期刊文献+
共找到69,651篇文章
< 1 2 250 >
每页显示 20 50 100
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
1
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 X-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering X-ray source Monte Carlo simulation
下载PDF
Aflibercept combined with triamcinolone acetonide in the treatment of diabetic macular edema:optical coherence tomography and optical coherence tomography angiography
2
作者 De-Shuang Li Hong-Xia Liao +4 位作者 Chuan-He Zhang Jian-Guo Huang Wei Chen Jing-Lin Zhang Bo Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期670-675,共6页
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone... AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography hyperreflective foci subretinal fluid foveal avascular zone AFLIBERCEPT
下载PDF
Energy spectrum computed tomography multi-parameter imaging in preoperative assessment of vascular and neuroinvasive status in gastric cancer
3
作者 Jing Wang Jian-Cheng Liang +1 位作者 Fa-Te Lin Jun Ma 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2511-2520,共10页
BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent ye... BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent years,energy spectrum computed tomography(CT)multiparameter imaging technology has been gradually applied in clinical practice because of its advantages in tissue contrast and lesion detail display.AIM To explore and analyze the value of multiparameter energy spectrum CT imaging in the preoperative assessment of vascular invasion(LVI)and nerve invasion(PNI)in GC patients.METHODS Data from 62 patients with GC confirmed by pathology and accompanied by energy spectrum CT scanning at our hospital between September 2022 and September 2023,including 46 males and 16 females aged 36-71(57.5±9.1)years,were retrospectively collected.The patients were divided into a positive group(42 patients)and a negative group(20 patients)according to the presence of LVI/PNI.The CT values(CT40 keV,CT70 keV),iodine concentration(IC),and normalized IC(NIC)of lesions in the upper energy spectrum CT images of the arterial phase,venous phase,and delayed phase 40 and 70 keV were measured,and the slopes of the energy spectrum curves[K(40-70)]from 40 to 70 keV were calculated.Arterial Core Tip:To investigate the application value of multiparameter energy spectrum computed tomography(CT)imaging in the preoperative assessment of vascular and nerve infiltration in patients with gastric cancer(GC).The imaging data of GC patients were retrospectively analyzed to evaluate the accuracy and sensitivity of CT for identifying and quantifying vascular and nerve infiltration and for comparison with postoperative pathological results.The purpose of this study was to verify the clinical feasibility and potential advantages of multiparameter energy spectrum CT imaging in guiding preoperative diagnosis and treatment decision-making and to provide a new imaging basis for improving the diagnostic accuracy and prognosis of GC patients. 展开更多
关键词 tomography X-ray computer Energy spectrum computed tomography Gastric cancer Vascular invasion Nerve invasion Cross-sectional study
下载PDF
Computed tomography for prediction of esophageal variceal bleeding
4
作者 Mohammed Elhendawy Ferial Elkalla 《World Journal of Gastrointestinal Endoscopy》 2024年第3期175-177,共3页
This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is ... This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is one of the most common and severe complications related to portal hypertension(PH).Despite marked advances in its management during the last three decades,EVB is still associated with significant morbidity and mortality.The risk of first EVB is related to the severity of both PH and liver disease,and to the size and endoscopic appearance of esophageal varices.Indeed,hepatic venous pressure gradient(HVPG)and esophagogastroduodenoscopy(EGD)are currently recognized as the“gold standard”and the diagnostic reference standard for the prediction of EVB,respectively.However,HVPG is an invasive,expensive,and technically complex procedure,not widely available in clinical practice,whereas EGD is mainly limited by its invasive nature.In this scenario,computed tomography(CT)has been recently proposed as a promising modality for the non-invasive prediction of EVB.While CT serves solely as a diagnostic tool and cannot replace EGD or HVPG for delivering therapeutic and physiological information,it has the potential to enhance the prediction of EVB more effectively when combined with liver disease scores,HVPG,and EGD.However,to date,evidence concerning the role of CT in this setting is still lacking,therefore we aim to summarize and discuss the current evidence concerning the role of CT in predicting the risk of EVB. 展开更多
