High-rise buildings are usually considered as flexible structures with low inherent damping. Therefore, these kinds of buildings are susceptible to wind-induced vibration. Tuned Mass Damper(TMD) can be used as an ef...High-rise buildings are usually considered as flexible structures with low inherent damping. Therefore, these kinds of buildings are susceptible to wind-induced vibration. Tuned Mass Damper(TMD) can be used as an effective device to mitigate excessive vibrations. In this study, Artificial Neural Networks is used to find optimal mechanical properties of TMD for high-rise buildings subjected to wind load. The patterns obtained from structural analysis of different multi degree of freedom(MDF) systems are used for training neural networks. In order to obtain these patterns, structural models of some systems with 10 to 80 degrees-of-freedoms are built in MATLAB/SIMULINK program. Finally, the optimal properties of TMD are determined based on the objective of maximum displacement response reduction. The Auto-Regressive model is used to simulate the wind load. In this way, the uncertainties related to wind loading can be taken into account in neural network’s outputs. After training the neural network, it becomes possible to set the frequency and TMD mass ratio as inputs and get the optimal TMD frequency and damping ratio as outputs. As a case study, a benchmark 76-story office building is considered and the presented procedure is used to obtain optimal characteristics of the TMD for the building.展开更多
With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cau...With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation.展开更多
In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in ...In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in serial or in parallel.The dynamic equations of TID adjacent building damping systems were derived,and the H2 norm criterion was used to optimize and adjust them,so that the system had the optimum damping performance under white noise random excitation.Taking TID frequency ratio and damping ratio as optimization parameters,the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained.The results showed that compared with the classic TMD,TID could obtain a better damping effect in the adjacent buildings.Comparing the TIDs composed of serial or parallel,it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response,while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller.Taking the adjacent building composed of two ten-story frame structures as an example,the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out.It was found that TID had a better damping effect in the full-time range compared with the classic TMD.This paper also studied the potential power of TID in adjacent buildings,which can be converted into available power resources during earthquakes.展开更多
Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-kno...Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control.展开更多
The dynamics of jacket supported offshore wind turbine (OWT) in earthquake environment is one of the progressing focuses in the renewable energy field. Soil-structure interaction (SSI) is a fundamental principle t...The dynamics of jacket supported offshore wind turbine (OWT) in earthquake environment is one of the progressing focuses in the renewable energy field. Soil-structure interaction (SSI) is a fundamental principle to analyze stability and safety of the structure. This study focuses on the performance of the multiple tuned mass damper (MTMD) in minimizing the dynamic responses of the structures objected to seismic loads combined with static wind and wave loads. Response surface methodology (RSM) has been applied to design the MTMD parameters. The analyses have been performed under two different boundary conditions: fixed base (without SSI) and flexible base (with SSI). Two vibration modes of the structure have been suppressed by multi-mode vibration control principle in both cases. The effectiveness of the MTMD in reducing the dynamic response of the structure is presented. The dynamic SSI plays an important role in the seismic behavior of the jacket supported OWT, especially resting on the soft soil deposit. Finally, it shows that excluding the SSI effect could be the reason of overestimating the MTMD performance.展开更多
Optimal design theory for linear tuned mass dampers (TMD) has been thoroughly investigated, but is still under development for nonlinear TMDs. In this paper, optimization procedures in the time domain are proposed f...Optimal design theory for linear tuned mass dampers (TMD) has been thoroughly investigated, but is still under development for nonlinear TMDs. In this paper, optimization procedures in the time domain are proposed for design of a TMD with nonlinear viscous damping. A dynamic analysis of a structure implemented with a nonlinear TMD is conducted first. Optimum design parameters for the nonlinear TMD are searched using an optimization method to minimize the performance index. The feasibility of the proposed optimization method is illustrated numerically by using the Taipei 101 structure implemented with TMD. The sensitivity analysis shows that the performance index is less sensitive to the damping coefficient than to the frequency ratio. Time history analysis is conducted using the Taipei 101 structure implemented with different TMDs under wind excitation. For both linear and nonlinear TMDs, the comfort requirements for building occupants are satisfied as long as the TMD is properly designed. It was found that as the damping exponent increases, the relative displacement of the TMD decreases but the damping force increases.展开更多
