期刊文献+
共找到7,139篇文章
< 1 2 250 >
每页显示 20 50 100
Construction and realization of the knowledge base and inference engine of an IDSS model for air-conditioning cooling/heating sources selection
1
作者 刘颖 王如竹 +1 位作者 李云飞 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2003年第2期136-141,共6页
The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowle... The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building. 展开更多
关键词 air-conditioning cooling/heating sources intelligent decision support system knowledge base inference engine
下载PDF
Decoupled thermal–hydraulic analysis of an air-cooled separated heat pipe for spent fuel pools under natural convection 被引量:1
2
作者 Hui-Lin Xue Jian-Jie Cheng +3 位作者 Wei-Hao Ji Wen-Jin Li Han-Zhong Tao Wei Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第6期183-197,共15页
An investigation of the decoupled thermal–hydraulic analysis of a separated heat pipe spent fuel pool passive cooling system(SFS)is essential for practical engineering applications.Based on the principles of thermal ... An investigation of the decoupled thermal–hydraulic analysis of a separated heat pipe spent fuel pool passive cooling system(SFS)is essential for practical engineering applications.Based on the principles of thermal and mass balance,this study decoupled the heat transfer processes in the SFS.In accordance with the decoupling conditions,we modeled the spent fuel pool of the CAP1400 pressurized water reactor in Weihai and used computational fluid dynamics to explore the heat dissipation capacity of the SFS under different air temperatures and wind speeds.The results show that the air-cooled separated heat pipe radiator achieved optimal performance at an air temperature of 10℃ or wind speed of 8 m/s.Fitted equations for the equivalent thermal conductivity of the separated heat pipes with the wind speed and air temperature we obtained according to the thermal resistance network model.This study is instructive for the actual operation of an SFS. 展开更多
关键词 Decoupled analysis Separated heat pipe CAP1400 Finned tube radiator Passive cooling
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
3
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditioning refrigerating MACHINE condense heat ENTROPY evaluation LS-SVM
下载PDF
Effect of the Arrangement of a New-Type of Turbulator Inserts on Heat Pipe Exchanger Performances
4
作者 Ibtisam A.Hasan Wafa Maki 《Fluid Dynamics & Materials Processing》 EI 2023年第10期2749-2759,共11页
This research tests the effect of introducing turbulators of a new type into a circular tube heat exchanger under a constant and uniform longitudinal heatflux condition.A 45 mm diameter copper tube with a length of 1,3... This research tests the effect of introducing turbulators of a new type into a circular tube heat exchanger under a constant and uniform longitudinal heatflux condition.A 45 mm diameter copper tube with a length of 1,350 mm is utilized with a solid disk being inserted inside the tube,which consists of three sections,each one containing two slots.The slot is cut at a 45 degree angle toward the inner tube surface,which results in diverging theflow toward the inner hot tube surface in order to enhance the heat transfer process.Air is considered as the workingfluid with Prandtl number 0.71.The Reynolds number spans the interval from 6,000–13,500,which indicates that the consideredflow is turbulent.The heat exchanger performance is studied and analyzed in terms of average Nusselt number.The experimental results show that the Nusselt number value is directly proportional to the increase of the Reynolds number,and the number of turbulators inserts.With the use of three novel turbulators,the heat transfer was about 3.15 times higher than that in the smooth tube and the friction factor was about 1.11. 展开更多
关键词 heat pipe exchanger heat transfer inserts(NT inserts) turbulators(novel turbulators) disk(solid disk)
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
5
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2023年第8期61-85,共17页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned heat pipe heat Exchanger Thermal Efficiency Thermal Effectiveness Air Conditioning Freon R404A
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
6
作者 Élcio Nogueira 《Journal of Modern Physics》 2023年第8期61-85,共6页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned heat pipe heat Exchanger Thermal Efficiency Thermal Effectiveness Air Conditioning Freon R404A
下载PDF
Design and fabrication of sintered wick for miniature cylindrical heat pipe 被引量:4
7
作者 蒋乐伦 汤勇 +4 位作者 周伟 蒋琳珍 肖潭 李燕 高金武 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第1期292-301,共10页