关键词 Esophageal variceal bleeding Variceal upper gastrointestinal bleeding Portal hypertension Computed tomography Computed tomography angiography
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
5
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report 被引量:2
6
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst Computer tomography MISDIAGNOSIS HEMORRHAGE INFECTION Case report
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
7
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography OCT-compatible instruments glaucoma surgery TRABECULECTOMY CANALOPLASTY
下载PDF
Preoperative prediction of lymphovascular and perineural invasion in gastric cancer using spectral computed tomography imaging and machine learning 被引量:1
8
作者 Hui-Ting Ge Jian-Wu Chen +5 位作者 Li-Li Wang Tian-Xiu Zou Bin Zheng Yuan-Fen Liu Yun-Jing Xue Wei-Wen Lin 《World Journal of Gastroenterology》 SCIE CAS 2024年第6期542-555,共14页
BACKGROUND Lymphovascular invasion(LVI)and perineural invasion(PNI)are important prognostic factors for gastric cancer(GC)that indicate an increased risk of metastasis and poor outcomes.Accurate preoperative predictio... BACKGROUND Lymphovascular invasion(LVI)and perineural invasion(PNI)are important prognostic factors for gastric cancer(GC)that indicate an increased risk of metastasis and poor outcomes.Accurate preoperative prediction of LVI/PNI status could help clinicians identify high-risk patients and guide treatment deci-sions.However,prior models using conventional computed tomography(CT)images to predict LVI or PNI separately have had limited accuracy.Spectral CT provides quantitative enhancement parameters that may better capture tumor invasion.We hypothesized that a predictive model combining clinical and spectral CT parameters would accurately preoperatively predict LVI/PNI status in GC patients.AIM To develop and test a machine learning model that fuses spectral CT parameters and clinical indicators to predict LVI/PNI status accurately.METHODS This study used a retrospective dataset involving 257 GC patients(training cohort,n=172;validation cohort,n=85).First,several clinical indicators,including serum tumor markers,CT-TN stages and CT-detected extramural vein invasion(CT-EMVI),were extracted,as were quantitative spectral CT parameters from the delineated tumor regions.Next,a two-step feature selection approach using correlation-based methods and information gain ranking inside a 10-fold cross-validation loop was utilized to select informative clinical and spectral CT parameters.A logistic regression(LR)-based nomogram model was subsequently constructed to predict LVI/PNI status,and its performance was evaluated using the area under the receiver operating characteristic curve(AUC).RESULTS In both the training and validation cohorts,CT T3-4 stage,CT-N positive status,and CT-EMVI positive status are more prevalent in the LVI/PNI-positive group and these differences are statistically significant(P<0.05).LR analysis of the training group showed preoperative CT-T stage,CT-EMVI,single-energy CT values of 70 keV of venous phase(VP-70 keV),and the ratio of standardized iodine concentration of equilibrium phase(EP-NIC)were independent influencing factors.The AUCs of VP-70 keV and EP-NIC were 0.888 and 0.824,respectively,which were slightly greater than those of CT-T and CT-EMVI(AUC=0.793,0.762).The nomogram combining CT-T stage,CT-EMVI,VP-70 keV and EP-NIC yielded AUCs of 0.918(0.866-0.954)and 0.874(0.784-0.936)in the training and validation cohorts,which are significantly higher than using each of single independent factors(P<0.05).CONCLUSION The study found that using portal venous and EP spectral CT parameters allows effective preoperative detection of LVI/PNI in GC,with accuracy boosted by integrating clinical markers. 展开更多
关键词 Spectral computed tomography Gastric cancer Lymphovascular invasion Perineural invasion
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients 被引量:1
