期刊文献+
共找到2,378篇文章
< 1 2 119 >
每页显示 20 50 100
飞思卡尔扩展Tower System开发平台以支持Power Architecture处理器和微控制器
1
《单片机与嵌入式系统应用》 2011年第11期83-83,共1页
飞思卡尔丰导体扩展了其备受欢迎的Tower System模块开发平台,包括了一系列基于Power Architecture技术的高性能解决方案。
关键词 tower POWER 飞思卡尔 开发平台 微控制器 处理器 M模块
下载PDF
Vibration attenuation performance of wind turbine tower using a prestressed tuned mass damper under seismic excitation
2
作者 Lei Zhenbo Liu Gang +1 位作者 Wang Hui Hui Yi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期511-524,共14页
With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cau... With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation. 展开更多
关键词 wind turbine tower prestressed tuned mass damper vibration control seismic excitation numerical simulation
下载PDF
Comparison between seismic analysis of twisting and regular 52-story towers considering soil-structure interaction
3
作者 Mohamed Naguib Abouelsaad Mohammed Shaaban +1 位作者 Salah El Bagalaty Mohamed E.El Madawy 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第3期663-675,共13页
A dynamic analysis of both twisting and regular towers is carried out to determine the results of considering soil-structure interaction(SSI)on high-rise buildings.In addition,the difference between the seismic perfor... A dynamic analysis of both twisting and regular towers is carried out to determine the results of considering soil-structure interaction(SSI)on high-rise buildings.In addition,the difference between the seismic performance of using twisting towers over regular ones is investigated.The twisting tower is a simulation of the Evolution Tower(Moscow).The towers’skeletons consist of RC elements and rest on a reinforced concrete piled-raft foundation.The soil model is considered as multi-layered with the same soil properties as the zone chosen for the analysis(New Mansoura City,Egypt).The only difference between both towers is their shape in elevation.The whole system is modelled and analyzed in a single step as one full 3D model,which is known as the direct approach in SSI.All analyses are carried out using finite-element software(Midas GTS NX).Dynamic output responses due to three records of seismic loads are proposed and presented in some graphs.Based on the results,it is concluded that SSI has a considerable effect on the dynamic response of tall buildings mainly because of the foundation flexibility,as it leads to lengthening the vibration period,increasing the story drift and the base shear for both cases. 展开更多
关键词 soil-structure interaction seismic analysis twisting towers base shear story drift finite element method Midas GTS NX
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
4
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 Transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
Tower Semiconductor Acquisition: Advancing Intel’s Presence in the Global Market
5
作者 CHEN Kangmin 《Management Studies》 2024年第1期33-41,共9页
This paper delves into the economic event surrounding Intel Corporation’s high-profile acquisition of Tower Corporation.It aims to investigate the reasons behind Intel’s decision to acquire Tower,employ the SWOT ana... This paper delves into the economic event surrounding Intel Corporation’s high-profile acquisition of Tower Corporation.It aims to investigate the reasons behind Intel’s decision to acquire Tower,employ the SWOT analysis method to evaluate the event,and examine its impact on relevant stakeholders.The findings indicate that Intel’s acquisition of Tower was driven by objectives such as strengthening business areas,expanding market share,technological innovation and development,and future development strategy.Through the application of SWOT analysis,it becomes evident that the advantages of the acquisition lie in strengthening technical capabilities and expanding business segments,while simultaneously facing challenges such as integration complexities and pressure.The significance of this paper lies in gaining a comprehensive understanding of the strategic motivations and potential impacts associated with corporate acquisitions,thereby providing valuable insights for decision-making processes.The innovation lies in the comprehensive utilization of SWOT analysis to holistically evaluate the acquisition event,enabling a thorough assessment of its various aspects.For government and policymakers,they should strength regulation of corporate takeovers to ensure fair and transparent market competition,provide support and incentives,and strength cooperation to develop common policies and norms.As for enterprises,it is advised that strategic planning and comprehensive consideration should be formulated and carried out when making acquisitions.Also,stakeholders should actively participate in and monitor the process of corporate acquisition discussion and decision-making,and strengthen cooperation to ensure fair competition,maximizing the interests of all parties. 展开更多
关键词 intel corporation tower corporation ACQUISITION strategic motivation potential impacts SWOT analysis COOPERATION
下载PDF
Design Optimization of a Lattice Tower: Structure and Foundations
6
作者 Cossi Télesphore Nounangnonhou Guy Clarence Semassou +1 位作者 Kossoun Alain Tossa Noémie Sintondji 《Open Journal of Applied Sciences》 2024年第2期483-493,共11页
