期刊文献+
共找到250篇文章
< 1 2 13 >
每页显示 20 50 100
Rigorous theoretical derivation of lumped models to transmission line systems
1
作者 赵吉祥 《Journal of Semiconductors》 EI CAS CSCD 2012年第3期94-100,共7页
By virtue of the negative electric parameter concept,i.e.negative lumped resistance,inductance,conductance and capacitance(N-RLGC),the lumped equivalent models of transmission line systems,including the circuit mode... By virtue of the negative electric parameter concept,i.e.negative lumped resistance,inductance,conductance and capacitance(N-RLGC),the lumped equivalent models of transmission line systems,including the circuit model,two-portπ-network and T-network,are given.We start from the N-segment-ladder-like equivalent networks composed distributed parameters,and achieve the input impedance in the form of a continued fraction. Utilizing the continued fraction theory,the expressions of input impedance are obtained under three kinds of extreme cases,i.e.the load impedances are equal to zero,infinity and characteristic impedance,respectively.When the number of segment N is limited to infinity,they are transformed to lumped elements.Comparison between the distributed model and lumped model of transmission lines,the expression of tanh yd,which is the key term in the transmission line equations,are obtained by RLGC,furthermore,according to input admittance,admittance matrix and ABCD matrix of transmission lines,the lumped equivalent circuit models,π-networks and T-networks have been given.The models are verified in the frequency and time domain,respectively,showing that the models are accurate and efficient. 展开更多
关键词 lumped models transmission line systems negative electric parameters concept
原文传递
Research on Total Electric Field Prediction Method of Ultra-High Voltage Direct Current Transmission Line Based on Stacking Algorithm
2
作者 Yinkong Wei Mucong Wu +3 位作者 Wei Wei Paulo R.F.Rocha Ziyi Cheng Weifang Yao 《Computer Systems Science & Engineering》 2024年第3期723-738,共16页
Ultra-high voltage(UHV)transmission lines are an important part of China’s power grid and are often surrounded by a complex electromagnetic environment.The ground total electric field is considered a main electromagn... Ultra-high voltage(UHV)transmission lines are an important part of China’s power grid and are often surrounded by a complex electromagnetic environment.The ground total electric field is considered a main electromagnetic environment indicator of UHV transmission lines and is currently employed for reliable long-term operation of the power grid.Yet,the accurate prediction of the ground total electric field remains a technical challenge.In this work,we collected the total electric field data from the Ningdong-Zhejiang±800 kV UHVDC transmission project,as of the Ling Shao line,and perform an outlier analysis of the total electric field data.We show that the Local Outlier Factor(LOF)elimination algorithm has a small average difference and overcomes the performance of Density-Based Spatial Clustering of Applications with Noise(DBSCAN)and Isolated Forest elimination algorithms.Moreover,the Stacking algorithm has been found to have superior prediction accuracy than a variety of similar prediction algorithms,including the traditional finite element.The low prediction error of the Stacking algorithm highlights the superior ability to accurately forecast the ground total electric field of UHVDC transmission lines. 展开更多
关键词 DC transmission line total electric field effective data multivariable outliers LOF algorithm Stacking algorithm
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
3
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
Real-Time Wind Speed Analysis at Wind-Damaged Tower of a Transmission Line
4
作者 Jiehua Ding Xiaoling Yang Yongsheng Zhao 《Journal of Electronic Research and Application》 2024年第6期58-65,共8页
Affected by the Super Typhoon“Mangkhut,”a total of five base towers of a transmission line in the mountainous area of China collapsed.In this paper,a mathematical model is established based on the Shuttle Radar Topo... Affected by the Super Typhoon“Mangkhut,”a total of five base towers of a transmission line in the mountainous area of China collapsed.In this paper,a mathematical model is established based on the Shuttle Radar Topography Mission(SRTM)data near the accident tower.The measured wind speed in the plain area under the mountain is used as the calculation boundary condition.The wind speed at the top of the mountain is calculated by using a numerical simulation method.The design wind speed and calculated wind speed at the tower site are compared,and the influence of wind speed on tower position in this wind disaster accident is analyzed. 展开更多
关键词 Power transmission line Wind disaster Design wind speed Real-time wind speed Numerical simulation
下载PDF
Effects of Un-transposed UHV Transmission Line on Fault Analysis of Power Systems
