Simulation approach includes such processes as photon emissions from X-ray tube with a spectral distribution, total reflection on the sample support, photoelectric effect in thin layer sample, as well as characteristi...Simulation approach includes such processes as photon emissions from X-ray tube with a spectral distribution, total reflection on the sample support, photoelectric effect in thin layer sample, as well as characteristic line absorption and detection. The calculation results are in agreement with experimental ones.展开更多
The present study aims to monitor and assess the water quality of the Bezerra River located in the Western Brazilian Parana state. For the monitoring of river waters, six samplings were established per month during on...The present study aims to monitor and assess the water quality of the Bezerra River located in the Western Brazilian Parana state. For the monitoring of river waters, six samplings were established per month during one year. As indicators of the water quality, physico-chemical parameters such as water temperature, pH, turbidity, dissolved oxygen and COD (chemical oxygen demand) were chosen, as well as trace and majority element concentrations. It is noteworthy that the mean annual values of conductivity, turbidity and COD have progressively increased along the river with maximum values after the Cascavel western sewage treatment plant. Only 13 elements were found in the six collection points, but the metallic elements Cr, Mn, Fe, Cu and Zn have shown concentrations above the maximum limits recommended by Brazilian environmental legislation, suggesting the presence of highly polluting anthropogenic sources. Correlation analyses were used to determine the spatio-variability of water quality variables. The six collection sites were grouped into two clusters, with the element composition in the first cluster (sites 1, 2 and 6) being due to strong anthropogenic activities. The study of the Bezerra River water quality could help to develop municipal environmental policies and help with the management of water conservation in the Bezerra River basin.展开更多
The study of the mineral and organic content of the Allende meteorite is important for our understanding of the molecular evolution of the universe as well as the ancient Earth. Previous studies have characterized the...The study of the mineral and organic content of the Allende meteorite is important for our understanding of the molecular evolution of the universe as well as the ancient Earth. Previous studies have characterized the magnetic minerals present in ordinary and carbonaceous chondrites, providing information on the evolution of magnetic fields. The interaction of organic compounds with magnetic minerals is a possible source of chemical diversity, which is crucial for molecular evolution. Carbon compounds in meteorites are of great scientific interest for a variety of reasons, such as their relevance to the origins of chirality in living organisms. This study presents the characterization of organic and mineral compounds in the Allende meteorite. The structural and physicochemical characterization of the Allende meteorite was accomplished through light microscopy, powder X-ray diffraction with complementary Rietveld refinement, Raman and infrared spectroscopy, mass spectrometry, scanning electron microscopy, and atomic force microscopy using magnetic signal methods to determine the complex structure and the interaction of organic compounds with magnetic Ni-Fe minerals. The presence of Liesegang-like patterns of chondrules in fragments of the Allende structure may also be relevant to understanding how the meteorite was formed. Other observations include the presence of magnetic materials and nanorod-like solids with relatively similar sizes as well as the heterogeneous distribution of carbon in chondrules. Signals observed in the Raman and infrared spectra resemble organic compounds such as carbon nanotubes and peptide-like molecules that have been previously reported in other meteorites, making the Mexican Allende meteorite a feasible sample for the study of the early Earth and exoplanetary bodies.展开更多