Miniature cylindrical metal powder sintered wick heat pipe (sintered heat pipe) is an ideal component with super-high thermal efficiency for high heat flux electronics cooling. The sintering process for sintered wic... Miniature cylindrical metal powder sintered wick heat pipe (sintered heat pipe) is an ideal component with super-high thermal efficiency for high heat flux electronics cooling. The sintering process for sintered wick is important for its quality. The sintering process was optimally designed based on the equation of the heat transfer limit of sintered heat pipe. Four-step sintering process was proposed to fabricate sintered wick. The sintering parameters including sintering temperature, sintering time, sintering atmosphere and sintering position were discussed. The experimental results showed that the proper sintering temperature was 950 ℃ for Cu powder of 159μm and 900 ℃ for Cu powders of 81 and 38 μm, respectively, while the wick thickness was 0.45 mm and sintering time was 3 h. The optimized sintering time was 3 h for 0.45 and 0.6 mm wick thickness and 1 h for 0.75 mm wick thickness, respectively, when copper powder diameter was 159μm and sintering temperature was 950 ℃. Redox reduction reaction between H2 and CuO during sintering could produce segmentation cracks in Cu powders as a second structure. Sintering at vertical position can effectively avoid the generation of gap between wick and the inner wall of pipe. 展开更多
关键词 heat pipe WICK SINTERING POROSITY SHRINKAGE
下载PDF
Fabrication of flatten grooved-sintered wick heat pipe 被引量:1
8
作者 蒋乐伦 汤勇 +2 位作者 周伟 蒋琳珍 陆龙生 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2013年第9期2714-2725,共12页
With the rapid rising of heat flux and reduction of heat dissipating space of microelectronic devises, flattened sintered heat pipe has become an ideal conducting element of use in the electronic cooling field. A manu... With the rapid rising of heat flux and reduction of heat dissipating space of microelectronic devises, flattened sintered heat pipe has become an ideal conducting element of use in the electronic cooling field. A manufacturing technology named phase change flattening process is presented to fabricate the flattened grooved-sintered wick heat pipe (GSHP for short). Deformation geometry of flattened GSHP and the elasto-plastic deformation of flattening process are analyzed theoretically and verified by experiments. The results show that the vapor pressure inside sintered heat pipe during flattening process is determined by the saturated vapor pressure equation; the width and vapor area of flattened heat pipe change greatly as the flattening proceeds; the maximum equivalent strain distributes at the interface between wick and vapor in the fiat section; the buckling phenomenon can be well eliminated when the flattening temperature reaches 480 K; phase change flattening punch load increases with flattening temperature and displacement. 展开更多
关键词 heat pipe WICK FLATTENING elasto-plastic deformation BUCKLING vapor pressure
下载PDF
Improving the performance of a thermoelectric power system using a flat-plate heat pipe 被引量:8
9
作者 Suchen Wu Yiwen Ding +1 位作者 Chengbin Zhang Dehao Xu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期44-53,共10页
A gravitational flat-plate heat pipe is designed and fabricated in this paper to serve as a heat spreader to diffuse the local heat source to the hot side of the thermoelectric power module.Based on this, an experimen... A gravitational flat-plate heat pipe is designed and fabricated in this paper to serve as a heat spreader to diffuse the local heat source to the hot side of the thermoelectric power module.Based on this, an experimental test for the thermoelectric power generation system is conducted to study the influences of the heat spreader on the temperature uniformity and power generation performance when exposing to a local heat source.In addition,the effects of the heating power, inclination angle, and local heat source size on the power generation performance of the thermoelectric power module using a flat-plate heat pipe as a heat spreader are examined and compared with that using a metal plate.The results indicate that the gravitational flat-plate heat pipe has considerable advantages over the metal plate in the temperature uniformity.The superiority of temperature uniformity in the improvement of power generation performance for the thermoelectric power system using a heat pipe is demonstrated.Particularly, the heat pipe shows good adaptability to placement mode and the local heat source size, which is beneficial to the application in the thermoelectric power generation. 展开更多
关键词 THERMOELECTRIC heat pipe heat SPREADER Power generation
下载PDF
Analysis of Collapse in Flattening a Micro-grooved Heat Pipe by Lateral Compression 被引量:5
10
作者 LI Yong HE Ting ZENG Zhixin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2012年第6期1210-1217,共8页