The tuned mass damper(TMD) has been successfully applied to the vibration control in machining, while the most widely adopted tuning is equal peaks, which splits the magnitude of the frequency response function(FRF...The tuned mass damper(TMD) has been successfully applied to the vibration control in machining, while the most widely adopted tuning is equal peaks, which splits the magnitude of the frequency response function(FRF) into equal peaks. However, chatter is a special self-excited problem and a chatter-flee machining is determined by FRF at the cutting zone. A TMD tuning aiming at achieving the maximum chatter stability is studied, and it is formulated as an optimization problem of maximizing the minimum negative real part of FRF. By employing the steepest descend method, the optimum frequency and damping ratio of TMD are obtained, and they are compared against the equal peaks tuning. The advantage of the proposed tuning is demonstrated numerically by comparing the minimum point of the negative real part, and is further verified by damping a flexible mode from the fixture of a turning machine. A TMD is designed and placed on the fixture along the vibration of the target mode after performing modal analysis and mode shape visualization. Both of the above two ttmings are applied to modify the tool point FRF by tuning TMD respectively. Chatter stability chart of the turning shows that the proposed tuning can increase the critical depth of cut 37% more than the equal peaks. Cutting tests with an increasing depth of cut are conducted on the turning machine in order to distinguish the stability limit. The tool vibrations during the machining are compared to validate the simulation results. The proposed damping design and optimization routine are able to further increase the chatter suppression effect.展开更多
This paper describes experimental and theoretical investigations of Tuned Liquid Damper (TLD) characteristics for suppressing the wave-excited structural vibration. The structural model for the experiments is scaled a...This paper describes experimental and theoretical investigations of Tuned Liquid Damper (TLD) characteristics for suppressing the wave-excited structural vibration. The structural model for the experiments is scaled according to a full size offshore platform by matching their dynamic properties. Rectangular TLDs of different sizes with partially filled liquid are examined. By observing the performance and behavior of TLDs through laboratory experiments, the Study investigates the influence of a number of parameters, including container size, container shape, frequency ratio, and incident wave characteristics. In an analytical study, a mathematical model that describes the nonlinear behavior of liquid in TLD and the interaction of TLD and structure is prerequisite. The validity of the model is evaluated and simulating results can reasonably match the corresponding experimental results.展开更多
超高层建筑是现代城市建设的重要标志之一,其高度已经超过了传统建筑的极限。然而,随着建筑高度不断增加,地震的破坏力也越来越强,超高层建筑面临着更加严峻的安全挑战。因此,研究超高层建筑防震支撑系统技术非常重要,Tuned Mass Damper...超高层建筑是现代城市建设的重要标志之一,其高度已经超过了传统建筑的极限。然而,随着建筑高度不断增加,地震的破坏力也越来越强,超高层建筑面临着更加严峻的安全挑战。因此,研究超高层建筑防震支撑系统技术非常重要,Tuned Mass Damper(TMD)是一种被广泛研究和应用的超高层建筑防震支撑系统技术,TMD最初是在20世纪60年代提出的,最早应用于桥梁上,后来,TMD被引入到建筑领域,并得到广泛的应用。通过精确调节质量、阻尼和弹性等参数来削弱地震引起的建筑物减震效应,从而减少了建筑物因地震造成的损害和崩塌的风险.展开更多
An approach to seismic response reduction for offshore platforms by the use of the tuned liquid damper is presented in this paper. First of all, the effects of the tuned frequency ratio and excited frequency ratio on ...An approach to seismic response reduction for offshore platforms by the use of the tuned liquid damper is presented in this paper. First of all, the effects of the tuned frequency ratio and excited frequency ratio on the seismic response reduction of the platform structure are investigated. Based on the results, a mechanical model and equation of motion for the TLD-platform system are established. And then effectiveness of the appraoch is verified by numerical calculation.展开更多
The main intention of the present study is to reduce wind, wave, and seismic induced vibrations of jacket- type offshore wind turbines (JOWTs) through a newly developed vibration absorber, called tuned liquid column...The main intention of the present study is to reduce wind, wave, and seismic induced vibrations of jacket- type offshore wind turbines (JOWTs) through a newly developed vibration absorber, called tuned liquid column gas damper (TLCGD). Using a Simulink-based model, an analytical model is developed to simulate global behavior of JOWTs under different dynamic excitations. The study is followed by a parametric study to explore efficiency of the TLCGD in terms of nacelle acceleration reduction under wind, wave, and earthquake loads. Study results indicate that optimum frequency of the TLCGD is rather insensitive to excitation type. In addition, while the gain in vibration control from TLCGDs with higher mass ratios is generally more pronounced, heavy TLCGDs are more sensitive to their tuned frequency such that ill-regulated TLCGD with high mass ratio can lead to destructive results. It is revealed that a well regulated TLCGD has noticeable contribution to the dynamic response of the JOWT under any excitation.展开更多
In this study, the effectiveness of a tuned liquid column-gas damper, TLCGD, on the.suppression of seismic-induced vibrations of steel jacket platforms is evaluated. TLCGD is an interesting choice in the case of jacke...In this study, the effectiveness of a tuned liquid column-gas damper, TLCGD, on the.suppression of seismic-induced vibrations of steel jacket platforms is evaluated. TLCGD is an interesting choice in the case of jacket platforms because it is possible to use the structural elements as the horizontal column of the TLCGD. The objective here is to find the optimum geometric parameters, namely orientation and configuration of vertical columns, length ratio, and area ratio of the TLCGD, considering nonlinear damping of the TLCGD and water-structure interaction between the jacket platform and sea water. The effects of different characteristics of ground motion such as PGA and frequency content on the optimum geometry are also investigated and it is observed that these features have some influence on the optimum area ratio. Finally it is observed that pulse arrangement of ground acceleration is one of the most important parameters affecting the efficiency of a TLCGD. In other words, it is found that the TLCGD's capability to reduce the RMS responses depends only on the frequency content of the ground acceleration, but its capability to reduce the maximum responses depends on both the frequency content and the pulse arrangement of the ground acceleration.展开更多
