On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and an...On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.展开更多
Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on th...Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.展开更多
In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and hea...In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.展开更多
In this research,the thermal performance of a single U-tube vertical ground heat exchanger is evaluated numerically as a function of the most influential flow parameters,namely,the soil porosity,volumetric heat capaci...In this research,the thermal performance of a single U-tube vertical ground heat exchanger is evaluated numerically as a function of the most influential flow parameters,namely,the soil porosity,volumetric heat capacity,and thermal conductivity of the backfill material,inlet volume flow rate,and inlet fluid temperature.The results are discussed in terms of the variations of the heat exchange rate,the effective thermal resistance,and the effectiveness of the ground heat exchanger.They show that the inlet volume flow rate,inlet fluid temperature,and backfill material thermal conductivity have significant effects on the thermal performance of the ground heat exchanger,such that by decreasing the inlet volume flow rate and increasing the backfill material thermal conductivity and inlet fluid temperature,the outlet fluid temperature decreases considerably.On the contrary,the soil porosity and backfill material volumetric heat capacity have negligible effects on the studied ground heat exchanger’s thermal performance.The lowest inlet fluid temperature reaches a the maximum effective thermal resistance of borehole and soil,and consequently the minimum heat transfer rate and effectiveness.Also,multilinear regression analyses are performed to determine the most feasible models able to predict the thermal properties of the single U-tube ground heat exchanger.展开更多
An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat trans...An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%.展开更多
System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are les...System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are less prone to leakages than the all-glass or the heat pipe types. U-tube solar water heaters suspended on walls and balconies could help overcome present day roof space restriction and increasing apartment-style housing. As such, their performance would depend upon its orientation when mounted in a vertical position. This paper reports the results of outdoor tests conducted on natural convection U-tube solar water heaters oriented towards different directions. Long and short term test procedures were employed to allow us to compare their performances as if they were tested simultaneously side-by-side.展开更多
Refrigeration challenges in regions with electricity shortages significantly decrease the quality of life for residents. In response to the prevalent refrigeration challenges in power-deficient areas, a novel distribu...Refrigeration challenges in regions with electricity shortages significantly decrease the quality of life for residents. In response to the prevalent refrigeration challenges in power-deficient areas, a novel distributed solar refrigeration system, comprising an evacuated U-tube solar collector and elastocaloric refrigerator, is theoretically introduced. Theoretical formulations for the energy efficiency and cooling power of the solar refrigeration system are presented to facilitate predictive assessments of the performance properties. Under typical conditions, the energy efficiency and cooling power of the solar refrigeration system are,respectively, 4.84% and 200.15 W. Subsequently, an extensive parameter study is conducted to comprehensively uncover key performance influencers and identify avenues for improvement. In addition, local sensitivity analyses identify that the length ratio is the top influential parameter, while the heat transfer fluid flow rate is the least sensitivity. A pragmatic case study,conducted with the weather data of Ningbo City, China, serves to empirically predict the performance of the hybrid system within the constraints of practical circumstances.展开更多
Harvesting ambient mechanical energy is a key technology for realizing self-powered electronics. With advantages of stability and durabilid, a liquid-solid-based triboelectric nanogenerator (TENG) has recently drawn...Harvesting ambient mechanical energy is a key technology for realizing self-powered electronics. With advantages of stability and durabilid, a liquid-solid-based triboelectric nanogenerator (TENG) has recently drawn much attention. However, the impacts of liquid properties on the TENG performance and the related working principle are still unclear. We assembled herein a U-tube TENG based on the liquid-solid mode and applied 11 liquids to study the effects of liquid properties on the TENG output performance. The results confirmed that the key factors influencing the output are polarity, dielectric constant, and affinity to fluorinated ethylene propylene (FEP). Among the 11 liquids, the pure water-based U-tube TENG exhibited the best output with an open-circuit voltage (Voc) of 81.7 V and a short-circuit current (Isc) of 0.26 μA for the shaking mode (0.5 Hz), which can further increase to 93.0 V and 0.48 μA, respectively, for the horizontal shifting mode (1.25 Hz). The U-tube TENG can be utilized as a self-powered concentration sensor (component concentration or metal ion concentration) for an aqueous solution with an accuracy higher than 92%. Finally, an upgraded sandwich-like water-FEP U-tube TENG was applied to harvest water-wave energy, showing a high output with Voc of 350 V, Isc of 1.75 μA, and power density of 2.04 W/m3. We successfully lighted up 60 LEDs and powered a temperature-humidity meter. Given its high output performance, the water-FEP U-tube TENG is a very promising approach for harvesting water-wave energy for self-powered electronics.展开更多
文摘On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.
基金Project(CSTC 2004AA7008 2 2) supported by Key Technologies for Development of Small Cities of ChongqingMunicipality
文摘Heat exchange performance of vertical U-tube heat exchanger was studied with two different borehole fill materials and CFD software. Borehole surface temperature and water temperature distribution were simulated on the condition of continuous operation for 8 h in winter with inlet water temperature being 10℃. The results show that there is no obvious difference on heat exchanger performance between the two different borehole fill materials.
