated with MPlike findings on CT(36 cases, 36%), with follicular lymphoma being the most frequent subtype(17/36). A variety of solid tumors, most commonly prostate(7) and renal cell cancers(6) also were seen. CT follow up was obtained in 56 patients. Findings in the mesentery were unchanged in 45(80%), worsened in 6(11%), and improved in 5 patients(9%). Positron emission tomography(PET) scans performed in 44 patients only showed a positive uptake in the mesenteric mass in 2 patients(5%). CONCLUSION A new diagnosis of cancer is uncommon in patients with CT findings suggestive of MP. MP-like mesenteric abnormalities on CT generally remain stable in patients with associated malignancies. PET scanning is not recommended in the evaluation of patients with mesenteric panniculitis-like findings on CT. 展开更多
关键词 PANNICULITIS PERITONEAL x ray Neoplasms Computed tomography Small INTESTINE Misty MESENTERY Lymphoma tomography Positron emission tomography
下载PDF
Gastric hepatoid adenocarcinoma: A computed tomography report of six cases 被引量:7
6
作者 An Ren Feng Cai +4 位作者 Yan-Ning Shang En-Sen Ma Zhen-Guo Huang Wu Wang Jie Luo 《World Journal of Gastroenterology》 SCIE CAS 2014年第40期15001-15006,共6页
We describe the computed tomography(CT)imaging findings in six cases(five males and one female;age range 61-78 years;mean age 67.3 years)with histologically proven hepatoid adenocarcinoma of the stomach(HAS).Five of t... We describe the computed tomography(CT)imaging findings in six cases(five males and one female;age range 61-78 years;mean age 67.3 years)with histologically proven hepatoid adenocarcinoma of the stomach(HAS).Five of the six patients had elevated serum alpha-fetoprotein levels.The most common type of gross appearance HAS on CT is a polypoid mass(83%,5/6).The most common contrast enhancement pattern was heterogeneous.All six patients had a regional lymphadenopathy larger than 6 mm in its short axis.Liver metastases(n=3)were noted.Venous tumor thrombosis was identified in the portal vein(n=2)of the regions near primary gastric tumors or metastatic masses.Our findings suggest in an elderly,male patients with a large heterogeneous enhancement tumor,the presence of distant metastases,regional lymphadenopathy and characteristically increased serum alphafetoprotein levels indicates a high likelihood of HAS. 展开更多
关键词 STOMACH Hepatoid adenocarcinoma tomography x-ray METASTASIS Portal venous thrombosis
下载PDF
Microstructure Evolution of Sandstone Cemented by Microbe Cement Using X-ray Computed Tomography 被引量:4
7
作者 RONG Hui QIAN Chunxiang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1134-1139,共6页
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica... The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone. 展开更多
关键词 microbe cement bio-sandstone microstructure evolution x-ray computed tomography CALCITE
下载PDF
Infective severe acute pancreatitis:A comparison of ^(99m)Tc-ciprofloxacin scintigraphy and computed tomography 被引量:2
8
作者 Jian-Hua Wang Gao-Feng Sun +5 位作者 Jian Zhang Cheng-Wei Shao Chang-Jing Zuo Jun Hao Jian-Ming Zheng Xiao-Yuan Feng 《World Journal of Gastroenterology》 SCIE CAS 2013年第30期4897-4906,共10页
AIM:To evaluate 99mTc-ciprofloxacin scintigraphy compared with computed tomography(CT)for detecting secondary infections associated with severe acute pancreatitis(SAP)in swine.METHODS:Six healthy swine were assigned t... AIM:To evaluate 99mTc-ciprofloxacin scintigraphy compared with computed tomography(CT)for detecting secondary infections associated with severe acute pancreatitis(SAP)in swine.METHODS:Six healthy swine were assigned to a normal control group(group A,n = 6).SAP was induced in group B(n = 9)and C(n = 18),followed by inoculation of the resulting pancreatic necroses with inactive Escherichia coli(E.coli)(group B)and active E.coli(group C),respectively.At 7 d after inoculation,a CT scan and a series of analyses using infecton imaging(at 0.5,1,2,3,4 and 6 h after the administration of 370 MBq of intravenous infecton)were performed.The scintigrams were visually evaluated and semi-quantitatively analyzed using region of interest assignments.The differences in infecton uptake and changes in the lesion-background radioactive count ratios(L/B)in the 3 groups were recorded and compared.After imaging detection,histopathology and bacterial examinations were performed,and infected SAP was regarded as positive.The imaging findings were compared with histopathological and bacteriological results.RESULTS:In group A,6 animals survived without infection in the pancreas.In group B,7/9 swine survived and one suffered from infection.In group C,15/18 animals survived with infection.Hence,the number of normal,non-infected and infected SAP swine was 6,6 and 16,respectively.The sensitivity,specificity,accuracy,positive predictive value and negative predictive value of the infecton method were 93.8%(15/16),91.7%(11/12),92.9%(26/28),93.8%(15/16)and 