Produced in power plants, electrical energy is transported to places of consumption via the electricity network. At the heart of this network are the supports that allow electricity to be efficiently transported over ... Produced in power plants, electrical energy is transported to places of consumption via the electricity network. At the heart of this network are the supports that allow electricity to be efficiently transported over long distances, guaranteeing the security and supply of energy to the various centers of use. In the construction of a line, supports occupy an important part in terms of safety and construction cost. It is therefore essential to optimize their use to reduce the cost of transmission lines. This work addresses this problem, which focuses on the optimal utilization of X-lattice towers in the construction of overhead power lines. The challenge is to reconcile the search for optimal cost and respect for the design, resistance and service constraints of the structure. To do this, a parameter having a strong correlation with the weight, foundation and construction cost of the X-lattice tower for 161 kV lines is determined as an important cost variable. This parameter is the wheelbase of the towers. The junction point between the structure and the foundations is obtained by measuring the forces at the base of the tower following the lowering of the loads. These efforts make it possible to size foundations which are of the inverted or isolated sole type. The results obtained reveal that from 8 meters in width, the wheelbase gradually changes until the optimum is obtained at 6.29 meters. With this wheelbase, the production cost is optimal. It clearly emerges from this study that the construction of lattice pylons with a wheelbase of approximately 6.29 meters makes it possible to optimize the cost of construction of 161 kV lines in the Republic of Benin. 展开更多
关键词 Lattice tower WHEELBASE COST OPTIMIZATION FOUNDATION
下载PDF
Evaluation of Driver-Induced Human Errors in Smart Construction Tower Crane Operations Based on DEMATEL-ISM-MICMAC
7
作者 Jiahao Wang Wen Si 《Journal of Applied Mathematics and Physics》 2024年第4期1541-1556,共16页
With the advent of Industry 4.0, smart construction sites have seen significant development in China. However, accidents involving digitized tower cranes continue to be a persistent issue. Among the contributing facto... With the advent of Industry 4.0, smart construction sites have seen significant development in China. However, accidents involving digitized tower cranes continue to be a persistent issue. Among the contributing factors, human unsafe behavior stands out as a primary cause for these incidents. This study aims to assess the human reliability of tower crane operations on smart construction sites. To proactively enhance safety measures, the research employs text mining techniques (TF-IDF-Truncated SVD-Complement NB) to identify patterns of human errors among tower crane operators. Building upon the SHEL model, the study categorizes behavioral factors affecting human reliability in the man-machine interface, leading to the establishment of the Performance Shaping Factors (PSFs) system. Furthermore, the research constructs an error impact indicator system for the intelligent construction site tower crane operator interface. Using the DEMATEL method, it analyzes the significance of various factors influencing human errors in tower crane operations. Additionally, the ISM-MICMAC method is applied to unveil the hierarchical relationships and driving-dependent connections among these influencing factors. The findings indicate that personal state, operating procedures, and physical environment directly impact human errors, while personal capability, technological environment, and one fundamental organizational management factor contribute indirectly. . 展开更多
关键词 Text Mining DEMATEL-ISM-MICMAC Performance Shaping Factors Smart Construction tower Crane Operator
下载PDF
Adsorption Properties of Adsorption Tower Filled with Calcium Superphosphate on NH_3 Emitted from Composting System of Animal Wastes 被引量:2
8
作者 吕丹丹 种云霄 +4 位作者 吴启堂 吴根义 贺德春 丘锦荣 许振成 《Agricultural Science & Technology》 CAS 2012年第9期1982-1985,1990,共5页
[Objective] This study aimed to investigate the adsorption properties of the adsorption tower filled with calcium superphosphate on ammonia volatilized with aer- ation. [Method] Adsorption tower filled with calcium su... [Objective] This study aimed to investigate the adsorption properties of the adsorption tower filled with calcium superphosphate on ammonia volatilized with aer- ation. [Method] Adsorption tower filled with calcium superphosphate was adopted as experimental apparatus, which was constructed by poly vinyl chloride (PVC) circular tubes. With hartshorn as the source of ammonia volatilization, the effect of different ratios of height to diameter of the tower filled with equal amount of calcium super-phosphate on ammonia adsorption was investigated. In addition, adsorption tower with height-diameter ratio of 9.9 was selected to adsorb the ammonia emitted from the composting systems of pig manure and chicken manure with optimized and reg- ulated carbon-nitrogen ratio. [Result] Under