In this paper, the seismic effectiveness of a density-variable tuned liquid damper (DVTLD) with a sloping bottom is experimentally investigated through a series of shake table tests on a 1/4-scale, 3-story frame str...In this paper, the seismic effectiveness of a density-variable tuned liquid damper (DVTLD) with a sloping bottom is experimentally investigated through a series of shake table tests on a 1/4-scale, 3-story frame structure and numerically simulated by a new semi-analytical model. Special attention was given to reducing the first peak and maximum response under near- and far-field ground motions, and the robustness of a density-variable control system consisting of multiple DVTLDs with closely-spaced frequencies. Adaptable to earthquake excitations, the density-variable control system has been demonstrated to be more effective and more robust than its corresponding traditional tuned liquid damper in suppressing story drift and floor acceleration of the structure. Numerical simulations of the DVTLD-controlled structure agreed very well in phase with experimental results but somewhat overestimated the amplitude of the structural response.展开更多
The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for t...The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for the bridge-TLCD system is established.The governing equations of the system are developed by considering all three displacement components of the deck in vertical,lateral,and torsional vibrations,in which the interactions between the bridge deck,the TLCD,the aeroelastic forces,and the aerodynamic forces are fully reflected.Both buffeting and flutter analyses are carried out.The buffeting analysis is performed through random vibration approach,and a critical flutter condition is identified from flutter analysis.A numerical example is presented to demonstrate the control effectiveness of the damper and it is shown that the TLCD can be an effective device for suppressing wind-induced vibration of long span bridges,either for reducing the buffeting response or increasing the critical flutter wind velocity of the bridge.展开更多
In this paper, the control performance is investigated of Circular Tuned Liquid Column Dampers (CTLCD) over torsional response of offshore platform structures excited by ground motions. Based on the equation of motion...In this paper, the control performance is investigated of Circular Tuned Liquid Column Dampers (CTLCD) over torsional response of offshore platform structures excited by ground motions. Based on the equation of motion for the CTLCD-structure system, the optimal control parameters of CTLCD are given through some derivations on the supposition that the ground motion is a stochastic process. The influence of systematic parameters on the equivalent damping ratio of the structures is analyzed with purely torsional vibration and translational-torsional coupled vibration, respectively. The results show that the Circular Tuned Liquid Column Damper (CTLCD) is an effective torsional response control device.展开更多
Tuned mass dampers (TMD) are well known as one of the most widely adopted devices in vibration control passive strategies. In the past few decades,many methods have been developed to find the optimal parameters of a T...Tuned mass dampers (TMD) are well known as one of the most widely adopted devices in vibration control passive strategies. In the past few decades,many methods have been developed to find the optimal parameters of a TMD installed on a structure and subjected to a random base excitation process,but most of them are usually based on an implicit assumption that all of the structural parameters are deterministic. However,in many real cases this simplification is unacceptable,so robust optimal design criteria becomes aviable alternative to better support engineers in the design process. In Robust Design Optimization (RDO) approaches,indeed the solution must be able to not only minimize the performance but also to limitits variation induced by uncertainty. Most of the currently available RDO methods are based on a probabilistic description of the model uncertainty,even if in many cases they are not able to explicitly include the influence of all the possible sources of uncertainties. Therefore,in this study,a fuzzy version of the robust TMD design optimization problem is proposed. The consistency of the fuzzy approach is studied with respect to the available non-probabilistic formulations reported in the literature and an application to an example of a robust design of a linear TMD subjected to base random vibrations in the presence of fuzzy uncertainties. The results show that the proposed fuzzy-based approach is able to give a set of optimal solutions both in terms of structural efficiency and sensitivity to mechanical and environmental uncertainties.展开更多
The optimisation of earthquake resistance of high buildings by multi-tuned mass dampers was investigated using bionic algorithms. In bionic or evolutionary optimisation studies the properties of parents are crossed an...The optimisation of earthquake resistance of high buildings by multi-tuned mass dampers was investigated using bionic algorithms. In bionic or evolutionary optimisation studies the properties of parents are crossed and mutated to produce a new generation with slightly different properties. The kids which best satisfy the object of the study, become the parents of the next generation. After a series of generations essential improvements of the object may be observed. Tuned mass dampers are widely used to reduce the impact of dynamic excitations on structures. A single mass system and multi-mass oscillators help to explain the mechanics of the dampers. To apply the bionic optimisation strategy to high buildings with passive tuned mass dampers subject to seismic loading a special beam element has been developed. In addition to the 6 degrees of freedom of a conventional beam element, it has 2 degrees of freedom for the displacements of the dampers. It allows for fast studies of many variants. As central result, efficient designs for damping systems along the height of an edifice are found. The impact on the structure may be reduced essentially by the use of such dampers designed to interact in an optimal way.展开更多
