期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Association of accelerometer-measured sleep duration and different intensities of physical activity with incident type 2 diabetes in a population-based cohort study
1
作者 Xinyi Jin Yilin Chen +8 位作者 Hongliang Feng Mingqing Zhou Joey W.Y.Chang Yaping Liu Alice Pik Shan Kong Xiao Tan Yun-Kwok Wing Yannis Yan Liang Jihui Zhang 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第2期222-232,共11页
Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a populat... Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a population-based prospective cohort study.Methods:Altogether,88,000 participants(mean age=62.2±7.9 years,mean±SD)were included from the UK Biobank.Sleep duration(short:<6 h/day;normal:6-8 h/day;long:>8 h/day)and PA of different intensities were measured using a wrist-won accelerometer over a 7-day period between 2013 and 2015.PA was classified according to the median or World Health Organization-recommendation:total volume of PA(high,low),moderate-to-vigorous PA(MVPA)(recommended,not recommended),and light-intensity PA(high,low).Incidence of type 2diabetes was ascertained using hospital records or death registries.Results:During a median follow-up of 7.0 years,1615 incident type 2 diabetes cases were documented.Compared with normal sleep duration,short(hazard ratio(HR)=1.21,95%confidence interval(95%CI):1.03-1.41)but not long sleep duration(HR=1.01,95%CI:0.89-1.15)was associated with excessive type 2 diabetes risk.This increased risk among short sleepers seems to be protected against by PA.Compared with normal sleepers with high or recommended PA,short sleepers with low volume of PA(HR=1.81,95%CI:1.46-2.25),not recommended(below the World Health Organization-recommended level of)MVPA(HR=1.92,95%CI:1.55-2.36),or low light-intensity PA(HR=1.49,95%CI:1.13-1.90)had a higher risk of type 2 diabetes,while short sleepers with a high volume of PA(HR=1.14,95%CI:0.88-1.49),recommended MVPA(HR=1.02,95%CI:0.71-1.48),or high light-intensity PA(HR=1.14,95%CI:0.92-1.41)did not.Conclusion:Accelerometer-measured short but not long sleep duration was associated with a higher risk of incident type 2 diabetes.A higher level of PA,regardless of intensity,potentially ameliorates this excessive risk. 展开更多
关键词 Light physical activity Sleep duration triaxial accelerometer Type 2 diabetes UK Biobank
下载PDF
The dual cycle bridge detection of piezoresistive triaxial accelerometer based on MEMS technology 被引量:3
2
作者 张娟婷 何常德 +4 位作者 张慧 李玉平 张永平 杜春晖 张文栋 《Journal of Semiconductors》 EI CAS CSCD 2014年第6期80-89,共10页
A cycle bridge detection method, which uses a piezoresistive triaxial accelerometer, has been described innovatively. This method just uses eight resistors to form a cycle detection bridge, which can detect the signal... A cycle bridge detection method, which uses a piezoresistive triaxial accelerometer, has been described innovatively. This method just uses eight resistors to form a cycle detection bridge, which can detect the signal of the three directions for real time. It breaks the law of the ordinary independent Wheatstone bridge detection method, which uses at least 12 resistors and each four resistors connected as a Wheatstone bridge to detect the output signal from a specific direction. In order to verify the feasibility of this method, the modeling and simulating of the sensor structure have been conducted by ANSYS, then the dual cycle bridge detection method and independent Wheatstone bridge detection method are compared, the result shows that the former method can improve the sensitivity of the sensor effectively. The sensitivity of the x, y-axis used in the former method is two times that of the sensor used in the latter method, and the sensitivity of the z-axis is four times. At the same time, it can also reduce the cross-axis coupling degree of the sensor used in the dual cycle bridge detection method. In addition, a signal amplifier circuit and adder circuit have been provided, Finally, the test result of the "eight-beams/mass" triaxial accelerometer, which is based on the dual cycle bridge detection method and the related circuits, have been provided. The results of the test and the theoretical analysis are consistent, on the whole. 展开更多
关键词 PIEZORESISTIVE triaxial accelerometer cycle detection bridge MEMS
原文传递
Design and measurement of a piezoresistive triaxial accelerometer based on MEMS technology
3
作者 杜春晖 何常德 +3 位作者 于佳琪 葛晓洋 张永平 张文栋 《Journal of Semiconductors》 EI CAS CSCD 2012年第10期48-52,共5页
With the springing up of the MEMS industry,research on accelerometers is focused on miniaturization, integration,high reliability,and high resolution,and shares extensive application prospects in military and civil fi... With the springing up of the MEMS industry,research on accelerometers is focused on miniaturization, integration,high reliability,and high resolution,and shares extensive application prospects in military and civil fields.Comparing with the traditional single cantilever beam structure or "cantilever-mass" structure,the proposed structure of "8-beams/mass" with its varistor completely symmetric distribution in micro-silicon piezoresistive triaxial accelerometer in this paper has a higher axial sensitivity and smaller cross-axis sensitivity.Adopting ANSYS, the process of structural analysis and the manufacturing flow of sensing unit are showed.In dynamic testing conditions, it can be concluded that the axial sensitivity of x,y,and z are Sx-48μV/g,Sy = 54μV/g and Sz = 217μV/g respectively,and the nonlinearities are 0.4%,0.6%and 0.4%. 展开更多
关键词 cross-axis sensitivity PIEZORESISTIVE symmetric distribution triaxial accelerometer
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部