期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
An Evaluation of Inter-Fractional Set-Up Errors in Patients Treated with Distinct Immobilization Equipment for Varying Anatomical Regions
1
作者 Sibel Karaca Hamit Başaran +1 位作者 Timur Koca Ferhat Özbayrak 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第2期121-129,共9页
This study aims to evaluate inter-fractional set-up errors in patients treated with distinct immobilization equipment (thermoplastic mask, knee-fix and feet-fix, wing board and vac-lok) for four anatomical regions inc... This study aims to evaluate inter-fractional set-up errors in patients treated with distinct immobilization equipment (thermoplastic mask, knee-fix and feet-fix, wing board and vac-lok) for four anatomical regions including brain, head and neck (HN), thorax and pelvis. Data of randomly selected 140 patients who were treated for four anatomical regions were obtained using Hi-Art Helical Tomotherapy (HT) system. Pre-treatment planning was based on automatic registration readings of computed tomography (CT) and mega-voltage computed tomography (MVCT) on a daily basis. Distinct immobilization equipment was used for varying anatomical regions. Individual mean set-up error (M), systematic error (Σ), and random error (σ) values were calculated through daily translational and rotational deviation values. The size of translational, systematic and random error was 1.31 - 4.93 mm for brain, 2.28 - 4.88 mm for HN, 4.04 - 9.90 mm for thorax, and 6.34 - 14.68 mm for pelvis. Rotational values were as follows: 0.06&deg - 0.73&deg for brain, 0.42&deg - 0.6&deg for HN, 0.48&deg - 1.14&deg for thorax and 0.65&deg - 1.05&deg for pelvis. The highest translational, systematic and random error value was obtained from the pelvic regional. The highest standard and random error value in pitch and roll was produced in the rotational direction of the pelvis (0.05° and 0.71°), while the highest error value in yaw was (1.14°) produced from thorax. Inter-fractional set-up errors were most commonly produced in the pelvis, followed by thorax. Our study results suggest that the highest systematic and random errors are found for thorax and pelvis. Distinct immobilization equipment was important in these results. Safety margins around the clinical target volume (CTV) are changeable for different anatomical regions. A future work could be developed to new equipment for immobilization because of the reduced margins CTV. 展开更多
关键词 Hi-Art Helical Tomotherapy IGRT Inter-Fractional Set-Up Errors Rotational Variation translational Variation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部