To address uncertainty as well as transient stability constraints simultaneously in the preventive control of windfarm systems, a novel three-stage optimization strategy is established in this paper. In the first stag...To address uncertainty as well as transient stability constraints simultaneously in the preventive control of windfarm systems, a novel three-stage optimization strategy is established in this paper. In the first stage, the probabilisticmulti-objective particle swarm optimization based on the point estimate method is employed to cope with thestochastic factors. The transient security region of the system is accurately ensured by the interior point methodin the second stage. Finally, the verification of the final optimal objectives and satisfied constraints are enforcedin the last stage. Furthermore, the proposed strategy is a general framework that can combine other optimizationalgorithms. The proposed methodology is tested on the modified WSCC 9-bus system and the New England 39-bussystem. The results verify the feasibility of the method.展开更多
Transient control law ensures that the aeroengine transits to the command operating state rapidly and reliably. Most of the existing approaches for transient control law design have complicated principle and arithmeti...Transient control law ensures that the aeroengine transits to the command operating state rapidly and reliably. Most of the existing approaches for transient control law design have complicated principle and arithmetic. As a result, those approaches are not convenient for application. This paper proposes an extrapolation approach based on the set-point parameters to construct the transient control law, which has a good practicability. In this approach, the transient main fuel control law for acceleration and deceleration process is designed based on the main fuel flow on steady operating state. In order to analyze the designing feature of the extrapolation approach, the simulation results of several different transient control laws designed by the same approach are compared together. The analysis indicates that the aeroengine has a good performance in the transient process and the designing feature of the extrapolation approach conforms to the elements of the turbofan aeroengine.展开更多
The existing research into hybrid electric vehicle(HEV) control is mainly focussed on the optimisation of the power distribution between a conventional internal combustion engine(ICE) and an alternative power source(u...The existing research into hybrid electric vehicle(HEV) control is mainly focussed on the optimisation of the power distribution between a conventional internal combustion engine(ICE) and an alternative power source(usually a battery pack), however,transient control, which is a key technique that affects both fuel economy and the drivability of the HEV, has not been fully addressed. Especially in dual-mode power-split HE Vs, due to the different dynamic characteristics of the actuators in the transmission, and its complicated speed-torque relationship, transient control also affects the precision of power distribution and the speed of response of the electric output power. To improve the transient control performance, the design of an economic model predictive control(EMPC)-based transient controller for a dual-mode power-split HEV is developed. By incorporating an experimental identification model of a diesel ICE in a control-oriented transmission model, a better coordination among the actuators involved in HEV transmission can be achieved. Moreover, an ICE efficiency index is also added to the objective function to improve ICE fuel efficiency during this transient process. Then, a fast MPC method is applied to reduce the on-line computation effort required of the proposed control algorithm. By the flexible application of the EMPC and an innovative ICE model which is suited to the control-oriented model in EMPC, the transient control performance was improved. The effectiveness,and the real-time performance,of the control algorithm are validated by way of MATLABTM/Simulink-based simulations,as well as test-bed experiments combined with the use of the RapidECU platform.展开更多
A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than ...A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than 0.5dB excursion and 0.25dB offset.展开更多
Non-alcoholic fatty liver disease(NAFLD) is the most common cause of chronic liver disease worldwide. Currently, the routinely used modalities are unable to adequately determine the levels of steatosis and fibrosis(la...Non-alcoholic fatty liver disease(NAFLD) is the most common cause of chronic liver disease worldwide. Currently, the routinely used modalities are unable to adequately determine the levels of steatosis and fibrosis(laboratory tests and ultrasonography) or cannot be applied as a screening procedure(liver biopsy). Among the non-invasive tests, transient elastography(Fibro Scan?, TE) with controlled attenuation parameter(CAP) has demonstrated good accuracy in quantifying the levels of liver steatosis and fibrosis in patients with NAFLD, the factors associated with the diagnosis and NAFLD progression. The method is fast, reliable and reproducible, with good intra- and interobserver levels of agreement, thus allowing for population-wide screening and disease follow-up. The initial inability of the procedure to accurately determine fibrosis and steatosis in obese patients has been addressed with the development of the obese-specific XL probe. TE with CAP is a viable alternative to ultrasonography, both as an initial assessment and during follow-up of patients with NAFLD. Its ability to exclude patients with advanced fibrosis may be used to identify low-risk NAFLD patients in whom liver biopsy is not needed, therefore reducing the risk of complications and the financial costs.展开更多