5
作者 王安宁 陈青 周占平 《Transactions of Tianjin University》 EI CAS 2008年第3期231-234,共4页
The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with... The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with the symmetrical distributed parameter circuit model as the equivalent circuit of the un-transposed ultra high voltage(UHV) transmission line were studied under both normal operation and fault,and the corresponding problems arising were pointed out. By contrast with electromagnetic transient and power electronics(EMTPE) simulation results with the asymmetrical distributed parameter circuit model of un-transposed line, it is shown that the conventional method cannot show the existence of negative and zero sequences before fault happening and there are many errors on voltage and current after fault happening which are different with fault types. The error ranges of voltage and current are 2.13%-81.13% and -7.82%- -86.15%, respectively. 展开更多
关键词 EMTPE fault calculation SIMULATION un-transposed UHV transmission line
下载PDF
Design of the Transmission Lines for 140 GHz ECRH System on HL-2A
6
作者 夏冬辉 周俊 +7 位作者 饶军 黄梅 陆志鸿 王贺 陈罡宇 王超 卢波 庄革 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第3期267-272,共6页
A new 140 GHz/2 MW/3 s electron cyclotron resonance heating (ECRH) system composed of two units is now being constructed on HL-2A. As a part of the system, two trans- mission lines marked No.7 & 8 play the role of ... A new 140 GHz/2 MW/3 s electron cyclotron resonance heating (ECRH) system composed of two units is now being constructed on HL-2A. As a part of the system, two trans- mission lines marked No.7 & 8 play the role of carrying microwave power from two gyrotrons to the tokamak port. Based on the oversized circular corrugated waveguide technology, an evacu~ ated transmission system with high power capability and high transmission efficiency is designed. Details are presented for the design of the corrugated waveguide, the layout of the proposed lines and the vacuum pumping system. Then mode conversion losses due to coupling, misalignment, bends and gaps are discussed to serve as a reference for analyzing the transmission efficiency and alignment. Finally, a dual-modes propagation case consisting of the HEll and LPn even modes is discussed. 展开更多
关键词 HL-2A tokamak electron cyclotron resonance heating transmission line
下载PDF
Application HELAVA Digital Photogrammetry System in Extra High Voltage Transmission Line Path Optimization
7
《Electricity》 1999年第1期45-48,共4页
关键词 PATH Application HELAVA Digital Photogrammetry system in Extra High Voltage transmission line Path Optimization FIGURE
下载PDF
The Integrated System of Aerial Photogrammetry and Tower Locations Optimization for Transmission Lines
8
作者 Xie Yuan, Pan Yijun, Fu Bin Northwest Power Design Institute 《Electricity》 1996年第4期45-48,共4页
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission... This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system. 展开更多
关键词 PRO The Integrated system of Aerial Photogrammetry and Tower Locations Optimization for transmission lines
下载PDF
Equivalent for Electromagnetic Transient Calculation in Power System with Multiple Transmission Line
9
作者 Pawel Sowa Katarzyna Luszcz 《Energy and Power Engineering》 2013年第4期1449-1455,共7页
The results of searching of equivalent for electromagnetic transient calculation in power system with the big number of transmission lines are shown. Brief information on the proper transmission line model is given. C... The results of searching of equivalent for electromagnetic transient calculation in power system with the big number of transmission lines are shown. Brief information on the proper transmission line model is given. Comparison of results of simulation in real and reduced system is presented taking into consideration three methods of identification. Some example are examined for different number of transmission lines in reduced system and consequently the recommendation are given for searching of equivalents of systems with many lines. 展开更多
关键词 Electromagnetic Transients EQUIVALENTS transmission line Representation
下载PDF
The Effective Enhancement of Power System Security by Flexible Transmission Line Impedance with Minimal Rescheduling of Generators
10
作者 Karuppasamy Muthulakshmi R.M. Sasiraja Selvarajan Mukesh Muthu 《Circuits and Systems》 2016年第4期381-389,共9页
