期刊文献+
共找到27,332篇文章
< 1 2 250 >
每页显示 20 50 100
Dimension-Enhanced Ultra-High Performance Liquid Chromatography/Ion Mobility-Quadrupole Time-of-Flight Mass Spectrometry Combined with Intelligent Peak Annotation for the Rapid Characterization of the Multiple Components from Seeds of Descurainia sophia 被引量:1
1
作者 Simiao Wang Xue Li +7 位作者 Boxue Chen Shitong Li Jiali Wang Jing Wang Mingshuo Yang Xiaoyan Xu Hongda Wang Wenzhi Yang 《Phyton-International Journal of Experimental Botany》 SCIE 2022年第3期541-567,共27页
The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a co... The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS. 展开更多
关键词 Descurainia sophia multicomponent characterization ultra-high performance liquid chromatography ion mobility/quadrupole time-of-flight mass spectrometry high-definition MS^(E) flavonoid
下载PDF
Rapid Quantitative Determination of Isoprene Monomer in Living Taraxacum kok-saghyz by Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry
2
作者 Xiang Tong Guo Tianyang +5 位作者 Zhang Xi Chen Yunhan Dong Yiyang Zhang Jichuan Ma Qiang Zhang Liqun 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2020年第2期30-36,共7页
Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In t... Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In this paper,a rapid and quantitative ultra-high performance liquid chromatography tandem mass spectrometry(UHPLCMS/MS)method was established for determination of macromolecular biosynthesis substrate(dimethylallyl pyrophosphate,DMAPP)and initiator(farnesyl pyrophosphate,FPP)contained in TKS.A Kromasil C18 chromatographic column was used for separation,and the multi-reaction monitoring mode(MRM)of triple quadrupole mass spectrometry was used for detection.Quantification was performed by external calibration method.The results showed that the limit of detection(LOD)and the limit of quantitation(LOQ)of DMAPP were 2.42μg/L and 7.26μg/L,respectively,and the LOQ and the LOD of FPP were 1.02μg/L and 3.05μg/L,respectively.At a concentration of 1—1000μg/L,both analytes had good determination coefficients(>0.999)of calibration curve.The recoveries of DMAPP and FPP were between 99.0%and 117.1%.In real samples detection,the contents of DMAPP and FPP in TKS samples were between 23.32—82.77μg/L and 12.03—85.67μg/L,respectively.Thus,this approach is a reliable method to quantify DMAPP and FPP in TKS. 展开更多
关键词 QUANTITATION Taraxacum kok-saghyz(TKS) ISOPRENOIDS ultra-high performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS) natural rubber(NR)
下载PDF
Determination of 19 polyphenolic compounds in tea by ultra-high performance liquid chromatography combined with quadrupole-time of flight mass spectrometry
3
作者 Jian Li Junmei Ma +1 位作者 Yan Zhang Lei Zheng 《Food Science and Human Wellness》 SCIE 2022年第3期719-726,共8页
A rapid method was presented for the determination of 19 polyphenols in tea by ultra-high performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry(UPLC-Q-TOF MS).Tea samples were extr... A rapid method was presented for the determination of 19 polyphenols in tea by ultra-high performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry(UPLC-Q-TOF MS).Tea samples were extracted by 50%(V/V)ethanol,then separated by Waters Acquity BEH C18 column using a binary solvent system composed of acetonitrile and water(0.1%formic acid)by gradient elution.The analytes were determined by Q-TOF MS in TOF MS and information dependent acquisition(IDA)-MS/MS mode.The results showed that mass accuracy error of the 19 polyphenols were lower than 5.0×10^(-6),good linear relationship was got in range of 0.2–500μg/L and correlation coefficient was higher than 0.9990.The LOD was in the range of 0.002–0.100 mg/kg and the LOQ was in the range of 0.004–0.200 mg/kg.Recovery of the method was in range of 78.4%–109.2%with spike levels of 0.004–2.000 mg/kg,relative standard deviations were lower than 10%.The method was simple,rapid and accurate.It could be used for the rapid screening and quantitative analysis of 19 polyphenols in tea. 展开更多
关键词 ultra-high performance liquid chromatography Quadrupole-time of flight mass spectrometry TEA POLYPHENOLS
下载PDF
An Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Quantification of Vancomycin Requiring Only 2 μL of Rabbit Serum
4
作者 Veronika Schmitt Andras Szeitz +1 位作者 Tara L.Klassen Urs O.Hafeli 《American Journal of Analytical Chemistry》 2017年第9期553-563,共11页
A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis,... A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis, 2 μL rabbit serum was precipitated with methanol that contained the internal standard teicoplanin (TEI). The supernatant was transferred into a 384 well-plate, diluted with water, covered with a pierceable silicone mat and 5 μL was analyzed in positive ionization mode. The UHPLC-MS/MS consisted of an Agilent 1290 Infinity UHPLC system connected to an AB Sciex QTrap&reg;5500 hybrid linear ion-trap triple quadrupole mass spectrometer equipped with a Turbo Spray source. Chromatographic separation was achieved using a Waters Acquity UPLC BEH C18 (1.7 μm, 2.1 mm × 100 mm) column, a VanGuard (1.7 μm, 2.1 × 5 mm) guard column and a mobile phase of water and methanol both containing 5 mM ammonium acetate with 0.1% formic acid. VAN was quantified with multiple reaction monitoring using the transitions of m/z 725.5/144.2, and TEI was monitored at m/z 940.6/316.4. The accuracy, precision, linearity, range and lower limit of quantification (LLOQ) were determined. The accuracy was ≤9.93% and the precision was ≤10.6%. The range was established as 0.1 to 40 μg·mL-1. The LLOQ was 0.1 μg·mL-1 VAN requiring 2 μL of sample with an accuracy of -20.2% and precision of 8.39%. The method was applied successfully to determine the VAN concentrations in rabbit serum after the i.v. administration of VAN via implanted ear catheters. 展开更多
关键词 ultra-high performance liquid chromatography-Tandem Mass Spectrometry VANCOMYCIN RABBIT SERUM PHARMACOKINETICS
下载PDF
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
5
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 ultra-high performance liquid chromatography/Orbitrap High Resolution Mass Spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
6
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass SPECTROMETRY (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
Simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation by ultra-high performance liquid chromatography coupled with nano quantity analyte detector
7
作者 Honggen Zhang ZhenyuWang Oscar Liu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第1期11-17,共7页
A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical... A novel method for simultaneous determination of kolliphor HS15 and miglyol 812 in microemulsion formulation was developed using ultra-high performance liquid chromatography coupled with a nano quantitation analytical detector (UHPLC-NQAD). All components in kolliphor HS15 and miglyo1812 were well separated on an Acquity BEH C18 column. Mobile phase A was 0.1% trifluoroacetic acid (TFA) in water and mobile phase B was acetonitrile. A gradient elution sequence was programed initially with 60% organic solvent, slowly increased to 100% within 8 min. The flow rate was 0.7 mL/min. Good linearity (r 〉 0.95) was obtained in the range of 27.6-1381.1 μg/mL for polyoxyl 15 hydroxystearate in kolliphor HS15, 0.8-202.0 μg/mL for caprylic acid triglyceride and 2.7-221.9μg/mL for capric acid triglyceride in miglyol 812. The relative standard deviations (RSD) ranged from 0.6% to 1.7% for intra-day precision and from 0.4% to 2.7% for inter-day precision. The overall recoveries (accuracy) were 99.7%-101.4% for polyoxyl 15 hydroxystearate in kolliphor HS15, 96.7%-99.6% for caprylic acid triglyceride, and 94.1%- 103.3% for capric acid triglyceride in miglyol 812. Quantification limits (QL) were determined as 27.6 μg/ mL for polyoxy115 hydroxystearate in kolliphor HS15, 0.8 μg/mL for caprylic acid triglyceride, and 2.7 μg/ mL for capric acid triglyceride in miglyol 812. No interferences were observed in the retention time ranges of kolliphor HSI5 and miglyol 812. The method was validated in terms of specificity, linearity, precision, accuracy, QL, and robustness. The proposed method has been applied to microemulsion for- mulation analyses with good recoveries (82.2%-103.4%). 展开更多