9
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Lymphatic plastic bronchitis and primary chylothorax: A study based on computed tomography lymphangiography 被引量:1
10
作者 Xing-Peng Li Yan Zhang +4 位作者 Xiao-Li Sun Kun Hao Meng-Ke Liu Qi Hao Ren-Gui Wang 《World Journal of Clinical Cases》 SCIE 2024年第14期2350-2358,共9页
BACKGROUND This study presents an evaluation of the computed tomography lymphangio-graphy(CTL)features of lymphatic plastic bronchitis(PB)and primary chylotho-rax to improve the diagnostic accuracy for these two disea... BACKGROUND This study presents an evaluation of the computed tomography lymphangio-graphy(CTL)features of lymphatic plastic bronchitis(PB)and primary chylotho-rax to improve the diagnostic accuracy for these two diseases.AIM To improve the diagnosis of lymphatic PB or primary chylothorax,a retrospective analysis of the clinical features and CTL characteristics of 71 patients diagnosed with lymphatic PB or primary chylothorax was performed.METHODS The clinical and CTL data of 71 patients(20 with lymphatic PB,41 with primary chylothorax,and 10 with lymphatic PB with primary chylothorax)were collected retrospectively.CTL was performed in all patients.The clinical manifestations,CTL findings,and conventional chest CT findings of the three groups of patients were compared.The chi-square test or Fisher's exact test was used to compare the differences among the three groups.A difference was considered to be statistically significant when P<0.05.RESULTS(1)The percentages of abnormal contrast medium deposits on CTL in the three groups were as follows:Thoracic duct outlet in 14(70.0%),33(80.5%)and 8(80.0%)patients;peritracheal region in 18(90.0%),15(36.6%)and 8(80.0%)patients;pleura in 6(30.0%),33(80.5%)and 9(90.0%)patients;pericardium in 6(30.0%),6(14.6%)and 4(40.0%)patients;and hilum in 16(80.0%),11(26.8%)and 7(70.0%)patients;and(2)the abnormalities on conven-tional chest CT in the three groups were as follows:Ground-glass opacity in 19(95.0%),18(43.9%)and 8(80.0%)patients;atelectasis in 4(20.0%),26(63.4%)and 7(70.0%)patients;interlobular septal thickening in 12(60.0%),11(26.8%)and 3(30.0%)patients;bronchovascular bundle thickening in 14(70.0%),6(14.6%)and 4(40.0%)patients;localized mediastinal changes in 14(70.0%),14(34.1%),and 7(70.0%)patients;diffuse mediastinal changes in 6(30.0%),5(12.2%),and 3(30.0%)patients;cystic lesions in the axilla in 2(10.0%),6(14.6%),and 2(20.0%)patients;and cystic lesions in the chest wall in 0(0%),2(4.9%),and 2(4.9%)patients.CONCLUSION CTL is well suited to clarify the characteristics of lymphatic PB and primary chylothorax.This method is an excellent tool for diagnosing these two diseases. 展开更多
关键词 LYMPHATIC Plastic bronchitis Primary chylothorax Direct lymphangiography Computed tomography lymphangiography
下载PDF
In-situ X-ray computed tomography tensile tests and analysis of damage mechanism and mechanical properties in laser powder b e d fused Invar 36 alloy 被引量:1
11
作者 Qidong Yang Shuo Yang +6 位作者 Shiyu Ma Junhan Zhou Ye Zhou Rongzheng Huang Kai Wei Zhaoliang Qu Xujing Yang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2024年第8期29-46,共18页
Laser powder bed fusion(LPBF)is a potential additive manufacturing process to manufacture Invar 36 alloy components with complicated geometry.Whereas it inevitably introduces specific microstructures and pore defects,... Laser powder bed fusion(LPBF)is a potential additive manufacturing process to manufacture Invar 36 alloy components with complicated geometry.Whereas it inevitably introduces specific microstructures and pore defects,which will further influence the mechanical properties.Hence,aiming at exploring the LPBF process-related microstructures and pore defects,and especially their influences on the damage mechanism and mechanical properties,Invar 36 alloy was manufactured by LPBF under designed different laser scanning speeds.The microstructure observations reveal that higher scanning speeds lead to equiaxed and short columnar grains with higher dislocation density,while lower scanning speeds result in elongated columnar grains with lower dislocation density.The pore defects analyzed by X-ray computed tomography(XCT)suggest that the high laser scanning speed gives rise to numerous lamellar and large lack-of-fusion(LOF)pores,and the excessively low laser