Fracture behavior is one of the most important,yet still little understood properties of ultra-high performance cementitious composites(UHPCC),a new marine structural engineering material. Research on the fracture and...Fracture behavior is one of the most important,yet still little understood properties of ultra-high performance cementitious composites(UHPCC),a new marine structural engineering material. Research on the fracture and direct tension behavior of UHPCC was carried out.The constitution law of UHPCC was divided into three phases:pre-partial debonding,partial debonding,and pullout phases.A direct tension constitution law was constructed based on the proposed fiber reinforcing parameter as a function of fiber volume fraction,fiber diameter and length,and fiber bonding strength.With the definition of linear crack shape,the energy release rate of UHPCC was derived and the R-curve equation was calculated from this.Loading tests of UHPCC using a three-point bending beam with an initial notch were carried out.The predictions from the proposed R-curve were in good agreement with the test results, indicating that the proposed R-curve accurately describes the fracture resistance of UHPCC.Introduction of a fiber reinforcement parameter bridges the fracture property R-curve and micro-composites’ mechanics parameters together.This has laid the foundation for further research into fracture properties based on micro-mechanics.The proposed tension constitution law and R-curve can be references for future UHPCC fracture evaluation.展开更多
This study intends to find out the correlation between the cover depth and the bond characteristics of UHPC through pull-out tests of UHPC specimens with different cover depths and bond tests of rebar using flexural m...This study intends to find out the correlation between the cover depth and the bond characteristics of UHPC through pull-out tests of UHPC specimens with different cover depths and bond tests of rebar using flexural members. In this experimental study, specimens are fabricated with the lap-splice length as test variable in relation with the calculation of the lap-splice length for 180- MPa UHPC. Moreover, specimens are also fabricated with the cover depth as test variable to evaluate the effect of the cover depth on the UHPC flexural members. The load-displacement curves are analyzed for each of these test variables to compute the lap-splice length proposed in the K-UHPC structural design guideline and to evaluate the influence of the cover depth on the flexural members. As a result, the stability of the structural behavior can be significantly enhanced by increasing slightly the cover depth specification of the current UHPC Structure Design Guideline from the maximum value between 1.5 times of rebar diameter and 20 mm to the maximum value between 1.5 times of rebar diameter and 25 mm.展开更多
[Objectives] An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established for simultaneous determination of 26 antibiotics in the water around landfills. [Methods] After an H...[Objectives] An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established for simultaneous determination of 26 antibiotics in the water around landfills. [Methods] After an HLB solid-phase extraction column was activated, and a water sample, which was adjusted with phosphoric acid to a pH of (2±0.5) and added with 500 mg of disodium EDTA, was loaded, and 5 ml of water and 20% methanol water was added for washing. Next, 10 ml of elution solution was added for elution, and the collected eluate was evaporated under reduced pressure at 40 ℃ to near dryness, and 1 ml of reconstitution solution was added to a constant volume. An ACQUITY UPLC BEH C18 (100 mm×2.1 mm, 2.6 μm) chromatographic column was adopted for LC separation by gradient elution with 0.1% formic acid aqueous solution-acetonitrile as the mobile phase. For MS detection, the MRM mode was adopted for collection, and the positive and negative ion modes were switched for simultaneous determination, and the internal standard method was used for quantification. [Results] The correlation coefficient R2 was greater than 0.99 in the linear range of each target substance. The limits of detection ranged from 0.15 to 3.00 ng/L, and the limits of quantitation were between 0.80 and 10.00 ng/L, and the recoveries ranged from 77.9% to 104.85%. [Conclusions] The method has high sensitivity, good accuracy and strong practical value.展开更多
Objective To establish a comprehensive analytical method based on SPE‐UPLC‐MS for the simultaneous determination of bisphenol A (BPA), nonylphenol (NP), and octylphenol (OP) in urine samples. Methods Sixty uri...Objective To establish a comprehensive analytical method based on SPE‐UPLC‐MS for the simultaneous determination of bisphenol A (BPA), nonylphenol (NP), and octylphenol (OP) in urine samples. Methods Sixty urine samples collected from healthy subjects were analyzed for BPA, NP, and OP concentrations. The samples were de‐conjugated by adding β‐glucuronidase and sulfatase. After the enzymatic treatment, the samples were subjected to the OASIS HLB column solid phase extraction cartridges so as to be cleaned and concentrated. The UPLC separation was performed on a Acquity UPLCTM BEH C18 column (2.1×100 mm, 1.7 μm) with a gradient elution system of methanol‐water as the mobile phase. Triple‐quadrupole mass spectrometry analyzer was used for the qualitative and quantitative analysis of UPLC‐MS/MS system. Results The limit of detection of BPA, NP, and OP was 0.10, 0.10, and 0.15 ng/mL, respectively. The recoveries of BPA, NP and OP were 80.1%‐108%, 81.3%‐109%, and 81.5%‐98.7%, respectively. Among the 60 urine samples, BPA was detected in 8 samples at the level of 0.297‐32.7ng/mL, NP was detected in 29 samples at the level of 1.69‐27.8 ng/mL, and OP was detected in 17 samples at the level of 0.407‐11.1 ng/mL. Conclusion The method is simple with high sensitivity and selectivity, and is suitable for the determination of BPA, NP, and OP in urine. As shown by our analysis , BPA, NP, and OP appear to be prevalent in human urine. This is particularly true for NP. The results from our study is therefore valuable for future studies to assess the exposure to BPA, NP, and OP in the general population.展开更多