关键词 Kolliphor HS15 Miglyol 812 ultra-high performance liquid chromato-graphy (UHPLC) Nano quantitation analytical detector(NQAD)
下载PDF
Development of a Rapid and Simultaneous Detection Method for Buprenorphine, Norbuprenorphine and Naloxone in Human Plasma Using Ultra-high Performance Liquid Chromatography- tandem Mass Spectrometer with Solid-phase Extraction 被引量:1
8
作者 Guo, Qiaozhen Du, Zhenxia 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2011年第9期1922-1926,共5页
A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone ... A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone (NLX) in human plasma. The method used buprenorphine-d4 (BP-D4), nor-buprenorphine-d3 (NBP-D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid-phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min^-1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1--25, 0.25--25 and 0.05--25 ng·mL^-1 for BP, NBP and NLX, respectively, with r≥0.9935. The method had high sensitivity (the lim- its of detection were 0.02, 0.1 and 0.01 ng.mL-1 for BP, NBP and NLX, respectively) and high recoveries (≥97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bio- analytical method: intra and inter assay precisions within the required limits of ≤25% RSD. The LOQs fulfilled the LOQ requirements: precision≤25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra-high performance liquid chromatography- tandem mass spectrometer (UPLC-MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometer BUPRENORPHINE naloxone norbuprenorphine human plasma
原文传递
Simultaneous Determination and Pharmacokinetics of Tetrandrine,Fangchinoline,and Cyclanoline in Rat Plasma by Ultra-High Performance Liquid Chromatography-Mass Spectrometry after Oral Administration of Stephaniae Tetrandrae Radix Extract 被引量:1
9
作者 Zhi-Bin Wang Yue Ma +3 位作者 Hua Liu Yu-Jin Bi Meng Wang Hai-Xue Kuang 《World Journal of Traditional Chinese Medicine》 2021年第1期130-137,共8页
Objective:The objective of the study was to develop a rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometric method for the determination of tetrandrine,fangchinoline,and cyclanoline in ... Objective:The objective of the study was to develop a rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometric method for the determination of tetrandrine,fangchinoline,and cyclanoline in rat plasma and to investigate their pharmacokinetics after oral administration of Stephaniae Tetrandrae Radix extracts.Methods:Sample pretreatment involved methanol pretreatment and liquid–liquid extraction of ethyl acetate from plasma with methanol.Tramadol was used as the internal standard.The analysis was performed using an high strength silica T3 column(100 mm×2.1 mm,1.8μm)and a gradient elution method consisting of mobile phase solution A(0.1%formic acid in water)and B(acetonitrile)at a flow rate of 0.4 mL/min.The detection was performed using a triple quadrupole tandem mass spectrometer in the multiple reaction monitoring mode and using an electrospray ionization source in the positive ionization mode.Results:High efficiency was achieved with an analysis time of 4 min/sample.The calibration curve linear in the concentration range of 1250 ng/ml(R^(2)≥0.9900)and the lower limit of quantification is 1 ng/ml.The intraday and interday precision(relative standard deviation)values were lower than 9.4.Accuracy(relative error)was within 10.3%at all three quality control levels.Conclusions:This method was successfully applied in pharmacokinetics of tetrandrine,fangchinoline,and cyclanoline in rats after oral administration of Stephaniae Tetrandrae Radix extracts.The maximum plasma concentration(C_(max))of tetrandrine,fangchinoline,and cyclanoline was 124.71±16.08,84.56±3.28,and 57.61±6.26 ng/mL,respectively.The time to reach C_(max)was 10.39±3.04 for tetrandrine,10.17±3.04 for fangchinoline,and 6.40±3.16 for cyclanoline.The pharmacokinetic results might help further guide the clinical application of Stephaniae Tetrandrae Radix. 展开更多
关键词 PHARMACOKINETICS rat plasma stephaniae tetrandrae radix ultra-high performance liquid chromatography-mass spectrometry
