期刊文献+
共找到2,068篇文章
< 1 2 104 >
每页显示 20 50 100
Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
1
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
下载PDF
Assessment of Left Atrial Function by Full Volume Real-time Three-dimensional Echocardiography and Left Atrial Tracking in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models 被引量:9
2
作者 Yang Wang Lin Gao +1 位作者 Jian-bai Li Chao Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2013年第3期152-158,共7页
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography(RT-3DE)and left atrial trackin... Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography(RT-3DE)and left atrial tracking(LAT).Methods One hundred and thirty-three patients with essential hypertension were divided into four groups according to criteria proposed by Ganau et al:36 patients in normal pattern group(I),34 patients in concentric remodelling pattern group(II),33 patients in concentric hypertrophy pattern group(III),and 30patients in eccentric hypertrophy pattern group(IV).Thirty-two healthy volunteers were enrolled in this study.RT-3DE and LAT were used to obtain the volume-time and emptying fraction curves,and then the maximal volume,minimal volume,stroke volume,presystolic volume,ejection fraction,systolic filling rate,early diastolic emptying rate and late diastolic emptying rate of the left atrium were measured.Conduit volume and passive emptying volume of the left atrium were calculated.Results Left atrial indexes,conduit volume,passive emptying volume,and early diastolic emptying rate decreased,while the other indices increased in the group I compared with the control group(all P<0.05).Compared with the control group,I and II groups,the left atrial volume parameters manifested change in the group III and group IV(all P<0.01).Left atrial ejection fraction measured by RT-3DE or LAT,and late diastolic emptying rate were lower in the group IV compared with the group III(all P<0.05).There was no difference in left atrial conduit volume,passive emptying volume,and early diastolic left atrial emptying rate between the group II and group I(all P>0.05).There was a positive correlation between RT-3DE and LAT in evaluating left atrial function.Conclusions Left atrial booster pump function decreases in the eccentric hypertrophy pattern.Left atrial conduit function is unchanged in the normal pattern and the concentric remodelling pattern groups.RT-3DE and LAT technology can be used for quantitative evaluation of left atrial volume and function. 展开更多
关键词 高血压患者 超声心动图 几何模型 原发性 心房 跟踪 三维 实时
下载PDF
REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS 被引量:4
3
作者 Hong-wenFei Xin-fangWang +5 位作者 Ming-xingXie LeiZhuang Li-xinChen Run-qingHuang YingYang JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期230-232,共3页
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto... To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience. 展开更多
关键词 实时三维超声波心动描记术 定量法 左心室胞块 心血管疾病
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
4
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 肺的静脉 导管脱离 Atrial 纤维性颤动 Transesophageal echocardiography 三维的 echocardiography
下载PDF
Real-time Three-dimensional Echocardiographic Assessment of Left Ventricular Remodeling Index in Patients with Hypertensive Heart Disease and Coronary Artery Disease 被引量:14
5
作者 陈明 王静 +5 位作者 谢明星 王新房 吕清 王蕾 李燕 付曼丽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第1期122-126,共5页
Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of ... Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controis (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass/EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P〈0.01). There was no significant difference in NC group (P〉0.05), but significant difference in HHD and CAD intra-group (P〈0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (t=0.69, P〈0.01; r=0.68, P〈0.01), but no significant correlation in CAD group (r=0.30, P〉0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE. 展开更多
关键词 echocardiography real-time three-dimensional left ventricular remodeling index hypertensive heart disease coronary artery disease
下载PDF
Assessment of Myocardial Perfusion and Systolic Function in Patients with Coronary Artery Disease after Coronary Artery Bypass Surgery by Myocardial Contrast Echocardiography and Two-dimensional Strain Echocardiography 被引量:5
6
作者 刘蓉 邓又斌 +3 位作者 毕小军 刘娅妮 熊莉 陈刘平 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第5期664-668,共5页
