A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such a...A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such as alpha-fetoprotein (AFP),carcino-embryonic antigen (CEA),prostate specific antigen (PSA),and human chorionic gonadotropin (hCG) in serum,in which every crystal unit can oscillate independently with the stability of±1 hertz (Hz) in air and±2 Hz in liquid.These response characteristics of Pz tumor marker micro-array immunosensor such as temperature, time-cost,reproducibility and specificity etc were also investigated.The detection ranges for AFP,CEA,PSA,and hCG obtained by Pz micro-array immunosensor were 20 ng/ml~640 ng/ml,1.56 ng/ml~50 ng/ml,1.25 ng/ml~50 ng/ml,and 2.5 mIU/ml~250 mlU/mi respectively with the coefficient of variance (CV) less than 5%.No cross-reactivates with other tumor markers in serum were observed.The results of AFP,CEA,PSA,and hCG obtained by this method from 68 serum samples were in good agreement with those given by chemiluminescence immunoassay with the correlation coefficients of 0.92,0.90,0.91,and 0.94 respectively.The Pz immunosensor regenerated by urea solution could be reused for five times without appreciable loss of response activity.Therefore,the proposed insert-plug immunosensor provides a rapid, sensitive,specific,reusable,convenient and reliable alternative for the detection of tumor markers in clinical laboratory.展开更多
Electrochemotherapy(ECT) is a recently described therapy that relies on the permeation of cancer cell membranes by electrical pulses to enhance cytotoxic drug penetration. It has been successfully used in the treatmen...Electrochemotherapy(ECT) is a recently described therapy that relies on the permeation of cancer cell membranes by electrical pulses to enhance cytotoxic drug penetration. It has been successfully used in the treatment of primary and metastatic skin cancer. Systemic chemotherapy is the most commonly used therapeutic strategy, and the prevailing orientation calls for the administration of the maximum tolerated dose; however, considerable limitations exist including toxicities to healthy tissues and low achievable drug concentrations at tumor sites. We reported a case of an 83-years-old patient with a laterocervical metastasis of a squamous epidermoidal lip cancer. The patient had a complex medical history and an implantable cardioverter defibrillator(ICD)/pace-maker. The lesion was localized in the supraclavicular right side with a distance from the pace-maker/ICD about 5 cm, but the nodule was not deeply located. The ECT was performed un-der general anesthesia and particular attention we put on the interference with the functioning of the heart. The synchronization algorithm currently implemented in Clinoporator Vitae device coupled with the external triggering device Accu Sync proved to be effective in preventing external stimulation of the heart during the so-called vulnerable period of the ventricles. As a result all electroporation pulses in our study were delivered outside the vulnerable period and no heart arrhythmias or any other pathological morphological changes were observed. The safety of treatment was demonstrated also by absence of side effects during and after ECT.展开更多
文摘A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such as alpha-fetoprotein (AFP),carcino-embryonic antigen (CEA),prostate specific antigen (PSA),and human chorionic gonadotropin (hCG) in serum,in which every crystal unit can oscillate independently with the stability of±1 hertz (Hz) in air and±2 Hz in liquid.These response characteristics of Pz tumor marker micro-array immunosensor such as temperature, time-cost,reproducibility and specificity etc were also investigated.The detection ranges for AFP,CEA,PSA,and hCG obtained by Pz micro-array immunosensor were 20 ng/ml~640 ng/ml,1.56 ng/ml~50 ng/ml,1.25 ng/ml~50 ng/ml,and 2.5 mIU/ml~250 mlU/mi respectively with the coefficient of variance (CV) less than 5%.No cross-reactivates with other tumor markers in serum were observed.The results of AFP,CEA,PSA,and hCG obtained by this method from 68 serum samples were in good agreement with those given by chemiluminescence immunoassay with the correlation coefficients of 0.92,0.90,0.91,and 0.94 respectively.The Pz immunosensor regenerated by urea solution could be reused for five times without appreciable loss of response activity.Therefore,the proposed insert-plug immunosensor provides a rapid, sensitive,specific,reusable,convenient and reliable alternative for the detection of tumor markers in clinical laboratory.
文摘Electrochemotherapy(ECT) is a recently described therapy that relies on the permeation of cancer cell membranes by electrical pulses to enhance cytotoxic drug penetration. It has been successfully used in the treatment of primary and metastatic skin cancer. Systemic chemotherapy is the most commonly used therapeutic strategy, and the prevailing orientation calls for the administration of the maximum tolerated dose; however, considerable limitations exist including toxicities to healthy tissues and low achievable drug concentrations at tumor sites. We reported a case of an 83-years-old patient with a laterocervical metastasis of a squamous epidermoidal lip cancer. The patient had a complex medical history and an implantable cardioverter defibrillator(ICD)/pace-maker. The lesion was localized in the supraclavicular right side with a distance from the pace-maker/ICD about 5 cm, but the nodule was not deeply located. The ECT was performed un-der general anesthesia and particular attention we put on the interference with the functioning of the heart. The synchronization algorithm currently implemented in Clinoporator Vitae device coupled with the external triggering device Accu Sync proved to be effective in preventing external stimulation of the heart during the so-called vulnerable period of the ventricles. As a result all electroporation pulses in our study were delivered outside the vulnerable period and no heart arrhythmias or any other pathological morphological changes were observed. The safety of treatment was demonstrated also by absence of side effects during and after ECT.