91.7%(11/12),whereas these values for CT were 12.5%(2/16),100.0%(12/12),50.0%(14/28),100.0%(2/2)and 46.2%(12/26),respectively.The changes in L/B for the infected SAP were significantly different from those of the non-infected and normal swine(P < 0.001).The mean L/B of the infectious foci at 0.5,1,2,3,4 and 6 h was 1.17 ± 0.10,1.71 ± 0.30,2.46 ± 0.45,3.36 ± 0.33,2.04 ± 0.37 and 1.1988 ± 0.09,respectively.At 3 h,the radioactive counts(2350.25 ± 602.35 k)and the mean L/B of the infectious foci were significantly higher than that at 0.5 h(P = 0.000),1 h(P = 0.000),2 h(P = 0.04),4 h(P = 0.000)and 6 h(P = 0.000).CONCLUSION:99m Tc-ciprofloxacin scintigraphy may be an effective procedure for detecting SAP secondary infections with higher sensitivity and accuracy than CT. 展开更多
关键词 PANCREATITIS Infection RADIONUCLIDE imaging CIPROFLOxACIN x-ray COMPUTED tomography
下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
9
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution x-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Three dimensional distribution of surfactant in microspheres revealed by synchrotron radiation X-ray microcomputed tomography 被引量:2
10
作者 Li Wu Manli Wang +7 位作者 Vikramjeet Singh Haiyan Li Zhen Guo Shuangying Gui Peter York Tiqiao Xiao Xianzhen Yin Jiwen Zhang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2017年第4期326-334,共9页
This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion s... This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion solvent evaporation method using acetone and liquid paraffin system containing sucrose stearate as a surfactant. The fabricated microspheres were evaluated for encapsulation efficiency, particle size, production yield, and in vitro release characteristics. The internal structures of microspheres were characterized using synchrotron radiation X-ray microcomputed tomography(SR-μCT). The enhanced contrast made the sucrose stearate distinguished from Eudragit to have its three dimensional(3D) distribution. Results indicated that the content and concentration determined the state of sucrose stearate and had significant influences on the release kinetics of protein. The dispersity of sucrose stearate was the primary factor that controlled the structure of the microspheres and further affected the encapsulation efficiency, effective drug loading, as well as in vitro release behavior. In conclusion, the 3D internal distribution of surfactant in microspheres and its effects on protein release behaviors have been revealed for the first time. The highly resolved 3D architecture provides new evidence for the deep understanding of the microsphere formation mechanism. 展开更多
关键词 Three dimensional SYNCHROTRON radiation x-RAY microcomputed tomography DISTRIBUTION MICROSPHERE SUCROSE STEARATE
下载PDF
Full-field mapping of internal strain distribution in red sandstone specimen under compression using digital volumetric speckle photography and X-ray computed tomography 被引量:5
11
作者 Lingtao Mao Jianping Zuo +1 位作者 Zexun Yuan Fu-Pen Chiang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第2期136-146,共11页
It is always desirable to know the interior deformation pattern when a rock is subjected to mechanicalload. Few experimental techniques exist that can represent full-field three-dimensional (3D) straindistribution i... It is always desirable to know the interior deformation pattern when a rock is subjected to mechanicalload. Few experimental techniques exist that can represent full-field three-dimensional (3D) straindistribution inside a rock specimen. And yet it is crucial that this information is available for fully understandingthe failure mechanism of rocks or other geomaterials. In this study, by using the newlydeveloped digital volumetric speckle photography (DVSP) technique in conjunction with X-ray computedtomography (CT) and taking advantage of natural 3D speckles formed inside the rock due to materialimpurities and voids, we can probe the interior of a rock to map its deformation pattern under load andshed light on its failure mechanism. We apply this technique to the analysis of a red sandstone specimenunder increasing uniaxial compressive load applied incrementally. The full-field 3D displacement fieldsare obtained in the specimen as a function of the load, from which both the volumetric and the deviatoricstrain fields are calculated. Strain localization zones which lead to the eventual failure of the rock areidentified. The results indicate that both shear and tension are contributing factors to the failuremechanism. 2015 Institute of Rock and Soil Mechanics, Chinese Academy of Sciences. Production and hosting byElsevier B.V. All rights reserved. 展开更多
关键词 Red sandstone Strain localization Uniaxial compression Digital volumetric speckle photography(DVSP) x-ray micro-tomography
下载PDF
X-ray tomography study on the structure of the granular random loose packing 被引量:1