scanning speed produces relatively small keyhole pores with high sphericity.Moreover,the insitu XCT tensile tests were originally performed to evaluate the damage evolution and failure mechanism.Specifically,high laser scanning speed causes brittle fracture due to the rapid growth and coalescence of initial lamellar LOF pores along the scan-ning direction.Low laser scanning speed induces ductile fracture originating from unstable depressions in the surfaces,while metallurgical and keyhole pores have little impact on damage evolution.Eventually,the process-structure-property correlation is established.The presence of high volume fraction of lamel-lar LOF pores,resulting from high scanning speed,leads to inferior yield strength and ductility.Besides,specimens without LOF pores exhibit larger grain sizes and lower dislocation density at decreased scanning speeds,slightly reducing yield strength while slightly enhancing ductility.This understanding lays the foundation for widespread applications of LPBF-processed Invar 36 alloy. 展开更多
关键词 Invar 36 alloy Laser powder bed fusion Microstructure Pore defects Mechanical property X-ray tomography in-situ tensile test
原文传递
Computed tomography-based nomogram of Siewert type Ⅱ/Ⅲ adenocarcinoma of esophagogastric junction to predict response to docetaxel, oxaliplatin and S-1 被引量:1
12
作者 Chuan-Qinyuan Zhou Dan Gao +7 位作者 Yan Gui Ning-Pu Li Wen-Wen Guo Hai-Ying Zhou Rui Li Jing Chen Xiao-Ming Zhang Tian-Wu Chen 《World Journal of Radiology》 2024年第1期9-19,共11页
BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on ba... BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS. 展开更多
关键词 Esophagogastric junction ADENOCARCINOMA Neoadjuvant chemotherapy RESPONSE tomography X-ray computed Predictor
下载PDF
Three-dimensional choroidal vascularity index and choroidal thickness in fellow eyes of acute and chronic primary angle-closure using swept-source optical coherence tomography 被引量:1
13
作者 Hai-Li Huang Guan-Hong Wang +1 位作者 Liang-Liang Niu Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期42-52,共11页
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of... AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma. 展开更多
关键词 choroidal thickness choroidal vascularity index swept-source optical coherence tomography acute primary angle-closure chronic primary angle-closure glaucoma
下载PDF
Intravascular photoacoustic and optical coherence tomography imaging dual-mode system for detecting spontaneous coronary artery dissection: A feasibility study 被引量:1
14
作者 Yongwei Wang Yuyang Wan Zhongjiang Chen 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期77-86,共10页
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ... In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications. 展开更多
关键词 Spontaneous coronary artery dissection(SCAD) intravascular optical coherence tomography(IVOCT) intravascular photoacoustic imaging(IVPAI)
下载PDF
Remnant Paleoproterozoic Subduction or Lithospheric Drip Initiation at the Yilgarn Craton Margin:Constraints from P-wave Tomography
15
作者 XU Xiaobing WANG Kun +2 位作者 YANG Dinghui ZHAO Liang YUAN Huaiyu 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2024年第S01期72-74,共3页
The Paleoproterozoic was a critical time in whether modern-style plate tectonics had become globally dominant(e.g.,Wan et al.,2020).The Capricorn Orogen witnessed the assembly of the Pilbara and Yilgarn Cratons and an... The Paleoproterozoic was a critical time in whether modern-style plate tectonics had become globally dominant(e.g.,Wan et al.,2020).The Capricorn Orogen witnessed the assembly of the Pilbara and Yilgarn Cratons and an exotic microcontinent,the Glenburgh Terrane,to form the West Australia Craton(WAC)through two collisional orogenic events,the 2215–2145 Ma Ophthalmian and 2005–1950 Ma Glenburgh Orogenies(Johnson et al.,2013;Fig.1).Compared to other Proterozoic orogenic belts in Australia,the Capricorn Orogen preserves‘complete'opposing continental margin successions,together with intervening arc fragments associated with oceanic closure and foreland basins associated with collisional loading(Cawood et al.,2009). 展开更多
关键词 P-wave tomography finite-frequency method SUBDUCTION Capricorn Orogen
下载PDF
A deep learning model based on contrast-enhanced computed tomography for differential diagnosis of gallbladder carcinoma
16
