Based on the transmission line code TLCODE, a 1D circuit model for a transmission- line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to ...Based on the transmission line code TLCODE, a 1D circuit model for a transmission- line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy- transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Г (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Г, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%.展开更多
The conformal transformation solution is presented for the attenuation constant ofTEM transmission lines which can be mapped into the coaxial or the parallel plate lines by certainconformal transformations including t...The conformal transformation solution is presented for the attenuation constant ofTEM transmission lines which can be mapped into the coaxial or the parallel plate lines by certainconformal transformations including the numerical ones.The analytic and numerical results ofsome examples are also given.展开更多
A new approach, based on the waveform relaxation technique and fast Walsh trans-form, is presented to analyze the coupled loosy transmission lines (CLTL) with arbitrary terminalnetworks. The simulation accuracy of the...A new approach, based on the waveform relaxation technique and fast Walsh trans-form, is presented to analyze the coupled loosy transmission lines (CLTL) with arbitrary terminalnetworks. The simulation accuracy of the new method can be greatly improved, the disadvantagewhich always exists in previous methods can be avoided and a considerable saving in time andmemory of CPU is obtained.展开更多
This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various fa...This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance.展开更多
Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home a...Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home and abroad were introduced.Moreover,the problems existing in the on-line monitoring of electromagnetic environment were expounded,and the development prospect was forecasted.展开更多
Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave pr...Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.展开更多
Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a h...Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a higher impedance profile of the internal transmission line would lead to a wider adjustment range for the output current rise time and a narrower adjustment range for the current peak. The number of cavities in series has a positive effect on the output- pulse shaping capability of LTD. Such an improvement in the output-pulse shaping capability can primarily be ascribed to the increment in the axial electric length of LTD. For a triggering time interval longer than the time taken by a pulse to propagate through the length of one cavity, the output parameters of LTD could be improved significantly. The present insulating capability of gas switches and other elements in the LTD cavities may only tolerate a slightly longer deviation in the triggering time interval. It is feasible for the LTD module to reduce the output current rise time, though it is not useful to improve the peak power effectively.展开更多
A whole circuit model of a linear transformer drivers (LTD) module composed of 60 cavities in series was developed in the software PSPICE to study the influence of switching jitter on the operational performances of...A whole circuit model of a linear transformer drivers (LTD) module composed of 60 cavities in series was developed in the software PSPICE to study the influence of switching jitter on the operational performances of LTDs. In the model, each brick in each cavity is capable of operating with jitter in its switch. Additionally, the manner of triggering cables entering into cavities was considered. The performances of the LTD module operating with three typical cavity-triggering sequences were simulated and the simulation results indicate that switching jitter affects slightly the peak and starting time of the output current pulse. However, the enhancement in switching jitter would significantly lengthen the rise time of the output current pulse. Without considering other factors, a jitter lower than 10 ns may be necessary for the switches in the LTD module to provide output current parameters with an acceptable deviation.展开更多
A new method of measuring the icing thickness of transmission lines on-line is proposed in this paper.In this method,the pictures of transmission lines which are photoed by the camera on the iron tower are processed i...A new method of measuring the icing thickness of transmission lines on-line is proposed in this paper.In this method,the pictures of transmission lines which are photoed by the camera on the iron tower are processed immediately to extract the edges of the transmission line conductor and transmission line insulators.The icing thickness can be gained by comparing the edges of the iced transmission line and the uniced one.Two icing image edge extraction methods are described in detail,that is,a method based on the combination of the wavelet transform and the floating threshold method and a method based on the combination of the optimal threshold method and the mathematical morphology transform.The icing images from the artificial climatic chamber and transmission lines are used to test the methods above.The results show that the method based on the wavelet transform and the floating threshold method does well in the extraction of relatively smooth edges,such as glaze icing on conductor and icing on the insulator;meanwhile,the method based on the optimal threshold method and the mathematical morphology transform does well in the edge extraction of icing on the conductor,especially the opaque rime icing on the conductor with complicated edges.展开更多