The simulation model of a valve control hydraulic system with long pipe isestablished in Simulink4.0, and then the step responses of the systems with difference pipeparameters are investigated by simulation. Simulatio...The simulation model of a valve control hydraulic system with long pipe isestablished in Simulink4.0, and then the step responses of the systems with difference pipeparameters are investigated by simulation. Simulation results show that the long pipes will slowdown the step response of system and make it fluctuate periodically. The results of simulationconform to the results of experiment on the whole, which proves the mathematic model is correct.展开更多
We theoretically analyze the transient properties of a probe field absorption and dispersion in a coupled semiconductor double-quantum-dot nanostructure.We show that in the presence of the Gaussian laser beams,absorpt...We theoretically analyze the transient properties of a probe field absorption and dispersion in a coupled semiconductor double-quantum-dot nanostructure.We show that in the presence of the Gaussian laser beams,absorption and dispersion of the probe field can be dramatically influenced by the relative phase between applied fields and intensity of the Gaussian laser beams.Transient and steady-state behaviors of the probe field absorption and dispersion are discussed to estimate the required switching time.The estimated range is between 5-8 ps for subluminal to superluminal light propagation.展开更多
Transient response and its influence factors are investigated and a methodfor attenuating the transient response is developed by means of a time varying model.The system gain matrix is obtained by choosing weighting m...Transient response and its influence factors are investigated and a methodfor attenuating the transient response is developed by means of a time varying model.The system gain matrix is obtained by choosing weighting matrices and solving the timevarying Riccati equation. Control forces are applied to the system via a feed back loop.Comparisons of responses with and without control are made. The results show that thetransienl and steady state responses are significantly suppressed in the close loop systemand control forces are very small.展开更多
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt...A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.展开更多
By applying a nonlinear control and arranging a transient process, the initiative error of the pneumatic servo positioning system is reduced largely, and a larger gain of the controller is used to improve the respondi...By applying a nonlinear control and arranging a transient process, the initiative error of the pneumatic servo positioning system is reduced largely, and a larger gain of the controller is used to improve the responding speed of the system at the same damping ratio. Therefore, a compromise is made among the responding speed, overshoot, robustness, adaptability and stability. In addition, a dynamic output feedback controller, including position velocity and acceleration (PVA) feedback, is designed to improve the performance of the system. And a nonlinear controller is reconstructed based on the linear output feedback controller to decrease noises and disturbances. The dynamic responses of the system are simulated and tested. Results show that the error is kept within 0.02 mm under different mass loads and the positioning transient process is smooth, without overshoot and speedy.展开更多
Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized...Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized in space by finite center difference approximation, then the nonlinear ordinal differential equations were obtained. A hybrid method involving the combination of the Newmark method and the pseudo-force strategy was proposed to analyze the nonlinear transient response of the inclined cable-dampers system subjected to arbitrary dynamic loading. As an example, two typical stay cables were calculated by the present method. The results reveal both the validity and the deficiency of the viscoelasticity damper for vibration control of stay cables. The efficiency and accuracy of the proposed method is also verified by comparing the results with those obtained by using Runge-Kutta direct integration technique. A new time history analysis method is provided for the research on the stay cable vibration control.展开更多
AIM: To study the diagnostic value of controlled attenuation parameter (CAP), evaluated by transient elastography, for liver steatosis in patients with chronic hepatitis B (CHB).
Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized...Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized in space by finite center difference approximation, then the nonlinear ordinal differential equations were obtained. A hybrid method involving the combination of the Newmark method and the pseudo-force strategy was proposed to analyze the nonlinear transient response of the inclined cable-dampers system subjected to arbitrary dynamic loading. As an example, two typical stay cables were calculated by the present method. The results reveal both the validity and the deficiency of the viscoelasticity damper for vibration control of stay cables. The efficiency and accuracy of the proposed method is also verified by comparing the results with those obtained by using Runge-Kutta direct integration technique. A new time history analysis method is provided for the research on the stay cable vibration control.展开更多
A new approach of generating transient chaos from two-dimensional(2D) continuous autonomous systems within finite time is presented.Based on an absolute-value switching law,the phenomenon of transient chaos takes pl...A new approach of generating transient chaos from two-dimensional(2D) continuous autonomous systems within finite time is presented.Based on an absolute-value switching law,the phenomenon of transient chaos takes place by switching between three 2D systems.Basic dynamic behavior of the systems is investigated.Numerical examples illustrate the validity of the results.展开更多
By Green's function method we show that the water hammer (WH) can be analytically predicted for both laminar and turbulent flows (for the latter, with an eddy vis- cosity depending solely on the space coordinates...By Green's function method we show that the water hammer (WH) can be analytically predicted for both laminar and turbulent flows (for the latter, with an eddy vis- cosity depending solely on the space coordinates), and thus its hazardous effect can be rationally controlled and mini- mized. To this end, we generalize a laminar water hammer equation of Wang et al. (J. Hydrodynamics, B2, 51, 1995) to include arbitrary initial condition and variable viscosity, and obtain its solution by Green's function method. The pre- dicted characteristic WH behaviors by the solutions are in excellent agreement with both direct numerical simulation of the original governing equations and, by adjusting the eddy viscosity coefficient, experimentally measured turbulent flow data. Optimal WH control principle is thereby constructed and demonstrated.展开更多
BACKGROUND: Recent researches demonstrate that damage of executive function is an early manifestation of vascular cognitive disorder. OBJECTIVE: To investigate the executive functions of patients with transient isch...BACKGROUND: Recent researches demonstrate that damage of executive function is an early manifestation of vascular cognitive disorder. OBJECTIVE: To investigate the executive functions of patients with transient ischemic attack (TIA). DESIGN: Case control. SETTING: Department of Neurology, the First Affiliated Hospital of Xinxiang Medical College. PARTICIPANTS: A total of 83 TIA patients (46 males and 37 females, aged 32 - 74 years) were selected from Department of Neurology, the First Affiliated Hospital of Xinxiang Medical College from July 2005 to December 2006. The diagnosis of TIA was established by the criteria of cerebrovascular diseases made by the Fourth National Cerebrovascular Disease Meeting. In these cases, forty-five patients (54%) were involved in internal carotid artery, and thirty-eight patients (46%) were involved in vertebral basilar system. Fifty healthy adults (Control group: 28 males and 22 females, aged 32 - 74 years) were chosen from retiree in community and family of patients. All of them were right-handedness, without cerebrovascular disease, cerebral trauma, inborn oligophrenia, and heating and visual disorders; also they had no anxiety and depression nearly one week. In addition, all the subjects cooperated with examination. METHODS: After TIA diagnosis, all patients received neuropsychological examination, including attention and inhibition, working memory, flexibility, planning and diversion, based on Stroop tests (C and CW) and the Wisconsin card sorting tests (WCST). ① WCST test: The edition revised by Nelson was used. We would take the times of sorting, incorrect response, persistent incorrect response, and randomly incorrect response as the index of evaluation.