An Active Triggered Surge Protective Gap 被引量:1
1
作者 姚学玲 陈景亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第8期759-764,共6页
A triggered surge protective device is designed and its discharge characteristics axe studied. The experimental results show that the triggered surge protective device has excellent surge protective characteristics. W... A triggered surge protective device is designed and its discharge characteristics axe studied. The experimental results show that the triggered surge protective device has excellent surge protective characteristics. When the gap distance is 5 mm, p. d is 90 Pa.mm and without an active energy trigger circuit, the DC breakdown voltage of the triggered surge protective device is 2.32 kV and the pulse breakdown voltage is 5.75 kV. Therefore, the pulse voltage ratio, which is defined as the specific value of pulse breakdown voltage and DC breakdown voltage, is 2.48. With a semiconductor ZnO flashover trigger device and an active energy coupling trigger circuit, the pulse breakdown voltage can be reduced to 3.32 kV, the pulse voltage ratio is 1.43 and the response time is less than 100 ns. These results are helpful in laying a theoretical foundation for further studies on triggered surge protective devices. 展开更多
关键词 surge protective gap flashover trigger device active energy coupling trigger response time pulse voltage ratio