Hallux valgus is a relatively common and multifaceted complex deformity of the front part of the foot. It is the result of multiple effects of innate (endogenous) and exogenous etiological factors with different degre...Hallux valgus is a relatively common and multifaceted complex deformity of the front part of the foot. It is the result of multiple effects of innate (endogenous) and exogenous etiological factors with different degrees of influence. The degree of hallux valgus deformity is usually assessed by radiological values of hallux valgus (HV) and intermetatarsal (IM) angles. The aim of the paper is to justify the definition of hallux valgus deformity as a function of one angle, (HVA or IMA), and then to determine the functional connection and the most suitable function equalizing the values of the angles IMA and HVA. As hallux valgus is a double angulation deformity, the analytically determined connection between the HVA and IMA angles reduces the study of the deformity to the study of function with one argument, and makes the analysis of deformity changes before and after operative treatment simpler. For the determined connections between the angles, the values of linear proportionality coefficients and regression coefficients of corresponding linear functions of analytical equalization of the value of the IM angle and the degree of deformity for a given value of the HV angle were experimentally determined. The obtained results were checked on a sample of 396 operatively treated hallux valgus deformities. The presented analytical approach and the obtained functional links of IMA and HVA enable quantitative observation of the change in the degree of deformity based on the radiologically determined value of these angles, and the established nonlinear function will be useful for evaluating the expected value of the IM angle and the degree of deformity based only on the measured value of the HV angle. .展开更多
A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel...A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection.展开更多
文摘Hallux valgus is a relatively common and multifaceted complex deformity of the front part of the foot. It is the result of multiple effects of innate (endogenous) and exogenous etiological factors with different degrees of influence. The degree of hallux valgus deformity is usually assessed by radiological values of hallux valgus (HV) and intermetatarsal (IM) angles. The aim of the paper is to justify the definition of hallux valgus deformity as a function of one angle, (HVA or IMA), and then to determine the functional connection and the most suitable function equalizing the values of the angles IMA and HVA. As hallux valgus is a double angulation deformity, the analytically determined connection between the HVA and IMA angles reduces the study of the deformity to the study of function with one argument, and makes the analysis of deformity changes before and after operative treatment simpler. For the determined connections between the angles, the values of linear proportionality coefficients and regression coefficients of corresponding linear functions of analytical equalization of the value of the IM angle and the degree of deformity for a given value of the HV angle were experimentally determined. The obtained results were checked on a sample of 396 operatively treated hallux valgus deformities. The presented analytical approach and the obtained functional links of IMA and HVA enable quantitative observation of the change in the degree of deformity based on the radiologically determined value of these angles, and the established nonlinear function will be useful for evaluating the expected value of the IM angle and the degree of deformity based only on the measured value of the HV angle. .
基金National Natural Science Foundation of China under Nos.50808107,51178250 and 51261120377
文摘A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection.