In the present method of trace elements wire has been developed work, a new preconcentration by adsorption onto a niobium for electrothermal atomization atomic absorption spectrometry (ETAAS) with a tungsten tube at...In the present method of trace elements wire has been developed work, a new preconcentration by adsorption onto a niobium for electrothermal atomization atomic absorption spectrometry (ETAAS) with a tungsten tube atomizer. Detection limits (pg. mL-1) by this method combined with ETAAS were 45 for bismuth, 7.0 for cadmium, 20 for copper, 1.3 for gold, 36 for lead, 65 for manganese, 9.5 for rhodium and 19 for silver.展开更多
Ultrasonic assisted-acid leaching as a fast and accurate sample preparation method is coupled with tungsten coil electrothermal atomic absorption spectrometry(WC-ETAAS)for the determination of trace cadmium in rice.Th...Ultrasonic assisted-acid leaching as a fast and accurate sample preparation method is coupled with tungsten coil electrothermal atomic absorption spectrometry(WC-ETAAS)for the determination of trace cadmium in rice.The limit of detection for cadmium was 6 pg,while the upper linear dynamic range was 40 ng/mL.展开更多
Abstract: Trace gold in geological samples was determined by electrothermal atomic absorption spectrometry after electrodeposition preconcentration on the tungsten coil used as a working electrode and atomizer.After g...Abstract: Trace gold in geological samples was determined by electrothermal atomic absorption spectrometry after electrodeposition preconcentration on the tungsten coil used as a working electrode and atomizer.After gold in sample was preconcentrated by foam,the foam was pyrolyzed.The electrolysis of gold was performed under at-700 mV(relative to a saturated Hg/Hg2Cl2 reference electrode) for 2 min.The limit of detection for the gold sample was 0.05 ng/g,while the upper linear dynamic range was 20 μg/L for gold standard slolution.展开更多
文摘In the present method of trace elements wire has been developed work, a new preconcentration by adsorption onto a niobium for electrothermal atomization atomic absorption spectrometry (ETAAS) with a tungsten tube atomizer. Detection limits (pg. mL-1) by this method combined with ETAAS were 45 for bismuth, 7.0 for cadmium, 20 for copper, 1.3 for gold, 36 for lead, 65 for manganese, 9.5 for rhodium and 19 for silver.
文摘Ultrasonic assisted-acid leaching as a fast and accurate sample preparation method is coupled with tungsten coil electrothermal atomic absorption spectrometry(WC-ETAAS)for the determination of trace cadmium in rice.The limit of detection for cadmium was 6 pg,while the upper linear dynamic range was 40 ng/mL.
文摘Abstract: Trace gold in geological samples was determined by electrothermal atomic absorption spectrometry after electrodeposition preconcentration on the tungsten coil used as a working electrode and atomizer.After gold in sample was preconcentrated by foam,the foam was pyrolyzed.The electrolysis of gold was performed under at-700 mV(relative to a saturated Hg/Hg2Cl2 reference electrode) for 2 min.The limit of detection for the gold sample was 0.05 ng/g,while the upper linear dynamic range was 20 μg/L for gold standard slolution.