The clinically applied value of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery using real-time myocardial contrast echocardiography (RT-MCE) ... The clinically applied value of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery using real-time myocardial contrast echocardiography (RT-MCE) combined with two-dimensional strain echocardiography was assessed. Twenty patients underwent intravenous RT-MCE by intravenous injections of SonoVue before and after coronary artery bypass surgery. Two-dimensional images were recorded from the left ventricular four-chamber view, two-chamber view and the apical view before, and two weeks and three months after coronary artery bypass surgery, and the peak systolic longitudinal strain was measured. The results showed that myocardial perfusion was significantly increased after coronary artery bypass surgery in about 71.6% segments. In the group that myocardial perfusion was improved, the peak systolic longitu- dinal strain three months after bypass surgery was significantly higher than that before operation [(-15.78±5.91)% vs (-10.45±8.31)%, P〈0.05]. However, the parameters did not change in the group without myocardial perfusion improvement [(-10.33±6.53)% vs (-9.41±6.09)%, P〉0.05]. It was concluded that whether or not the improvement of myocardial perfusion can mirror the recovery trend of regional systolic function, two-dimensional strain echocardiography can observe dynamic change of regional systolic function. The combination of myocardial perfusion with two-dimensional strain echocardiography can more accurately assess the curative effectiveness of coronary artery bypass surgery. 展开更多
关键词 two-dimensional strain myocardial contrast echocardiography myocardial perfusion ventricular function coronary artery disease
下载PDF
QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY 被引量:2
7
作者 Lei Zhuang Ming-xing Xie +2 位作者 Wei-juan Wang Xiang-xin Yang Tao Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第3期135-139,共5页
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed... Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease. 展开更多
关键词 心肌灌注损伤 超声波心动描记术 空间定量 临床
下载PDF
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
8
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
下载PDF
Left Ventricular Systolic Strain of the Cardiac Allograft Evaluated with Three-dimensional Speckle Tracking Echocardiography 被引量:1
9
作者 刘红云 邓又斌 +5 位作者 刘琨 李阳 汤乔颖 魏翔 昌盛 卢峡 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第5期765-769,共5页
Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantati... Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft. 展开更多
关键词 three-dimensional echocardiography speckle tracking imaging heart transplantation
下载PDF
Surgical Resection of Mitral Valve Papillary Fibroelastoma: A Robot-Assisted, Minimally Invasive Approach with Three-Dimensional Transesophageal Echocardiography Imaging 被引量:1
10
作者 Crystal R. Bonnichsen Harold M. Burkhart +1 位作者 Kyle W. Klarich Rakesh M. Suri 《World Journal of Cardiovascular Surgery》 2012年第2期10-13,共4页
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e... Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy. 展开更多
关键词 PAPILLARY FIBROELASTOMA ROBOTIC Surgery Three-dimensional TRANSESOPHAGEAL echocardiography
下载PDF
A 3-dimensional transoesophageal echocardiography perspective of mitral valve abscess
11
作者 Pujan Patel Shreya Ghetiya +1 位作者 Emil Missov Srinivasan Sattiraju 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第2期124-124,共1页
An 85-year-old female with history of dementia presented with concern for severe sepsis and was found to have methicillin sensitive staphylococcus aureus bacteremia complicated by atrial fibrillation.For further worku... An 85-year-old female with history of dementia presented with concern for severe sepsis and was found to have methicillin sensitive staphylococcus aureus bacteremia complicated by atrial fibrillation.For further workup,a transoesophageal echocardiography(TOE)was obtained.The study revealed a large echogenic density with multiple echolucent areas within the finding.There was evidence of blood flow in these echolucent areas based on color flow imaging.This mass was intermittently protruding into the left ventricle causing a function mitral stenosis.The collective findings on echocardiography,in context of bacteremia,were highly suggestive of mitral valve abscess(Figure 1). 展开更多
关键词 ENDOCARDITIS Three dimensional transoesophageal echocardiography Valvular abscess
