期刊文献+
共找到14,964篇文章
< 1 2 250 >
每页显示 20 50 100
Investigation of lacrimal sac space-occupying lesions using color doppler ultrasound, computed tomography, and computed tomography dacryocystography
1
作者 Zhen-Bin Qian Bo Yu +3 位作者 Ye Yang Wei Fang Jian-Li Dong Li-Qing Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1224-1230,共7页
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T... AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG. 展开更多
关键词 lacrimal sac computed tomography computed tomography dacryocystography color doppler ultrasound space-occupying lesions
下载PDF
The value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications 被引量:7
2
作者 Dao-Zhong Huang Gui-Rong Le +4 位作者 Qing-Ping Zhang Kai-Yan Li Qi-Fa Ye Wei Zhu Yun-Chao Chen the Department of Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2003年第1期54-58,共5页
OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation... OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation were examined by using color Doppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepatic parenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-average blood flow velocity (TAV), resistance index (RI) and diameter of the bile duct. RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17 patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitude single-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepatic arterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepatic artery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosis in the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the 41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of 20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worsening gradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15 patients (75%) and others in 3 patients (15%). CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantation and postoperative complications. 展开更多
关键词 ULTRASONOGRAPHY doppler color liver transplantation COMPLICATION
下载PDF
Hemodynamic analysis of esophageal varices in patients with liver cirrhosis using color Doppler ultrasound 被引量:24
3
作者 Feng-Hua Li Jing Hao +2 位作者 Jian-Guo Xia Hong-Li Li Hua Fang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第29期4560-4565,共6页
AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patien... AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding. 展开更多
关键词 HEMODYNAMICS Esophageal varices Liver cirrhosis color doppler ultrasound
下载PDF
Measurements Of Cerebral Blood Flow in Postasphyxiated Newborns by Color Doppler Imaging(CDI) 被引量:7
4
作者 常立文 汪元芳 刘婉君 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第4期249-252,共4页
Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the... Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the anterior, middle and posterior cerebral arteries were studied. The results showed evidently lower systolic amplitude in patients than that in normal subjects. End diastolic amplitude was zero in part of vessels, and values of bloed flow variables were all lower in day 1 of the life as compared with the control groups. Frequency spectrum recovered to normal patterns in 9 survived infants in day 2. but blood flow variables recovered to normal by day 7. Values of resistance index (RI) rose to 1 in some vessels of moderate hypoxic ischemic encephalopathy (HIE) infants and stayed at 1 in the severe HIE infants. It is concluded that low CBF plays a key role in brain damage of post-asphyxiated newborns and RI may be an important parameter in the evaluation prognosis. 展开更多
关键词 asphyxiated newborns cerebral blood flow ultrasound imaging color doppler
下载PDF
Different hemodynamic responses by color Doppler ultrasonography studies between sildenafil non-responders and responders 被引量:3
5
作者 Shih-Tsung Huang Ming-Li Hsieh 《Asian Journal of Andrology》 SCIE CAS CSCD 2007年第1期129-133,共5页
Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patien... Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patients aged 22-79 years were enrolled into the present study. Thirty-eight (55.1%) men with ED who did not respond to four attempts of treatment with 100 mg sildenafil after re-education were classified as sildenafil non-responders. A com- bination of three vasodilator drugs, 1.25 mg papaverine, 0.4 mg phentolamine and 5 ug prostaglandin E1, was given by intracavernous injection before penile Doppler ultrasonography was carried out. The erectile response to intracavernous injection and vascular parameters including peak systolic velocity (PSV), resistance index (RI), end diastolic velocity (EDV) and cavernosa artery diameter (CD) were measured and the results between sildenafil nonresponders and responders were compared. Results: No statistical difference in vascular parameters measured by Doppler ultrasonography studies between non-responders and responders was noted. Sildenafil non-responders had a poorer penile rigidity response to intracavernous injection than responders (P 〈 0.05). Among patients with adequate PSV (〉 30 cm/s) and abnormal EDV (〉 5 cm/s), individuals in the non-responder group had fewer positive responses to intracavernous vasodilator injection than in the responder group (35.3% vs. 72.2%, P 〈 0.05). Advanced age and comorbidity with diabetes mellitus were significantly associated with sildenafil non-response (P 〈 0.05). Conclusion: Sildenafil non-responders were characterized by a poorer penile rigidity response to intracavernous injection and had an associated impaired veno-occlusive mechanism. Advanced age and comorbidity with diabetes mellitus were two common factors associated with non-response. 展开更多
关键词 color doppler ultrasonography erectile dysfunction IMPOTENCE sildenafil citrate ULTRASONOGRAPHY
下载PDF
The Study of Ovarian Artery Hemodynamics in Patients with Infertility by Color Doppler Energy 被引量:2
6
作者 肖先桃 乐桂蓉 +1 位作者 张友耿 黎春蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第1期42-43,共2页
Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI... Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility. 展开更多
关键词 ovarian artery color doppler flow imaging color doppler energy resistance index pulsatility index INFERTILITY
下载PDF
Color Doppler ultrasonographic examination on the relationship between the gallbladder bed and major branch of the middle hepatic vein 被引量:3
7
作者 Wei-Zhong Zhang, Jie Shen, Jue-Xing Xie and Hong Zhu Taizhou, China Departments of Surgery and Ultrasonography , Taizhou First People’s Hospital, Taizhou 318020, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2005年第2期299-301,共3页
BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the ... BACKGROUND: There is a controversy about the risk of injury to the branch of the middle hepatic vein during lapa- roscopic cholecystectomy. This study was conducted to further investigate the relationship between the gallbladder bed and the branch of the middle hepatic vein. METHODS: Color Doppler ultrasound was used to exa- mine the anatomical relationship between the gallbladder bed and the branches of the middle hepatic vein in 143 healthy volunteers. RESULTS: Not all the middle hepatic vein extended close to the gallbladder bed, the branches and gallbladder beds in 23 subjects were not in the same plane during ultrasound scanning. In 21 of the 143 subjects the branch of the middle hepatic vein was completely adherent to the gallbladder bed with a diameter ranging from 1.2 mm to 3.6 mm. In 10 subjects the branches of the middle hepatic vein traversed approximately 1.0 mm from the gallbladder bed with a dia- meter ranging from 1.6 mm to 3.0 mm. CONCLUSIONS: In most subjects the branch of the middle hepatic vein and the gallbladder bed are well separated. Only patients with large branches of the middle hepatic vein close to the gallbladder bed are at risk of hemorrhage during laparoscopic cholecystectomy. 展开更多
关键词 laparoscopic cholecystectomy color doppler ultrasound hepatic vein
下载PDF
FEASIBILITY STUDY OF AN ULTRASOUND CONTRAST AGENT(LEVOVIST) IN COLOR DOPPLER IMAGING OF LIVER NEOPLASMS 被引量:6
8
作者 姜玉新 戴晴 +4 位作者 刘吉斌 张缙熙 常欣 蔡胜 谭莉 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第3期167-169,共3页
The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tu... The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms. 展开更多
关键词 ultrasound contrast agent color doppler imaging liver neoplasms
下载PDF
Clinical Evaluation of Color Doppler Ultrasound in Selecting the Optimal Treatment Modality for Infantile Hemangioma 被引量:6
9
作者 MinLi JuanLiu +2 位作者 ValeskaMaya DanLuo Bingrong Zhou 《Chinese Medical Sciences Journal》 CAS CSCD 2017年第2期100-106,共7页
Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler u... Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler ultrasound guidance in choosing the optimal treatment modality. Methods Infantile patients who were clinical diagnosed as hemangiomas were randomly divided into group A, who had color Doppler ultrasound examinations before the treatment, and group B who had the treatment without ultrasound evaluation. Patients in the group A were assigned into subgroups according to the depth of lesion by sonography: group A-1 for those who had a lesion depth 〈1.2 mm, and took intense pulsed light therapy; group A-2 for those who had a lesion depth ≥1.2mm and 〈 3 mm, and took long pulse 1064 nm Nd:YAG laser therapy; group A-3 for those who had a lesion depth ≥3mm and 〈5 mm, and were treated by IPL combined with long pulse 1064 nm Nd:YAG laser treatment; Group A-4 for those who had a lesion depth ≥5 mm, and took lauromacrogol injection therapy. Patients in the group B took long pulse 1064 nm Nd:YAG laser treatment without preoperative ultrasound evaluation. The efficacy and adverse reactions of the treatments between the groups were evaluated and compared statistically. Results Totally 113 patients with 128 skin lesions were enrolled in this study, 85 in the group A (mean age 6.8±7.9 months) and 28 in the group B (mean age 6.9±9.9 months). The mean depth of hemangioma was 3.3±1.1 mm in the group A, ranging from 0.5-7.8 mm, with 0.8±0.4 mm, 2.2±0.4 mm, 4.2±0.6 mm and 6.2±0.7 mm in group A1, A2, A3 and A4, respectively. The cure rates and effective rates in the group A were significantly higher than those in the group B (cure rates: 64.5% vs 56.3%, U=3.378, P=0.045; effective rates: 89.5% vs 78.1%, U=4.163, P=0.041). The adverse effect rates of the group A (vesicle 20.0%, pigmentation 46.9%, scarring 17.7%) were lower than those of the group B (vesicle 21.9%, pigmentation 60.4%, scarring 25.0%). Incidences of pigmentation and scarring were statistically significantly different (U=3.884, P=0.034, and U=4.016, P=0.032 respectively) between the two groups. Conclusion With the guidance of color Doppler ultrasound, the efficacy and safety of long pulse 1064 nmNd:YAG laser, intense pulsed light, and lauromacrogol injection in the treatment of infantile hemangioma have better outcomes compared to laser treatment alone without preoperative ultrasound examination. 展开更多
关键词 color doppler ultrasound infantile hemangioma Nd:YAG laser intense pulsed light LAUROMACROGOL
下载PDF
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
10
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color doppler flow imaging aortic regurgitation
下载PDF
Use of color Doppler ultrasonography in the diagnosis of anomalous connection in pancreatobiliary disease 被引量:7
11
作者 Hiroki Kawashima Yoshiki Hirooka +7 位作者 Akihiro Itoh Senju Hashimoto Terutomo Itoh Kazuo Hara Akira Kanamori Naoki Ohmiya Yasumasa Niwa Hidemi Goto 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第7期1018-1022,共5页
AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallb... AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening. 展开更多
关键词 color doppler ultrasonography Anomalous connection in pancreatobiliary disease Gallbladder cancer Gallbladder wall blood flow Endoscopic ultrasonography
下载PDF
Correlation Study of Color Doppler Examination of Deep Veins of Both Lower Extremities Combined with Fibrinolysis System in Hypertension during Pregnancy 被引量:4
12
作者 Chundong Qiu Haiyan Chen +3 位作者 Xiaohua Huang Xiaoling Kong Chong Liang Chunhong Qiu 《Open Journal of Obstetrics and Gynecology》 2020年第8期981-989,共9页
<strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation be... <strong>Objective</strong><span style="font-family:Verdana;"><strong>:</strong></span><span style="font-family:Verdana;"> To investigate the correlation between deep static color Doppler ultrasound of both lower extremities combined with fibrinolytic system detection in pregnancy-induced hypertension.</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Methods</span></b><b><span style="font-family:Verdana;">:</span></b><span style="font-family:Verdana;"> A total of 70 normal pregnant women, 70 pregnant women with hypertension during pregnancy, and 50 healthy non-pregnant women in the same period were selected as the research objects. The deep veins of both lower limbs were examined by Rili Erlangshen’s color Doppler ultrasound diagnostic instrument (CDU),</span><span style="font-family:""> </span><span style="font-family:""><span style="font-family:Verdana;">and the </span><span style="font-family:Verdana;">fibrinolysis system was tested by enzyme-linked immunosorbent assay (ELISA) </span><span style="font-family:Verdana;">method and </span><a name="OLE_LINK12"></a><span style="font-family:Verdana;">automatic hemagglutination analyzer.