期刊文献+
共找到3,549篇文章
< 1 2 178 >
每页显示 20 50 100
Trajectory of Walking Function in Late-Stage Older Individuals Managed with a Regular Exercise Program: A 5-Year Longitudinal Tracking with an IoT Gait Analysis System Using Accelerometers
1
作者 Taisuke Ito 《Open Journal of Therapy and Rehabilitation》 2024年第2期174-184,共11页
Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized fo... Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized for preventive care over 5 years, using detailed gait function measurements with an accelerometer-based system. Methods: Seventy individuals (17 male and 53 female) of a daycare service in Tokyo participated in a weekly exercise program, meeting 1 - 2 times. The average age of the participants at the start of the program was 81.4 years. Gait function, including gait speed, stride length, root mean square (RMS) of acceleration, gait cycle time and its standard deviation, and left-right difference in stance time, was evaluated every 6 months. Results: Gait speed and stride length improved considerably within six months of starting the exercise program, confirming an initial improvement in gait function. This suggests that regular exercise programs can maintain or improve gait function even age groups that predictably have a gradual decline in gait ability due to enhanced age. In the long term, many indicators tended to approach baseline values. However, the exercise program seemingly counteracts age-related changes in gait function and maintains a certain level of function. Conclusions: While a decline in gait ability with aging is inevitable, establishing appropriate exercise habits in late-stage older individuals may contribute to long-term maintenance of gait function. 展开更多
关键词 Late-Stage Elderly Exercise Gait Function accelerometER IoT-Based Gait Analysis Device
下载PDF
Association of accelerometer-measured sleep duration and different intensities of physical activity with incident type 2 diabetes in a population-based cohort study 被引量:2
2
作者 Xinyi Jin Yilin Chen +8 位作者 Hongliang Feng Mingqing Zhou Joey W.Y.Chang Yaping Liu Alice Pik Shan Kong Xiao Tan Yun-Kwok Wing Yannis Yan Liang Jihui Zhang 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第2期222-232,共11页
Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a populat... Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a population-based prospective cohort study.Methods:Altogether,88,000 participants(mean age=62.2±7.9 years,mean±SD)were included from the UK Biobank.Sleep duration(short:<6 h/day;normal:6-8 h/day;long:>8 h/day)and PA of different intensities were measured using a wrist-won accelerometer over a 7-day period between 2013 and 2015.PA was classified according to the median or World Health Organization-recommendation:total volume of PA(high,low),moderate-to-vigorous PA(MVPA)(recommended,not recommended),and light-intensity PA(high,low).Incidence of type 2diabetes was ascertained using hospital records or death registries.Results:During a median follow-up of 7.0 years,1615 incident type 2 diabetes cases were documented.Compared with normal sleep duration,short(hazard ratio(HR)=1.21,95%confidence interval(95%CI):1.03-1.41)but not long sleep duration(HR=1.01,95%CI:0.89-1.15)was associated with excessive type 2 diabetes risk.This increased risk among short sleepers seems to be protected against by PA.Compared with normal sleepers with high or recommended PA,short sleepers with low volume of PA(HR=1.81,95%CI:1.46-2.25),not recommended(below the World Health Organization-recommended level of)MVPA(HR=1.92,95%CI:1.55-2.36),or low light-intensity PA(HR=1.49,95%CI:1.13-1.90)had a higher risk of type 2 diabetes,while short sleepers with a high volume of PA(HR=1.14,95%CI:0.88-1.49),recommended MVPA(HR=1.02,95%CI:0.71-1.48),or high light-intensity PA(HR=1.14,95%CI:0.92-1.41)did not.Conclusion:Accelerometer-measured short but not long sleep duration was associated with a higher risk of incident type 2 diabetes.A higher level of PA,regardless of intensity,potentially ameliorates this excessive risk. 展开更多
关键词 Light physical activity Sleep duration Triaxial accelerometer Type 2 diabetes UK Biobank
下载PDF
Efficient Real-Time Devices Based on Accelerometer Using Machine Learning for HAR on Low-Performance Microcontrollers
3
作者 Manh-Tuyen Vi Duc-Nghia Tran +2 位作者 Vu Thi Thuong Nguyen Ngoc Linh Duc-Tan Tran 《Computers, Materials & Continua》 SCIE EI 2024年第10期1729-1756,共28页
Analyzing physical activities through wearable devices is a promising research area for improving health assessment.This research focuses on the development of an affordable and real-time Human Activity Recognition(HA... Analyzing physical activities through wearable devices is a promising research area for improving health assessment.This research focuses on the development of an affordable and real-time Human Activity Recognition(HAR)system designed to operate on low-performance microcontrollers.The system utilizes data from a bodyworn accelerometer to recognize and classify human activities,providing a cost-effective,easy-to-use,and highly accurate solution.A key challenge addressed in this study is the execution of efficient motion recognition within a resource-constrained environment.The system employs a Random Forest(RF)classifier,which