② Stroop tests: The edition revised by Trenarry was used and this test had two types: form color and form color-word. Their incorrect response and response time were recorded for data analysis in the end. MAIN OUTCOME MEASURES: Results of WCST test and Stroop tests. RESULTS: A total of 83 TIA patients and 50 healthy subjects were involved in the final analysis. Items of Stroop tests, including response time of Stroop-C test, incorrect response of Stroop-C test, response time of Stroop-CW test and incorrect response of Stroop-CW test, and items of WCST, including incorrect response, persistent incorrect response and random incorrect response, between internal carotid artery system and vertebral basilar artery system were (93.87±24.39) s, 3.16±3.97, (228.46±68.13) s, 12.91 ± 10.56, 55.42± 20.38, 26.58± 10.41, 28.62±11.22; (96.76±24.75) s, 3.89±4.77, (223.46±72.54) s, 18.71 ± 13.80, 52.47 ±22.25, 28.82± 16.20, 23.39±9.72, respectively; this was higher than those in the control group [(52.10± 12.18) s, 1.68± 1.97, (134.86±34.15) s, 4.22±4.21, 32.46± 17.97, 14.42±8.47, 18.24± 10.24, P 〈 0.05 - 0.01]. Times of sorting of WCST between internal carotid artery system and vertebral basilar artery system were obviously lower than those in the control group (8.27±2.73, 8.66±2.77, 11.22±2.41, P 〈 0.01). However, there were no significant differences between internal carotid artery system and vertebral basilar artery system (P 〉 0.05). CONCLUSION: Patients with TIA have executive dysfunctions, and the dysfunctions have no difference between internal carotid artery system and vertebral basilar artery system.展开更多
Temperature inferential control (TIC) is studied for a reactive distillation column with double reactive sections (RDC-DRSs) processing a hypothetical two-stage consecutive reversible reaction (A + B■C + D, C + B■E ...Temperature inferential control (TIC) is studied for a reactive distillation column with double reactive sections (RDC-DRSs) processing a hypothetical two-stage consecutive reversible reaction (A + B■C + D, C + B■E + D with αD > αB > αC > αA > αE). Because of the complicated dynamic behaviors, the controlled stages by sensitivity analysis lead to great steady-state deviations (SSDs) in top and bottom product purities. Since TIC involves considerably reduced settling times in comparison with direct composition control, small SSDs in product qualities correspond generally to small transient deviations (TDs) in product qualities. An objective function that measures SSDs in product qualities is formulated to represent the performance of a TIC system and an iterative procedure is devised to search for the best control configuration. The application of the procedure to the RDC-DRS gives considerably suppressed TDs and SSDs in top and bottom product qualities as compared with the one by sensitivity analysis. The method is simpler in principle and less computationally intensive than the current practice. These striking outcomes show the effectiveness of the proposed principle for the development of TIC systems for complicated reactive distillation columns.展开更多
The Program for the Analysis of Reactor Transients/Argonne National Laboratory (PARET/ANL) code was used to predict the thermal hydraulic behaviour of the Ghana Research Reactor-1 after adding 9.0 mm of beryllium to t...The Program for the Analysis of Reactor Transients/Argonne National Laboratory (PARET/ANL) code was used to predict the thermal hydraulic behaviour of the Ghana Research Reactor-1 after adding 9.0 mm of beryllium to the top shim tray of the core. The core was analysed for reactivity insertions 2.1 mk, 3.0 mk, 4.0 mk, 5.0 mk and 6.7 mk, respectively. The reactor is still safe to operate in the range 2.1 mk to 4.0 mk. However, 2.1 mk would be ideal since the reactor automatic shutdown (SCRAM) is set not to exceed 120% of reactor nominal power.展开更多
文摘To address uncertainty as well as transient stability constraints simultaneously in the preventive control of windfarm systems, a novel three-stage optimization strategy is established in this paper. In the first stage, the probabilisticmulti-objective particle swarm optimization based on the point estimate method is employed to cope with thestochastic factors. The transient security region of the system is accurately ensured by the interior point methodin the second stage. Finally, the verification of the final optimal objectives and satisfied constraints are enforcedin the last stage. Furthermore, the proposed strategy is a general framework that can combine other optimizationalgorithms. The proposed methodology is tested on the modified WSCC 9-bus system and the New England 39-bussystem. The results verify the feasibility of the method.
基金support of Aeronautical Science Foundation of China (2011ZB51019)
文摘Transient control law ensures that the aeroengine transits to the command operating state rapidly and reliably. Most of the existing approaches for transient control law design have complicated principle and arithmetic. As a result, those approaches are not convenient for application. This paper proposes an extrapolation approach based on the set-point parameters to construct the transient control law, which has a good practicability. In this approach, the transient main fuel control law for acceleration and deceleration process is designed based on the main fuel flow on steady operating state. In order to analyze the designing feature of the extrapolation approach, the simulation results of several different transient control laws designed by the same approach are compared together. The analysis indicates that the aeroengine has a good performance in the transient process and the designing feature of the extrapolation approach conforms to the elements of the turbofan aeroengine.