原文传递
A High-Performance Liquid Chromatography Method for the Simultaneous Determination of Five Index Components in Danhong Injection
10
作者 Yun An Tian Tian +2 位作者 Qinglin Wang Xingchu Gong Chenchen Zhang 《American Journal of Analytical Chemistry》 2023年第11期481-492,共12页
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a... The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R<sup>2</sup>> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. 展开更多
关键词 Danhong Injection High performance liquid chromatography Phenolic Acid FLAVONOIDS
下载PDF
Evaluation of Uncertainty in Determination of Ethyl Maltol in Vegetable Oil by Ultra-high Performance Liquid Chromatograph-Mass Spectrometer(UPLC-MS)
11
作者 Lei ZHANG 《Agricultural Biotechnology》 CAS 2023年第3期113-115,共3页
[Objectives]This study was conducted to establish an uncertainty evaluation method for the determination of ethyl maltol by ultra-high performance liquid chromatograph-mass spectrometer(UPLC-MS).[Methods]A mathematica... [Objectives]This study was conducted to establish an uncertainty evaluation method for the determination of ethyl maltol by ultra-high performance liquid chromatograph-mass spectrometer(UPLC-MS).[Methods]A mathematical model of uncertainty was established by analyzing the method for determining ethyl maltol using UPLC-MS.The sources of uncertainty were analyzed,and the components of uncertainty were calculated to evaluate the expanded uncertainty of the method.[Results]When the content of ethyl maltol in edible vegetable oil was 1657μg/kg,the expanded uncertainty was 22.4μg/kg(K=2,P=95%).[Conclusions]The uncertainty in this evaluation model mainly came from standard solution preparation,sample weighing,dilution of sample to constant volume,standard curve fitting,and repeated measurement. 展开更多
关键词 ultra-high performance liquid chromatograph-mass spectrometer DETERMINATION Ethyl maltol Uncertainty
下载PDF
Determination of Tetracyclines and Their Epimers in Agricultural Soil Fertilized with Swine Manure by Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry 被引量:9
12
作者 ZHENG Wen-li ZHANG Li-fang +2 位作者 ZHANG Ke-yu WANG Xiao-yang XUE Fei-qun 《Journal of Integrative Agriculture》 SCIE CSCD 2012年第7期1189-1198,共10页
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte... A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites. 展开更多
关键词 TETRACYCLINES EPIMERS ultra performance liquid chromatography SOIL solid phase extraction
下载PDF
Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography: I.Development and Assesment of Chromatographic Conditions 被引量:4
13
作者 SHENJIANBO ZHANGFUSUO 《Pedosphere》 SCIE CAS CSCD 1998年第2期97-104,共8页
Plantrootsexudeavarietyoforganiccompoundstotherhizosphere.Theamountofrootexudates,expresedasafractionoftheto... Plantrootsexudeavarietyoforganiccompoundstotherhizosphere.Theamountofrootexudates,expresedasafractionofthetotaldrymaterproduc... 展开更多
关键词 高效液相色谱法 有机酸 大豆 根围 根部分泌液 测定
下载PDF
Determination of Sodium Pentachlorophenoxide Residues in Animal-derived Foods by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS)
14
作者 Chengmei WANG Chunxia CHENG +2 位作者 Guixia YANG Susu ZHANG Xuan QIAN 《Agricultural Biotechnology》 CAS 2022年第2期99-101,105,共4页
[Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The ... [Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The samples were extracted with an acetonitrile water solution(8∶2),0.1 mol/L hydrochloric acid and a purification extraction bag with shaking.Centrifugation was performed to obtain supernatants,which were added to purification tubes containing PSA and C_(18) for purification,and then filtered with membranes for determination.Each test solution was separated by a ZORBAX Eclipse plus C_(18) column with acetonitrile and 5 mmol/L ammonium acetate as mobile phases,and determined with electrospray ionization and multiple reaction monitoring.[Results]The method had good linearity in the concentration range of 1.0-50 ng/ml,and the correlation coefficient was 0.9997.The limit of detection was 0.25μg/kg and the limit of quantification was 0.75μg/kg.The recovery was between 87.4%and 112.5%,and the RSD%was between 0.5%and 10.0%.[Conclusions]The method has simple operation and high sensitivity,and is suitable for trace detection of sodium pentachlorophenoxide in large quantities of animal-derived food. 展开更多