For the purpose of comparison and applications, two criteria for the optimum searching are considered, which are the minimization of the minimum of the maximum dynamic magnification factor(Min. Min. Max. DMF) and the ...For the purpose of comparison and applications, two criteria for the optimum searching are considered, which are the minimization of the minimum of the maximum dynamic magnification factor(Min. Min. Max. DMF) and the minimization of the minimum dynamic reduction factor (Min.Min.DRF). A study is carried out to investigate the applicability of designing TMD utilizing the unit modal participation factor. In addition, the design steps for the building frame with TMD are suggested. It is demonstrated that significant reduction in the response can be achieved by adopting the optimum TMD parameters in the present paper.展开更多
Due to the shortage of land in cities and population growth,the significance of high rise buildings has risen.Controlling lateral displacement of structures under different loading such as an earthquake is an importan...Due to the shortage of land in cities and population growth,the significance of high rise buildings has risen.Controlling lateral displacement of structures under different loading such as an earthquake is an important issue for designers.One of the best systems is the diagrid method which is built with diagonal elements with no columns for manufacturing tall buildings.In this study,the effect of the distribution of the tuned mass damper(TMD)on the structural responses of diagrid tall buildings was investigated using a new dynamic method.So,a diagrid structural systems with variable height with TMDs was solved as an example of structure.The reason for the selection of the diagrid system was the formation of a stiffness matrix for the diagonal and angular elements.Therefore,the effect of TMDs distribution on the story drift,base shear and structural behaviour were studied.The obtained outcomes showed that the TMDs distribution does not significantly affect on improving the behaviour of the diagrid structural system during an earthquake.Furthermore,the new dynamic scheme represented in this study has good performance for analyzing different systems.Abbreviation:TMD-tuned mass damper;SATMD-semiactive-tuned mass dampers;MDOF-multiple degrees of freedom;m_(i)-mass of ith story of the building;c_(i)-damping coefficient of the ith story of the building;k_(i)-stiffness of ith story of the building;x_(i)-displacement of the ith story of the building;md-mass of damper;c_(d)-damping coefficient of the damper;k_(d)-stiffness of damper;x_(d)-displacement of TMD;M_(i)-generalized mass of the ith normal mode;C_(i)-generalized damping of the ith normal mode;K_(i)-generalized stiffness of the ith normal mode;K_(i)(t)-generalized load of the ith normal mode;Y_(i)(t)-generalized displacement of the ith normal mode;[M]-matrices of mass;[C]-matrices of damping;{P(t)}-consequence external forces;N_(i)(τ)-interpolation functions;[Ai]-mechanical properties of the structure.展开更多
This research proposes a novel type of variable stiffness tuned particle damper(TPD)for reducing vibrations in boring bars.The TPD integrates the developments of particle damping and dynamical vibration absorber,whose...This research proposes a novel type of variable stiffness tuned particle damper(TPD)for reducing vibrations in boring bars.The TPD integrates the developments of particle damping and dynamical vibration absorber,whose frequency tuning principle is established through an equivalent theoretical model.Based on the multiphase flow theory of gas-solid,it is effective to obtain the equivalent damping and stiffness of the particle damping.The dynamic equations of the coupled system,consisting of a boring bar with the TPD,are built by Hamilton’s principle.The vibration suppression of the TPD is assessed by calculating the amplitude responses of the boring bar both with and without the TPD by the Newmark-beta algorithm.Moreover,an improvement is proposed to the existing gas-solid flow theory,and a comparative analysis of introducing the stiffness term on the damping effect is presented.The parameters of the TPD are optimized by the genetic algorithm,and the results indicate that the optimized TPD effectively reduces the peak response of the boring bar system.展开更多
文摘High-rise buildings are usually considered as flexible structures with low inherent damping. Therefore, these kinds of buildings are susceptible to wind-induced vibration. Tuned Mass Damper(TMD) can be used as an effective device to mitigate excessive vibrations. In this study, Artificial Neural Networks is used to find optimal mechanical properties of TMD for high-rise buildings subjected to wind load. The patterns obtained from structural analysis of different multi degree of freedom(MDF) systems are used for training neural networks. In order to obtain these patterns, structural models of some systems with 10 to 80 degrees-of-freedoms are built in MATLAB/SIMULINK program. Finally, the optimal properties of TMD are determined based on the objective of maximum displacement response reduction. The Auto-Regressive model is used to simulate the wind load. In this way, the uncertainties related to wind loading can be taken into account in neural network’s outputs. After training the neural network, it becomes possible to set the frequency and TMD mass ratio as inputs and get the optimal TMD frequency and damping ratio as outputs. As a case study, a benchmark 76-story office building is considered and the presented procedure is used to obtain optimal characteristics of the TMD for the building.