The collapse of thin-walled micro-grooved heat pipes is a common phenomenon in the tube flattening process, which seriously influences the heat transfer performance and appearance of heat pipe. At present, there is no... The collapse of thin-walled micro-grooved heat pipes is a common phenomenon in the tube flattening process, which seriously influences the heat transfer performance and appearance of heat pipe. At present, there is no other better method to solve this problem. A new method by heating the heat pipe is proposed to eliminate the collapse during the flattening process. The effectiveness of the proposed method is investigated through a theoretical model, a finite element(FE) analysis, and experimental method. Firstly, A theoretical model based on a deformation model of six plastic hinges and the Antoine equation of the working fluid is established to analyze the collapse of thin walls at different temperatures. Then, the FE simulation and experiments of flattening process at different temperatures are carried out and compared with theoretical model. Finally, the FE model is followed to study the loads of the plates at different temperatures and heights of flattened heat pipes. The results of the theoretical model conform to those of the FE simulation and experiments in the flattened zone. The collapse occurs at room temperature. As the temperature increases, the collapse decreases and finally disappears at approximately 130 ℃ for various heights of flattened heat pipes. The loads of the moving plate increase as the temperature increases. Thus, the reasonable temperature for eliminating the collapse and reducing the load is approximately 130℃. The advantage of the proposed method is that the collapse is reduced or eliminated by means of the thermal deformation characteristic of heat pipe itself instead of by external support. As a result, the heat transfer efficiency of heat pipe is raised. 展开更多
关键词 tube flattening COLLAPSE micro-grooved heat pipe heatING lateral compression FE simulation
下载PDF
Analysis of Heat Transfer Performance of Oscillating Heat Pipes Based on a Central Composite Design 被引量:12
11
作者 马永锡 张红 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2006年第2期223-228,共6页
Oscillating heat pipes (OHPs) are very promising cooling devices. Their heat transfer performance is af- fected by many factors, and the form of the relationship between the performance and the factors is complex and ... Oscillating heat pipes (OHPs) are very promising cooling devices. Their heat transfer performance is af- fected by many factors, and the form of the relationship between the performance and the factors is complex and non-linear. In this paper, the effects of charging ratio, inclination angle, and heat input and their interaction effects on heat transfer performance of a looped copper-water OHP are analyzed. First, suppose that the relationship between the response and the variables approximates a second-order model. And use the central composite design to arrange the ex- periment. Then, the method of least squares is used to estimate the parameters in the second-order model. Finally, multi- variate variance analysis is used to analyze the model. The results show that the assumption is right, that is to say, the re- lationship is well modeled by a second-order function. Among the three main effect variables, the effect of inclination angle is the most significant, but their interaction effects are not significant. In the range of the considered factors, both the optimum charging ratio and the optimum inclination angle increase as the heating water flow rate increases. 展开更多
关键词 oscillating heat pipe heat transfer central composite experimental design variance analysis
下载PDF
FEM Simulation of Large Diameter Pipe Bending Using Local Heating 被引量:5
12
作者 LI Xue-tong WANG Min-ting DU Feng-shan XU Zhi-qiang 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2006年第5期25-29,共5页
With the aid of elastic plastic large deformation finite element method (FEM), an elastic plastic and cou pling thermo-mechanical model was built to calculate the bending process of the bent pipe, combining with loc... With the aid of elastic plastic large deformation finite element method (FEM), an elastic plastic and cou pling thermo-mechanical model was built to calculate the bending process of the bent pipe, combining with local heating or cooling of the bent pipe. Based on the FEM simulation, the metal deformation during the bending process was analyzed in detail. The thinning and thickening ratio of the pipe wall thickness, the ovality of the cross section of the pipe and the spring back angle, etc. , are presented. 展开更多
关键词 bent pipe finite element method local heating simulation
下载PDF
Function chain neural network prediction on heat transfer performance of oscillating heat pipe based on grey relational analysis 被引量:12
13
作者 鄂加强 李玉强 龚金科 《Journal of Central South University》 SCIE EI CAS 2011年第5期1733-1737,共5页
As for the factors affecting the heat transfer performance of complex and nonlinear oscillating heat pipe (OHP),grey relational analysis (GRA) was used to deal with the relationship between heat transfer rate of a loo... As for the factors affecting the heat transfer performance of complex and nonlinear oscillating heat pipe (OHP),grey relational analysis (GRA) was used to deal with the relationship between heat transfer rate of a looped copper-water OHP and charging ratio,inner diameter,inclination angel,heat input,number of turns,and the main influencing factors were defined.Then,forecasting model was obtained by using main influencing factors (such as charging ratio,interior diameter,and inclination angel) as the inputs of function chain neural network.The results show that the relative average error between the predicted and actual value is 4%,which illustrates that the function chain neural network can be applied to predict the performance of OHP accurately. 展开更多