下载PDF
Assessment of Atrial Septum Morphology by Live Three-dimensional Echocardiography
12
作者 方凌云 谢明星 +4 位作者 王新房 蒲朝霞 杨亚利 贺林 周小燕 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2007年第6期687-690,共4页
To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics... To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics and dynamic change of the overall anatomic structure of atrial septum. The study examined 49 patients with atrial septal defect (ASD), including 3 patients with atrial septal aneurysm, and 10 healthy subjects. ASD in the 35 patients was surgically confirmed. The maximal diameters of ASD were measured and the percentages of area change were calculated. The parameters derived from L3DE were compared with intraoperative measurements. The results showed that L3DE could directly and clearly display the morphological features of overall anatomic structure of normal atrial septum, repaired and artificially-occluded atrial septum, atrial septal aneurysm. The defect area in ASD patients changed significantly during cardiac cycle, which reached a maximum at end-systole and a minimum at end-diastole, with a mean change percentage of 46.6%, ranging from 14.8% to 73.4%. The sizes obtained from L3DE bore an excellent correlation with intraoperative findings (r=0.90). It is concluded that L3DE can clearly display the overall morphological features and dynamic change of atrial septum and measure the size of ASD area accurately, which is important in the decision to choose therapeutic protocols. 展开更多
关键词 live three-dimensional echocardiography atrial septal defects atrial septum
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Congenital Double Orifice Mitral Valve
13
作者 吕清 卢晓芳 +7 位作者 谢明星 王新房 王静 杨亚利 袁莉 贺林 刘夏天 付曼丽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第5期625-628,共4页
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp... The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV. 展开更多
关键词 double orifice mitral valve echocardiography real-time three-dimensional
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Left Ventricular and Right Ventricular Volumes
14
作者 YingYang Xin-fangWang Ming-xingXie JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期236-236,共1页
关键词 实时三维超声波心动描记术 左心室 右心室 RT3DE 心血管疾病
下载PDF
Evaluation of the Effect of Sigmoid-Shaped Interventricular Septum on Left Ventricular Systolic Function in Patients with Essential Hypertension by Two-Dimensional Speckle Tracking Echocardiography
15
作者 Zhifan Zhang Wei Xu +2 位作者 Yudong Peng Hong Zhang Qi Zhang 《Yangtze Medicine》 2020年第1期62-69,共8页
Objective: To evaluate left ventricular regional and global systolic function by measuring left ventricular longitudinal strain (LS) in hypertensive patients with sigmoid-shaped interventricular septum (SIS) by two-di... Objective: To evaluate left ventricular regional and global systolic function by measuring left ventricular longitudinal strain (LS) in hypertensive patients with sigmoid-shaped interventricular septum (SIS) by two-dimensional speckle tracking (2D-STE);in order to explore whether the sigmoid-shaped interventricular septum affects the left ventricular systolic function in patients with hypertension. Methods: Routine echocardiographic parameters were measured in 30 hypertensive patients with SIS (SIS group) and 30 hypertensive patients without SIS (non-SIS group). The left ventricular segments and global LS were measured by 2D-STE, and the two sets of parameters were compared. Results: The value of the thickness of the basal segment of the interventricular septum (IVSBT), the thickness of the middle segment of the interventricular septum (IVSMT) and the ratio of the basal segment of the ventricular septum to the middle segment of the interventricular septum (IVSBT/IVSMT) in SIS group was higher than that in non-SIS group. However, the value of left ventricular outflow tract diameter (LVOTD) in SIS group was lower than that in non-SIS group. There was a significant difference between the two groups (all P Conclusion: SIS affects left ventricular regional systolic function of patients with hypertension. 2D-STE can early evaluate left ventricular longitudinal systolic function in hypertensive patients with SIS. 展开更多
关键词 Sigmoid-Shaped INTERVENTRICULAR SEPTUM Hypertension Left Ventricular SYSTOLIC Function Two-dimensional Speckle Tracking echocardiography echocardiography
下载PDF