基金supported by the National Natural Science Foundation of China(Grant Nos.51005017,51575043&U1564210)
文摘The existing research into hybrid electric vehicle(HEV) control is mainly focussed on the optimisation of the power distribution between a conventional internal combustion engine(ICE) and an alternative power source(usually a battery pack), however,transient control, which is a key technique that affects both fuel economy and the drivability of the HEV, has not been fully addressed. Especially in dual-mode power-split HE Vs, due to the different dynamic characteristics of the actuators in the transmission, and its complicated speed-torque relationship, transient control also affects the precision of power distribution and the speed of response of the electric output power. To improve the transient control performance, the design of an economic model predictive control(EMPC)-based transient controller for a dual-mode power-split HEV is developed. By incorporating an experimental identification model of a diesel ICE in a control-oriented transmission model, a better coordination among the actuators involved in HEV transmission can be achieved. Moreover, an ICE efficiency index is also added to the objective function to improve ICE fuel efficiency during this transient process. Then, a fast MPC method is applied to reduce the on-line computation effort required of the proposed control algorithm. By the flexible application of the EMPC and an innovative ICE model which is suited to the control-oriented model in EMPC, the transient control performance was improved. The effectiveness,and the real-time performance,of the control algorithm are validated by way of MATLABTM/Simulink-based simulations,as well as test-bed experiments combined with the use of the RapidECU platform.
文摘A novel optical transient suppression technique to dramatically reduce gain variation of EDFA with un-cooled pump is demonstrated experimentally, showing excellent performance of 50us transient time with no more than 0.5dB excursion and 0.25dB offset.
文摘Non-alcoholic fatty liver disease(NAFLD) is the most common cause of chronic liver disease worldwide. Currently, the routinely used modalities are unable to adequately determine the levels of steatosis and fibrosis(laboratory tests and ultrasonography) or cannot be applied as a screening procedure(liver biopsy). Among the non-invasive tests, transient elastography(Fibro Scan?, TE) with controlled attenuation parameter(CAP) has demonstrated good accuracy in quantifying the levels of liver steatosis and fibrosis in patients with NAFLD, the factors associated with the diagnosis and NAFLD progression. The method is fast, reliable and reproducible, with good intra- and interobserver levels of agreement, thus allowing for population-wide screening and disease follow-up. The initial inability of the procedure to accurately determine fibrosis and steatosis in obese patients has been addressed with the development of the obese-specific XL probe. TE with CAP is a viable alternative to ultrasonography, both as an initial assessment and during follow-up of patients with NAFLD. Its ability to exclude patients with advanced fibrosis may be used to identify low-risk NAFLD patients in whom liver biopsy is not needed, therefore reducing the risk of complications and the financial costs.
基金This project is supported by National Natural Science Foundation of China(No.59875076).
文摘The simulation model of a valve control hydraulic system with long pipe isestablished in Simulink4.0, and then the step responses of the systems with difference pipeparameters are investigated by simulation. Simulation results show that the long pipes will slowdown the step response of system and make it fluctuate periodically. The results of simulationconform to the results of experiment on the whole, which proves the mathematic model is correct.
文摘We theoretically analyze the transient properties of a probe field absorption and dispersion in a coupled semiconductor double-quantum-dot nanostructure.We show that in the presence of the Gaussian laser beams,absorption and dispersion of the probe field can be dramatically influenced by the relative phase between applied fields and intensity of the Gaussian laser beams.Transient and steady-state behaviors of the probe field absorption and dispersion are discussed to estimate the required switching time.The estimated range is between 5-8 ps for subluminal to superluminal light propagation.
文摘Transient response and its influence factors are investigated and a methodfor attenuating the transient response is developed by means of a time varying model.The system gain matrix is obtained by choosing weighting matrices and solving the timevarying Riccati equation. Control forces are applied to the system via a feed back loop.Comparisons of responses with and without control are made. The results show that thetransienl and steady state responses are significantly suppressed in the close loop systemand control forces are very small.
基金supported by the National Natural Science Foundation of China(Grant No.51307124)the Major Program of the National Natural Science Foundation of China(Grant No.51190105)
文摘A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.
基金The National Natural Science Foundation of China (No.50085002)
文摘By applying a nonlinear control and arranging a transient process, the initiative error of the pneumatic servo positioning system is reduced largely, and a larger gain of the controller is used to improve the responding speed of the system at the same damping ratio. Therefore, a compromise is made among the responding speed, overshoot, robustness, adaptability and stability. In addition, a dynamic output feedback controller, including position velocity and acceleration (PVA) feedback, is designed to improve the performance of the system. And a nonlinear controller is reconstructed based on the linear output feedback controller to decrease noises and disturbances. The dynamic responses of the system are simulated and tested. Results show that the error is kept within 0.02 mm under different mass loads and the positioning transient process is smooth, without overshoot and speedy.