certain volatilization rate, calcium super- phosphate particles in the adsorption tower could effectively adsorb the ammonia, and the adsorption efficiency was enhanced with the increase of height-diameter ra-tio, which could reach above 90% with height-diameter ratio of more than 1.1; the ammonia emitted from composting systems of pig manure and chicken manure with optimized and regulated carbon-nitrogen ratio could be completely absorbed using adsorption tower with height-diameter ratio of 9.9 filled with calcium superphosphate accounting for about 8% of the weight of composting materials. [Conclusion] Experi- mental results of this study provided reference for the application of adsorption tower filled with calcium superphosphate in the treatment of waste gas emitted from com- posting materials. 展开更多
关键词 Calcium superphosphate COMPOST AMMONIA Adsorption tower
下载PDF
A reversibly used cooling tower with adaptive neuro-fuzzy inference system 被引量:2
9
作者 吴加胜 张国强 +3 位作者 张泉 周晋 郭永辉 沈炜 《Journal of Central South University》 SCIE EI CAS 2012年第3期715-720,共6页
An adaptive neuro-fuzzy inference system(ANFIS) for predicting the performance of a reversibly used cooling tower(RUCT) under cross flow conditions as part of a heat pump system for a heating mode in winter was demons... An adaptive neuro-fuzzy inference system(ANFIS) for predicting the performance of a reversibly used cooling tower(RUCT) under cross flow conditions as part of a heat pump system for a heating mode in winter was demonstrated.Extensive field experimental work was carried out in order to gather enough data for training and prediction.The statistical methods,such as the correlation coefficient,absolute fraction of variance and root mean square error,were given to compare the predicted and actual values for model validation.The simulation results predicted with the ANFIS can be used to simulate the performance of a reversibly used cooling tower quite accurately.Therefore,the ANFIS approach can reliably be used for forecasting the performance of RUCT. 展开更多
关键词 reversibly used cooling tower HEATING adaptive neuro-fuzzy inference system fuzzy modeling approach
下载PDF
Numerical Simulation of Torrential Rainfall and Vortical Hot Towers in a Midlatitude Mesoscale Convective System 被引量:2
10
作者 ZHANG Man Da-Lin ZHANG WANG Ang-Sheng 《Atmospheric and Oceanic Science Letters》 2009年第4期189-193,共5页
A cloud-resolving model simulation of a mesoscale convective system (MCS) producing torrential rainfall is performed with the finest horizontal resolution of 444 m. It is shown that the model reproduces the observed... A cloud-resolving model simulation of a mesoscale convective system (MCS) producing torrential rainfall is performed with the finest horizontal resolution of 444 m. It is shown that the model reproduces the observed MCS, including its rainfall distribution and amounts, as well as the timing and location of leading rainbands and trailing stratiform clouds. Results show that discrete convective hot towers, shown in Vis5D at a scale of 2-5 kin, are triggered by evaporatively driven cold outflows converging with the high-θe air ahead. Then, they move rearward, with respect to the leading rainbands, to form stratiform clouds. These convective towers generate vortical tubes of opposite signs, with more intense cyclonic vorticity occurring in the leading convergence zone. The results appear to have important implications for the improvement of summertime quantitative precipitation forecasts and the understanding of vortical hot towers, as well midlevel mesoscale convective vortices. 展开更多
关键词 torrential rainfall mei-yu front vortical hot towers mesoscale convective systems
下载PDF
Analysis and Prediction of Corrosion Risk in Atmospheric Distillation Tower Overhead System 被引量:2
11
作者 Niu Luna Han Lei +3 位作者 Chen Wenwu Pan Long Zhang Yanling Qu Dingrong 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2021年第1期21-30,共10页
In order to optimize the atmospheric tower overhead low-temperature system,the physical parameters,multiphase composition,aqueous dew point temperature,and ammonium salt crystallization temperature are simulated with ... In order to optimize the atmospheric tower overhead low-temperature system,the physical parameters,multiphase composition,aqueous dew point temperature,and ammonium salt crystallization temperature are simulated with process simulation software.The temperature distribution in overhead heat exchanger is calculated by heat transfer calculation.The special parts with elbows near the inlet and outlet of heat exchanger are studied by fluid field analysis.Results indicate that under current operating conditions,the aqueous dew point temperature and initial crystallization temperature of NH4Cl are 91°C and 128°C,respectively.Ammonium salt appears in the distillation tower and liquid water occurs in heat exchanger tubes,in which the dew point induced corrosion is the most direct factor for heat exchanger corrosion.In the heat exchanger,condensate water appearing in the area 2.7 meters away from the bundle inlet can give rise to corrosion risk under the moist NH4Cl and high concentration of acidic solution circumstance.For the pipes and elbows located near the inlet and the outlet of heat exchanger,the flow field presents an unsymmetrical distribution.High risk areas are mainly concentrated on the external bend of elbows where the liquid water concentration is higher.The coupling of simulation methods established thereby is approved as an effective way to evaluate the corrosion risk in the atmospheric column overhead system and can provide a scientific basis for corrosion control. 展开更多