outperforms Gradient Boosting Decision Trees(GBDT),Support Vector Machines(SVM),and K-Nearest Neighbors(KNN)in terms of accuracy and computational efficiency.The proposed features Average absolute deviation(AAD),Standard deviation(STD),Interquartile range(IQR),Range,and Root mean square(RMS).The research has conducted numerous experiments and comparisons to establish optimal parameters for ensuring system effectiveness,including setting a sampling frequency of 50 Hz and selecting an 8-s window size with a 40%overlap between windows.Validation was conducted on both the WISDM public dataset and a self-collected dataset,focusing on five fundamental daily activities:Standing,Sitting,Jogging,Walking,and Walking the stairs.The results demonstrated high recognition accuracy,with the system achieving 96.7%on the WISDM dataset and 97.13%on the collected dataset.This research confirms the feasibility of deploying HAR systems on low-performance microcontrollers and highlights the system’s potential applications in patient support,rehabilitation,and elderly care. 展开更多
关键词 accelerometER CLASSIFICATION wearable computing activity recognition HAR
下载PDF
Design and simulation of an accelerometer based on NV center spin–strain coupling
4
作者 季鲁敏 赵立业 王裕海 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期192-198,共7页
The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-s... The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-state platforms.In this paper,an acceleration sensing scheme based on NV spin–strain coupling is proposed,which can effectively eliminate the influence of the stray noise field introduced by traditional mechanical schemes.Through the finite element simulation,it is found that the measurement bandwidth of this ensemble NV spin system ranges from 3 kHz to hundreds of kHz with structure√optimization.The required power is at the sub-μW level,corresponding to a noise-limited sensitivity of 6.7×10^(-5) /√Hz.Compared with other types of accelerometers,this micro-sized diamond sensor proposed here has low power consumption,exquisite sensitivity,and integration potential.This research opens a fresh perspective to realize an accelerometer with appealing comprehensive performance applied in biomechanics and inertial measurement fields. 展开更多
关键词 nitrogen-vacancy(NV)accelerometer spin–strain DIAMOND
下载PDF
ATTITUDE MEASUREMENT ON HIGH-SPINNING PROJECTILE USING MAGNETIC SENSORS AND ACCELEROMETERS 被引量:5
5
作者 李玎 卜雄洙 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2008年第2期106-112,共7页
In allusion to the limitations of the traditional attitude measurement system consisting of a three-axis magnetic sensor and two accelerometers on high-spinning projectile, a new scheme comprised of two magnetic senso... In allusion to the limitations of the traditional attitude measurement system consisting of a three-axis magnetic sensor and two accelerometers on high-spinning projectile, a new scheme comprised of two magnetic sensors and two accelerometers installed in a particular way is given. The configuration of the sensors is described. The calculation method and the mathematical model of the projectile attitude based on the sensor configuration are discussed. The basic calculation method including the Magsonde Window, the proof of the ratios of maximums and minimums and the calculation of the attitude angles are analyzed in theory. Finally, the system is simulated under the given conditions. The simulation result indicates that the estimated attitude angles are in agreement with the true attitude angles. 展开更多
关键词 PROJECTILE MAGNETOMETERS accelerometers attitude solution digital simulation
下载PDF
System-Level Modeling and Simulation of Force-Balance MEMS Accelerometers 被引量:1
6
作者 张宇峰 刘晓为 陈伟平 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第5期917-922,共6页
This paper presents two approaches for system-level simulation of force-balance accelerometers. The derivation of the system-level model is elaborated and simulation results are obtained from the implementation of tho... This paper presents two approaches for system-level simulation of force-balance accelerometers. The derivation of the system-level model is elaborated and simulation results are obtained from the implementation of those strategies on the fabricated silicon force-balance MEMS accelerometer. The mathematical model presented is implemented in VHDL- AMS and SIMULINK TM,respectively. The simulation results from the two approaches are compared and show a slight difference. Using VHDL-AMS is flexible,reusable,and more accurate. But there is not a mature solver developed for the language and this approach takes more time, while the simulation model can be easily built and quickly evaluated using SIMULINK. 展开更多
关键词 MEMS force-balance accelerometers system-level simulation mathematical model
下载PDF
Design and application of single-antenna GPS/accelerometers attitude determination system 被引量:4
7
作者 He Jie Huang Xianlin Wang Guofeng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第2期220-227,共8页
In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system ... In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV). 展开更多
关键词 single-antenna GPS attitude determination vector space accelerometER integrated navigation MAV.