文摘Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized in space by finite center difference approximation, then the nonlinear ordinal differential equations were obtained. A hybrid method involving the combination of the Newmark method and the pseudo-force strategy was proposed to analyze the nonlinear transient response of the inclined cable-dampers system subjected to arbitrary dynamic loading. As an example, two typical stay cables were calculated by the present method. The results reveal both the validity and the deficiency of the viscoelasticity damper for vibration control of stay cables. The efficiency and accuracy of the proposed method is also verified by comparing the results with those obtained by using Runge-Kutta direct integration technique. A new time history analysis method is provided for the research on the stay cable vibration control.
基金Supported by China Hepatitis Prevention and Treatment Foundation Wang Baoen Liver Fibrosis Research Fund,No.xjs20110402
文摘AIM: To study the diagnostic value of controlled attenuation parameter (CAP), evaluated by transient elastography, for liver steatosis in patients with chronic hepatitis B (CHB).
文摘Taking the bending stiffness, static sag, and geometric non-linearity into consideration, the space nonlinear vibration partial differential equations were derived. The partical differential equations were discretized in space by finite center difference approximation, then the nonlinear ordinal differential equations were obtained. A hybrid method involving the combination of the Newmark method and the pseudo-force strategy was proposed to analyze the nonlinear transient response of the inclined cable-dampers system subjected to arbitrary dynamic loading. As an example, two typical stay cables were calculated by the present method. The results reveal both the validity and the deficiency of the viscoelasticity damper for vibration control of stay cables. The efficiency and accuracy of the proposed method is also verified by comparing the results with those obtained by using Runge-Kutta direct integration technique. A new time history analysis method is provided for the research on the stay cable vibration control.
基金Project supported by the Natural Science Foundation of Liaoning Province,China (Grant No. 201102181)
文摘A new approach of generating transient chaos from two-dimensional(2D) continuous autonomous systems within finite time is presented.Based on an absolute-value switching law,the phenomenon of transient chaos takes place by switching between three 2D systems.Basic dynamic behavior of the systems is investigated.Numerical examples illustrate the validity of the results.
基金supported in part by the National Natural Science Foundation of China,Key Project (10532010)the Ministry of Science and Technology of China’s Turbulence Program(2009CB724101)+1 种基金the National Basic Research Program of China(2007CB714600)the Foundation for Innovative Research Groups of the National Natural Science Foundation of China(10921202/A0204)
文摘By Green's function method we show that the water hammer (WH) can be analytically predicted for both laminar and turbulent flows (for the latter, with an eddy vis- cosity depending solely on the space coordinates), and thus its hazardous effect can be rationally controlled and mini- mized. To this end, we generalize a laminar water hammer equation of Wang et al. (J. Hydrodynamics, B2, 51, 1995) to include arbitrary initial condition and variable viscosity, and obtain its solution by Green's function method. The pre- dicted characteristic WH behaviors by the solutions are in excellent agreement with both direct numerical simulation of the original governing equations and, by adjusting the eddy viscosity coefficient, experimentally measured turbulent flow data. Optimal WH control principle is thereby constructed and demonstrated.