Assessment of Regional Left Ventricular Myocardial Function in Rats after Acute Occlusion of Left Anterior Descending Artery by Two-dimensional Speckle Tracking Imaging 被引量:15
16
作者 付倩 谢明星 +5 位作者 王静 王新房 吕清 卢晓芳 方凌云 程龙 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第6期786-790,共5页
This study evaluated the change in regional left ventricular myocardial function in rats following acute occlusion of the left anterior descending coronary artery (LAD) by using two-dimensional speckle tracking imag... This study evaluated the change in regional left ventricular myocardial function in rats following acute occlusion of the left anterior descending coronary artery (LAD) by using two-dimensional speckle tracking imaging (2D-STI). Sixty Wistar rats were randomly divided into two groups, a myocardial infarction (MI) group, in which 50 rats were subjected to LAD occlusion for 30–45 min, and a sham-operated (SHAM) group that contained 10 rats serving as control. Echo-cardiography was performed at baseline and 1, 4 and 8 week(s) after the operation. High frequency two-dimensional images of left ventricular short axis at papillary muscle level were recorded. Peak systolic radial strain (PRS) and circumferential strain (PCS) were measured in the mid-ventricle in short-axis view by using EchoPAC workstation. Left ventricular internal diameter at diastole (LVIDd) and systole (LVIDs), fractional shortening (FS), ejection fraction (EF) and left ventricular mass (LVM) were measured by anatomical M-model echocardiography. Infarct size was measured using triphenyl tetrazolium chloride (TTC) staining 1 week and 8 weeks after the operation. Fibrosis of left ventricu-lar myocardium was displayed using Van Gieson staining 1 week after the infarction. In terms of the TTC staining results, the left ventricle fell into three categories: infarcted, peri-infarcted and remote myocardial regions. Compared with those at baseline and in the SHAM group, (1) PRS and PCS in the infarcted, peri-infarcted and remote myocardial regions were significantly decreased in the MI group within 1 week after the operation (P〈0.05) and the low levels lasted 8 weeks; (2) Compared with those at baseline, LVIDd, LVIDs, FS, EF and LVM in the MI group showed no significant dif-ference 1 week after the operation (P〉0.05). However, LVIDd, LVIDs and LVM were increased sig-nificantly 4 and 8 weeks after the operation (P〈0.05), and FS and EF were decreased substantially (P〈0.05). Van Gieson staining showed that fibrosis developed in all the three myocardial regions to varying degrees. It is concluded that 2D-STI is non-invasive and can be used to assess regional func-tion of myocardium with different blood supply in rats following acute occlusion of the LAD, and can be used as a sensitive and reliable means to follow up the process of left ventricular remodeling. 展开更多
关键词 echocardiography ventricular function left left ventricular remodeling two-dimensional strain
下载PDF
Role of 2-dimensional Doppler echo-cardiography in screening portopulmonary hypertension in portal hypertension patients 被引量:7
17
作者 Hua, Rong Sun, Yong-Wei +4 位作者 Wu, Zhi-Yong Cheng, Wei Xu, Qing Cao, Hui Luo, Meng 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2009年第2期157-161,共5页
BACKGROUND: Portopulmonary hypertension (PPH) is difficult to recognize in the early and middle stages because it is frequently asymptomatic. As right ventricular function is impaired in patients with moderate and sev... BACKGROUND: Portopulmonary hypertension (PPH) is difficult to recognize in the early and middle stages because it is frequently asymptomatic. As right ventricular function is impaired in patients with moderate and severe PPH, any dramatic hemodynamic changes in liver transplantation or other procedures may result in death from pulmonary and cardiac events. In this study, we investigated the prevalence of PPH in patients with portal hypertension (PHT) mainly caused by hepatitis B virus, and evaluated the effect of 2-dimensional Doppler echocardiography (2D-ECHO) in screening for PPH. METHODS: One hundred and five PHT patients received transthoracic 2D-ECHO preoperatively, systolic pulmonary arterial pressure (SPAP, normal range <30 mmHg) and pulmonary acceleration time (PAT, normal range >= 120 msec) were measured to screen for PPH (positive result: SPAP >= 30 mmHg and/or PAT <100 msec). Subsequently, pulmonary hemodynamic parameters were measured by right heart catheterization (RHC) for definitive diagnosis of PPH. The results of the