After the digital revolution, the power system security becomes an important issue and it urges the power producers to maintain a well secured system in order to supply a quality power to the end users. This paper pre... After the digital revolution, the power system security becomes an important issue and it urges the power producers to maintain a well secured system in order to supply a quality power to the end users. This paper presents an integrated Corrective Security Constrained Optimal Power Flow (CSCOPF) with Flexible Transmission Line Impedance (FTLI) to enhance the power system security. The corrective approach of SCOPF is chosen, because it allows the corrective equipment to bring back the system to a stable operating point and hence, it offers high flexibility and better economics. The concept of FTLI arises from the ability of FACTS devices such as Thyristor Controlled Series Capacitor (TCSC), which can vary the line reactance to a certain extent. An enhanced security can be achieved by incorporating FTLI into the CSCOPF problem, since the power flow in a system is highly dependent on the line reactance. FTLI based CSCOPF can reduce the amount of rescheduling of generators, but it will result in an increased number of variables and thus, the complexity to the optimization process is increased. This highly complex problem is solved by using nonlinear programming. The AC based OPF model is preferred, since the corrective security actions require highly accurate solutions. IEEE 30 bus system is used to test the proposed scheme and the results are compared with the traditional CSCOPF. It can be seen that the proposed idea provides a notable improvement in the reduction of cost incurred for restoring the system security. 展开更多
关键词 Flexible transmission line Impedance Power system Security Security Constrained Optimal
下载PDF
NEW PRINCIPLE FOR DIRECTIONAL COMPARISON CARRIER PROTECTION OF EHV TRANSMISSION LINES 被引量:1
11
作者 王钢 李遥 +2 位作者 余晓丹 刘众仆 贺家李 《Transactions of Tianjin University》 EI CAS 1998年第2期6-10,共5页
The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave ch... The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave channels is the most suitable protection scheme for long distance EHV transmission lines and is widely used in power systems.The key element of such protection is a directional relay used to discriminate the fault direction.In order to overcome the disadvantages of conventional directional relays,the authors of this paper put forward the directional comparison carrier protection based on the artificial neural network(ANN).The protection is extensively tested using electromagnetic transient program (EMTP) under various electric power system operating and fault conditions.It is proved that the directional comparison carrier protection based on ANN,which can recognize various fault patterns of the protected transmission line(such as fault direction,fault phases etc.)correctly in any kind of operating and fault conditions and the whole process,is satisfactory for EHV transmission line protection. 展开更多
关键词 artificial neural network EHV transmission line directional comparison carrier protection
下载PDF
Nonlinear dynamical response of high-voltage transmission lines based on cable dropping 被引量:1
12
作者 夏开全 刘云 钱振东 《Journal of Southeast University(English Edition)》 EI CAS 2009年第1期52-56,共5页
In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilib... In order to study the dynamic response of high-voltage transmission lines under mechanical failure, a finite element model of a domestic 500-kV high-voltage transmission line system is established. The initial equilibrium condition of the coupling system model is verified by nonlinear static analysis. The transient dynamic analysis method is proposed to analyze the variation law of dynamic response under cable or insulator rupture, and the dynamic response of structural elements next to the broken span is calculated. The results show that upper crossarm cable rupture has no effect on cable tension at adjacent suspension points, but it has a significant influence on tension in the insulator and the tower component of the upper crossarm next to the broken span. The peak tension in the conductor of the upper crossarm at the suspension point exceeds the design value under insulator rupture. Insulator rupture has no effect on the tower component of the upper crossarm, but it has a significant influence on insulator tension of the upper crossarm. Insulator rupture should be taken into account in the design of overhead transmission lines. The research results can provide a theoretical basis for the design of transmission lines. 展开更多
关键词 high-voltage transmission line transient response cable dropping numerical simulation finite element method
下载PDF
Tests on the First 500 kV Compact Transmission Line in China 被引量:2
13
作者 巩学海 王惠仁 张章奎 《Electricity》 2001年第1期22-27,共6页
The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investi... The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investigate the characteristics of the transmission line, many tests were performed on the line before and after its operation. The results indicate that all electrical parameters are perfectly identical to the design. 展开更多
关键词 compact transmission line overvoltage switching surge parameters
下载PDF
Mechanical analysis of transmission lines based on linear sliding cable element
