期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
Wind-induced vibration control of long-span power transmission towers 被引量:1
1
作者 尹鹏 《Journal of Chongqing University》 CAS 2009年第2期112-124,共13页
We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup t... We investigated wind-induced vibration control of long-span power transmission towers based on a case study of the Jingdongnan-Nanyang-Jingmen 1 000 kV transmission line project in P. R. China. The height of the cup tower is 181 m with a ground elevation of 47 m, which makes it a super flexible and wind-sensitive structure. Therefore, we should analyze the wind- resistant capacity of the system. We simulated applicable transverse fluctuating wind velocity field, developed a lead-rubber damper (LRD) for controlling wind-induced vibration of long-span transmission towers, deduced LRD calculation model parameter, and researched the best layout scheme and installation method of LRD. To calculate the wind-induced response of tower-line coupling system in seven layout schemes, we used the time history analysis method, and obtained the efficiencies of wind-induced vibration control. LRD deformation research proved that the damp of all LRDs was efficient under the designed wind velocity when they were laid along the edge of tower heads. We studied the controlling efficiency resulting fTom only applying stiffness to the tower polos where the dampers used to be laid under the designed wind velocity. The results show that the controlling efficiency was not ideal when the stiffness is increased on the poles only. Therefore, LRD should conlxibute to both the stiffness and damp of a structure to effectively reduce the dynamic response of a tower-line coupling system under strong winds. We also discussed the controlling efficiency of LRD under static winds. The results show that there was little difference between displacements derived by the finite clement time history method and those obtained by static wind method conducted by a design institute. This means the simulation on space relevant wind velocity field was accurate and reasonable. 展开更多
关键词 transmission towers lead-rubber damper wind-induced vibration control
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
2
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
Experiment on Leader Propagation Characteristics of Air Gaps in UHVDC Transmission Towers Under Positive Switching Impulse Voltages 被引量:12
3
作者 Xuan Zhou She Chen +4 位作者 Hai Wang Rong Zeng Chijie Zhuang Junjie Yu Yujian Ding 《CSEE Journal of Power and Energy Systems》 SCIE 2015年第3期42-48,共7页
Rapid developments in EHV/UHV transmission systems require a deeper understanding of the mechanism of long air gap discharge.Leader propagation is one of the main processes in long gap breakdown.In this paper,the lead... Rapid developments in EHV/UHV transmission systems require a deeper understanding of the mechanism of long air gap discharge.Leader propagation is one of the main processes in long gap breakdown.In this paper,the leader propagation characteristics of real size±800 kV UHVDC transmission tower gaps under positive switching impulse voltages(185/2290μs)are investigated.An integrated observation platform consisting of an impulse voltage divider,a coaxial shunt,a high-speed video camera,and a set of integrated optical electric field sensors(IOES),is established.The waveforms of impulse voltage,discharge current,electric field variation at specific positions,and time-resolved photographs of discharge morphology are recorded.Axial leader velocity and the relationship between leader advancements and injected charge are obtained.The typical value of leader stable propagation velocity is 1.7–2.2 cm/μs,which varies slightly with the gap length and applied voltage amplitude.The leader velocity in the re-illumination process is much higher,and is seen as varying from 5 cm/μs to 30 cm/μs,with an average value around 10 cm/μs.The charge in leader channel per unit length is 20–40μC/m,which illustrates a near-direct proportion relationship between discharge current and leader velocity.The observed parameters are important for further simulation of the tower gap breakdown processes. 展开更多
关键词 Integrated observation platform leader propagation characteristics long air gap discharge positive switching impulses UHVDC transmission tower
原文传递
Dynamic Analysis of Overhead Transmission Lines under Turbulent Wind Loading 被引量:2
4
作者 Alok Dua Mathias Clobes +1 位作者 Thomas Hobbel Vasant Matsagar 《Open Journal of Civil Engineering》 2015年第4期359-371,共13页
Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode.... Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode. Finite element design software SAP2000 was used to model the towers and lines. Non-linear dynamic analysis including the large displacement effects was carried out. Macroscopic aspects of wind coherence along element length and integration time step were investigated. An approach is presented to compare the probabilistic dynamic response due to 7 different stochastically simulated wind fields with the response according to EN-50341. The developed model will be used to study the response recorded on a test line due to the actual wind speed time history recorded. It was found that static load from EN overestimated the strength of conductor cables. The response of coupled system considering towers and cables was found to be different from response of only cables with fixed supports. 展开更多
关键词 Dynamic Analysis Finite Element Method SAP2000 transmission towers transmission Lines
下载PDF
Limits to foundation displacement of an extra high voltage transmission tower in a mining subsidence area 被引量:10
5
作者 Shu Qianjin Yuan Guanglin +1 位作者 Guo Guangli Zhang Yunfeit 《International Journal of Mining Science and Technology》 2012年第1期13-18,共6页
Given the background of a transmission tower erected on a particular mining subsidence area,we used finite element modeling to analyze the anti-deformation performance of transmission towers under a number of differen... Given the background of a transmission tower erected on a particular mining subsidence area,we used finite element modeling to analyze the anti-deformation performance of transmission towers under a number of different load conditions,including horizontal foundation displacement,uneven vertical downward displacement,wind loads and icing conditions.The results show that the failure in stability of a single steel angle iron represents the limit of the tower given ground deformation.We calculated the corresponding limits of foundation displacements.The results indicate that compression displacement of the foundation is more dangerous than tension displacement.Under complex foundation displacement conditions,horizontal foundation displacement is a key factor leading to failure in the stability of towers.Under conditions of compression or tension displacement of the foundation,wind load becomes the key factor.Towers do not fail when foundation displacements are smaller than 1% (under tension) or 0.5% (under horizontal compression or single foundation subsidence) of the distance between two supports. 展开更多
关键词 Mining subsidence area Electricity transmission tower Foundation displacement limit Finite element analysis Limit state Stability failure
下载PDF
A new framework for evaluating along-wind responses of a transmission tower 被引量:3
6
作者 Liu Guohuan and Li Hongnan School of Civil and Hydraulic Engineering, Dalian University of Technology, Dalian 116023, China PhD Professor 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2009年第1期87-93,共7页
In this paper, an analytical framework to evaluate the along-wind-induced dynamic responses of a transmission tower is presented. Two analytical models and a new method are developed: (1) a higher mode generalized ... In this paper, an analytical framework to evaluate the along-wind-induced dynamic responses of a transmission tower is presented. Two analytical models and a new method are developed: (1) a higher mode generalized force spectrum (GFS) model of the transmission tower is deduced; (2) an analytical model that includes the contributions of the higher modes is further derived as a rational algebraic formula to estimate the structural displacement response; and (3) a new approach, applying load with displacement (ALD) instead of force, to solve the internal force of transmission tower is given. Unlike conventional methods, the ALD method can avoid calculating equivalent static wind loads (ESWLs). Finally, a transmission tower structure is used as a numerical example to verify the feasibility and accuracy of the ALD method. 展开更多
关键词 along-wind-induced dynamic responses transmission tower generalized force spectrum equivalent static wind loads
下载PDF
Model experiment on anti-deformation performance of a self-supporting transmission tower in a subsidence area 被引量:3
7
作者 Yuan Guanglin Shu Qianjin +3 位作者 Zhang Yunfei Liu Tao Ji Yongsheng Xu Guoan 《International Journal of Mining Science and Technology》 2012年第1期57-61,共5页