基金Fundamental Research Funds for the National Natural Science Foundation of China under Grant No.52078084the Natural Science Foundation of Chongqing (cstc2021jcyj-msxmX0623)+2 种基金the 111 project of the Ministry of Educationthe Bureau of Foreign Experts of China under Grant No.B18062China Postdoctoral Science Foundation under Grant No.2021M690838。
文摘With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation.
基金This research was funded by the Natural Science Research Project of Higher Education Institutions in Anhui Province(Grant No.2022AH040045)the Anhui Provincial Natural Science Foundation(Grant No.2008085QE245)the Project of Science and Technology Plan of Department of Housing and Urban-Rural Development of Anhui Province(Grant No.2021-YF22).
文摘In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in serial or in parallel.The dynamic equations of TID adjacent building damping systems were derived,and the H2 norm criterion was used to optimize and adjust them,so that the system had the optimum damping performance under white noise random excitation.Taking TID frequency ratio and damping ratio as optimization parameters,the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained.The results showed that compared with the classic TMD,TID could obtain a better damping effect in the adjacent buildings.Comparing the TIDs composed of serial or parallel,it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response,while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller.Taking the adjacent building composed of two ten-story frame structures as an example,the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out.It was found that TID had a better damping effect in the full-time range compared with the classic TMD.This paper also studied the potential power of TID in adjacent buildings,which can be converted into available power resources during earthquakes.
基金State Key Program of Natural Science Foundation of China Under Grant No.50738002
文摘Tuned mass dampers (TMDs) have been widely used in recent years to mitigate structural vibration. However, the damping mechanisms employed in the TMDs are mostly based on viscous dampers, which have several well-known disadvantages, such as oil leakage and difficult adjustment of damping ratio for an operating TMD. Alternatively, eddy current damping (ECD) that does not require any contact with the main structure is a potential solution. This paper discusses the design, analysis, manufacture and testing of a large-scale horizontal TMD based on ECD. First, the theoretical model of ECD is formulated, then one large-scale horizontal TMD using ECD is constructed, and finally performance tests of the TMD are conducted. The test results show that the proposed TMD has a very low intrinsic damping ratio, while the damping ratio due to ECD is the dominant damping source, which can be as large as 15% in a proper configuration. In addition, the damping ratios estimated with the theoretical model are roughly consistent with those identified from the test results, and the source of this error is investigated. Moreover, it is demonstrated that the damping ratio in the proposed TMD can be easily adjusted by varying the air gap between permanent magnets and conductive plates. In view of practical applications, possible improvements and feasibility considerations for the proposed TMD are then discussed. It is confirmed that the proposed TMD with ECD is reliable and feasible for use in structural vibration control.
基金supported by a grant[MPSS-NH-2015-78]through the DisasterSafety Management Institute funded by Ministry of Public Safety and Security of Korean government
文摘The dynamics of jacket supported offshore wind turbine (OWT) in earthquake environment is one of the progressing focuses in the renewable energy field. Soil-structure interaction (SSI) is a fundamental principle to analyze stability and safety of the structure. This study focuses on the performance of the multiple tuned mass damper (MTMD) in minimizing the dynamic responses of the structures objected to seismic loads combined with static wind and wave loads. Response surface methodology (RSM) has been applied to design the MTMD parameters. The analyses have been performed under two different boundary conditions: fixed base (without SSI) and flexible base (with SSI). Two vibration modes of the structure have been suppressed by multi-mode vibration control principle in both cases. The effectiveness of the MTMD in reducing the dynamic response of the structure is presented. The dynamic SSI plays an important role in the seismic behavior of the jacket supported OWT, especially resting on the soft soil deposit. Finally, it shows that excluding the SSI effect could be the reason of overestimating the MTMD performance.
