Some new concepts of effective incidence matrix,ascending order adjacency matrix andend-result vertex are introduced,and some improvements of the maximum weight matchingalgorithm are made.With this method a computer p...Some new concepts of effective incidence matrix,ascending order adjacency matrix andend-result vertex are introduced,and some improvements of the maximum weight matchingalgorithm are made.With this method a computer program in FORTRAN language is realized onthe computers FELIX C-512 and IBM-PC.Good results are obtained in practical operations.展开更多
Droplet-based electricity generators (DEGs) leveraging triboelectric effects are simple and high-performance devices for harvesting energy from ubiquitous water droplets. Instantaneous power plays a vital role in wide...Droplet-based electricity generators (DEGs) leveraging triboelectric effects are simple and high-performance devices for harvesting energy from ubiquitous water droplets. Instantaneous power plays a vital role in wide applications of DEGs. However, the governing law of the maximum instantaneous power and matching resistance is lacking and their determination suffers from heavy repetitive experiments, hindering the development of DEGs. Herein, we propose a quick evaluation method for the internal droplet impedance, instantaneous peak power, maximum instantaneous power and matching resistance which exhibits broad universality and excellent accuracy. Moreover, effects of diverse factors pertaining to droplets and devices are fully investigated, highlighting that the maximum instantaneous power and matching resistance can be effectively regulated across multiple orders of magnitudes by controlling the salt concentration. Our findings shed insights into the understanding, evaluation, and regulation of instantaneous power for DEGs, and shall promote the renovation of the DEG technology.展开更多
对于环境中存在的各种类型能量源,其往往具有不同的阻抗特性以及输出功率范围。为了提高能量收集系统的能量萃取能力,合理的接口电路设计是关键。基于此,通过对环境中光伏(Photovoltaic,PV)能量源微弱直流特性以及高效率收集和转化的研...对于环境中存在的各种类型能量源,其往往具有不同的阻抗特性以及输出功率范围。为了提高能量收集系统的能量萃取能力,合理的接口电路设计是关键。基于此,通过对环境中光伏(Photovoltaic,PV)能量源微弱直流特性以及高效率收集和转化的研究,在传统开路电压法(Open-Circuit Voltage,OCV)的基础上,结合输入电压纹波控制,提出了一种可实时最大功率点追踪(Maximum Power Point Tracking,MPPT)的预估算法。该预估算法根据能量源的输出特性,采用了分数开路电压法(Fractional Open-Circuit Voltage,FOCV),并根据纹波大小动态调节变换器的工作模式,实现阻抗匹配。为了尽可能减小因采样带来的能量损失,采用可片上全集成的较小的采样电容,并逐周期的进行开路电压采样和计算,实现了对源功率变化的高精度追踪。仿真结果表明,所提出的追踪算法能够实时监测能量源的状态,具有高的追踪速度和追踪精度,且采样时间仅需100 ns。能量源功率在1μW~10 mW范围内变化时,最短的追踪时间仅需4.37μs,追踪精度可达99.7%。展开更多
Let G be a simple graph with 2n vertices and a perfect matching.The forcing number f(G,M) of a perfect matching M of G is the smallest cardinality of a subset of M that is contained in no other perfect matching of G.A...Let G be a simple graph with 2n vertices and a perfect matching.The forcing number f(G,M) of a perfect matching M of G is the smallest cardinality of a subset of M that is contained in no other perfect matching of G.Among all perfect matchings M of G,the minimum and maximum values of f(G,M) are called the minimum and maximum forcing numbers of G,denoted by f(G) and F(G),respectively.Then f(G)≤F(G) ≤n-1.Che and Chen(2011) proposed an open problem:how to characterize the graphs G with f(G)=n-1.Later they showed that for a bipartite graph G,f(G)=n-1 if and only if G is complete bipartite graph K_(n,n).In this paper,we completely solve the problem of Che and Chen,and show that f(G)=n-1 if and only if G is a complete multipartite graph or a graph obtained from complete bipartite graph K_(n,n) by adding arbitrary edges in one partite set.For all graphs G with F(G)=n-1,we prove that the forcing spectrum of each such graph G forms an integer interval by matching 2-switches and the minimum forcing numbers of all such graphs G form an integer interval from [n/2] to n-1.展开更多