A large number of high-voltage power transmission towers have recently been constructed in mining areas prone to subsidence. In order to ensure the safety of the transmission towers and the safe operation of transmiss... A large number of high-voltage power transmission towers have recently been constructed in mining areas prone to subsidence. In order to ensure the safety of the transmission towers and the safe operation of transmission systems, it is imperative to carry out research on the anti-deformation performance of transmission towers. In our study, we performed experiments on the anti-deformation performance of a transmission tower in a subsidence area on a scale model with a geometric scale ratio of 1:5 and analyzed the failure mechanism of the tower members. The results show that, when the axial distance between two supports changes, destabilization failure most likely occurs in the members of the bottom transverse layer because some parts of the main diagonal member bars yield under the action of compression. The failure mechanism of the tower members basically coincides with the lever principle. 展开更多
关键词 Subsidence area transmission tower Anti-deformation performance Similar model EXPERIMENT
下载PDF
Study on Improvement of Seismic Performance of Transmission Tower Using Viscous Damper 被引量:3
8
作者 Masayuki Matsumoto Akira Kasai +2 位作者 Taiji Mazda Nobuyuki Ishida Yuki Ito 《Journal of Civil Engineering and Architecture》 2017年第5期455-467,共13页
The earthquake resistance of transmission tower has been often discussed from the viewpoint of reinforcing the foundation of steel tower, but there are also few studies considering the damping characteristics of the t... The earthquake resistance of transmission tower has been often discussed from the viewpoint of reinforcing the foundation of steel tower, but there are also few studies considering the damping characteristics of the tower. This paper focuses on the viscous damper which has been adopted for seismic reinforcement of bridges in recent years. The purpose of this study is to improve the seismic performance of steel tower by giving the high damping to the tower. We construct a single tower model considering the influence of transmission line, and then simulate the vibration characteristics and seismic behavior of the tower by the eigenvalue analysis and the dynamic response analysis. The results show that the transmission tower with viscous damper can reduce its own response effectively and drastically. This research concludes that it is necessary to consider the extreme increase of steel tower's response depending on the seismic wave and the collapse of steel tower can be avoided by using the optimum damper in the design of the transmission tower. 展开更多
关键词 Dynamic analysis EARTHQUAKE response reduction seismic damper transmission tower.
下载PDF
Application of Lead Viscoelastic Dampers to Wind Vibration Control on Big-Span Power Transmission Tower 被引量:1
9
作者 梁政平 李黎 +1 位作者 尹鹏 段松涛 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期320-328,共9页
To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and for... To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and force response of the tower was calculated and analyzed. The results show that the control effect of lead viscoelastic dampers is very good, and the damping ratio can reach 20% or more when they are applied to the tower head. 展开更多
关键词 transmission tower Lead viscoelastic damper Wind-induced vibration control
下载PDF
Elastic Dynamic Stability of Big-Span Power Transmission Tower Subjected to Seismic Excitations
10
作者 张行 李黎 +1 位作者 方秦汉 叶昆 《Journal of Southwest Jiaotong University(English Edition)》 2009年第1期65-71,共7页
By combining the time-history response analysis and the eigenvalue buckling analysis, this paper developed a computational procedure to study the elastic dynamic stability of a transmission tower by APDL language in A... By combining the time-history response analysis and the eigenvalue buckling analysis, this paper developed a computational procedure to study the elastic dynamic stability of a transmission tower by APDL language in ANSYS. The influences of different input directions of seismic excitations and damping ratio on the elastic dynamic stability of tower were discussed. The following conclusions were obtained: ( 1 ) Longitudinal direction of the transmission lines is the worst input direction of seismic excitation for the transmission tower. (2) Dead load has no significant effect on the critical load and the occurrence time of buckling. (3) Vertical input of seismic excitations has no great effect on the dynamic stability of the transmission tower. (4) Damping effect has an influence on the dynamic stability of the transmission tower; however, the inherent characteristics of dynamic buckling is not changed. 展开更多
关键词 transmission tower Seismic excitation Elastic dynamic stability Big span
下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
11
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