12
作者 邢义 邱宇鹏 +2 位作者 王智 叶佳超 李向亭 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第8期215-218,共4页
Random loose packing is the minimum-density granular packing which can maintain mechanical stability. In this study, x-ray tomography is used to investigate the internal structure of an isotropically prepared random l... Random loose packing is the minimum-density granular packing which can maintain mechanical stability. In this study, x-ray tomography is used to investigate the internal structure of an isotropically prepared random loose packing through a special apparatus to minimize the effect of gravity. It is found that the minimum packing density is around 0.587. The microscopic structural analysis of the packing is also carried out. 展开更多
关键词 granular systems random loose packing x-ray tomography
下载PDF
Fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios 被引量:1
13
作者 张晓丹 夏成杰 +1 位作者 肖相辉 王宇杰 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第4期373-376,共4页
We present a fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can... We present a fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can complete a high- resolution tomography scan within a short period of time, after which the three-dimensional (3D) packing structure can be obtained for the subsequent structural analysis. The image phase-retrieval procedure has been implemented to enhance the image contrast. We systematically investigated the effects of particle shape and aspect ratio on the structural properties including packing density and contact number. It turns out that large aspect ratio rod packings will have wider distributions of free volume fraction and larger mean contact numbers. 展开更多
关键词 synchrotron x-ray imaging tomography rod packing structure
下载PDF
X-ray Computed Tomography Characterization of 3D Tufted Twill Textile Composite for Aerostructures 被引量:1
14
作者 A.Saboktakin M.Shahrouz +1 位作者 T.Vu-Khanh J.Bicerano 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期7-13,共7页
Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the f... Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the fracture behavior of 3D tufted textile composites.X-ray computed tomography as a non-destructive evaluation method is appropriate to detect damage locations and identify their progression in 3D textile composites.Destructive methods such as sectioning toward observing damage provide valuable information about damage patterns.The results of this research could be utilized to evaluate the initial cause of rupture in 3D tufted composites used in aerospace structures and analyze fracture modes and damage progression. 展开更多
关键词 x-ray COMPUTED tomography DAMAGE CHARACTERIZATION 3D composite TExTILE PREFORM
下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
15
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
下载PDF
Study of sawtooth oscillations on the HT-7 tokamak using 2D tomography of soft x-ray signal 被引量:1
16
作者 马天鹏 胡立群 +8 位作者 万宝年 阮怀林 高翔 甄香君 周立武 孙有文 陈忠勇 林士耀 孔伟 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第10期2061-2067,共7页
It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmo... It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmonic reconstruction method, and using the singular value decomposition to analyse the data from soft x-ray cameras. By these two arrays, 2D image reconstruction of soft x-ray emissivity can be obtained without assumption of plasma rigid rotation. Tomographic reconstruction of the m=1 mode structure is obtained during the precursor oscillation of the sawtooth crash. The crescent-shaped mode structure appearing on the contour map of the soft x-ray emissivity is consistent with the quasiinterchange mode. The characteristics of the m=1/n=1 mode structure observed in the soft x-ray tomography are as follows: the magnetic surface is made up of the crescent-shaped “hot core” and the circular “cold bubble”. The structure of the magnetic surface rotates in the direction of the electron diamagnetic drift and the rotation frequency is the oscillation frequency of soft x-ray signals. 展开更多
关键词 soft x-ray tomography sawtooth oscillation singular value decomposition (SVD)
下载PDF
X-Ray Computed Tomography for Root Quantification 被引量:1
17
作者 Bente Foereid 《Open Journal of Soil Science》 2015年第7期145-148,共4页
Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and we... Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and weight and length were determined by conventional means. Root volume and surface area were then calculated from the 3D images using state of the art software and methodology, and the measured and calculated measures were correlated. The only strong and significant correlation was between measured weight and calculated volume for mutants without root hairs. It is concluded that the software cannot segment out very small roots, but segmentation accuracy also depends on root structure in some unknown way. Any study using X-ray computed tomography to quantify roots as they grow in situ should start with a calibration for the conditions in question. 展开更多