文摘Optimal design theory for linear tuned mass dampers (TMD) has been thoroughly investigated, but is still under development for nonlinear TMDs. In this paper, optimization procedures in the time domain are proposed for design of a TMD with nonlinear viscous damping. A dynamic analysis of a structure implemented with a nonlinear TMD is conducted first. Optimum design parameters for the nonlinear TMD are searched using an optimization method to minimize the performance index. The feasibility of the proposed optimization method is illustrated numerically by using the Taipei 101 structure implemented with TMD. The sensitivity analysis shows that the performance index is less sensitive to the damping coefficient than to the frequency ratio. Time history analysis is conducted using the Taipei 101 structure implemented with different TMDs under wind excitation. For both linear and nonlinear TMDs, the comfort requirements for building occupants are satisfied as long as the TMD is properly designed. It was found that as the damping exponent increases, the relative displacement of the TMD decreases but the damping force increases.
基金supported by National Technology Support Program of China (Grant No. 2006BAF01B09)Doctoral Foundation of Ministry of Education of China (Grant No. 200800060010)+1 种基金Beijing Municipal Key Laboratory Project of Chinasupport from the Manufacturing Automation Laboratory(MAL) of the University of British Columbia
文摘The tuned mass damper(TMD) has been successfully applied to the vibration control in machining, while the most widely adopted tuning is equal peaks, which splits the magnitude of the frequency response function(FRF) into equal peaks. However, chatter is a special self-excited problem and a chatter-flee machining is determined by FRF at the cutting zone. A TMD tuning aiming at achieving the maximum chatter stability is studied, and it is formulated as an optimization problem of maximizing the minimum negative real part of FRF. By employing the steepest descend method, the optimum frequency and damping ratio of TMD are obtained, and they are compared against the equal peaks tuning. The advantage of the proposed tuning is demonstrated numerically by comparing the minimum point of the negative real part, and is further verified by damping a flexible mode from the fixture of a turning machine. A TMD is designed and placed on the fixture along the vibration of the target mode after performing modal analysis and mode shape visualization. Both of the above two ttmings are applied to modify the tool point FRF by tuning TMD respectively. Chatter stability chart of the turning shows that the proposed tuning can increase the critical depth of cut 37% more than the equal peaks. Cutting tests with an increasing depth of cut are conducted on the turning machine in order to distinguish the stability limit. The tool vibrations during the machining are compared to validate the simulation results. The proposed damping design and optimization routine are able to further increase the chatter suppression effect.
基金This research was financially supported partially by the National Science Foundation of Japan under grant No.10555173 This work was partially supported by the Scholarship from Japan Ministry of Education,Science and Culture.
文摘This paper describes experimental and theoretical investigations of Tuned Liquid Damper (TLD) characteristics for suppressing the wave-excited structural vibration. The structural model for the experiments is scaled according to a full size offshore platform by matching their dynamic properties. Rectangular TLDs of different sizes with partially filled liquid are examined. By observing the performance and behavior of TLDs through laboratory experiments, the Study investigates the influence of a number of parameters, including container size, container shape, frequency ratio, and incident wave characteristics. In an analytical study, a mathematical model that describes the nonlinear behavior of liquid in TLD and the interaction of TLD and structure is prerequisite. The validity of the model is evaluated and simulating results can reasonably match the corresponding experimental results.
文摘超高层建筑是现代城市建设的重要标志之一,其高度已经超过了传统建筑的极限。然而,随着建筑高度不断增加,地震的破坏力也越来越强,超高层建筑面临着更加严峻的安全挑战。因此,研究超高层建筑防震支撑系统技术非常重要,Tuned Mass Damper(TMD)是一种被广泛研究和应用的超高层建筑防震支撑系统技术,TMD最初是在20世纪60年代提出的,最早应用于桥梁上,后来,TMD被引入到建筑领域,并得到广泛的应用。通过精确调节质量、阻尼和弹性等参数来削弱地震引起的建筑物减震效应,从而减少了建筑物因地震造成的损害和崩塌的风险.
文摘An approach to seismic response reduction for offshore platforms by the use of the tuned liquid damper is presented in this paper. First of all, the effects of the tuned frequency ratio and excited frequency ratio on the seismic response reduction of the platform structure are investigated. Based on the results, a mechanical model and equation of motion for the TLD-platform system are established. And then effectiveness of the appraoch is verified by numerical calculation.