关键词 Sodium pentachlorophenoxide ultra-high performance liquid chromatography-tandem mass spectrometry Animal-derived food Trace analysis
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
15
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides High performance liquid chromatography Diode array detection Dispersive liquid-liquid microextraction Water samples
下载PDF
Determination of the Flavonoids from Ginkgo Biloba Extract by High Performance Liquid Chromatography 被引量:3
16
作者 Li ZHANG Zhi Min XIANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第10期968-970,共3页
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph... HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE. Experimental conditions: column: Hypersil BDS C18,5mm×4×250 mm; column temperature: 35C; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm. 展开更多
关键词 ginkgo biloba extract flavone glycoside high performance liquid chromatography
下载PDF
Fingerprint analysis of placenta polypeptide injection by high performance liquid chromatography 被引量:2
17
作者 Li Huanga, Xiao-Man Wub, Yu Jib, Yu Wanga,baChina Pharmaceutical University, Nanjing 210009, China bJiangsu Institute for Food and Drug Control, Nanjing 210008, China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第1期71-75,共5页
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm... Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection. 展开更多
关键词 Placenta polypeptide injection FINGERPRINT Similarity analysis High performance liquid chromatography
下载PDF
Determination of 17<i>α</i>-Methyltestosterone in Freshwater Samples of Tilapia Farming by High Performance Liquid Chromatography 被引量:3
18
作者 Isabel R. Barbosa Sara Lopes +3 位作者 Rhaul Oliveira Inês Domingues Amadeu M. V. M. Soares António J. A. Nogueira 《American Journal of Analytical Chemistry》 2013年第4期207-211,共5页
17α-methyltestosterone is used to induce the sex reversal of Tilapia sp. to obtain cultures mono-sex to an economically viable. This practice may lead to environmental contamination and problems in human health. Ther... 17α-methyltestosterone is used to induce the sex reversal of Tilapia sp. to obtain cultures mono-sex to an economically viable. This practice may lead to environmental contamination and problems in human health. Therefore methods need to be developed to detect residues of 17α-methyltestosterone in aqueous matrices. A simple high-performance liquid chromatographic method using ultraviolet detection (245 nm) and testosterone as internal standard has been developed for the monitoring 17α-methyltestosterone in freshwater samples of tilapia aquaculture. The method described involves limited sample preparation as it includes a filtration followed by a single solid-phase extraction step using C18 cartridge. Validation data indicated that the HPLC-UV method for 17α-methyltestosterone determination in the concentration range of 50 - 2000 μg/L provided good linearity, sensitivity, accuracy and precision. Method performance was efficiently applied to monitoring the freshwater samples of fish ponds and the surrounding aquatic channels. 展开更多
关键词 17α-Methyltestosterone High performance liquid chromatography Environment TILAPIA FARMING
下载PDF
Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods 被引量:1
19
作者 Cheng-Ping Li1,2,Mao Mao1,Lan-Jun Zheng1,Wei-Guang Shan11.College of Pharmaceutical Sciences,Zhejiang University of Technology,Hangzhou 310032 2.College of Biology and Environment Engineering,Zhejiang Shuren University,Hangzhou 310015,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期218-222,共5页
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co... Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine. 展开更多
关键词 GANCICLOVIR related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:1
20
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 High performance liquid chromatography Mass spectrometry RASAGILINE liquid-liquid extraction
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部