Triggering characteristics of triggered vacuum switch (TVS), including the discharge delay time, delay jitter, range of operational voltage and peak of pulsed current, are investigated. Both structure and experiment...Triggering characteristics of triggered vacuum switch (TVS), including the discharge delay time, delay jitter, range of operational voltage and peak of pulsed current, are investigated. Both structure and experimental circuit of TVS are presented. The results indicate that TVS, as a surface flashover triggering device with high dielectric permittivity material, is with excellent triggering characteristics. When the hold-off voltage reaches 120 kV, the minimum operational voltage is 1.3 kV, and the minimum discharge delay time and jitter are 100 ns and ±10 ns, respectively. The peak current is up to 240 kA when the operational voltage reaches 100 kV. TVS can well satisfy the main demands of high voltage and current applications, and can also be used under a multi-crowbar circuit.展开更多
The characteristics of the triggered vacuum switch (TVS) are obviously influenced by the emission current ie and emission charge of the trigger device. In this paper, an RC charge collector is designed, and the char...The characteristics of the triggered vacuum switch (TVS) are obviously influenced by the emission current ie and emission charge of the trigger device. In this paper, an RC charge collector is designed, and the characteristics of emission current ie and collecting charge Qc of the trigger device are studied. The experimental results indicate that the emission current ie which is produced by the initial plasma has both positive and negative components, and the polarity of the emission current ie depends mainly on the polarity of the bias voltage UBias. The emission current ie and collecting charge Qe increase with the increase of the trigger voltage Utr and the bias voltage UBias. The emission efficient r] increases linearly with the increase of the bias voltage UBias. When the gap distance is 15 mm and bias voltage UBias is 160 V and trigger voltage Utr is 2.6 kV, the emission efficiency r/reaches 6%展开更多
Triggered vacuum switches(TVSs)have fast growing applications in the field of power system and pulse power.The relation between triggering parameters of triggering system,such as triggering voltage and triggering powe...Triggered vacuum switches(TVSs)have fast growing applications in the field of power system and pulse power.The relation between triggering parameters of triggering system,such as triggering voltage and triggering power,between the triggering time delay and its scatter of TVS had been obtained through series of experiments.The result can be adopted as the steering for high-power controller design and application of TVS.A steepened high-voltage triggering pulse is introduced in the main high-voltage generating circuit.As a result,the triggering time delay and its scatter can be decreased remarkably.Synchronous switch technology is imported to control the triggering phase at the crest of applied voltage on TVS.The Triggering characteristic of TVS under alternating current(AC)and direct current(DC)load has been investigated emphatically.Given the identical triggering parameter of triggering system,DC condition is prior to AC on the triggering probability and stability markedly.Such conclusion can be drawn,for AC condition,TVS would require much for the triggering system.展开更多
基金supported by the New Century Talent Foundation of Ministry of Education of China (NCET-08-0438)
文摘Triggering characteristics of triggered vacuum switch (TVS), including the discharge delay time, delay jitter, range of operational voltage and peak of pulsed current, are investigated. Both structure and experimental circuit of TVS are presented. The results indicate that TVS, as a surface flashover triggering device with high dielectric permittivity material, is with excellent triggering characteristics. When the hold-off voltage reaches 120 kV, the minimum operational voltage is 1.3 kV, and the minimum discharge delay time and jitter are 100 ns and ±10 ns, respectively. The peak current is up to 240 kA when the operational voltage reaches 100 kV. TVS can well satisfy the main demands of high voltage and current applications, and can also be used under a multi-crowbar circuit.
基金supported by National Natural Science Foundation of China(No.51177131)the Fundamental Research Funds for the Central Universities of China(No.xjj20100159)
文摘The characteristics of the triggered vacuum switch (TVS) are obviously influenced by the emission current ie and emission charge of the trigger device. In this paper, an RC charge collector is designed, and the characteristics of emission current ie and collecting charge Qc of the trigger device are studied. The experimental results indicate that the emission current ie which is produced by the initial plasma has both positive and negative components, and the polarity of the emission current ie depends mainly on the polarity of the bias voltage UBias. The emission current ie and collecting charge Qe increase with the increase of the trigger voltage Utr and the bias voltage UBias. The emission efficient r] increases linearly with the increase of the bias voltage UBias. When the gap distance is 15 mm and bias voltage UBias is 160 V and trigger voltage Utr is 2.6 kV, the emission efficiency r/reaches 6%
基金This work was carried out under the support of Guangxi Key Laboratory of Manufacturing System and Advanced Manufacturing Technology(No.0842006_025_Z).
文摘Triggered vacuum switches(TVSs)have fast growing applications in the field of power system and pulse power.The relation between triggering parameters of triggering system,such as triggering voltage and triggering power,between the triggering time delay and its scatter of TVS had been obtained through series of experiments.The result can be adopted as the steering for high-power controller design and application of TVS.A steepened high-voltage triggering pulse is introduced in the main high-voltage generating circuit.As a result,the triggering time delay and its scatter can be decreased remarkably.Synchronous switch technology is imported to control the triggering phase at the crest of applied voltage on TVS.The Triggering characteristic of TVS under alternating current(AC)and direct current(DC)load has been investigated emphatically.Given the identical triggering parameter of triggering system,DC condition is prior to AC on the triggering probability and stability markedly.Such conclusion can be drawn,for AC condition,TVS would require much for the triggering system.