基金Projects(2011BAJ03B12-3,2013BAJ10B02-03) supported by the National Science and Technology Program during the 12th Five-year Plan Period,ChinaProject(51378005) supported by the National Natural Science Foundation,China+1 种基金Projects(DUT14RC(3)123,DUT14RC(3)129) supported by Fundamental Research Funds for the Dalian University of Tecnology,ChinaProject(DUT14ZD210) supported by the Fundamental Research Funds for the Central Universities of China
文摘In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube(HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little.Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.
文摘In this research,the thermal performance of a single U-tube vertical ground heat exchanger is evaluated numerically as a function of the most influential flow parameters,namely,the soil porosity,volumetric heat capacity,and thermal conductivity of the backfill material,inlet volume flow rate,and inlet fluid temperature.The results are discussed in terms of the variations of the heat exchange rate,the effective thermal resistance,and the effectiveness of the ground heat exchanger.They show that the inlet volume flow rate,inlet fluid temperature,and backfill material thermal conductivity have significant effects on the thermal performance of the ground heat exchanger,such that by decreasing the inlet volume flow rate and increasing the backfill material thermal conductivity and inlet fluid temperature,the outlet fluid temperature decreases considerably.On the contrary,the soil porosity and backfill material volumetric heat capacity have negligible effects on the studied ground heat exchanger’s thermal performance.The lowest inlet fluid temperature reaches a the maximum effective thermal resistance of borehole and soil,and consequently the minimum heat transfer rate and effectiveness.Also,multilinear regression analyses are performed to determine the most feasible models able to predict the thermal properties of the single U-tube ground heat exchanger.
文摘An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%.
文摘System performance of solar water heaters depends upon collector and storage tank designs, solar radiation intensity and ambient temperature, amongst others. Evacuated glass tube collectors with U-tubes inside are less prone to leakages than the all-glass or the heat pipe types. U-tube solar water heaters suspended on walls and balconies could help overcome present day roof space restriction and increasing apartment-style housing. As such, their performance would depend upon its orientation when mounted in a vertical position. This paper reports the results of outdoor tests conducted on natural convection U-tube solar water heaters oriented towards different directions. Long and short term test procedures were employed to allow us to compare their performances as if they were tested simultaneously side-by-side.
基金supported by the Baima Lake Laboratory Joint Funds of the Zhejiang Natural Science Foundation of China(Grant No.LBMHY24E060010)。
文摘Refrigeration challenges in regions with electricity shortages significantly decrease the quality of life for residents. In response to the prevalent refrigeration challenges in power-deficient areas, a novel distributed solar refrigeration system, comprising an evacuated U-tube solar collector and elastocaloric refrigerator, is theoretically introduced. Theoretical formulations for the energy efficiency and cooling power of the solar refrigeration system are presented to facilitate predictive assessments of the performance properties. Under typical conditions, the energy efficiency and cooling power of the solar refrigeration system are,respectively, 4.84% and 200.15 W. Subsequently, an extensive parameter study is conducted to comprehensively uncover key performance influencers and identify avenues for improvement. In addition, local sensitivity analyses identify that the length ratio is the top influential parameter, while the heat transfer fluid flow rate is the least sensitivity. A pragmatic case study,conducted with the weather data of Ningbo City, China, serves to empirically predict the performance of the hybrid system within the constraints of practical circumstances.
文摘Harvesting ambient mechanical energy is a key technology for realizing self-powered electronics. With advantages of stability and durabilid, a liquid-solid-based triboelectric nanogenerator (TENG) has recently drawn much attention. However, the impacts of liquid properties on the TENG performance and the related working principle are still unclear. We assembled herein a U-tube TENG based on the liquid-solid mode and applied 11 liquids to study the effects of liquid properties on the TENG output performance. The results confirmed that the key factors influencing the output are polarity, dielectric constant, and affinity to fluorinated ethylene propylene (FEP). Among the 11 liquids, the pure water-based U-tube TENG exhibited the best output with an open-circuit voltage (Voc) of 81.7 V and a short-circuit current (Isc) of 0.26 μA for the shaking mode (0.5 Hz), which can further increase to 93.0 V and 0.48 μA, respectively, for the horizontal shifting mode (1.25 Hz). The U-tube TENG can be utilized as a self-powered concentration sensor (component concentration or metal ion concentration) for an aqueous solution with an accuracy higher than 92%. Finally, an upgraded sandwich-like water-FEP U-tube TENG was applied to harvest water-wave energy, showing a high output with Voc of 350 V, Isc of 1.75 μA, and power density of 2.04 W/m3. We successfully lighted up 60 LEDs and powered a temperature-humidity meter. Given its high output performance, the water-FEP U-tube TENG is a very promising approach for harvesting water-wave energy for self-powered electronics.