文摘The main intention of the present study is to reduce wind, wave, and seismic induced vibrations of jacket- type offshore wind turbines (JOWTs) through a newly developed vibration absorber, called tuned liquid column gas damper (TLCGD). Using a Simulink-based model, an analytical model is developed to simulate global behavior of JOWTs under different dynamic excitations. The study is followed by a parametric study to explore efficiency of the TLCGD in terms of nacelle acceleration reduction under wind, wave, and earthquake loads. Study results indicate that optimum frequency of the TLCGD is rather insensitive to excitation type. In addition, while the gain in vibration control from TLCGDs with higher mass ratios is generally more pronounced, heavy TLCGDs are more sensitive to their tuned frequency such that ill-regulated TLCGD with high mass ratio can lead to destructive results. It is revealed that a well regulated TLCGD has noticeable contribution to the dynamic response of the JOWT under any excitation.
基金Pardis College of Engineering at the Univ. of Tehran Under Project No.8108020/1/01Sabok Sazan Sarie Co
文摘In this study, the effectiveness of a tuned liquid column-gas damper, TLCGD, on the.suppression of seismic-induced vibrations of steel jacket platforms is evaluated. TLCGD is an interesting choice in the case of jacket platforms because it is possible to use the structural elements as the horizontal column of the TLCGD. The objective here is to find the optimum geometric parameters, namely orientation and configuration of vertical columns, length ratio, and area ratio of the TLCGD, considering nonlinear damping of the TLCGD and water-structure interaction between the jacket platform and sea water. The effects of different characteristics of ground motion such as PGA and frequency content on the optimum geometry are also investigated and it is observed that these features have some influence on the optimum area ratio. Finally it is observed that pulse arrangement of ground acceleration is one of the most important parameters affecting the efficiency of a TLCGD. In other words, it is found that the TLCGD's capability to reduce the RMS responses depends only on the frequency content of the ground acceleration, but its capability to reduce the maximum responses depends on both the frequency content and the pulse arrangement of the ground acceleration.
基金U.S. National Science Foundation Under Award No. 0342020the Dean’s Fellowship Program from the University of Missouri-Rolla (renamed to Missouri University of Science and Technology in January 2008)
文摘In this paper, the seismic effectiveness of a density-variable tuned liquid damper (DVTLD) with a sloping bottom is experimentally investigated through a series of shake table tests on a 1/4-scale, 3-story frame structure and numerically simulated by a new semi-analytical model. Special attention was given to reducing the first peak and maximum response under near- and far-field ground motions, and the robustness of a density-variable control system consisting of multiple DVTLDs with closely-spaced frequencies. Adaptable to earthquake excitations, the density-variable control system has been demonstrated to be more effective and more robust than its corresponding traditional tuned liquid damper in suppressing story drift and floor acceleration of the structure. Numerical simulations of the DVTLD-controlled structure agreed very well in phase with experimental results but somewhat overestimated the amplitude of the structural response.
基金the Hong Kong Polytechnic University and the Hong Kong Research Grant Council.
文摘The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for the bridge-TLCD system is established.The governing equations of the system are developed by considering all three displacement components of the deck in vertical,lateral,and torsional vibrations,in which the interactions between the bridge deck,the TLCD,the aeroelastic forces,and the aerodynamic forces are fully reflected.Both buffeting and flutter analyses are carried out.The buffeting analysis is performed through random vibration approach,and a critical flutter condition is identified from flutter analysis.A numerical example is presented to demonstrate the control effectiveness of the damper and it is shown that the TLCD can be an effective device for suppressing wind-induced vibration of long span bridges,either for reducing the buffeting response or increasing the critical flutter wind velocity of the bridge.
文摘In this paper, the control performance is investigated of Circular Tuned Liquid Column Dampers (CTLCD) over torsional response of offshore platform structures excited by ground motions. Based on the equation of motion for the CTLCD-structure system, the optimal control parameters of CTLCD are given through some derivations on the supposition that the ground motion is a stochastic process. The influence of systematic parameters on the equivalent damping ratio of the structures is analyzed with purely torsional vibration and translational-torsional coupled vibration, respectively. The results show that the Circular Tuned Liquid Column Damper (CTLCD) is an effective torsional response control device.
文摘Tuned mass dampers (TMD) are well known as one of the most widely adopted devices in vibration control passive strategies. In the past few decades,many methods have been developed to find the optimal parameters of a TMD installed on a structure and subjected to a random base excitation process,but most of them are usually based on an implicit assumption that all of the structural parameters are deterministic. However,in many real cases this simplification is unacceptable,so robust optimal design criteria becomes aviable alternative to better support engineers in the design process. In Robust Design Optimization (RDO) approaches,indeed the solution must be able to not only minimize the performance but also to limitits variation induced by uncertainty. Most of the currently available RDO methods are based on a probabilistic description of the model uncertainty,even if in many cases they are not able to explicitly include the influence of all the possible sources of uncertainties. Therefore,in this study,a fuzzy version of the robust TMD design optimization problem is proposed. The consistency of the fuzzy approach is studied with respect to the available non-probabilistic formulations reported in the literature and an application to an example of a robust design of a linear TMD subjected to base random vibrations in the presence of fuzzy uncertainties. The results show that the proposed fuzzy-based approach is able to give a set of optimal solutions both in terms of structural efficiency and sensitivity to mechanical and environmental uncertainties.