The objective of this paper is to show an alternative model of a non-transposed three-phase transmission line with a vertical symmetry plane in phase domain. Due the line physical characteristics, it can be represente...The objective of this paper is to show an alternative model of a non-transposed three-phase transmission line with a vertical symmetry plane in phase domain. Due the line physical characteristics, it can be represented by a system consisting of a single?phase and a two-phase line. In this system, the equations describing the behavior of the values in single-phase line terminals are known, while the equations for two-phase line to be obtained. Using a transformation matrix written explicitly according to three-phase line parameters, it is possible to obtain the currents and voltages in phase domain of two-phase line. Then, modal values of three-phase line are converted into phase domain and thus obtain the analytical model for this line. To verify the performance of this model, it was used to simulate the energization of a 440 kV three-phase line and the results were compared to results obtained using a classical model.展开更多
Through the reliability analysis on transmission and transformation facilities with 220 kV or above voltage level in China in 2010, particularly by investigating the planned and unplanned outage of transformers, circu...Through the reliability analysis on transmission and transformation facilities with 220 kV or above voltage level in China in 2010, particularly by investigating the planned and unplanned outage of transformers, circuit breakers and overhead transmission lines with 220 kV, 330 kV and 500 kV level, the weak parts that may influence the operational reliabilities are figured out from technical and liability causes. Moreover, through the research on the device models and comparison of performance indices between domestic and imported devices, the trend of the reliability changes are identified so that the references can be provided for power enterprises to determine corresponding effective reliability measures during planning, design, implementation and production stages.展开更多
Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impeda...Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod.展开更多
To study the Very Fast Transient Over-voltage (VFTO) distribution in transformer windings in gas insulated substation (GIS), a systematic methodology based on S-parameters is presented for establishing high-frequency ...To study the Very Fast Transient Over-voltage (VFTO) distribution in transformer windings in gas insulated substation (GIS), a systematic methodology based on S-parameters is presented for establishing high-frequency model of transformer windings. Firstly, voltage transfer functions are derived from S-parameters which are calculated or measured from transformer windings. Secondly, voltage transfer functions are fitted with rational functions by the vector fitting method and then the rational transfer functions are order-reduced by optimal Pade-approximation algorithm. Lastly, the resultant voltage transfer functions are synthesized by network technology. Computational results are consistent with simulation results of Electromagnetic Transient Program (EMTP) and confirm the feasibility and validity of proposed methodology.展开更多
基金supported by National Natural Science Foundation of China(No.50637010)
文摘Based on the transmission line code TLCODE, a 1D circuit model for a transmission- line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy- transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Г (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Г, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%.
文摘The conformal transformation solution is presented for the attenuation constant ofTEM transmission lines which can be mapped into the coaxial or the parallel plate lines by certainconformal transformations including the numerical ones.The analytic and numerical results ofsome examples are also given.
文摘A new approach, based on the waveform relaxation technique and fast Walsh trans-form, is presented to analyze the coupled loosy transmission lines (CLTL) with arbitrary terminalnetworks. The simulation accuracy of the new method can be greatly improved, the disadvantagewhich always exists in previous methods can be avoided and a considerable saving in time andmemory of CPU is obtained.
文摘This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance.
基金Supported by the Open Project of Jiangsu Key Laboratory of Environmental Engineering(ZX2017005)
文摘Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home and abroad were introduced.Moreover,the problems existing in the on-line monitoring of electromagnetic environment were expounded,and the development prospect was forecasted.
基金Supported by National Natural Science Foundation of China(Grant No51605229)Natural Science Foundation of Higher Education Institutions of Jiangsu Province,China(Grant No.16KJB460016)+1 种基金the“333”Project of Jiangsu Province,China(Grant No.BRA2015310)China Postdoctora Science Foundation(Grant No.2016M601844)
文摘Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.
基金supported by National Natural Science Foundation of China (Nos. 50637010, 51077111)the State Key Laboratory of Electrical Insulation and Power Equipment of Xi'an Jiaotong University of China (EIPE 09207)
文摘Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a higher impedance profile of the internal transmission line would lead to a wider adjustment range for the output current rise time and a narrower adjustment range for the current peak. The number of cavities in series has a positive effect on the output- pulse shaping capability of LTD. Such an improvement in the output-pulse shaping capability can primarily be ascribed to the increment in the axial electric length of LTD. For a triggering time interval longer than the time taken by a pulse to propagate through the length of one cavity, the output parameters of LTD could be improved significantly. The present insulating capability of gas switches and other elements in the LTD cavities may only tolerate a slightly longer deviation in the triggering time interval. It is feasible for the LTD module to reduce the output current rise time, though it is not useful to improve the peak power effectively.