下载PDF
Effect of annealing temperature on the microstructure and optoelectrical properties of ZnO thin films and their application in self-powered accelerometers 被引量:2
8
作者 Xiao-zhou Zhang Yan-ping Xia +3 位作者 Xing Liu Yi-ming Zhong Hai-bo Zhao Pei-hong Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2019年第9期1186-1193,共8页
This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron spu... This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron sputtering machine was used. Polymethyl methacrylate(PMMA) and aluminum-doped zinc oxide(AZO) were used as the insulating layer and the top electrode of the NG, respectively. The experimental results show that the ZnO thin films annealed at 150℃ exhibited the highest crystallinity among the prepared films and an optical band gap of 3.24 eV. The NG fabricated with an AZO/PMMA/ZnO/stainless steel configuration exhibited a higher output voltage than the device with an AZO/ZnO/PMMA/stainless steel configuration. In addition, the annealing temperature affected the open-circuit voltage of the NGs;the output voltage reached 3.81 V when the annealing temperature was 150℃. The open-circuit voltage of the prepared self-powered accelerometer increased linearly with acceleration. In addition, the small NG-based accelerometer, which exhibited excellent fatigue resistance, can be used for acceleration measurements of small and lightweight devices. 展开更多
关键词 piezoelectric ZnO thin film RF MAGNETRON SPUTTERING ANNEALING temperature accelerometER
下载PDF
Review of micromachined optical accelerometers:from mg to sub-μg 被引量:12
9
作者 Qianbo Lu Yinan Wang +3 位作者 Xiaoxu Wang Yuan Yao Xuewen Wang Wei Huang 《Opto-Electronic Advances》 SCIE 2021年第3期1-24,共24页
Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume... Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume and anti-electromagnetic disturbance measurement of acceleration.In recent years,with the in-depth research and development of MOEMS accelerometers,the community is flourishing with the possible applications in seismic monitoring,inertial navigation,aerospace and other industrial and military fields.There have been a variety of schemes of MOEMS accelerometers,whereas the performances differ greatly due to different measurement principles and corresponding application requirements.This paper aims to address the pressing issue of the current lack of systematic review of MOEMS accelerometers.According to the optical measurement principle,we divide the MOEMS accelerometers into three categories:the geometric optics based,the wave optics based,and the new optomechanical accelerometers.Regarding the most widely studied category,the wave optics based accelerometers are further divided into four sub-categories,which is based on grating interferometric cavity,Fiber Bragg Grating(FBG),Fabry-Perot cavity,and photonic crystal,respectively.Following a brief introduction to the measurement principles,the typical performances,advantages and disadvantages as well as the potential application scenarios of all kinds of MOEMS accelerometers are discussed on the basis of typical demonstrations.This paper also presents the status and development tendency of MOEMS accelerometers to meet the ever-increasing demand for high-precision acceleration measurement. 展开更多
关键词 accelerometER Micro-Opto-Electro-Mechanical Systems(MOEMS) integrated optics accelerometer review
下载PDF
Understanding Tremor in Rapid Upper Limb Movements Using 3D Accelerometers Data 被引量:3
10
作者 Paula Pascoal-Faria Miguel Patrício +4 位作者 Adriana Leal Francisco Caramelo António Freire Cristina Januário Miguel Castelo-Branco 《Neuroscience & Medicine》 2014年第5期205-213,共9页
Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss ... Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss of dopamine neurons in the nigrostriatal system that leads to widespread motor symptoms such as bradykinesia, rigidity, tremor and postural instability. ET typically involves a tremor of the arms, hands or fingers. No definitive test or biomarker is yet available for PD or ET, so the rate of misdiagnosis is relatively high. As tremor is a very common feature at the onset of both diseases, it is crucial to be able to characterize it. This is made possible using acce?lerometers to quantify the tremor amplitude and frequency. In this work we aim to find tasks involving upper limb movements that are suitable to modulate both types of tremor. Four tasks were tested, differing on whether the arms moved together or alternatingly and whether loads were added. Significant differences in tremor measures were found when patients were asked to perform simultaneous rapid arms movements with loads placed on their wrists. These results may allow the design of an efficient fMRI protocol for identifying the cortical circuits responsible for the modulation of tremor. 展开更多
关键词 DISEASE ESSENTIAL TREMOR TREMOR Quantification TREMOR MODULATION accelerometers
下载PDF
Quantitative investigation of multi-fracture morphology during TPDF through true tri-axial fracturing experiments and CT scanning 被引量:6