关键词 atmospheric tower overhead SIMULATION CORROSION ammonium salt crystallization fluid field
下载PDF
Dynamic Characteristics Analysis of Ice-Adhesion Transmission Tower-Line System under Effect of Wind-Induced Ice Shedding 被引量:1
12
作者 Yongping Yu Lihui Chen +1 位作者 JuanjuanWang Guoji Liu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第11期647-670,共24页
The tower line system will be in an unsafe status due to uniform or uneven fall of ice coating which is attached to the surface of tower and lines.The fall of ice could be caused by wind action or thermal force.In ord... The tower line system will be in an unsafe status due to uniform or uneven fall of ice coating which is attached to the surface of tower and lines.The fall of ice could be caused by wind action or thermal force.In order to study the dynamic characteristics of the self-failure of the transmission line under the action of dynamicwind load,a finite elementmodel of the two-span transmission tower line system was established.The birth and death element methods are used to simulate the icing and shedding of the line.Tensile failure strength is the shedding criterion for ice coating.The fluctuating wind speed time history of the tower line systemis first simulated,and then the fluctuating wind and the average wind are superimposed to generate the instantaneous wind speed and converted into wind load.The dynamic response of the transmission tower line systemunder iced coupling with different wind speeds and different thicknesses of ice coating was studied.This is the first attempt that the coupling dynamic response of the icing shedding and wind load for the transmission tower-line system is discussed in this paper.In addition,the dynamic characteristics of wind are included.In particular,the limiting mechanical conditions are considered.According to the simulation results,it is found:because of the ice shedding,the stress of the conductor changes obviously in the first 20 seconds,and the ground wire changes sharply in the first two seconds;the icing of the conductor(ground)wire is gradually deicing under the action of wind vibration;the displacement of tower top increases with the increase of wind speed and icing thickness. 展开更多
关键词 tower line system fluctuating wind ice shedding dynamic response wind-induced ice shedding
下载PDF
An Intelligent System for Real-Time Condition Monitoring of Tower Cranes 被引量:1
13
作者 Aaron K. Adik Wilson Wang 《Intelligent Control and Automation》 2019年第4期155-167,共13页
Reliability and safety are major issues in tower crane applications. A new adaptive neurofuzzy system is developed in this work for real-time health condition monitoring of tower cranes, especially for hoist gearboxes... Reliability and safety are major issues in tower crane applications. A new adaptive neurofuzzy system is developed in this work for real-time health condition monitoring of tower cranes, especially for hoist gearboxes. Vibration signals are measured using a wireless smart sensor system. Fault detection is performed gear-by-gear in the gearbox. A new diagnostic classifier is proposed to integrate strengths of several signal processing techniques for fault detection. A hybrid machine learning method is proposed to facilitate implementation and improve training convergence. The effectiveness of the developed monitoring system is verified by experimental tests. 展开更多
关键词 Adaptive NEURO-FUZZY systems MACHINE Learning DIAGNOSTICS PATTERN Classification tower CRANES Smart Sensors
下载PDF
PV-Wind-Diesel System for Energy Supply on Remote Area Applied for Telecommunication Towers in Comoros 被引量:1
14
作者 Fahad Maoulida Djedjig Rabah +1 位作者 Mohammed El Ganaoui Kassim Mohamed Aboudou 《Open Journal of Energy Efficiency》 2021年第2期50-72,共23页
The Comoros is an archipelago in the Indian Ocean located in the Mozambique Channel between the African continent and Madagascar. Geographically Comoros is composed of four islands: Grande Comores, Anjouan, Mohél... The Comoros is an archipelago in the Indian Ocean located in the Mozambique Channel between the African continent and Madagascar. Geographically Comoros is composed of four islands: Grande Comores, Anjouan, Mohéli and Mayotte (under French administration). Apart from Mayotte, the others three independent islands commonly known as the Union of the Comoros are suffering from energy stress since their independence year 1975 until nowadays. The energy supplied and distributed by the national electricity company, SONELEC produced by diesel engines, is not stable with so much load shedding all the time. This instability energy leads to a lack of a phone network in some telecommunications towers connected to grid. The majority of telecommunications towers are located in rural areas not connected to grid and running on diesel generators, which once