基金High-educational Talents Starting Foundation of Xinxiang Medical College
文摘BACKGROUND: Recent researches demonstrate that damage of executive function is an early manifestation of vascular cognitive disorder. OBJECTIVE: To investigate the executive functions of patients with transient ischemic attack (TIA). DESIGN: Case control. SETTING: Department of Neurology, the First Affiliated Hospital of Xinxiang Medical College. PARTICIPANTS: A total of 83 TIA patients (46 males and 37 females, aged 32 - 74 years) were selected from Department of Neurology, the First Affiliated Hospital of Xinxiang Medical College from July 2005 to December 2006. The diagnosis of TIA was established by the criteria of cerebrovascular diseases made by the Fourth National Cerebrovascular Disease Meeting. In these cases, forty-five patients (54%) were involved in internal carotid artery, and thirty-eight patients (46%) were involved in vertebral basilar system. Fifty healthy adults (Control group: 28 males and 22 females, aged 32 - 74 years) were chosen from retiree in community and family of patients. All of them were right-handedness, without cerebrovascular disease, cerebral trauma, inborn oligophrenia, and heating and visual disorders; also they had no anxiety and depression nearly one week. In addition, all the subjects cooperated with examination. METHODS: After TIA diagnosis, all patients received neuropsychological examination, including attention and inhibition, working memory, flexibility, planning and diversion, based on Stroop tests (C and CW) and the Wisconsin card sorting tests (WCST). ① WCST test: The edition revised by Nelson was used. We would take the times of sorting, incorrect response, persistent incorrect response, and randomly incorrect response as the index of evaluation.② Stroop tests: The edition revised by Trenarry was used and this test had two types: form color and form color-word. Their incorrect response and response time were recorded for data analysis in the end. MAIN OUTCOME MEASURES: Results of WCST test and Stroop tests. RESULTS: A total of 83 TIA patients and 50 healthy subjects were involved in the final analysis. Items of Stroop tests, including response time of Stroop-C test, incorrect response of Stroop-C test, response time of Stroop-CW test and incorrect response of Stroop-CW test, and items of WCST, including incorrect response, persistent incorrect response and random incorrect response, between internal carotid artery system and vertebral basilar artery system were (93.87±24.39) s, 3.16±3.97, (228.46±68.13) s, 12.91 ± 10.56, 55.42± 20.38, 26.58± 10.41, 28.62±11.22; (96.76±24.75) s, 3.89±4.77, (223.46±72.54) s, 18.71 ± 13.80, 52.47 ±22.25, 28.82± 16.20, 23.39±9.72, respectively; this was higher than those in the control group [(52.10± 12.18) s, 1.68± 1.97, (134.86±34.15) s, 4.22±4.21, 32.46± 17.97, 14.42±8.47, 18.24± 10.24, P 〈 0.05 - 0.01]. Times of sorting of WCST between internal carotid artery system and vertebral basilar artery system were obviously lower than those in the control group (8.27±2.73, 8.66±2.77, 11.22±2.41, P 〈 0.01). However, there were no significant differences between internal carotid artery system and vertebral basilar artery system (P 〉 0.05). CONCLUSION: Patients with TIA have executive dysfunctions, and the dysfunctions have no difference between internal carotid artery system and vertebral basilar artery system.
基金Supported by the National Natural Science Foundation of China(21376018,21576014,21676011,21808007,and 21878011)the Fundamental Research Funds for the Central Universities(ZY1837)China Postdoctoral Science Foundation(2017M620587)
文摘Temperature inferential control (TIC) is studied for a reactive distillation column with double reactive sections (RDC-DRSs) processing a hypothetical two-stage consecutive reversible reaction (A + B■C + D, C + B■E + D with αD > αB > αC > αA > αE). Because of the complicated dynamic behaviors, the controlled stages by sensitivity analysis lead to great steady-state deviations (SSDs) in top and bottom product purities. Since TIC involves considerably reduced settling times in comparison with direct composition control, small SSDs in product qualities correspond generally to small transient deviations (TDs) in product qualities. An objective function that measures SSDs in product qualities is formulated to represent the performance of a TIC system and an iterative procedure is devised to search for the best control configuration. The application of the procedure to the RDC-DRS gives considerably suppressed TDs and SSDs in top and bottom product qualities as compared with the one by sensitivity analysis. The method is simpler in principle and less computationally intensive than the current practice. These striking outcomes show the effectiveness of the proposed principle for the development of TIC systems for complicated reactive distillation columns.
文摘The Program for the Analysis of Reactor Transients/Argonne National Laboratory (PARET/ANL) code was used to predict the thermal hydraulic behaviour of the Ghana Research Reactor-1 after adding 9.0 mm of beryllium to the top shim tray of the core. The core was analysed for reactivity insertions 2.1 mk, 3.0 mk, 4.0 mk, 5.0 mk and 6.7 mk, respectively. The reactor is still safe to operate in the range 2.1 mk to 4.0 mk. However, 2.1 mk would be ideal since the reactor automatic shutdown (SCRAM) is set not to exceed 120% of reactor nominal power.