14
作者 刘云 钱振东 夏开全 《Journal of Southeast University(English Edition)》 EI CAS 2013年第4期436-440,共5页
In order to study the sliding characteristics when the cable structures are connected with other rods, a string of sliding cable dements (SCE) consisting of one active threenode SCE passing through the sliding point... In order to study the sliding characteristics when the cable structures are connected with other rods, a string of sliding cable dements (SCE) consisting of one active threenode SCE passing through the sliding point and multiple inactive two-node SCEs is put forward. Based on the updated Lagrangian formulation, the geometric nonlinear stiffness matrix of the three-node straight sliding cable dement is deduced. The examples about two-span and three-span continuous cable structures are studied to verify the effectiveness of the derived SCE. Comparing the cable tension of SCE with the existing research results, the calculating results show that the error is less than 1%. The sliding characteristics should be considered in practical engineering because of the obvious difference between the cable tension of the SCE and that of the cable element without considering sliding characteristics. 展开更多
关键词 transmission line sliding cable element updated Lagrangian formulation geometric nonlinear
下载PDF
CHARACTERISTICS ANALYSIS OF THE INDUCED OVERCURRENT GENERATED BY CLOSE TRIGGERED LIGHTNING ON THE OVERHEAD TRANSMISSION POWER LINE 被引量:8
15
作者 杨少杰 陈绍东 +5 位作者 张义军 董万胜 王建国 周蜜 王孝波 余晖 《Journal of Tropical Meteorology》 SCIE 2010年第1期59-65,共7页
Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightni... Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightning electromagnetic pulses.In this study,using capacitive and resistive dividers,current probes and optical fiber transmission devices,we measured and analyzed the induced overvoltage on the overhead transmission line and the overcurrent through Surge Protective Devices(SPD) when a lightning discharge was artificially triggered nearby on August 12,2008 at Conghua Field Lightning Experiment Site.The triggered lightning discharge contained an initial current stage and eight return strokes whose peak currents ranged from 6.6kA to 26.4kA.We found that overcurrents through SPD were induced on the power line both during the initial continuous current stage and the return stroke processes.During the return strokes,the residual voltage and the current through the SPD lasted up to the ms(millisecond) range,and the overcurrents exhibited a mean waveform up to 22/69μs with a peak value of less than 2kA.Based on the observed data,simple calculations show that the corresponding single discharge energy was much greater than the values of the high voltage pulse generators commonly used in the experiments regulated for SPD.The SPD discharge current peak was not synchronous to that of the residual voltage with the former obviously lagging behind the latter.The SPD discharge current peak was well correlated with the triggered lightning current peak and the wave-front current gradient.The long duration of the SPD current is one of the major reasons why the SPD was damaged even with a big nominal discharge current. 展开更多
关键词 triggered lightning overhead transmission line SPD induced overcurrent
下载PDF
Transmission line fault-cause identification method for large-scale new energy grid connection scenarios 被引量:7
16
作者 Hanqing Liang Xiaonan Han +3 位作者 Haoyang Yu Fan Li Zhongjian Liu Kexin Zhang 《Global Energy Interconnection》 EI CAS CSCD 2022年第4期362-374,共13页
The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty line... The accurate fault-cause identification for overhead transmission lines supports the operation and maintenance personnel in formulating targeted maintenance strategies and shortening the time of inspecting faulty lines.With the goal of achieving“carbon peak and carbon neutrality”,the schemes for clean energy generation have rapidly developed.Moreover,new energy-consuming equipment has been widely connected to the power grid,and the operating characteristics of the power system have significantly changed.Consequently,these have impacted traditional fault identification methods.Based on the time-frequency characteristics of the fault waveform,new energy-related parameters,and deep learning model,this study proposes a fault identification method suitable for scenarios where a high proportion of new energy is connected to the power grid.Ten parameters related to the causes of transmission line fault and new energy connection scenarios are selected as model characteristic parameters.Further,a fault identification model based on adaptive deep belief networks was constructed,and its effect was verified by field data. 展开更多
关键词 Fault-cause identification transmission lines Fault waveform Large-scale new energy Fault cause
下载PDF