In recent times, the overall interest over Supercritical Fluid Chromatography (SFC) is truly growing within various domains but especially for pharmaceutical analysis. However, in the best of our knowledge modern SFC ...In recent times, the overall interest over Supercritical Fluid Chromatography (SFC) is truly growing within various domains but especially for pharmaceutical analysis. However, in the best of our knowledge modern SFC is not yet applied for drug quality control in the daily routine framework. Among the numerous reported SFC methods, none of them could be found to fully satisfy to all steps of the analytical method lifecycle. Thereby, the present contribution aims to provide an overview of the current and past achievements related to SFC techniques, with a targeted attention to this lifecycle and its successive steps. The included discussions were therefore structured accordingly and emphasizing the analytical method lifecycle in accord with the International Conference on Harmonisation (ICH). Recent and important scientific outputs in the field of analytical SFC, as well as instrumental evolution, qualification strategies, method development methodologies and discussions on the topic of method validation are reviewed.展开更多
The thixotropic structural build-up is crucial in extrusion-based three-dimensional(3D)concrete printing.This paper uses a theoretical model to predict the evolution of static and dynamic yield stress for printed conc...The thixotropic structural build-up is crucial in extrusion-based three-dimensional(3D)concrete printing.This paper uses a theoretical model to predict the evolution of static and dynamic yield stress for printed concrete.The model employs a structural kinetics framework to create a time-independent constitutive link between shear stress and shear rate.The model considers flocculation,deflocculation,and chemical hydration to anticipate structural buildability.The reversible and irreversible contributions that occur throughout the build-up,breakdown,and hydration are defined based on the proposed structural parameters.Additionally,detailed parametric studies are conducted to evaluate the impact of model parameters.It is revealed that the proposed model is in good agreement with the experimental results,and it effectively characterizes the structural build-up of 3D printable concrete.展开更多
基金the Center of Concrete Corea,Korea Development and Application of High Performance and Multi-Function Concrete(05-CCT-D11)
文摘Fracture behavior is one of the most important,yet still little understood properties of ultra-high performance cementitious composites(UHPCC),a new marine structural engineering material. Research on the fracture and direct tension behavior of UHPCC was carried out.The constitution law of UHPCC was divided into three phases:pre-partial debonding,partial debonding,and pullout phases.A direct tension constitution law was constructed based on the proposed fiber reinforcing parameter as a function of fiber volume fraction,fiber diameter and length,and fiber bonding strength.With the definition of linear crack shape,the energy release rate of UHPCC was derived and the R-curve equation was calculated from this.Loading tests of UHPCC using a three-point bending beam with an initial notch were carried out.The predictions from the proposed R-curve were in good agreement with the test results, indicating that the proposed R-curve accurately describes the fracture resistance of UHPCC.Introduction of a fiber reinforcement parameter bridges the fracture property R-curve and micro-composites’ mechanics parameters together.This has laid the foundation for further research into fracture properties based on micro-mechanics.The proposed tension constitution law and R-curve can be references for future UHPCC fracture evaluation.
文摘This study intends to find out the correlation between the cover depth and the bond characteristics of UHPC through pull-out tests of UHPC specimens with different cover depths and bond tests of rebar using flexural members. In this experimental study, specimens are fabricated with the lap-splice length as test variable in relation with the calculation of the lap-splice length for 180- MPa UHPC. Moreover, specimens are also fabricated with the cover depth as test variable to evaluate the effect of the cover depth on the UHPC flexural members. The load-displacement curves are analyzed for each of these test variables to compute the lap-splice length proposed in the K-UHPC structural design guideline and to evaluate the influence of the cover depth on the flexural members. As a result, the stability of the structural behavior can be significantly enhanced by increasing slightly the cover depth specification of the current UHPC Structure Design Guideline from the maximum value between 1.5 times of rebar diameter and 20 mm to the maximum value between 1.5 times of rebar diameter and 25 mm.