</span><b><span style="font-family:Verdana;"> Results</span></b></span><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Compared with the non-pregnant group, the inner diameters of the left/right femoral vein (CFV) and popliteal vein (POV) in the normal pregnancy group and the pregnancy-induced hypertension group were significantly widened, and the peak blood flow spectrum was significantly reduced. The difference was statistically significant (P < 0.01);FIB, PLG, t-PA, PAI, D-Dimer were significantly increased, the difference was statistically significant (P < 0.01);Compared with the normal pregnancy group, the inner diameter of the left/right femoral vein (CFV) in the hypertensive pregnancy group was significantly wider than that in the normal pregnancy group, and the peak value of the left/right POV blood flow spectrum was significantly lower than that in the normal pregnancy group,</span><span style="font-family:""> </span><span style="font-family:Verdana;">the difference w</span><span style="font-family:Verdana;">as</span><span style="font-family:Verdana;"> statistically significant (P < 0.01)</span><span style="font-family:Verdana;">,</span><span style="font-family:""> <span style="font-family:Verdana;">while the left/right popliteal vein (POV) inner diameter, left/right CFV blood flow peak value did not change significantly from the normal pregnancy</span><span style="font-family:Verdana;"> grou</span></span><span style="font-family:Verdana;">p, </span><span style="font-family:Verdana;">and the difference was not statistically significant (P > 0.05);FIB, PLG, PAI, D-Dimer of the hypertensive disease group during pregnancy significantly increased, the difference was statistically significant (P < 0.01), while t-PA was not statistically significant (P > 0.05).</span><span style="font-family:""> </span><b><span style="font-family:Verdana;">Conclusion</span></b><b><span style="font-family:Verdana;">:</span></b><b><span style="font-family:""> </span></b><span style="font-family:Verdana;">Normal pregnant women have a hypercoagulable state compared with healthy non-pregnant women, and pregnant women with hypertension during pregnancy are more likely to be in a pre-thrombotic state than pregnant women with normal pregnancy. Deep vein CDU examination of both lower extremities combined with blood fibrinolysis monitoring is of great value in the prevention and treatment of hypertension during pregnancy.</span> 展开更多
关键词 Hypertension during Pregnancy Prothrombotic State color doppler Ultrasound Fibrinolysis Index
下载PDF
Evaluation of diagnosis and curative criterion for concussion patients by color three-dimensional trascrani doppler 被引量:1
13
作者 肖兴义 薛贯生 +2 位作者 李春玲 郭新红 宋燕 《中国组织工程研究》 CAS CSCD 2001年第7期154-155,共2页
Objective In order to offer a noninvasive and objective examination method for assessing the clinical diagnosis and eurative criterion of concussion patients,the patients color three-dimensional transcranial doppler... Objective In order to offer a noninvasive and objective examination method for assessing the clinical diagnosis and eurative criterion of concussion patients,the patients color three-dimensional transcranial doppler(3D-TCD)characteristic at deferent phases,parameter and clincal manifestation were studied.Method Parameter of Median Cerebral Artery(MCA),Base Artery(BA),the average peak forwand velocity of cerebral blood flow,train figure were tested by 3D-TCD within 24 hours,3-6 days and at the end of treatment,respectively.The results were compared with clinical diagnoses and curative criterion.Result Among 135 patients who had clinically diagnosed concussion,agreeable diagnoses 101 cases,basically agreeable diagnoses 12 cases,disagreeable diagnosis 22 cases(16.2%).At the end of treatment, according to clinical determination 96 cases(71.1%)were cured,39 cases(28.9%)were improved.Wave train character,figure and diagnoses parameter of cerebral spasm caused by concussion were suggested.Conclusion To be one of the diagnostic bases and curative criterion,3D-TCD technology is performable.Meanwhile,it is a new testing objective technique for assessing curative and determining prognosis. 展开更多
关键词 cerebral CONCUSSION color three-dimensioal TRANSCRANIAL doppler diagnostic basis CURATIVE CRITERION
下载PDF
Paper Clinical Value of Color Doppler Ultrasonography in Diagnosis of Lower Extremity Arterial Disease of Diabetes Patients 被引量:2
14
作者 Jianyu Zhang Haijiao Mao 《Journal of Biosciences and Medicines》 2020年第6期209-214,共6页