Impacts of flexible obstructive working environment on dynamic performances of inspection robot for power transmission line 被引量:6
17
作者 肖晓晖 吴功平 +1 位作者 杜娥 李三平 《Journal of Central South University of Technology》 2008年第6期869-876,共8页
The rigid-flexible coupling dynamic modeling and simulation of an inspection robot were conducted to study the influences of the flexible obstructive working environment i.e. overhead transmission line on the robot's... The rigid-flexible coupling dynamic modeling and simulation of an inspection robot were conducted to study the influences of the flexible obstructive working environment i.e. overhead transmission line on the robot's dynamic performance. First, considering the structure of the obstacles and symmetrical mechanism of the robot prototype, four basic subactions were abstracted to fulfill full-path kinematic tasks. Then, a multi-rigid-body dynamic model of the robot was built with Lagrange equation, whil^e a multi-flexible-body dynamic model of a span of lin~ was obtained by combining finite element method (FEM), modal synthesis method and Lagrange equation. The two subsystem models were coupled under rolling along no-obstacle segment and overcoming obstacle poses, and these simulations of three subactions along different spans of line were performed in ADMAS. The simulation results, including the coupling vibration parameters and driving moment of joint motors, show the dynamic performances of the robot along ftexibile obstructive working path: in flexible obstructive working environment, the robot can fulfill the preset motion goals; it responses slower in more flexible path; the fluctuation of robot as well as driving moment of the corresponding joint in startup and brake region is greater than that in rigid environment; the fluctuation amplitude increases with increasing working environment flexibility. 展开更多
关键词 inspection robot transmission line OBSTRUCTION rigid-flexible coupling dynamics finite element method simulation
下载PDF
High Precision Ultrasonic Guided Wave Technique for Inspection of Power Transmission Line 被引量:4
18
作者 CHENG Jun QIU Jinhao +3 位作者 JI Hongli WANG Enrong TAKAGI Toshiyuki UCHIMOTO Tetsuya 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第1期170-179,共10页
Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave pr... Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line. 展开更多
关键词 ultrasonic guided wave inspection power transmission line piezoelectric transducer defect positioning wavelet transform
下载PDF
Mechanical response of transmission lines based on sliding cable element 被引量:4
19
作者 刘云 钱振东 夏开全 《Journal of Central South University》 SCIE EI CAS 2014年第8期3370-3377,共8页
In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding ca... In order to study the sliding characteristics when the cable is connected with the other rods in the transmission line structures,a linear sliding cable element based on updated Lagrangian formulation and a sliding catenary element considering the out-of-plane stiffness coefficient are put forward.A two-span and a three-span cable structures are taken as examples to verify the sliding cable elements.By comparing the tensions of the two proposed cable elements with the existing research results,the error is less than 1%,which proves the correctness of the proposed elements.The sliding characteristics should be considered in the practical engineering because of the significant difference between the tensions of sliding cable elements and those of cable element without considering sliding.The out-of-plane stiffness coefficient and friction characteristics do not obviously affect the cable tensions. 展开更多
关键词 transmission lines sliding cable element updated Lagrangian formulation geometric nonlinearity mechanical response
下载PDF
Time-domain analytic solutions of two-wire transmission line excited by a plane-wave field 被引量:4
20
作者 倪谷炎 颜力 袁乃昌 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第10期3629-3634,共6页
This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT)... This paper reports that an analytic method is used to calculate the load responses of the two-wire transmission line excited by a plane-wave directly in the time domain. By the frequency-domain Baum Liu-Tesehe (BLT) equation, the time-domain analytic solutions are obtained and expressed in an infinite geometric series. Moreover, it is shown that there exist only finite nonzero terms in the infinite geometric series if the time variate is at a finite interval. In other word, the time-domain analytic solutions are expanded in a finite geometric series indeed if the time variate is at a finite interval. The computed results are subsequently compared with transient responses obtained by using the frequency-domain BLT equation via a fast Fourier transform, and the agreement is excellent. 展开更多
关键词 transmission line analytic solution BLT equation coupling formulation.
下载PDF
上一页 1 2 13 下一页 到第
使用帮助 返回顶部