11
作者 Ming-Hui Li Fu-Jian Zhou +3 位作者 Jin-Jun Liu Li-Shan Yuan Guo-Peng Huang Bo Wang 《Petroleum Science》 SCIE CAS CSCD 2022年第4期1700-1717,共18页
Due to the reservoir heterogeneity and the stress shadow effect, multiple hydraulic fractures within one fracturing segment cannot be initiated simultaneously and propagate evenly, which will cause a low effectiveness... Due to the reservoir heterogeneity and the stress shadow effect, multiple hydraulic fractures within one fracturing segment cannot be initiated simultaneously and propagate evenly, which will cause a low effectiveness of reservoir stimulation. Temporary plugging and diverting fracturing(TPDF) is considered to be a potential uniform-stimulation method for creating multiple fractures simultaneously in the oilfield. However, the multi-fracture propagation morphology during TPDF is not clear now. The purpose of this study is to quantitatively investigate the multi-fracture propagation morphology during TPDF through true tri-axial fracturing experiments and CT scanning. Critical parameters such as fracture spacing, number of perforation clusters, the viscosity of fracturing fluid, and the in-situ stress have been investigated. The fracture geometry before and after diversion have been quantitively analyzed based on the two-dimensional CT slices and three-dimensional reconstruction method. The main conclusions are as follows:(1) When injecting the high viscosity fluid or perforating at the location with low in-situ stress, multiple hydraulic fractures would simultaneously propagate. Otherwise, only one hydraulic fracture was created during the initial fracturing stage(IFS) for most tests.(2) The perforation cluster effectiveness(PCE) has increased from 26.62% during the IFS to 88.86% after using diverters.(3) The diverted fracture volume has no apparent correlation with the pressure peak and peak frequency during the diversion fracturing stage(DFS) but is positively correlated with water-work.(4) Four types of plugging behavior in shale could be controlled by adjusting the diverter recipe and diverter injection time, and the plugging behavior includes plugging the natural fracture in the wellbore, plugging the previous hydraulic fractures, plugging the fracture tip and plugging the bedding. 展开更多
关键词 Hydraulic fracturing Temporary plugging and diverting fracturing(TPDF) Multiple fracture tri-axial experiment CT scanning
下载PDF
Summary of Research Status and Application of MEMS Accelerometers 被引量:2
12
作者 Weimeng Niu Liqing Fang +4 位作者 Lei Xu Xu Li Ruikun Huo Deqing Guo Ziyuan Qi 《Journal of Computer and Communications》 2018年第12期215-221,共7页
The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS ac... The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS accelerometer, it can be divided into: piezoresistive, piezoelectric, capacitive, tunnel, resonant, electromagnetic, thermocouple, optical, inductive, etc. Due to its outstanding features in terms of size, quality, power consumption and reliability, MEMS sensors are used in military applications and where high environmental resistance is required. MEMS accelerometers are developing rapidly and have good application prospects. In order to make MEMS accelerometers more widely understood, the advantages of MEMS accelerometers are expounded. The research status of MEMS accelerometers is introduced, and MEMS are analyzed. The application of accelerometers in real-world environments, and the development trend of MEMS accelerometers in the future. More scholars will invest in MEMS accelerometer research, pursuing high performance, low power consumption, high precision, multi-function, and interaction. Strong MEMS accelerometers will be ubiquitous in the future. 展开更多
关键词 MEMS TECHNOLOGY MEMS accelerometER
下载PDF
Suitable triggering algorithms for detecting strong ground motions using MEMS accelerometers 被引量:1
13
作者 Ravi Sankar Jakka Siddharth Garg 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期27-35,共9页
With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record... With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record a seismic event depends upon the efficiency of triggering algorithm, apart from the sensor's sensitivity. There are several classic triggering algorithms developed to detect seismic events, ranging from basic amplitude threshold to more sophisticated pattern recognition. Algorithms based on STA/LTA are reported to be computationally efficient for real time monitoring. In this paper, we analyzed several STA/LTA algorithms to check their efficiency and suitability using data obtained from the Quake Catcher Network (network of MEMS accelerometer stations). We found that most of the STA/LTA algorithms are suitable for use with MEMS accelerometer data to accurately detect seismic events. However, the efficiency of any particular algorithm is found to be dependent on the parameter set used (i.e., window width of STA, LTA and threshold level). 展开更多
关键词 strong ground motion triggering algorithms seismic event detection MEMS accelerometers STA/LTA based algorithms