again leads to a problem with the telecommunications network when diesel engines fail. The two competing companies which operate in the field of telecommunications in the Comoros, namely Comores Télécom, a national public company and Telma, the private one, are still unable to ensure the provision of the telecommunications network on a regular basis. This is why we propose in the present work, a sizing of hybrid system composed essentially of a diesel generator, a wind turbine and a photovoltaic solar system with storage in batteries for supplying telecommunications towers in order to permanently ensure the provision of the telecommunications network for the well-being of the population. Our future energy must be based on non-polluting energies with significant resources. Renewable energies are the best candidates but with intermittent production especially in rural areas not connected to the national electricity grid whose energy demand is more important to meet the needs of the population. The aim of this work is the sizing of a hybrid system composed of a diesel generator, a wind turbine and a photovoltaic solar system with storage in batteries for supplying telecommunications towers located in rural areas in the Comoros. In fact, to verify the performance of the hybrid system, a numerical study has been carried out with the HOMER 2.68 Beta software using meteorological data from the Comoros. The results obtained show that this hybrid combination is more profitable in the margin of economic cost and environmental assessments with a less expensive investment. These results also show a better optimization of Wind/PV/Battery of the hybrid system used, satisfying the demand and contributing to the preservation of the environment to fight against climate change with a low cost of energy. 展开更多
关键词 Hybrid system Renewable Energy HOMER Meteorological Data TELECOMMUNICATION towerS Rural Area
下载PDF
Thermodynamic Analysis of Double Effect Absorption System along with Boiler and Cooling Tower
15
作者 Saeed Sedigh Hamid Saffari Hamidreza Taleshbahrami 《Journal of Environmental Science and Engineering(A)》 2012年第2期261-270,共10页
Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermo... Many researchers have studied single and double effect absorption cycles based on first and second lows of thermodynamics But so far the relation of different parameters inside these cycles to the second law of thermodynamics in boiler and cooling tower has not been investigated. In this paper, a system comprised of a series flow double effect water-Lithium bromide absorption chiller, a boiler and a cooling tower is studied based on the first and second laws of thermodynamics, and also exergy analysis is investigated. For this purpose, mass and energy conservation laws governing the system are written, and coefficient of performance of the system, exergy destruction (loss) of each component and exergy efficiency have been calculated. 展开更多
关键词 Absorption chiller thermodynamic analysis cooling tower.
下载PDF
The Performance of Lightning Rod Arrester and Its Effect on the Top Potential of Tower for 500 kV Transmission System
16
作者 Jian’gang Gong Zhouyou Lin +2 位作者 Yangyong Xu Shen Zhao Qiang Zhang 《Journal of Power and Energy Engineering》 2014年第11期19-23,共5页
When the tower overhead is struck by the lightning impulse, the lightning current flows into the earth through the impedance of tower and the grounding resistance, which heightens potential of the tower overhead and p... When the tower overhead is struck by the lightning impulse, the lightning current flows into the earth through the impedance of tower and the grounding resistance, which heightens potential of the tower overhead and possibly induces insulator flashover. Lighting rod arrester is used to shield the tower and provide another routine for lightning current, decreasing the potential of tower overhead. In this paper, the performance of a 500 kV lighting rod arrester is tested used in AC transmission system under the current impulse. Besides, the influence of the lightning rod arrester performance on the top potential of tower is also studied. The results show that, when the rod arrester is connected to the tower, the top potential of tower can be obviously limited under the lightning strike. 展开更多
关键词 LIGHTNING Impulse Grounding Resistance LIGHTNING Rod Top POTENTIAL of tower Insulator FLASHOVER LIGHTNING Protection
下载PDF
Research on ETABS Steel Tower atop Building Structural System
17
作者 Wang Guangfeng 《International Journal of Technology Management》 2014年第7期48-52,共5页
Equipping steel tower atop building structural system at the top of high-rise buildings is applied increasingly. However, the earthquake disasters indicate that under seismic effect, the tower on the roof reacts stron... Equipping steel tower atop building structural system at the top of high-rise buildings is applied increasingly. However, the earthquake disasters indicate that under seismic effect, the tower on the roof reacts strongly to the earthquake, and the gazebo is damaged greatly under the condition that major structure has no earthquake damage. Based on analyzing the characteristics and application methods of ETABS software, for engineering projects, the paper uses ETABS software and simplified calculation method to calculate and make comparison analysis on steel tower atop building structure. The analysis results indicate that the method established in the paper has higher accuracy, which can meet the engineering requirements. 展开更多