作者 Fei Xiang Qing-Tao Meng +4 位作者 Jing-Jing Deng Jie Wang Xiao-Yuan Liang Xing-Yu Liu Sheng Yan 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第4期376-384,共9页
Background:Gallbladder carcinoma(GBC)is highly malignant,and its early diagnosis remains difficult.This study aimed to develop a deep learning model based on contrast-enhanced computed tomography(CT)images to assist r... Background:Gallbladder carcinoma(GBC)is highly malignant,and its early diagnosis remains difficult.This study aimed to develop a deep learning model based on contrast-enhanced computed tomography(CT)images to assist radiologists in identifying GBC.Methods:We retrospectively enrolled 278 patients with gallbladder lesions(>10 mm)who underwent contrast-enhanced CT and cholecystectomy and divided them into the training(n=194)and validation(n=84)datasets.The deep learning model was developed based on ResNet50 network.Radiomics and clinical models were built based on support vector machine(SVM)method.We comprehensively compared the performance of deep learning,radiomics,clinical models,and three radiologists.Results:Three radiomics features including LoG_3.0 gray-level size zone matrix zone variance,HHL firstorder kurtosis,and LHL gray-level co-occurrence matrix dependence variance were significantly different between benign gallbladder lesions and GBC,and were selected for developing radiomics model.Multivariate regression analysis revealed that age≥65 years[odds ratios(OR)=4.4,95%confidence interval(CI):2.1-9.1,P<0.001],lesion size(OR=2.6,95%CI:1.6-4.1,P<0.001),and CA-19-9>37 U/mL(OR=4.0,95%CI:1.6-10.0,P=0.003)were significant clinical risk factors of GBC.The deep learning model achieved the area under the receiver operating characteristic curve(AUC)values of 0.864(95%CI:0.814-0.915)and 0.857(95%CI:0.773-0.942)in the training and validation datasets,which were comparable with radiomics,clinical models and three radiologists.The sensitivity of deep learning model was the highest both in the training[90%(95%CI:82%-96%)]and validation[85%(95%CI:68%-95%)]datasets.Conclusions:The deep learning model may be a useful tool for radiologists to distinguish between GBC and benign gallbladder lesions. 展开更多
关键词 Gallbladder carcinoma Computed tomography Deep learning Radiomics
下载PDF
Gates joint locally connected network for accurate and robust reconstruction in optical molecular tomography
17
作者 Minghua Zhao Yahui Xiao +2 位作者 Jiaqi Zhang Xin Cao Lin Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期11-22,共12页
Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information ... Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information regarding tumor distribution in living animals.The construction of optical transmission models and the application of reconstruction algorithms in traditional model-based reconstruction processes have affected the reconstruction results,resulting in problems such as low accuracy,poor robustness,and long-time consumption.Here,a gates joint locally connected network(GLCN)method is proposed by establishing the mapping relationship between the inside source distribution and the photon density on surface directly,thus avoiding the extra time consumption caused by iteration and the reconstruction errors caused by model inaccuracy.Moreover,gates module was composed of the concatenation and multiplication operators of three different gates.It was embedded into the network aiming at remembering input surface photon density over a period and allowing the network to capture neurons connected to the true source selectively by controlling three different gates.To evaluate the performance of the proposed method,numerical simulations were conducted,whose results demonstrated good performance in terms of reconstruction positioning accuracy and robustness. 展开更多
关键词 Optical molecular tomography gates module positioning accuracy ROBUSTNESS
下载PDF
Distal-scanning common path probe for optical coherence tomography
18
作者 Zhengyu Chen Bin He +8 位作者 Zichen Yin Zhangwei Hu Yejiong Shi Chengming Wang Xiao Zhang Ning Zhang Linkai Jing Guihuai Wang Ping Xue 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期84-92,共9页
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be... In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus. 展开更多
关键词 Common path optical coherence tomography endoscopic probe
下载PDF