关键词 ROOTS 3D IMAGE x-RAY COMPUTED tomography
下载PDF
Fast forward modeling of muon transmission tomography based on model voxelization ray energy loss projection
18
作者 Zhang Rong-Qing Xi Zhen-Zhu +2 位作者 Liu Wei Wang He Yang Zi-Yan 《Applied Geophysics》 SCIE CSCD 2022年第3期395-408,471,共15页
To solve the problems associated with low resolution and high computational effort infinite time,this paper proposes a fast forward modeling method for muon energy loss transmission tomography based on a model voxeliza... To solve the problems associated with low resolution and high computational effort infinite time,this paper proposes a fast forward modeling method for muon energy loss transmission tomography based on a model voxelization energy loss projection algorithm.First,the energy loss equation for muon transmission tomography is derived from the Bethe–Bloch formula,and the imaging region is then dissected into several units using the model voxelization method.Thereafter,the three-dimensional(3-D)imaging model is discretized into parallel and equally spaced two-dimensional(2-D)slices using the model layering method to realize a dimensional reduction of the 3-D volume data and accelerate the forward calculation speed.Subsequently,the muon energy loss transmission tomography equation is discretized using the ray energy loss projection method to establish a set of energy loss equations for the muon penetration voxel model.Finally,the muon energy loss values at the outgoing point are obtained by solving the projection coefficient matrix of the ray length-weighted model,achieving a significant reduction in the number of muons and improving the computational efficiency.A comparison of our results with the simulation results based on the Monte Carlo method verifies the accuracy and effectiveness of the algorithm proposed in this paper.The metallic mineral identification tests show that the proposed algorithm can quickly identify high-density metallic minerals.The muon energy loss response can accurately identify the boundary of the anomalies and their spatial distribution characteristics. 展开更多
关键词 Muon transmission tomography model voxelization ray energy loss projection fast forward modeling Monte Carlo simulation
下载PDF
Soft X-ray Tomography on HT-7
19
作者 陈开云 胡立群 +2 位作者 丁玥 马天鹏 段艳敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期472-476,共5页
The soft X-ray imaging system on HT-7 is introduced. Fourier-Bessel expansion method is used to reconstruct the soft X-ray emission distribution. Simulation results show that the inversion accuracy is associated with ... The soft X-ray imaging system on HT-7 is introduced. Fourier-Bessel expansion method is used to reconstruct the soft X-ray emission distribution. Simulation results show that the inversion accuracy is associated with the angular expansion limit and the hot core displacement. In addition, tomographic results of sawtooth oscillations in a typical low hybrid current drive (LHCD) plasma are presented. It is shown that the reconstructions are reliable to analyze the perturbative mode and the evolution. 展开更多
关键词 tomography SAWTOOTH soft x-ray
下载PDF
Identification of m = 2 competent mode of complex magneto-hydro-dynamics activities during internal soft disruption based on singular value decomposition and tomography of soft-X-ray emission on the HT-7 tokamak
20
作者 徐立清 胡立群 +8 位作者 李二众 陈开云 刘志远 陈晔斌 张继宗 周瑞杰 杨茂 毛松涛 段艳敏 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期418-423,共6页
In this paper,the singular value decomposition(SVD) method as a filter is applied before the tomographic inversion of soft-X-ray emission.Series of 'filtered' signals including specific chronos and topos are obtai... In this paper,the singular value decomposition(SVD) method as a filter is applied before the tomographic inversion of soft-X-ray emission.Series of 'filtered' signals including specific chronos and topos are obtained.(Here,chronos and topos are the decomposed spatial vectors and the decomposed temporal vectors,respectively).Given specific magnetic flux function with coupling m = 1 and m = 2 modes,the line-integrated soft-X-ray signals at all chords have been obtained.Then m = 1 and m = 2 modes have been identified by tomography of simulated 'filtered' signals extracted by the SVD method.Finaly,using the experimental line-integrated soft-X-ray signals,m = 2 competent mode of complex magnetohydrodynamics(MHD) activities during internal soft disruption is observed.This result demonstrates that m = 2 mode plays an important role in internal disruption(Here,m is the poloidal mode number). 展开更多
关键词 singular value decomposition DISRUPTION soft-x-ray tomography TOKAMAK
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部