期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Analysis of Protein Content in Panicum miliaceum L. Using Near Infrared Transmittance Spectroscopy 被引量:2
1
作者 牛宇 蒙秋霞 +5 位作者 张丽珍 赵婷婷 乔治军 牛伟 刘根科 冯耐红 《Agricultural Science & Technology》 CAS 2012年第5期965-968,共4页
[Objective] To explore a method for the rapid determination of protein con- tent in grains of Panicum miliaceum L. [Method] The near infrared transmittance spec- troscopy (NITS) was used to build the mathematical mo... [Objective] To explore a method for the rapid determination of protein con- tent in grains of Panicum miliaceum L. [Method] The near infrared transmittance spec- troscopy (NITS) was used to build the mathematical models for the quantitative analy- sis of protein content in the grains. Four combinations of treatment that first derivative and second derivative were respectively combined with partial least squares (PLS) and modified partial least squares (MPLS) were set to compare their effects on the original transmission spectrum. [Result] The predicting effects of the 4 combinations were similar. The optimal combination was first derivative with MPLS, in which the average determination coefficient of validation (RSQ) was 0.880 6, correlation coeffi- cient of cross validation (1-VR) was 0.857 0, standard error of calibration (SEC) was 0.342 4, standard error of cross validation (SECV) was 0.375 1, and the standard er- ror of prediction (SEP) was 0.454. [Conclusion] The constructed NITS model is a rapid way for the determination of protein content in grains of P. miliaceum. 展开更多
关键词 Near infrared transmittance spectroscopy Panicum miliaceum L. PROTEIN Calibration model
下载PDF
Development and implementation of incident response near-infrared models for analyzing contaminated medicines containing diethylene glycol solvent 被引量:1
2
作者 Lihui Yin Xuebo Zhang +1 位作者 Xiaodong Li Shaohong Jin 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2014年第6期97-104,共8页
Samples of preparations contaminated by diethylene glycol(DEG),diethylene glycol raw materials and laboratory prepared solutions were measured to get NIR spectra.Then the iden-tification models were developed using th... Samples of preparations contaminated by diethylene glycol(DEG),diethylene glycol raw materials and laboratory prepared solutions were measured to get NIR spectra.Then the iden-tification models were developed using the collected spectra and the spectra of distilled water,propylene glyool and the preparations without diethylene glyool.Besides,the quantification model was also established for determining the concentration of diethylene glyool in the pre-parations.V alidation results show the identification and quantification models have ideal pre-diction performance.The emergency NIR models are rapid,easy to use and accurate,and can be implemented for identifying diethylene glycol raw material,screening the preparations contam-inated by diethylene glycol in the markets and analyzing the concentrations of DEG. 展开更多
关键词 Diethylene glycol near-infrared transmittance reflectance spectroscopy identification quantification
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部