基金Supported by Tongren Science and Technology Planning Project(TSKY[2022]42)Science Planning Project of Department of Education of Guizhou Province(2023B111)。
文摘[Objectives] An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established for simultaneous determination of 26 antibiotics in the water around landfills. [Methods] After an HLB solid-phase extraction column was activated, and a water sample, which was adjusted with phosphoric acid to a pH of (2±0.5) and added with 500 mg of disodium EDTA, was loaded, and 5 ml of water and 20% methanol water was added for washing. Next, 10 ml of elution solution was added for elution, and the collected eluate was evaporated under reduced pressure at 40 ℃ to near dryness, and 1 ml of reconstitution solution was added to a constant volume. An ACQUITY UPLC BEH C18 (100 mm×2.1 mm, 2.6 μm) chromatographic column was adopted for LC separation by gradient elution with 0.1% formic acid aqueous solution-acetonitrile as the mobile phase. For MS detection, the MRM mode was adopted for collection, and the positive and negative ion modes were switched for simultaneous determination, and the internal standard method was used for quantification. [Results] The correlation coefficient R2 was greater than 0.99 in the linear range of each target substance. The limits of detection ranged from 0.15 to 3.00 ng/L, and the limits of quantitation were between 0.80 and 10.00 ng/L, and the recoveries ranged from 77.9% to 104.85%. [Conclusions] The method has high sensitivity, good accuracy and strong practical value.
基金supported by the National Science and Technology Fundation as par of the Key Technologies of Food Safety Project. Chemical pollutants exposure assessment technology research(2006BAK02A01)
文摘Objective To establish a comprehensive analytical method based on SPE‐UPLC‐MS for the simultaneous determination of bisphenol A (BPA), nonylphenol (NP), and octylphenol (OP) in urine samples. Methods Sixty urine samples collected from healthy subjects were analyzed for BPA, NP, and OP concentrations. The samples were de‐conjugated by adding β‐glucuronidase and sulfatase. After the enzymatic treatment, the samples were subjected to the OASIS HLB column solid phase extraction cartridges so as to be cleaned and concentrated. The UPLC separation was performed on a Acquity UPLCTM BEH C18 column (2.1×100 mm, 1.7 μm) with a gradient elution system of methanol‐water as the mobile phase. Triple‐quadrupole mass spectrometry analyzer was used for the qualitative and quantitative analysis of UPLC‐MS/MS system. Results The limit of detection of BPA, NP, and OP was 0.10, 0.10, and 0.15 ng/mL, respectively. The recoveries of BPA, NP and OP were 80.1%‐108%, 81.3%‐109%, and 81.5%‐98.7%, respectively. Among the 60 urine samples, BPA was detected in 8 samples at the level of 0.297‐32.7ng/mL, NP was detected in 29 samples at the level of 1.69‐27.8 ng/mL, and OP was detected in 17 samples at the level of 0.407‐11.1 ng/mL. Conclusion The method is simple with high sensitivity and selectivity, and is suitable for the determination of BPA, NP, and OP in urine. As shown by our analysis , BPA, NP, and OP appear to be prevalent in human urine. This is particularly true for NP. The results from our study is therefore valuable for future studies to assess the exposure to BPA, NP, and OP in the general population.
文摘In recent times, the overall interest over Supercritical Fluid Chromatography (SFC) is truly growing within various domains but especially for pharmaceutical analysis. However, in the best of our knowledge modern SFC is not yet applied for drug quality control in the daily routine framework. Among the numerous reported SFC methods, none of them could be found to fully satisfy to all steps of the analytical method lifecycle. Thereby, the present contribution aims to provide an overview of the current and past achievements related to SFC techniques, with a targeted attention to this lifecycle and its successive steps. The included discussions were therefore structured accordingly and emphasizing the analytical method lifecycle in accord with the International Conference on Harmonisation (ICH). Recent and important scientific outputs in the field of analytical SFC, as well as instrumental evolution, qualification strategies, method development methodologies and discussions on the topic of method validation are reviewed.
基金A grant from CSIR,New Delhi,generously funds this studypartially supported by the City University of Hong Kong,China(No.9610661).
文摘The thixotropic structural build-up is crucial in extrusion-based three-dimensional(3D)concrete printing.This paper uses a theoretical model to predict the evolution of static and dynamic yield stress for printed concrete.The model employs a structural kinetics framework to create a time-independent constitutive link between shear stress and shear rate.The model considers flocculation,deflocculation,and chemical hydration to anticipate structural buildability.The reversible and irreversible contributions that occur throughout the build-up,breakdown,and hydration are defined based on the proposed structural parameters.Additionally,detailed parametric studies are conducted to evaluate the impact of model parameters.It is revealed that the proposed model is in good agreement with the experimental results,and it effectively characterizes the structural build-up of 3D printable concrete.