Background: The clinical significance of uric acid (UA) in patients with chronic kidney disease (CKD) has never been elucidated in detail. Objectives: The aim of this study was to elucidate the predictive value of hyp...Background: The clinical significance of uric acid (UA) in patients with chronic kidney disease (CKD) has never been elucidated in detail. Objectives: The aim of this study was to elucidate the predictive value of hyperuricemia (HU) in relation to kidney disease progression in CKD patients. Methods: We reviewed data obtained from 201 CKD patients. Renal outcome was assessed by performing the Kaplan-Meier and Cox proportional hazard regression models. The renal outcomes of CKD patients with and without HU were compared by using a propensity score-matched cohort. Results: The results of a multivariate Cox regression analysis showed that HU (UA ≥ 7.1 mg/dL) (P = 0.001), diabetes mellitus (P = 0.003), and a high urine albumin-to-creatinine ratio (P = 0.0005) were significantly associated with a ≥50% eGFR decline or ESRD. The serum UA values were positively correlated with mean blood pressure (P = 0.007), visceral fat area (P = 0.0003), and maximum carotid intima-media thickness (P = 0.0003). The Kaplan-Meier analysis in the propensity score-matched cohort indicated that the renal survival rate of the group of CKD patients with HU was significantly lower than that of the group without HU (log rank, P Conclusion: The results of this study suggest that the serum UA value is a predictor of CKD progression.展开更多
In this paper,average bit error probability(ABEP)bound of optimal maximum likelihood(ML)detector is first derived for ultra massive(UM)multiple-input-multiple-output(MIMO)system with generalized amplitude phase modula...In this paper,average bit error probability(ABEP)bound of optimal maximum likelihood(ML)detector is first derived for ultra massive(UM)multiple-input-multiple-output(MIMO)system with generalized amplitude phase modulation(APM),which is confirmed by simulation results.Furthermore,a minimum residual criterion(MRC)based lowcomplexity near-optimal ML detector is proposed for UM-MIMO system.Specifically,we first obtain an initial estimated signal by a conventional detector,i.e.,matched filter(MF),or minimum mean square error(MMSE)and so on.Furthermore,MRC based error correction mechanism(ECM)is proposed to correct the erroneous symbol encountered in the initial result.Simulation results are shown that the performance of the proposed MRC-ECM based detector is capable of approaching theoretical ABEP of ML,despite only imposing a slightly higher complexity than that of the initial detector.展开更多
文摘Some new concepts of effective incidence matrix,ascending order adjacency matrix andend-result vertex are introduced,and some improvements of the maximum weight matchingalgorithm are made.With this method a computer program in FORTRAN language is realized onthe computers FELIX C-512 and IBM-PC.Good results are obtained in practical operations.
基金financial support from the China Postdoctoral Science Foundation(No.2023TQ0210)the Postdoctoral Fellowship Program of CPSF(No.GZB20230403)+1 种基金the Fundamental Research Funds for the Central Universities(Shanghai Jiao Tong University)the Innovative Research Groups of the National Natural Science Foundation of China(No.51521004)。
文摘Droplet-based electricity generators (DEGs) leveraging triboelectric effects are simple and high-performance devices for harvesting energy from ubiquitous water droplets. Instantaneous power plays a vital role in wide applications of DEGs. However, the governing law of the maximum instantaneous power and matching resistance is lacking and their determination suffers from heavy repetitive experiments, hindering the development of DEGs. Herein, we propose a quick evaluation method for the internal droplet impedance, instantaneous peak power, maximum instantaneous power and matching resistance which exhibits broad universality and excellent accuracy. Moreover, effects of diverse factors pertaining to droplets and devices are fully investigated, highlighting that the maximum instantaneous power and matching resistance can be effectively regulated across multiple orders of magnitudes by controlling the salt concentration. Our findings shed insights into the understanding, evaluation, and regulation of instantaneous power for DEGs, and shall promote the renovation of the DEG technology.