文摘The optimisation of earthquake resistance of high buildings by multi-tuned mass dampers was investigated using bionic algorithms. In bionic or evolutionary optimisation studies the properties of parents are crossed and mutated to produce a new generation with slightly different properties. The kids which best satisfy the object of the study, become the parents of the next generation. After a series of generations essential improvements of the object may be observed. Tuned mass dampers are widely used to reduce the impact of dynamic excitations on structures. A single mass system and multi-mass oscillators help to explain the mechanics of the dampers. To apply the bionic optimisation strategy to high buildings with passive tuned mass dampers subject to seismic loading a special beam element has been developed. In addition to the 6 degrees of freedom of a conventional beam element, it has 2 degrees of freedom for the displacements of the dampers. It allows for fast studies of many variants. As central result, efficient designs for damping systems along the height of an edifice are found. The impact on the structure may be reduced essentially by the use of such dampers designed to interact in an optimal way.
文摘For the purpose of comparison and applications, two criteria for the optimum searching are considered, which are the minimization of the minimum of the maximum dynamic magnification factor(Min. Min. Max. DMF) and the minimization of the minimum dynamic reduction factor (Min.Min.DRF). A study is carried out to investigate the applicability of designing TMD utilizing the unit modal participation factor. In addition, the design steps for the building frame with TMD are suggested. It is demonstrated that significant reduction in the response can be achieved by adopting the optimum TMD parameters in the present paper.
文摘Due to the shortage of land in cities and population growth,the significance of high rise buildings has risen.Controlling lateral displacement of structures under different loading such as an earthquake is an important issue for designers.One of the best systems is the diagrid method which is built with diagonal elements with no columns for manufacturing tall buildings.In this study,the effect of the distribution of the tuned mass damper(TMD)on the structural responses of diagrid tall buildings was investigated using a new dynamic method.So,a diagrid structural systems with variable height with TMDs was solved as an example of structure.The reason for the selection of the diagrid system was the formation of a stiffness matrix for the diagonal and angular elements.Therefore,the effect of TMDs distribution on the story drift,base shear and structural behaviour were studied.The obtained outcomes showed that the TMDs distribution does not significantly affect on improving the behaviour of the diagrid structural system during an earthquake.Furthermore,the new dynamic scheme represented in this study has good performance for analyzing different systems.Abbreviation:TMD-tuned mass damper;SATMD-semiactive-tuned mass dampers;MDOF-multiple degrees of freedom;m_(i)-mass of ith story of the building;c_(i)-damping coefficient of the ith story of the building;k_(i)-stiffness of ith story of the building;x_(i)-displacement of the ith story of the building;md-mass of damper;c_(d)-damping coefficient of the damper;k_(d)-stiffness of damper;x_(d)-displacement of TMD;M_(i)-generalized mass of the ith normal mode;C_(i)-generalized damping of the ith normal mode;K_(i)-generalized stiffness of the ith normal mode;K_(i)(t)-generalized load of the ith normal mode;Y_(i)(t)-generalized displacement of the ith normal mode;[M]-matrices of mass;[C]-matrices of damping;{P(t)}-consequence external forces;N_(i)(τ)-interpolation functions;[Ai]-mechanical properties of the structure.
基金Project supported by the National Natural Science Foundation of China(Nos.12172014 and 11972050)。
文摘This research proposes a novel type of variable stiffness tuned particle damper(TPD)for reducing vibrations in boring bars.The TPD integrates the developments of particle damping and dynamical vibration absorber,whose frequency tuning principle is established through an equivalent theoretical model.Based on the multiphase flow theory of gas-solid,it is effective to obtain the equivalent damping and stiffness of the particle damping.The dynamic equations of the coupled system,consisting of a boring bar with the TPD,are built by Hamilton’s principle.The vibration suppression of the TPD is assessed by calculating the amplitude responses of the boring bar both with and without the TPD by the Newmark-beta algorithm.Moreover,an improvement is proposed to the existing gas-solid flow theory,and a comparative analysis of introducing the stiffness term on the damping effect is presented.The parameters of the TPD are optimized by the genetic algorithm,and the results indicate that the optimized TPD effectively reduces the peak response of the boring bar system.