Raman spectroscopy is a common method of studying carbon-based materials such as multi-walled carbon nanotubes (MWCNT). However, the analysis of this technique is non-trivial since recorded spectra may be a convolutio...Raman spectroscopy is a common method of studying carbon-based materials such as multi-walled carbon nanotubes (MWCNT). However, the analysis of this technique is non-trivial since recorded spectra may be a convolution of both molecular vibrations and phonon resonances. The energies of these physical processes may occur in the same energy regime, and hence several analytical approaches can be necessary for a full analysis. Due to the negligible quantities of non-graphitic carbon in MWCNT, the present fitting procedure focuses on understanding phonon resonances to elucidate how varying modifications of MWCNT ultimately influence their graphitic bulk structure. We have found this approach to provide greater insight into the structure of MWCNT when low quantities of amorphous carbon are present, when compared with methods which try to interpret both phonon scattering and molecular vibrations simultaneously. Different pre-treatments for the modification of the graphitic structure of MWCNT are compared, including aqueous acidic and gas phase methods, and statistically evaluated. Focusing on phonon resonances enables one to analyze the reaction process of nitrosulfuric acid pre-treatment at different temperatures. Thereby, it is possible to control the ratio between defects and graphitic structures in MWCNT samples and prepare samples with reproducible D/G ratios.展开更多
Over the past few decades,the metal elements(MEs)in atmospheric particles have aroused great attention.Some well-established techniques have been used to measure particlebound MEs.However,each method has its own advan...Over the past few decades,the metal elements(MEs)in atmospheric particles have aroused great attention.Some well-established techniques have been used to measure particlebound MEs.However,each method has its own advantages and disadvantages in terms of complexity,accuracy,and specific elements of interest.In this study,the performances of inductively coupled plasma-optical emission spectrometry(ICP-OES)and total reflection X-ray fluorescence spectroscopy(TXRF)were evaluated for quality control to analyze data accuracy and precision.The statistic methods(Deming regression and significance testing)were applied for intercomparison between ICP-OES and TXRF measurements for same lowloading PM_(2.5)samples in Weizhou Island.The results from the replicate analysis of standard filters(SRM 2783)and field filters samples indicated that 10 MEs(K,Ca,V,Cr,Mn,Fe,Ni,Cu,Zn,and Pb)showed good accuracies and precision for both techniques.The higher accuracy tended to the higher precision in the MEs analysis process.In addition,the interlab comparisons illustrated that V and Mn all had good agreements between ICP-OES and TXRF.The measurements of K,Cu and Zn were more reliable by TXRF analysis for low-loading PM_(2.5).ICP-OES was more accurate for the determinations for Ca,Cr,Ni and Pb,owing to the overlapping spectral lines and low sensitivity during TXRF analysis.The measurements of Fe,influenced by low-loading PM_(2.5),were not able to determine which instrument could obtain more reliable results.These conclusions could provide reference information to choose suitable instrument for the determination of MEs in low-loading PM_(2.5)samples.展开更多
文摘Simulation approach includes such processes as photon emissions from X-ray tube with a spectral distribution, total reflection on the sample support, photoelectric effect in thin layer sample, as well as characteristic line absorption and detection. The calculation results are in agreement with experimental ones.
文摘The present study aims to monitor and assess the water quality of the Bezerra River located in the Western Brazilian Parana state. For the monitoring of river waters, six samplings were established per month during one year. As indicators of the water quality, physico-chemical parameters such as water temperature, pH, turbidity, dissolved oxygen and COD (chemical oxygen demand) were chosen, as well as trace and majority element concentrations. It is noteworthy that the mean annual values of conductivity, turbidity and COD have progressively increased along the river with maximum values after the Cascavel western sewage treatment plant. Only 13 elements were found in the six collection points, but the metallic elements Cr, Mn, Fe, Cu and Zn have shown concentrations above the maximum limits recommended by Brazilian environmental legislation, suggesting the presence of highly polluting anthropogenic sources. Correlation analyses were used to determine the spatio-variability of water quality variables. The six collection sites were grouped into two clusters, with the element composition in the first cluster (sites 1, 2 and 6) being due to strong anthropogenic activities. The study of the Bezerra River water quality could help to develop municipal environmental policies and help with the management of water conservation in the Bezerra River basin.