<div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. &l... <div style="text-align:justify;"> <strong>Objective:</strong> To evaluate the diagnostic value of color Doppler ultrasound in the diagnosis of diabetic lower extremity vascular diseases. <strong>Methods: </strong>48 patients with diabetic lower extremity vascular disease admitted in our hos-pital from September 2018 to September 2019 were included in the study and divided into the observation group, and another 48 patients with the same period of health examination in our hospital were included in the study and divided into the control group. Both groups used color Doppler ultrasound to detect the blood flow of lower extremity vessels. The incidence of blood flow, vascular diameter and stenosis, occlusion and arteriosclerosis of the lower extremity were observed. <strong>Results:</strong> The blood flow and vascular di-ameter of the lower extremity in the observation group were significantly lower than those in the control group (p < 0.05). The incidence of vascular stenosis, vascular occlusion, thrombus, intimal thickening and plaque in the observation group was 85.42%, 22.92%, 10.42% and 93.75% respectively, which was significantly higher than that in the control group was 10.42%, 0.00%, 0.00% and 14.58% (p < 0.05). The incidence of lower extremity vascular lesions in the observation group was significantly higher than that in the control group (p < 0.05). <strong>Conclusion:</strong> Color Doppler ultrasound is of high diagnostic value in the diagnosis of diabetic lower extremity vascular diseases, and can be used to determine the blood flow of the lower extremity and the inner diameter of popliteal artery, thigh artery, dorsalis pedis artery and so on. At the same time, it can also clearly show the specific situation of vascular occlusion, arteriosclerosis and thrombosis, which is of great signif-icance for the prevention and diagnosis of lower extremity vascular lesions, and can provide the basis for the treatment of lower extremity vascular lesions. </div> 展开更多
关键词 Super color doppler Ultrasound Diabetic Complications Lower Extremity Vascular Disease Diagnostic Value
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
15
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
The Diagnostic Value of Color Doppler Ultrasound and Grey Scale Sonography in Predicting the Malignancy of Thyroid Nodules 被引量:2
16
作者 Hamad Elniel H. Eltyib Sameh A. Aborizk +2 位作者 Hanan A. Albalawi Afaf S. Almotairi Arwa H. Aidrus 《Open Journal of Radiology》 2020年第4期215-222,共8页
Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. ... Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively). 展开更多
关键词 ULTRASOUND Thyroid Nodules MALIGNANT color doppler Fine Needle Aspiration
下载PDF
Color Doppler sonography and angioscintigraphy in hepatic Hodgkin's lymphoma 被引量:2
17
作者 Mirjana V Stojkovi Vera M Artiko +10 位作者 Irena B Radoman Slavko J Knezevi Snezana M Luki Mirko D Kerkez Nebojsa S Leki Andrija A Anti Marinko M Zuvela Vitomir I Rankovi Milorad N Petrovi Dragana P obi Vladimir B Obradovi 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第26期3269-3275,共7页
AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin's hepatic lymphoma. METHODS: The research included patients with a dia... AIM: To estimate the characteristics of Color Doppler findings and the results of hepatic radionuclide angiography (HRA) in secondary Hodgkin's hepatic lymphoma. METHODS: The research included patients with a diagnosis of Hodgkin's lymphoma with metastatic focal lesions in the liver and controls. Morphologic characteristics of focal liver lesions and hemodynamic parameters were examined by pulsed and Color Doppler in the portal, hepatic and splenic veins were examined. Hepatic perfusion index (HPI) estimated by HRA was calculated. was observed. Lesions were mostly hypoechoic and mixed, solitary or multiple. Some of the patients presented with dilated splenic veins and hepatofugal blood flow. A pulse wave was registered in the centre and at the margins of lymphoma. The average velocity of the pulse wave was higher at the margins (P 〉 0.05). A continuous venous wave was found only at the margins of lymphoma. There was no linear correlation between lymphoma size and velocity of pulse and continuous wave (r = 390, P 〈 0.01). HPI was significantly lower in patients with lymphomas than in controls (P 〈 0.05), pointing out increased arterial perfusion in comparison to portal perfusion. CONCLUSION: Color Doppler ultrasonography is a sensitive method for the detection of neovascularization in Hodgkin's hepatic lymphoma and estimation of its intensity. Hepatic radionuclide angiography can additionally help in the assesment of vascularisation of liver lesions. 展开更多