下载PDF
An iterative calibration method for nonlinear coefficients of marine triaxial accelerometers 被引量:2
14
作者 杨杰 吴文启 +1 位作者 武元新 练军想 《Journal of Central South University》 SCIE EI CAS 2013年第11期3103-3115,共13页
Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.Howe... Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.However,two significant accelerometer nonlinear errors need to be attacked to improve the modulation effect.Firstly,the asymmetry scale factor inaccuracy enlarges the errors of frequent zero-cross oscillating specific force measured by non-axial accelerometers.Secondly,the traditional linear model of accelerometers can hardly measure the continued or intermittent acceleration accurately.These two nonlinear errors degrade the high-precision specific force measurement and the calibration of nonlinear coefficients because triaxial accelerometers is urgent for the marine navigation.Based on the digital signal sampling property,the square coefficients and cross-coupling coefficients of accelerometers are considered.Meanwhile,the asymmetry scale factors are considered in the I-F conversion unit.Thus,a nonlinear model of specific force measurement is established compared to the linear model.Based on the three-axis turntable,the triaxial gyroscopes are utilized to measure the specific force observation for triaxial accelerometers.Considering the nonlinear combination,the standard calibration parameters and asymmetry factors are separately estimated by a two-step iterative identification procedure.Besides,an efficient specific force calculation model is approximately derived to reduce the real-time computation cost.Simulation results illustrate the sufficient estimation accuracy of nonlinear coefficients.The experiments demonstrate that the nonlinear model shows much higher accuracy than the linear model in both the gravimetry and sway navigation validations. 展开更多
关键词 ship navigation single-axis rotation inertial system laser gyroscopes quartz accelerometers nonlinear calibration
下载PDF
Hydrologically induced orientation variations of a tri-axial Earth's principal axes based on satellite-gravimetric and hydrological models 被引量:1
15
作者 Shen Wenbin Sun Rong 《Geodesy and Geodynamics》 2013年第2期30-39,共10页
The Earth is a tri-axial body, with unequal principal inertia moments, A, B and C. The corresponding principal axes a, b and c are determined by the mass distribution of the Earth, and their orientations vary with the... The Earth is a tri-axial body, with unequal principal inertia moments, A, B and C. The corresponding principal axes a, b and c are determined by the mass distribution of the Earth, and their orientations vary with the mass redistribution. In this study, the hydrologically induced variations are estimated on the basis of satellite gravimetric data, including those from satellite laser ranging (SLR) and gravity recovery and climate experiment (GRACE), and hydrological models from global land data assimilation system (GLDAS). The longitude variations of a and b are mainly related to the variations of the spherical harmonic coefficients C 22 and S 22, which have been estimated to be consisting annual variations of about 1.6 arc seconds and 1.8 arc seconds, respectively, from gravity data. This result is confirmed by land surface water storage provided by the GLDAS model. If the atmospheric and oceanic signals are removed from the spherical harmonic coefficients C 21 and S 21, the agreement of the orientation series for c becomes poor, possibly due to the inaccurate background models used in pre-processing of the satellite gravimetric data. Determination of the orientation variations may provide a better understanding of various phenomena in the study of the rotation of a tri-axial Earth. 展开更多
关键词 SLR GRACE GLDAS tri-axial axes orientation variation
下载PDF
Determination of Direction of Arrival of Seismic Wave by a Single Tri-axial Fiber Optic Geophone 被引量:1
16
作者 CHANG Tianying CUI Hongliang 《Defence Technology(防务技术)》 SCIE EI CAS 2013年第1期1-10,共10页
A fiber Bragg grating (FBG) geophone and a surface seismic wave-based algorithm for detecting the direction of arrival (DOA) are described. The operational principle of FBG geophone is introduced and illustrated with ... A fiber Bragg grating (FBG) geophone and a surface seismic wave-based algorithm for detecting the direction of arrival (DOA) are described. The operational principle of FBG geophone is introduced and illustrated with systematic experimental data, demonstrating an improved FBG geophone with many advantages over the conventional geophones. An innovative, robust, and simple algorithm is developed for obtaining the bearing information on the seismic events, such as people walking, or vehicles moving. Such DOA estimate is based on the interactions and projections of surface-propagating seismic waves generated by the moving personnel or vehicles with a single tri-axial seismic sensor based on FBGs. Of particular interest is the case when the distance between the source of the seismic wave and the detector is less than or comparable to one wavelength (less than 100 m), corresponding to near-field detection, where an effective method of DOA finding lacks. 展开更多