关键词 high-rise buildings steel tower dynamic characteristics ETABS
下载PDF
The Integrated System of Aerial Photogrammetry and Tower Locations Optimization for Transmission Lines
18
作者 Xie Yuan, Pan Yijun, Fu Bin Northwest Power Design Institute 《Electricity》 1996年第4期45-48,共4页
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission... This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system. 展开更多
关键词 PRO The Integrated system of Aerial Photogrammetry and tower Locations Optimization for Transmission Lines
下载PDF
Safety Risk Assessment of Overturning Construction of Towering Structure Based on Cloud Matter–Element Coupled Model
19
作者 Yingxue Sang Fengxia Han +2 位作者 Qing Liu Liang Qiao Shouxi Wang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1973-1998,共26页
Rapid urbanization has led to a surge in the number of towering structures,and overturning is widely used because it can better accommodate the construction of shaped structures such as variable sections.The complexit... Rapid urbanization has led to a surge in the number of towering structures,and overturning is widely used because it can better accommodate the construction of shaped structures such as variable sections.The complexity of the construction process makes the construction risk have certain randomness,so this paper proposes a cloudbased coupled matter-element model to address the ambiguity and randomness in the safety risk assessment of overturning construction of towering structures.In the pretended model,the digital eigenvalues of the cloud model are used to replace the eigenvalues in the matter–element basic element,and calculate the cloud correlation of the risk assessment metrics through the correlation algorithm of the cloud model to build the computational model.Meanwhile,the improved hierarchical analysis method based on the cloud model is used to determine the weight of the index.The comprehensive evaluation scores of the evaluation event are then obtained through the weighted average method,and the safety risk level is determined accordingly.Through empirical analysis,(1)the improved hierarchical analysis method based on the cloud model can incorporate the data of multiple decisionmakers into the calculation formula to determine theweights,which makes the assessment resultsmore credible;(2)the evaluation results of the cloud-basedmatter-element coupledmodelmethod are basically consistent with those of the other two commonly used methods,and the confidence factor is less than 0.05,indicating that the cloudbased physical element coupled model method is reasonable and practical for towering structure overturning;(3)the cloud-based coupled element model method,which confirms the reliability of risk level by performing Spearman correlation on comprehensive assessment scores,can provide more comprehensive information of instances compared with other methods,and more comprehensively reflects the fuzzy uncertainty relationship between assessment indexes,which makes the assessment results more realistic,scientific and reliable. 展开更多
关键词 Cloud matter-element model clouded hierarchical analysis method towering structure overturning formwork construction risk assessment
下载PDF
Spray Effect on the Thermal Performances of a Dry Cooling Tower
20
作者 Zhe Geng Feng Feng +5 位作者 Shuzhen Zhang Jie Li Chengwei Liu Yang Li Tiantian Liu Suoying He 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2289-2304,共16页
Pre-cooling the inlet air of a dry cooling tower by means of a spray can improve the tower performance during periods of high temperature.To study the spray effect on the thermal performance of natural draft dry cooli... Pre-cooling the inlet air of a dry cooling tower by means of a spray can improve the tower performance during periods of high temperature.To study the spray effect on the thermal performance of natural draft dry cooling towers(NDDCTs),in this study 3-D numerical simulations of such a process have been conducted using Fluent 16.2(a two-way coupled Eulerian-Lagrangian approach).The considered NDDCT is 120 m high and only half system is simulated due to its structural symmetry.Three different spray strategies have been investigated at a typical crosswind speed of 4 m/s,which is the most frequent wind speed.The results have shown that:(1)The three implemented spray strategies can improve the thermal performance of the studied NDDCT with a vary-ing degree of success.In one case,the heat rejection rate can be increased by 35.2%,and the tower outlet water temperature can be decreased by 2.1℃ when compared with the no spray case;(2)To improve the thermal per-formance of the NDDCT using a small amount of water,the design of the spray pre-cooling system must include more nozzles on the windward and fewer or even no nozzles on the leeward sides of the NDDCT. 展开更多
关键词 Natural draft dry cooling tower spray strategy thermal performance SIMULATION
下载PDF
上一页 1 2 119 下一页 到第
使用帮助 返回顶部