The Integrated System of Aerial Photogrammetry and Tower Locations Optimization for Transmission Lines
12
作者 Xie Yuan, Pan Yijun, Fu Bin Northwest Power Design Institute 《Electricity》 1996年第4期45-48,共4页
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission... This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system. 展开更多
关键词 PRO The Integrated System of Aerial Photogrammetry and Tower Locations Optimization for transmission Lines
下载PDF
全尺寸交流500 kV输电杆塔复合横担的雷电闪络特性
13
作者 王乾 梁曦东 +3 位作者 沈余峰 刘书明 左周 高岩峰 《Engineering》 SCIE EI CAS CSCD 2023年第4期130-137,M0006,共9页
架空输电线路(OTL)一直以来都是电力传输的主要方式。随着输电电压和输电容量的迅速提高,输电杆塔的尺寸也随之增加,造成土地资源的大量占用。考虑到线路复合绝缘子的优异性能,复合横担有望成为这一问题的解决方案。在本文中,作者制备... 架空输电线路(OTL)一直以来都是电力传输的主要方式。随着输电电压和输电容量的迅速提高,输电杆塔的尺寸也随之增加,造成土地资源的大量占用。考虑到线路复合绝缘子的优异性能,复合横担有望成为这一问题的解决方案。在本文中,作者制备了一个安装有复合横担的全尺寸交流(AC)500 kV输电杆塔,并施加了不同极性的雷电过电压。借助高速相机记录了流注-先导放电的过程,确认了闪络的主要路径。通过测量闪络电压并根据空气密度和湿度对结果进行修正,证实了放电的极性效应。继而,根据杆塔结构和闪络特性计算了杆塔的耐雷水平。基于全尺寸试验的结果与分析,确认了复合横担的可行性,并提出了结构优化方案。 展开更多
关键词 Composite cross arms transmission tower Lightning flashover Streamer discharge Lightning withstand
下载PDF
Fast image recognition of transmission tower based on big data 被引量:23
14
作者 Zhuangli Hu Tong He +7 位作者 Yihui Zeng Xiangyuan Luo Jiawen Wang Sheng Huang Jianming Liang Qinzhang Sun Hengbin Xu Bin Lin 《Protection and Control of Modern Power Systems》 2018年第1期159-168,共10页
Big data technology is more and more widely used in modern power systems.Efficient collection of big data such as equipment status,maintenance and grid operation in power systems,and data mining are the important rese... Big data technology is more and more widely used in modern power systems.Efficient collection of big data such as equipment status,maintenance and grid operation in power systems,and data mining are the important research topics for big data application in smart grid.In this paper,the application of big data technology in fast image recognition of transmission towers which are obtained using fixed-wing unmanned aerial vehicle(UAV)by large range tilt photography are researched.A method that using fast region-based convolutional neural networks(Rcnn)convolutional architecture for fast feature embedding(Caffe)to get deep learning of the massive transmission tower image,extract the image characteristics of the tower,train the tower model,and quickly recognize transmission tower image to generate power lines is proposed.The case study shows that this method can be used in tree barrier modeling of transmission lines,which can replace artificial identification of transmission tower,to reduce the time required for tower identification and generating power line,and improve the efficiency of tree barrier modeling by around 14.2%. 展开更多
关键词 Big data Deep learning Image recognition transmission tower Tree barrier modeling
原文传递
Choosing configurations of transmission line tower grounding by back flashover probability value
15
作者 Dmitry KUKLIN 《Frontiers in Energy》 SCIE CSCD 2016年第2期213-226,共14页
There is a considerable number of works devoted to electrical characteristics of grounding. These characteristics are important in general. However, in application to grounding of transmission line towers they are not... There is a considerable number of works devoted to electrical characteristics of grounding. These characteristics are important in general. However, in application to grounding of transmission line towers they are not enough to determine what grounding construction is preferable in some particular case, because these characteristics are calculated or measured apart from the grounded object, and only limited number of current (or voltage) source waveforms is used. This paper indicates reasons in favor of the fact that to choose the optimum design of grounding, the calculation model should include the tower as it is. The probability of back flashover, which provides both qualitative and quantitative estimate of the grounding structure efficiency, can be taken as the criterion for the grounding design. The insulation flashover probability is calculated on the basis of engineering method, which evaluates breakdown strength of insulation for nonstandard waveshapes, and probability data on lightning currents. Different approaches are examined for identifying the back flashover probability, as not only amplitudes but also other parameters can be taken into account. Finite-difference time-domain method is used for calculations of transients. It is found that lightning current waveform can greatly influence calculated back flashover probability value. 展开更多
关键词 GROUNDING transmission line tower back flashover probability FDTD method
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部