期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Discharge Characteristics of Long SF6 Gas Gap with and Without Insulator in GIS Under VFTO and LI 被引量:17
1
作者 Tao Wen Qiaogen Zhang +6 位作者 Jingtan Ma Can Guo Haoyang You Yifan Qin Yu Yin Weidong Shi Weijiang Chen 《CSEE Journal of Power and Energy Systems》 SCIE 2015年第3期16-22,共7页
Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient over... Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient overvoltage(VFTO)increases caused by a rise in voltage levels can lead to GIS insulation failures.In this paper,a generating system of VFTO and standard lightning impulse(LI)is established.The insulation characteristics of SF6 gas with and without insulators under VFTO and standard LI are investigated.Experimental results show that the 50%breakdown voltages of the inhomogeneous electric field rod-plane gap under positive VFTO and standard LI are higher than that under negative VFTO and standard LI.The research shows that the 50%breakdown voltage under VFTO could be lower than that under standard LI at 0.5 MPa for the negative polarity.Moreover,the polarity effect of the insulator without defect is different from that with defect.Similarly,the breakdown voltage of the defective insulator under VFTO could be lower than that under standard LI by 8%.The flashover channel under VFTO is seen as more than that under standard LI.Based on the analysis of discharge images and experimental results,it is concluded that the polarity effect is related to the distortion effect of ion clusters formed by SF6 on the electric field.Additionally,the steepness and front time of impulse plays an important role in the initiation and further development of discharge on insulator surface.Finally,the research shows that different discharge characteristics between VFTO and standard LI may be caused by different wave fronts and oscillation on the tails of the impulses. 展开更多
关键词 Breakdown voltage discharge characteristic gas insulated switchgear(GIS) lightning impulse(LI) space charge very fast transient overvoltage(VFTO)
原文传递
High-voltage Ride Through Strategy for DFIG Considering Converter Blocking of HVDC System 被引量:11
2
作者 Changping Zhou Zhen Wang +1 位作者 Ping Ju Deqiang Gan 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第3期491-498,共8页
This paper presents a P-Q coordination based highvoltage ride through(HVRT) control strategy for doubly fed induction generators(DFIGs) based on a combined Q-V control and P-V de-loading control. The active/reactive p... This paper presents a P-Q coordination based highvoltage ride through(HVRT) control strategy for doubly fed induction generators(DFIGs) based on a combined Q-V control and P-V de-loading control. The active/reactive power injection effect of DFIG on transient overvoltage is firstly analyzed and the reactive power capacity evaluation of DFIG considering its de-loading operation is then conducted. In the proposed strategy, the reactive power limit of DFIG can be flexibly extended during the transient process in coordination with its active power adjustment. As a result, the transient overvoltage caused by DC bipolar block can be effectively suppressed. Moreover, key outer loop parameters such as Q-V control coefficient and deloading coefficient can be determined based on the voltage level of point of common coupling(PCC) and the available power capacity of DFIG. Finally, case studies based on MATLAB/Simulink simulation are used to verify the effectiveness of the proposed control strategy. 展开更多
关键词 Active power de-loading control high-voltage ride through(HVRT) inductive power absorption transient overvoltage
原文传递
Impact of Synchronous Condenser on the Dynamic Behavior of LCC-based UHVDC System Hierarchically Connected to AC System 被引量:9
3
作者 Ali Aamir Li Qiao +2 位作者 Chunyi Guo Atiq Ur Rehman Zhizhong Yang 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2019年第2期190-198,共9页
Hierarchical connection(HC)is a very attractive mode for±800 kV line commutated converter based ultra high voltage direct current(LCC-UHVDC)system connected to different AC voltage levels because of its ability t... Hierarchical connection(HC)is a very attractive mode for±800 kV line commutated converter based ultra high voltage direct current(LCC-UHVDC)system connected to different AC voltage levels because of its ability to reduce the scale factor of a converter transformer.Faults in the HC-UHVDC system can cause commutation failure(CF).In this paper,impact of synchronous condenser(SC)to mitigate CF in HC-UHVDC system is analyzed.A±800KV HC-UHVDC system along with synchronous condenser is built in PSCAD/EMTDC.Transient performance analysis of HC-UHVDC for single and three phase to ground faults is investigated.Commutation failure immunity index(CFII),commutation failure probability index(CFPI),fault recovery time(FRT),and transient overvoltage(TOV)are used as measures to evaluate the effects of SC at HC-UHVDC system design.The simulation results show that SC can make the HCUHVDC system less susceptible to CF,effectively improve fault recovery performances of the overall system,and reduce transient overvoltage when single or multiple converters are blocked.The results of this research can provide technical assistance in real world HC-UHVDC projects. 展开更多
关键词 Commutation failure hierarchical connection synchronous condenser transient overvoltage ultra-high voltage direct current
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部