A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such a...A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such as alpha-fetoprotein (AFP),carcino-embryonic antigen (CEA),prostate specific antigen (PSA),and human chorionic gonadotropin (hCG) in serum,in which every crystal unit can oscillate independently with the stability of±1 hertz (Hz) in air and±2 Hz in liquid.These response characteristics of Pz tumor marker micro-array immunosensor such as temperature, time-cost,reproducibility and specificity etc were also investigated.The detection ranges for AFP,CEA,PSA,and hCG obtained by Pz micro-array immunosensor were 20 ng/ml~640 ng/ml,1.56 ng/ml~50 ng/ml,1.25 ng/ml~50 ng/ml,and 2.5 mIU/ml~250 mlU/mi respectively with the coefficient of variance (CV) less than 5%.No cross-reactivates with other tumor markers in serum were observed.The results of AFP,CEA,PSA,and hCG obtained by this method from 68 serum samples were in good agreement with those given by chemiluminescence immunoassay with the correlation coefficients of 0.92,0.90,0.91,and 0.94 respectively.The Pz immunosensor regenerated by urea solution could be reused for five times without appreciable loss of response activity.Therefore,the proposed insert-plug immunosensor provides a rapid, sensitive,specific,reusable,convenient and reliable alternative for the detection of tumor markers in clinical laboratory.展开更多
Despite there has greater understanding of the pathophysiology in idiopathic pulmonary fibrosis,idiopathic pulmonary fibrosis still remains a challenge in clinical practice and translational research due to its hetero...Despite there has greater understanding of the pathophysiology in idiopathic pulmonary fibrosis,idiopathic pulmonary fibrosis still remains a challenge in clinical practice and translational research due to its heterogeneity.Improvements in molecular techniques have identified potential pathways and targets for diagnosis and therapeutic intervention.Several types of idiopathic pulmonary fibrosis biomarkers such as KL-6,SP-A,SP-D,MMP7 and other potential ones have been studied extensively.In addition,many studies have confirmed that levels of some tumor markers such as CA 19-9,CA 15-3,CEA,CA 125,CYFRA 21-1 are useful for idiopathic pulmonary fibrosis.The present study focuses on serum biomarkers including tumor markers to provide an overview on the current roles of these biomarkers in the setting of diagnosis,prediction as well as response to therapy in idiopathic pulmonary fibrosis.展开更多
文摘A novel 2×5 model of insert-plug piezoelectric quartz crystal tumor marker micro-array immunosensor constructed with screw clamp apparatus has been developed for quantitative detection of the tumor markers such as alpha-fetoprotein (AFP),carcino-embryonic antigen (CEA),prostate specific antigen (PSA),and human chorionic gonadotropin (hCG) in serum,in which every crystal unit can oscillate independently with the stability of±1 hertz (Hz) in air and±2 Hz in liquid.These response characteristics of Pz tumor marker micro-array immunosensor such as temperature, time-cost,reproducibility and specificity etc were also investigated.The detection ranges for AFP,CEA,PSA,and hCG obtained by Pz micro-array immunosensor were 20 ng/ml~640 ng/ml,1.56 ng/ml~50 ng/ml,1.25 ng/ml~50 ng/ml,and 2.5 mIU/ml~250 mlU/mi respectively with the coefficient of variance (CV) less than 5%.No cross-reactivates with other tumor markers in serum were observed.The results of AFP,CEA,PSA,and hCG obtained by this method from 68 serum samples were in good agreement with those given by chemiluminescence immunoassay with the correlation coefficients of 0.92,0.90,0.91,and 0.94 respectively.The Pz immunosensor regenerated by urea solution could be reused for five times without appreciable loss of response activity.Therefore,the proposed insert-plug immunosensor provides a rapid, sensitive,specific,reusable,convenient and reliable alternative for the detection of tumor markers in clinical laboratory.
文摘Despite there has greater understanding of the pathophysiology in idiopathic pulmonary fibrosis,idiopathic pulmonary fibrosis still remains a challenge in clinical practice and translational research due to its heterogeneity.Improvements in molecular techniques have identified potential pathways and targets for diagnosis and therapeutic intervention.Several types of idiopathic pulmonary fibrosis biomarkers such as KL-6,SP-A,SP-D,MMP7 and other potential ones have been studied extensively.In addition,many studies have confirmed that levels of some tumor markers such as CA 19-9,CA 15-3,CEA,CA 125,CYFRA 21-1 are useful for idiopathic pulmonary fibrosis.The present study focuses on serum biomarkers including tumor markers to provide an overview on the current roles of these biomarkers in the setting of diagnosis,prediction as well as response to therapy in idiopathic pulmonary fibrosis.