two methods were compared to assess the screening effect of 2D-ECHO. RESULTS: The prevalence of PPH in this study was 3.8% (4/105). About 90% (95/105) of patients had a detectable tricuspid regurgitation by 2D-ECHO and the mean SPAP was 27.7 +/- 5.9 mmHg. Twenty-two of these 95 patients had an SPAP >30 mmHg. The mean PAT of all patients was 140 23 msec and 5 were <100 msec. Twenty-two patients were screened out by 2D-ECHO and 4 were diagnosed by RHC. A positive significant correlation (r=0.55, P<0.01) was found between SPAP measured by 2D-ECHO and mean pulmonary artery pressure (MPAP) measured by RHC, and a weak but significant negative correlation (r=-0.27, P=0.005) existed between PAT and pulmonary vascular resistance (PVR). The sensitivity, specificity, agreement rate, positive predictive value and negative predictive value of the screening test were 100%, 82%, 83%, 18% and 100%, respectively. CONCLUSIONS: The prevalence of PPH in this study is lower than in Western countries. As a screening test, 2D-ECHO has very high sensitivity and negative predictive value. A negative test result can directly be used to exclude PPH, while a positive result should be confirmed by RHC. 展开更多
关键词 portopulmonary hypertension 2-dimensional Doppler echocardiography right heart catheterization PREVALENCE diagnosis
下载PDF
Numerical study on three-dimensional flow field of continuously rotating detonation in a toroidal chamber 被引量:4
18
作者 Xu-Dong Zhang Bao-Chun Fan +2 位作者 Ming-Yue Gui Zhen-Hua Pan Gang Dong 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第1期66-72,共7页
Gaseous detonation propagating in a toroidal chamber was numerically studied for hydrogen/oxygen/nitrogen mixtures. The numerical method used is based on the three-dimensional Euler equations with detailed finiterate ... Gaseous detonation propagating in a toroidal chamber was numerically studied for hydrogen/oxygen/nitrogen mixtures. The numerical method used is based on the three-dimensional Euler equations with detailed finiterate chemistry. The results show that the calculated streak picture is in qualitative agreement with the picture recorded by a high speed streak camera from published literature. The three-dimensional flow field induced by a continuously rotating detonation was visualized and distinctive features of the rotating detonations were clearly depicted. Owing to the unconfined character of detonation wavelet, a deficit of detonation parameters was observed. Due to the effects of wall geometries, the strength of the outside detonation front is stronger than that of the inside portion. The detonation thus propagates with a constant circular velocity. Numerical simulation also shows three-dimensional rotating detonation structures, which display specific feature of the detonation- shock combined wave. Discrete burning gas pockets are formed due to instability of the discontinuity. It is believed that the present study could give an insight into the interest- ing properties of the continuously rotating detonation, and is thus beneficial to the design of continuous detonation propulsion systems. 展开更多
关键词 Continuously rotating detonation - Three- dimensional flow field structure - Numerical study Detonation parameters deficit ~ Effects of wall geometries
下载PDF
实时三维超声心动图与二维斑点追踪技术对PD-1免疫抑制剂诱发早期心肌损伤的评估
19
作者 宋焱 耿峰 +2 位作者 宛新安 李霞 章春泉 《齐齐哈尔医学院学报》 2024年第4期348-352,共5页
目的 应用实时三维超声心动图(RT-3DE)与二维斑点追踪技术(2D-STI)评估PD-1/PD-L1免疫检查点抑制剂(ICIs)治疗期间患者左室收缩功能变化,探讨其在评估ICIs诱发早期心肌损伤中的应用价值。方法 选择2021年3月—2022年9月在本院接受ICIs... 目的 应用实时三维超声心动图(RT-3DE)与二维斑点追踪技术(2D-STI)评估PD-1/PD-L1免疫检查点抑制剂(ICIs)治疗期间患者左室收缩功能变化,探讨其在评估ICIs诱发早期心肌损伤中的应用价值。方法 选择2021年3月—2022年9月在本院接受ICIs治疗的32例肿瘤患者作为研究对象。患者在治疗前(T0)、治疗后1个周期(T1)、2个周期(T2)、3个周期(T3)、4个周期(T4)内进行实验室及经胸超声心动图检查。记录患者治疗前后心脏标记物、左心室常规超声心动图参数、RT-3DE参数变化、2D-STI参数变化。结果 在整个随访期间未观察到心脏标记物、血压、心率、心室腔大小的显著变化。从表中可以看到与T0相比,CK、CK-MB、LDH、BNP在T1~T2时有升高趋势,在T3、T4趋于稳定,差异无统计学意义(P>0.05)。所有研究对象的LVEF均>50%。与T0相比,接受PD-1抑制剂治疗后LVGLS降低,并且在T1~T3期上述变化已明显,T4时显著;T0~T4期间LVGCS差异无统计学意义(P>0.05)。T16-SD/R-R(%)、T16-Dif/R-R(%);T12-SD/R-R(%)、T12-Dif/R-R(%);T6-SD/R-R(%)、T6-Dif/R-R(%)在T1~T3期升高,T4期显著升高,差异有统计学意义(P<0.001)。STI联合RT-3DE是预测免疫抑制剂相关早期亚临床心脏毒性的最佳方法,其诊断敏感性为91.67%,特异性为85%。结论 应用二维斑点追踪与实时三维超声心动图对无明显LVEF降低的ICIs诱发早期心肌损伤具有较高的诊断价值。 展开更多
关键词 实时三维超声心动图 二维斑点追踪 PD-1免疫抑制剂 心肌损伤
下载PDF
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
20
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color Doppler flow imaging aortic regurgitation
下载PDF
上一页 1 2 104 下一页 到第
使用帮助 返回顶部