The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi...The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation.展开更多
The tower line system will be in an unsafe status due to uniform or uneven fall of ice coating which is attached to the surface of tower and lines.The fall of ice could be caused by wind action or thermal force.In ord...The tower line system will be in an unsafe status due to uniform or uneven fall of ice coating which is attached to the surface of tower and lines.The fall of ice could be caused by wind action or thermal force.In order to study the dynamic characteristics of the self-failure of the transmission line under the action of dynamicwind load,a finite elementmodel of the two-span transmission tower line system was established.The birth and death element methods are used to simulate the icing and shedding of the line.Tensile failure strength is the shedding criterion for ice coating.The fluctuating wind speed time history of the tower line systemis first simulated,and then the fluctuating wind and the average wind are superimposed to generate the instantaneous wind speed and converted into wind load.The dynamic response of the transmission tower line systemunder iced coupling with different wind speeds and different thicknesses of ice coating was studied.This is the first attempt that the coupling dynamic response of the icing shedding and wind load for the transmission tower-line system is discussed in this paper.In addition,the dynamic characteristics of wind are included.In particular,the limiting mechanical conditions are considered.According to the simulation results,it is found:because of the ice shedding,the stress of the conductor changes obviously in the first 20 seconds,and the ground wire changes sharply in the first two seconds;the icing of the conductor(ground)wire is gradually deicing under the action of wind vibration;the displacement of tower top increases with the increase of wind speed and icing thickness.展开更多
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission...This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system.展开更多
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th...In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.展开更多
为解决35 k V交流输电线路直线塔巡检无人机自适应能力差,导致巡检作业易出错中断的问题,该文设计一种新型无人机巡检自动化控制系统。此系统由MPU9250九自由度惯性传感器、加速度计、磁力计,采集输电线路直线塔无人机巡检状态数据,通...为解决35 k V交流输电线路直线塔巡检无人机自适应能力差,导致巡检作业易出错中断的问题,该文设计一种新型无人机巡检自动化控制系统。此系统由MPU9250九自由度惯性传感器、加速度计、磁力计,采集输电线路直线塔无人机巡检状态数据,通过积分法、三角函数关系、倾斜补偿方法,解算获取直线塔无人机巡检的姿态、速度、位置数据信息;使用基于模糊PID的自动化控制器,计算无人机巡检的姿态、速度、位置偏差与偏差率,自动调整无人机旋翼转速,控制无人机巡检状态,完成35 kV交流输电线路直线塔无人机巡检自动化控制。实验中,此系统使用下,无人机巡检状态与指定轨迹一致,俯仰角、横滚角、航向角偏差值为0°。展开更多
基金This work was supported by the National Natural Science Foundation of China(Nos.62172242,51901152)Industry University Cooperation Education Program of the Ministry of Education(No.2020021680113)Shanxi Scholarship Council of China.
文摘The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation.
基金This work is supported by the National Natural Science Foundation of China(Grant Nos.41972323 and 51991362)Science and Technology Project of the 13th Five-Year Plan of Jilin Provincial Department of Education(Grant No.JJKH20190126KJ)the Science and Technology Developing Plan Project of Jilin Province(Grant No.20200201055JC).
文摘The tower line system will be in an unsafe status due to uniform or uneven fall of ice coating which is attached to the surface of tower and lines.The fall of ice could be caused by wind action or thermal force.In order to study the dynamic characteristics of the self-failure of the transmission line under the action of dynamicwind load,a finite elementmodel of the two-span transmission tower line system was established.The birth and death element methods are used to simulate the icing and shedding of the line.Tensile failure strength is the shedding criterion for ice coating.The fluctuating wind speed time history of the tower line systemis first simulated,and then the fluctuating wind and the average wind are superimposed to generate the instantaneous wind speed and converted into wind load.The dynamic response of the transmission tower line systemunder iced coupling with different wind speeds and different thicknesses of ice coating was studied.This is the first attempt that the coupling dynamic response of the icing shedding and wind load for the transmission tower-line system is discussed in this paper.In addition,the dynamic characteristics of wind are included.In particular,the limiting mechanical conditions are considered.According to the simulation results,it is found:because of the ice shedding,the stress of the conductor changes obviously in the first 20 seconds,and the ground wire changes sharply in the first two seconds;the icing of the conductor(ground)wire is gradually deicing under the action of wind vibration;the displacement of tower top increases with the increase of wind speed and icing thickness.
文摘This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system.
文摘In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.
文摘为解决35 k V交流输电线路直线塔巡检无人机自适应能力差,导致巡检作业易出错中断的问题,该文设计一种新型无人机巡检自动化控制系统。此系统由MPU9250九自由度惯性传感器、加速度计、磁力计,采集输电线路直线塔无人机巡检状态数据,通过积分法、三角函数关系、倾斜补偿方法,解算获取直线塔无人机巡检的姿态、速度、位置数据信息;使用基于模糊PID的自动化控制器,计算无人机巡检的姿态、速度、位置偏差与偏差率,自动调整无人机旋翼转速,控制无人机巡检状态,完成35 kV交流输电线路直线塔无人机巡检自动化控制。实验中,此系统使用下,无人机巡检状态与指定轨迹一致,俯仰角、横滚角、航向角偏差值为0°。