基金supported partly by National Natural Science Foundation of China(Nos.50637010,51077111)partly by the State Key Laboratory of Electrical Insulation and Power Equipment of Xi'an Jiaotong University of China(EIPE09207)
文摘A whole circuit model of a linear transformer drivers (LTD) module composed of 60 cavities in series was developed in the software PSPICE to study the influence of switching jitter on the operational performances of LTDs. In the model, each brick in each cavity is capable of operating with jitter in its switch. Additionally, the manner of triggering cables entering into cavities was considered. The performances of the LTD module operating with three typical cavity-triggering sequences were simulated and the simulation results indicate that switching jitter affects slightly the peak and starting time of the output current pulse. However, the enhancement in switching jitter would significantly lengthen the rise time of the output current pulse. Without considering other factors, a jitter lower than 10 ns may be necessary for the switches in the LTD module to provide output current parameters with an acceptable deviation.
基金Project Supported by Nature Science Foundation Project of CQ CSTC (2008BB615).
文摘A new method of measuring the icing thickness of transmission lines on-line is proposed in this paper.In this method,the pictures of transmission lines which are photoed by the camera on the iron tower are processed immediately to extract the edges of the transmission line conductor and transmission line insulators.The icing thickness can be gained by comparing the edges of the iced transmission line and the uniced one.Two icing image edge extraction methods are described in detail,that is,a method based on the combination of the wavelet transform and the floating threshold method and a method based on the combination of the optimal threshold method and the mathematical morphology transform.The icing images from the artificial climatic chamber and transmission lines are used to test the methods above.The results show that the method based on the wavelet transform and the floating threshold method does well in the extraction of relatively smooth edges,such as glaze icing on conductor and icing on the insulator;meanwhile,the method based on the optimal threshold method and the mathematical morphology transform does well in the edge extraction of icing on the conductor,especially the opaque rime icing on the conductor with complicated edges.
文摘The objective of this paper is to show an alternative model of a non-transposed three-phase transmission line with a vertical symmetry plane in phase domain. Due the line physical characteristics, it can be represented by a system consisting of a single?phase and a two-phase line. In this system, the equations describing the behavior of the values in single-phase line terminals are known, while the equations for two-phase line to be obtained. Using a transformation matrix written explicitly according to three-phase line parameters, it is possible to obtain the currents and voltages in phase domain of two-phase line. Then, modal values of three-phase line are converted into phase domain and thus obtain the analytical model for this line. To verify the performance of this model, it was used to simulate the energization of a 440 kV three-phase line and the results were compared to results obtained using a classical model.
文摘Through the reliability analysis on transmission and transformation facilities with 220 kV or above voltage level in China in 2010, particularly by investigating the planned and unplanned outage of transformers, circuit breakers and overhead transmission lines with 220 kV, 330 kV and 500 kV level, the weak parts that may influence the operational reliabilities are figured out from technical and liability causes. Moreover, through the research on the device models and comparison of performance indices between domestic and imported devices, the trend of the reliability changes are identified so that the references can be provided for power enterprises to determine corresponding effective reliability measures during planning, design, implementation and production stages.
文摘Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod.
基金the I mportant National Science Foundation of Hebei Province (E2006001036)Science and Tech-nology Project of Hebei Province (072156167)
文摘To study the Very Fast Transient Over-voltage (VFTO) distribution in transformer windings in gas insulated substation (GIS), a systematic methodology based on S-parameters is presented for establishing high-frequency model of transformer windings. Firstly, voltage transfer functions are derived from S-parameters which are calculated or measured from transformer windings. Secondly, voltage transfer functions are fitted with rational functions by the vector fitting method and then the rational transfer functions are order-reduced by optimal Pade-approximation algorithm. Lastly, the resultant voltage transfer functions are synthesized by network technology. Computational results are consistent with simulation results of Electromagnetic Transient Program (EMTP) and confirm the feasibility and validity of proposed methodology.