关键词 color doppler ultrasonography Hodgkin's disease LYMPHOMA Liver Radionuclide angiography VELOCITY Hepatic artery Portal vein Blood flow SPLENOMEGALY
下载PDF
Assessment of Uterine Receptivity by Endometrial and Subendometrial Blood Flows Measured by Vaginal Color Doppler Ultrasound in Women Undergoing IVF Treatment 被引量:1
18
作者 Min-zhi GAO Xiao-ming ZHAO +3 位作者 Wen-ying LI Gui-mei LIU Xiao-feng JIA Hui-qin ZHANG 《Journal of Reproduction and Contraception》 CAS 2007年第3期205-212,共8页
Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infert... Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF. 展开更多
关键词 endometrial and subendometrial blood flows endometrial receptivity in vitro fertilization-embryo transfer (IVF) color doppler ultrasound
下载PDF
COLOR DOPPLER ULTRASONOGRAPHY APPEARANCES OF RENAL VEIN THROMBOSIS AND ITS DIAGNOSTIC VALUE 被引量:1
19
作者 Sheng Cai Guang-xi Zhong +3 位作者 Jian-chu Li Yu Xia Hui-jun Li Yu-xin Jiang 《Chinese Medical Sciences Journal》 CAS CSCD 2007年第1期17-21,共5页
Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions... Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11); in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT. 展开更多
关键词 color doppler ultrasonography renal vein thrombosis DIAGNOSIS
下载PDF
The Role of Color Doppler Ultrasound Arterial Mapping for Decision Making in the Treatment of Patients with Lower Extremity Peripheral Arterial Disease 被引量:1
20
作者 Ali Babaei Jandaghi Zahra Mardanshahi +5 位作者 Ahmad Alizadeh Iraj Baghi Hossein Hemmati Narges Tabarzan Baboli Shabnam Alizadeh Arasi Amin Keshavarzzirak 《Surgical Science》 2013年第10期415-420,共6页
Purpose: To assess the efficacy of color Doppler imaging for decision making in the treatment of patients with lower extremity peripheral arterial disease (PAD) compared to digital subtraction angiography (DSA). Mater... Purpose: To assess the efficacy of color Doppler imaging for decision making in the treatment of patients with lower extremity peripheral arterial disease (PAD) compared to digital subtraction angiography (DSA). Materials and Methods: Color Doppler scan was done on patients suspected for lower limb PAD, a day prior to the DSA which was done by a vascular surgeon. Also, for the patients who were candidates for endovascular intervention based on the color Doppler arterial mapping results, endovascular interventions were performed at the same time if the DSA findings are correlated with the color Doppler map. The grading for evaluated segments was normal, insignificant stenosis (<50%), hemodynamically significant stenosis (≥50%) and occlusion. We yielded the diagnostic efficacy indices of Doppler for detecting arterial stenosis in each 18 different arterial segments below the renal arteries including, infrarenal aorta, common and external iliac, common femoral, superficial femoral (proximal, middle and distal segments), deep femoral, popliteal artery, tibioperoneal trunk, anterior and posterior tibial arteries (proximal, middle and distal segments) and peroneal artery (proximal and distal segments). Then, we yielded the kappa agreement between Doppler and DSA findings considering the grade of stenosis in 18 arterial segments separately. Results: Totally 115 lower extremities (2045 arterial segments) were evaluated in 90 patients [mean age: 60.8 ± 8.9 (range: 47 - 84 years old)] of which 68 (75.6%) were men. The sensitivity of color Doppler for all arterial segments was 90% or higher except for common iliac artery, distal segment of superficial femoral artery and proximal segments of anterior and posterior tibialis and peroneal arteries. However, the specificity was 89% or higher, in all arterial segments. Kappa agreement was 0.72 or higher in all segments (All P-Values 0.001). Conclusion: This study suggests that considering excellent capability of color Doppler sonography in the evaluation of lower extremity arterial disease, color Doppler arterial mapping is sufficient for decision making in the treatment of these patients and can reduce the rate of diagnostic angiography. 展开更多
关键词 Lower EXTREMITY Peripheral ARTERIAL Disease color doppler SONOGRAPHY ARTERIAL MAPPING Digital SUBTRACTION ANGIOGRAPHY
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部