Contribution of Computed Tomography to the Diagnosis of Urinary Lithiasis in a West African University Hospital
19
作者 Some Milckisédek Judicaël Marouruana Tankoano Aïda Ida +5 位作者 Ouedraogo Pakisba Ali Tonde Kouka François Dassis Kindo Bassirou Zanga Soré Moussa Ouedraogo Nina-Astrid Bamouni Yomboé Abel 《Open Journal of Radiology》 2024年第2期25-32,共8页
Introduction: Urinary lithiasis is defining as a condition characterized by the formation of concretions in the kidneys or urinary excretory tract. We aimed to study professional practice in CT urinary lithiasis at CH... Introduction: Urinary lithiasis is defining as a condition characterized by the formation of concretions in the kidneys or urinary excretory tract. We aimed to study professional practice in CT urinary lithiasis at CHUYO. Materials and method: This was a descriptive cross-sectional study with retrospective data collection covering 3 years from January 2017 to December 2019. Results: In general, it was noted that CT scans in our environment provide all the elements needed by urologists to diagnose urinary lithiasis and its impact on the urinary system. However, there are shortcomings, particularly in terms of the accuracy of the shape and density of the stones in the CT scan reports, which does not make it easier for urologists to decide on treatment. Conclusion: Computed tomography plays a major role in the diagnosis and therapeutic management of urinary lithiasis, and its use needs to be improved in our context. 展开更多
关键词 Computed tomography Urinary Lithiasis DIAGNOSIS CHUYO
下载PDF
The risk of prostate cancer on incidental finding of an avid prostate uptake on 2-deoxy-2-[^(18)F]fluoro-D-glucose positron emission tomography/computed tomography for non-prostate cancer-related pathology:A single centre retrospective study
20
作者 Anthony Franklin Troy Gianduzzo +7 位作者 Boon Kua David Wong Louise McEwan James Walters Rachel Esler Matthew J.Roberts Geoff Coughlina John W.Yaxley 《Asian Journal of Urology》 CSCD 2024年第1期33-41,共9页
Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)... Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)ordered at Department of Urology,The Wesley Hospital,Brisbane,QLD,Australia for non-PCa related pathology.Methods:Retrospective analysis of consecutive men between August 2014 and August 2019 presenting to a single institution for 18F-FDG PET/CT for non-prostate related conditions was conducted.Men were classified as benign,indeterminate,or malignant depending of the results of prostate-specific antigen(PSA),PSA velocity,biopsy histopathology,and three-Tesla(3 T)multiparametric MRI(mpMRI)Prostate Imaging Reporting and Data System score,or gallium-68-prostate-specific membrane antigen(68Ga-PSMA)PET/CT results.Results:Three percent(273/9122)of men demonstrated 18F-FDG avidity within the prostate.Eighty-five percent(231/273)were further investigated,including with PSA tests(227/231,98.3%),3 T mpMRI(68/231,29.4%),68Ga-PSMA PET/CT(33/231,14.3%),and prostate biopsy(57/231,24.7%).Results were considered benign in 130/231(56.3%),indeterminate in 31/231(13.4%),and malignant in 70/231(30.3%).PCa was identified in 51/57(89.5%)of the men who proceeded to biopsy,including 26/27(96.3%)men with Prostate Imaging Reporting and Data System scores 4-5 mpMRI and six men with a positive 68Ga-PSMA PET/CT.The most common Gleason score on biopsy was greater than or equal to 4+5(14/51,27.5%).68Ga-PSMA PET/CT was concordant with the 18F-FDG findings in 26/33(78.8%).All 13 men with a positive concordant 18F-FDG,3 T mpMRI,and 68Ga-PSMA PET/CT had PCa on biopsy.There was no statistically significant difference in the 18F-FDG maximum standardized uptake value between the benign or malignant groups(5.7 vs.6.1;p=0.580).Conclusion:In this study,after an incidental finding of an avid intraprostatic lesion on 18F-FDG PET/CT,70 of the 231 cases(30.3%;0.8%of the entire cohort)had results consistent with PCa,most commonly as Gleason score greater than or equal to 4+5 disease.Unless there is limited life expectancy due to competing medical co-morbidity,men with an incidental finding of intraprostatic uptake on 18F-FDG should be further investigated using principles of PCa detection. 展开更多
关键词 Prostatecancer Positionemission tomography Multiparametric magneticresonance imaging Prostatebiopsy
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部