文摘对于环境中存在的各种类型能量源,其往往具有不同的阻抗特性以及输出功率范围。为了提高能量收集系统的能量萃取能力,合理的接口电路设计是关键。基于此,通过对环境中光伏(Photovoltaic,PV)能量源微弱直流特性以及高效率收集和转化的研究,在传统开路电压法(Open-Circuit Voltage,OCV)的基础上,结合输入电压纹波控制,提出了一种可实时最大功率点追踪(Maximum Power Point Tracking,MPPT)的预估算法。该预估算法根据能量源的输出特性,采用了分数开路电压法(Fractional Open-Circuit Voltage,FOCV),并根据纹波大小动态调节变换器的工作模式,实现阻抗匹配。为了尽可能减小因采样带来的能量损失,采用可片上全集成的较小的采样电容,并逐周期的进行开路电压采样和计算,实现了对源功率变化的高精度追踪。仿真结果表明,所提出的追踪算法能够实时监测能量源的状态,具有高的追踪速度和追踪精度,且采样时间仅需100 ns。能量源功率在1μW~10 mW范围内变化时,最短的追踪时间仅需4.37μs,追踪精度可达99.7%。
基金Supported by National Natural Science Foundation of China (Grant No. 12271229)Gansu Provincial Department of Education:Youth Doctoral fund project (Grant No. 2021QB-090)。
文摘Let G be a simple graph with 2n vertices and a perfect matching.The forcing number f(G,M) of a perfect matching M of G is the smallest cardinality of a subset of M that is contained in no other perfect matching of G.Among all perfect matchings M of G,the minimum and maximum values of f(G,M) are called the minimum and maximum forcing numbers of G,denoted by f(G) and F(G),respectively.Then f(G)≤F(G) ≤n-1.Che and Chen(2011) proposed an open problem:how to characterize the graphs G with f(G)=n-1.Later they showed that for a bipartite graph G,f(G)=n-1 if and only if G is complete bipartite graph K_(n,n).In this paper,we completely solve the problem of Che and Chen,and show that f(G)=n-1 if and only if G is a complete multipartite graph or a graph obtained from complete bipartite graph K_(n,n) by adding arbitrary edges in one partite set.For all graphs G with F(G)=n-1,we prove that the forcing spectrum of each such graph G forms an integer interval by matching 2-switches and the minimum forcing numbers of all such graphs G form an integer interval from [n/2] to n-1.
文摘Background: The clinical significance of uric acid (UA) in patients with chronic kidney disease (CKD) has never been elucidated in detail. Objectives: The aim of this study was to elucidate the predictive value of hyperuricemia (HU) in relation to kidney disease progression in CKD patients. Methods: We reviewed data obtained from 201 CKD patients. Renal outcome was assessed by performing the Kaplan-Meier and Cox proportional hazard regression models. The renal outcomes of CKD patients with and without HU were compared by using a propensity score-matched cohort. Results: The results of a multivariate Cox regression analysis showed that HU (UA ≥ 7.1 mg/dL) (P = 0.001), diabetes mellitus (P = 0.003), and a high urine albumin-to-creatinine ratio (P = 0.0005) were significantly associated with a ≥50% eGFR decline or ESRD. The serum UA values were positively correlated with mean blood pressure (P = 0.007), visceral fat area (P = 0.0003), and maximum carotid intima-media thickness (P = 0.0003). The Kaplan-Meier analysis in the propensity score-matched cohort indicated that the renal survival rate of the group of CKD patients with HU was significantly lower than that of the group without HU (log rank, P Conclusion: The results of this study suggest that the serum UA value is a predictor of CKD progression.
基金supported in part by the National Key Research and Development Program of China under Grant 2019YFB1803400in part by the National Science Foundation of China under Grant 62001179in part by the Fundamental Research Funds for the Central Universities under Grant 2020kfyXJJS111.
文摘In this paper,average bit error probability(ABEP)bound of optimal maximum likelihood(ML)detector is first derived for ultra massive(UM)multiple-input-multiple-output(MIMO)system with generalized amplitude phase modulation(APM),which is confirmed by simulation results.Furthermore,a minimum residual criterion(MRC)based lowcomplexity near-optimal ML detector is proposed for UM-MIMO system.Specifically,we first obtain an initial estimated signal by a conventional detector,i.e.,matched filter(MF),or minimum mean square error(MMSE)and so on.Furthermore,MRC based error correction mechanism(ECM)is proposed to correct the erroneous symbol encountered in the initial result.Simulation results are shown that the performance of the proposed MRC-ECM based detector is capable of approaching theoretical ABEP of ML,despite only imposing a slightly higher complexity than that of the initial detector.