关键词 information processing fiber optic geophone direction of arrival (DOA) tri-axial seismic wave sensing surface seismic wave
下载PDF
Rigid Bridges Health Dynamic Monitoring Using 100 Hz GPS Single-Frequency and Accelerometers 被引量:1
17
作者 Joao Olympio de Araújo Neto Jorge Luiz Alves Trabanco +2 位作者 Ana Paula C.Larocca Andre Luiz Cunha Marcelo Carvalho dos Santos 《Positioning》 2019年第2期17-33,共17页
This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was p... This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was performed through the double-difference phase, using the adjusted interferometry technique (i.e. phase residue method—PRM&reg). In the method, the double-difference phase of the carrier L1 is realized by using two satellites only, one was positioned at the zenith of the structure and the other satellite was positioned near the horizon. The results of the parametric adjustment of the PRM observations were finalized through software Interferometry, mathematical algorithm were applied and compared with the accelerometer. The comparison served to validate the use of GPS as a fast and reliable instrument for the preliminary monitoring of the dynamic behavior of the bridge, road artworks which are common in several countries, especially in the Brazilian road network. The data time series from the GPS and accelerometers were processed using the Wavelet. The detection of frequencies means that the combination of 100 Hz GPS receivers and the PRM allows detecting vibrations up to 5 mm. It presented significant results which were never obtained by the Fourier Transform. 展开更多
关键词 GPS Rigid Bridge Modal Frequency Wavelet accelerometER Health Monitoring
下载PDF
Measurement of six degree-of-freedom ground motion by using eight accelerometers
18
作者 杨振宇 沈毅 刘志言 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第2期229-232,共4页
A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual transla... A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual translational acceleration components without gyroscopes. In the proposed measuring system, the relationship between the output from eight force-balance accelerometer and the six DOF motion of the measuring system under an earthquake are described by differential equations. These equations are derived from the positions and directions of the eight force-balance accelerometers in the measuring system. The third-order Runge-Kutta algorithm is used to guarantee the accuracy of the numerical calculation. All the algorithms used to compute the six DOF components of the ground motion are implemented in a real-time in Digital Signal Processor (DSP). The distortion of the measured results caused by position and direction errors of the accelerometers in the measuring system are reduced by multiplying a compensation coefficient C to the output and subtracting static zero drift from the measured results, respectively. 展开更多
关键词 six degree-of-freedom ground motion force-balance accelerometer translational acceleration rotational acceleration
下载PDF
A Survey of Error Analysis and Calibration Methods for MEMS Triaxial Accelerometers
19
作者 Bo Xiao Yinghang Jiang +2 位作者 Qi Liu Xiaodong Liu Mingxu Sun 《Computers, Materials & Continua》 SCIE EI 2020年第7期389-399,共11页
MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safe... MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safety we need to calibrate MEMS accelerometers.Many authors have improved accelerometer accuracy by calculating calibration parameters,and a large number of published calibration methods have been confusing.In this context,this paper introduces these techniques and methods,analyzes and summarizes the main error models and calibration procedures,and provides useful suggestions.Finally,the content of the accelerometer calibration method needs to be overcome. 展开更多
关键词 MEMS accelerometER CALIBRATION error analysis accelerometer calibration
下载PDF
Multiple dependent reliability estimation of large range MEMS accelerometers in high temperature environment
20
作者 QIN Li HE Cheng +2 位作者 YU Li-xia WANG Wei QIN Li-jun 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第1期9-15,共7页
In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure c... In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure condition of large range MEMS accelerometers in high temperature environment,the corresponding accelerated degradation test is designed. According to the degradation condition of zero bias and scale factor,multiple dependent reliability estimation of large range MEMS accelerometers is carried out. The results show that the multiple dependent reliability estimation of the large range MEMS accelerometers can improve the accuracy of the estimation and get more accurate results. 展开更多
关键词 large range MEMS accelerometers zero bias scale factor multiple dependent reliability estimation accelerated degradation test
下载PDF
上一页 1 2 178 下一页 到第
使用帮助 返回顶部