文摘The study of the mineral and organic content of the Allende meteorite is important for our understanding of the molecular evolution of the universe as well as the ancient Earth. Previous studies have characterized the magnetic minerals present in ordinary and carbonaceous chondrites, providing information on the evolution of magnetic fields. The interaction of organic compounds with magnetic minerals is a possible source of chemical diversity, which is crucial for molecular evolution. Carbon compounds in meteorites are of great scientific interest for a variety of reasons, such as their relevance to the origins of chirality in living organisms. This study presents the characterization of organic and mineral compounds in the Allende meteorite. The structural and physicochemical characterization of the Allende meteorite was accomplished through light microscopy, powder X-ray diffraction with complementary Rietveld refinement, Raman and infrared spectroscopy, mass spectrometry, scanning electron microscopy, and atomic force microscopy using magnetic signal methods to determine the complex structure and the interaction of organic compounds with magnetic Ni-Fe minerals. The presence of Liesegang-like patterns of chondrules in fragments of the Allende structure may also be relevant to understanding how the meteorite was formed. Other observations include the presence of magnetic materials and nanorod-like solids with relatively similar sizes as well as the heterogeneous distribution of carbon in chondrules. Signals observed in the Raman and infrared spectra resemble organic compounds such as carbon nanotubes and peptide-like molecules that have been previously reported in other meteorites, making the Mexican Allende meteorite a feasible sample for the study of the early Earth and exoplanetary bodies.
文摘Raman spectroscopy is a common method of studying carbon-based materials such as multi-walled carbon nanotubes (MWCNT). However, the analysis of this technique is non-trivial since recorded spectra may be a convolution of both molecular vibrations and phonon resonances. The energies of these physical processes may occur in the same energy regime, and hence several analytical approaches can be necessary for a full analysis. Due to the negligible quantities of non-graphitic carbon in MWCNT, the present fitting procedure focuses on understanding phonon resonances to elucidate how varying modifications of MWCNT ultimately influence their graphitic bulk structure. We have found this approach to provide greater insight into the structure of MWCNT when low quantities of amorphous carbon are present, when compared with methods which try to interpret both phonon scattering and molecular vibrations simultaneously. Different pre-treatments for the modification of the graphitic structure of MWCNT are compared, including aqueous acidic and gas phase methods, and statistically evaluated. Focusing on phonon resonances enables one to analyze the reaction process of nitrosulfuric acid pre-treatment at different temperatures. Thereby, it is possible to control the ratio between defects and graphitic structures in MWCNT samples and prepare samples with reproducible D/G ratios.
基金supported by the National Natural Science Foundation of China(No.42075182)the Science and Technology Pre-research Project for Collaborative Prevention and Control on O3 and PM2.5 Compound Pollution(No.DQGG202026)the Three-dimensional Comprehensive Observation Research Program for O3and PM2.5Compound Pollution in Key Areas in Summer 2021(No.DQGG2021101)
文摘Over the past few decades,the metal elements(MEs)in atmospheric particles have aroused great attention.Some well-established techniques have been used to measure particlebound MEs.However,each method has its own advantages and disadvantages in terms of complexity,accuracy,and specific elements of interest.In this study,the performances of inductively coupled plasma-optical emission spectrometry(ICP-OES)and total reflection X-ray fluorescence spectroscopy(TXRF)were evaluated for quality control to analyze data accuracy and precision.The statistic methods(Deming regression and significance testing)were applied for intercomparison between ICP-OES and TXRF measurements for same lowloading PM_(2.5)samples in Weizhou Island.The results from the replicate analysis of standard filters(SRM 2783)and field filters samples indicated that 10 MEs(K,Ca,V,Cr,Mn,Fe,Ni,Cu,Zn,and Pb)showed good accuracies and precision for both techniques.The higher accuracy tended to the higher precision in the MEs analysis process.In addition,the interlab comparisons illustrated that V and Mn all had good agreements between ICP-OES and TXRF.The measurements of K,Cu and Zn were more reliable by TXRF analysis for low-loading PM_(2.5).ICP-OES was more accurate for the determinations for Ca,Cr,Ni and Pb,owing to the overlapping spectral lines and low sensitivity during TXRF analysis.The measurements of Fe,influenced by low-loading PM_(2.5),were not able to determine which instrument could obtain more reliable results.These conclusions could provide reference information to choose suitable instrument for the determination of MEs in low-loading PM_(2.5)samples.