关键词 oscillating heat pipe grey relational analysis fimction chain neural network heat transfer
下载PDF
Thermal analysis of an LED module with a novelly assembled heat pipe heat sink 被引量:3
14
作者 TANG Yong CHEN Qiu +3 位作者 GUAN Wo-huan LI Zong-tao YU Bin-hai YUAN Wei 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第4期921-928,共8页
This work aims to improve the thermal performance of a light emitting diode(LED) module by employing a novelly assembled heat pipe heat sink. The heat pipe was embedded into the heat sink by a phase change expansion a... This work aims to improve the thermal performance of a light emitting diode(LED) module by employing a novelly assembled heat pipe heat sink. The heat pipe was embedded into the heat sink by a phase change expansion assembly(PCEA) process, which was developed by both finite element(FE) analysis and experiments. Heat transfer performance and optical performance of the LED modules were experimentally investigated and discussed. Compared to the LED module with a traditionally assembled heat pipe heat sink, the LED module employing the PCEA process exhibits about 20% decrease in the thermal resistance from the MCPCB to the heat pipe. The junction temperature is 4% lower and the luminous flux is 2% higher. The improvement in the thermal and optical performance is important to the high power LED applications. 展开更多
关键词 light EMITTING DIODE (LED) phase change assembly heat pipe heat SINK thermal analysis
下载PDF
Preparation of heat-resistant aluminum alloy pipe blanks by multi-layer spray deposition 被引量:4
15
作者 袁武华 陈振华 黄培云 《中国有色金属学会会刊:英文版》 EI CSCD 2000年第4期460-464,共5页
A heat resistant aluminum alloy pipe blank with dimensions of d 700/300 mm×1 200 mm was prepared by the multi layer spray deposition technology. Optical microscopy, X ray diffractometry and transmission electron ... A heat resistant aluminum alloy pipe blank with dimensions of d 700/300 mm×1 200 mm was prepared by the multi layer spray deposition technology. Optical microscopy, X ray diffractometry and transmission electron microscopy were used to analyze its morphologies and microstructures. The results show that the microstructures of the pipe blank are homogeneous and the precipitates are uniformly distributed d 25~70 nm spherical or sphere like Al 12 (Fe,V) 3Si particles, its mechanical properties at room temperature and 350 ℃ after densification by extrusion are σ b=412 MPa, δ =7.6% and σ b=187 MPa, δ =7.6%, respectively. The analyses indicate that the proper match of the motion rates of atomizer and substrate can produce deposited blanks with uniform thickness and relatively high cooling rate. 展开更多
关键词 heat RESISTANT aluminum alloy pipe BLANKS SPRAY DEPOSITION rapid SOLIDIFICATION
下载PDF
Application of high temperature heat pipe in hypersonic vehicles thermal protection 被引量:9
16
作者 白穜 张红 许辉 《Journal of Central South University》 SCIE EI CAS 2011年第4期1278-1284,共7页
In order to develop further the application of high temperature heat pipe in hypersonic vehicles thermal protection, the principles and characteristics of high temperature heat pipe used in hypersonic vehicles thermal... In order to develop further the application of high temperature heat pipe in hypersonic vehicles thermal protection, the principles and characteristics of high temperature heat pipe used in hypersonic vehicles thermal protection were introduced. The methods of numerical simulation, theory analysis and experiment research were utilized to analyze the frozen start-up and steady state characteristic of the heat pipe as well as the machining improvement for fabricating irregularly shaped heat pipe which is suitable for leading edge of hypersonic vehicles. The results indicate that the frozen start-up time of heat pipe is long (10 min) and there exists large temperature difference along the heat pipe (47 ℃/cm), but the heat pipe can reduce the temperature in stagnation area of hypersonic vehicles from 1 926 to 982 ℃ and work normally during 1 000-1 200℃. How to improve the maximum heat transfer capability and reduce the time needed for start-up from frozen state of the heat pipe by optimizing thermostructure such as designing of a novel wick with high performance is the key point in hypersonic vehicles thermal protection of heat pipe. 展开更多
关键词 thermal protection high temperature heat pipe heat transfer limit start-up time
下载PDF
Thermal Characteristics of Heat Pipe with Axially Swallow-tailed Microgrooves 被引量:6
17
作者 陈永平 朱旺法 +1 位作者 张程宾 施明恒 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第2期185-193,共9页
A thermal model for a heat pipe with axially swallow-tailed microgrooves is developed and analyzed numerically to predict the heat transfer capacity and total thermal resistance.The effect of heat load on the axial di... A thermal model for a heat pipe with axially swallow-tailed microgrooves is developed and analyzed numerically to predict the heat transfer capacity and total thermal resistance.The effect of heat load on the axial distribution of capillary radius,and the effect of working temperature and wick structure on the maximum heat transfer capability,as well as the effect of the heat load and working temperature on the total thermal resistance are all investigated and discussed.It is indicated that the meniscus radius increases non-linearly and slowly at the evaporator and adiabatic section along the axial direction,while increasing drastically at the beginning of the condenser section.The pressure difference in the vapor phase along the axial direction is much smaller than that in the liquid phase.In addition,the heat transfer capacity is deeply affected by the working temperature and the size of the wick.A groove wick structure with a wider groove base width and higher groove depth can enhance the heat transfer capability.The effect of the working temperature on the total thermal resistance is insignificant;however,the total thermal resistance shows dependence upon the heat load.In addition,the accuracy of the model is also verified by the experiment in this paper. 展开更多
关键词 grooved heat pipe heat transfer capacity total thermal resistance CAPILLARY
下载PDF
A review on application of nanofluid in various types of heat pipes 被引量:7
18
作者 Mohammad Alhuyi NAZARI Mohammad H. AHMADI +2 位作者 Milad SADEGHZADEH Mohammad Behshad SHAFII Marjan GOODARZI 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第5期1021-1041,共21页
Nanotechnology is widely used in heat transfer devices to improve thermal performance.Nanofluids can be applied in heat pipes to decrease thermal resistance and achieve a higher heat transfer capability.In the present... Nanotechnology is widely used in heat transfer devices to improve thermal performance.Nanofluids can be applied in heat pipes to decrease thermal resistance and achieve a higher heat transfer capability.In the present article,a comprehensive literature review is performed on the nanofluids’ applications in heat pipes.Based on reviewed studies,nanofluids have a high capacity to boost the thermal behavior of various types of heat pipes such as conventional heat pipes,pulsating heat pipes,and thermosyphons.Besides,it is observed that there must be a selected amount of concentration for the high-performance utilization of nanoparticles;high concentration of nanoparticles causes a higher thermal resistance which is mainly attributed to increment in the dynamic viscosity and the higher possibility of particles’ agglomeration.Enhancement in heat transfer performance is the result of increasing in nucleation sites and the intrinsically greater nanofluids’ thermal conductivity. 展开更多
关键词 heat pipe NANOFLUID thermal resistance thermal performance
下载PDF
Numerical Simulation and Optimization of a Mid-Temperature Heat Pipe Exchanger 被引量:7
19
作者 Jun Du Xin Wu +1 位作者 Ruonan Li Ranran Cheng 《Fluid Dynamics & Materials Processing》 EI 2019年第1期77-87,共11页
In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.... In this paper,we take the mid-temperature gravity heat pipe exchanger as the research object,simulate the fluid flow field,temperature field and the working state of heat pipe in the heat exchanger by Fluent software.The effects of different operating parameters and fin parameters on the heat transfer performance of heat exchangers are studied.The results show that the heat transfer performance of the mid-temperature gravity heat pipe exchanger is the best when the fin spacing is between 5 mm and 6 mm,the height of the heat pipe is between 12 mm and 13 mm,and the inlet velocity of the fluid is between 2.5 m/s to 3 m/s. 展开更多
关键词 Gravity heat pipe heat exchanger FLUENT numerical simulation heat transfer performance
下载PDF
Effects of bending on heat transfer performance of axial micro-grooved heat pipe 被引量:5
20
作者 蒋乐伦 汤勇 潘敏强 《Journal of Central South University》 SCIE EI CAS 2011年第2期580-586,共7页
Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux,which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved... Heat pipe is always bent in the typical application of electronic heat dissipation at high heat flux,which greatly affects its heat transfer performance. The capillary limit of heat transport in the bent micro-grooved heat pipes was analyzed in the vapor pressure drop,the liquid pressure drop and the interaction of the vapor with wick fluid. The bent heat pipes were fabricated and tested from the bending angle,the bending position and the bending radius. The results show that temperature difference and thermal resistance increase while the heat transfer capacity of the heat pipe decreases,with the increase of the bending angles and the bending position closer to the vapor section. However,the effects of bending radius can be ignored. The result agrees well with the predicted equations. 展开更多
关键词 electronics cooling system axial micro-grooved heat pipe BENDING heat transfer performance
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部