The ultrasonic attenuation coefficient is one of the most important acoustic parameters to character the performance of a thin layer media, but it can not be measured due to mutual superposition of multiple reflected ...The ultrasonic attenuation coefficient is one of the most important acoustic parameters to character the performance of a thin layer media, but it can not be measured due to mutual superposition of multiple reflected waves at the same interface in ultrasonic testing. Ultrasonic pulse echo and lamb wave to evaluate the thin layer media can not obtain attenuation coefficient at present. In this paper, analytical method was used to study the acoustics characteristic of thin layer media with the ultrasonic echo testing. Meanwhile, the process of ultrasonic attenuation measurement was presented. Simulation and experimental investigation is focused on a thin layer of rubber. Attenuation coefficient was introduced and evaluation mathematics model was established by the two echoes cross-correlation with and without the thin layer media based on the time delay spectrum. It involved the parameters related to the acoustic properties of the thin layer media. Through calculating the sound velocity and acoustic impedance with the evaluation model, it can deduce the relation between the attenuation coefficient and the frequency. Through analyzing the simulation results, it indicated that the attenuation coefficients were invariable with the varying of the frequency. However, the attenuation coefficients increased with the frequency increasing by ultrasonic testing the thin layer of rubber. The reason was that the attenuation factor was not taken into account during the simulation. This method overcomes shortcomings that the traditional ultrasonic testing can not evaluate the thin layer media whose thickness is less than motivation wavelength. It is a new solution to study the attenuation characteristic and on-line nondestructive evaluation in the thin layer media.展开更多
The quality factor(or Q value)is an important parameter for characterizing the inelastic properties of rock.Achieving a Q value estimation with high accuracy and stability is still challenging.In this study,a new meth...The quality factor(or Q value)is an important parameter for characterizing the inelastic properties of rock.Achieving a Q value estimation with high accuracy and stability is still challenging.In this study,a new method for estimating ultrasonic attenuation using a spectral ratio based on an S transform(SR-ST)is presented to improve the stability and accuracy of Q estimation.The variable window of ST is used to solve the time window problem.We add two window factors to the Gaussian window function in the ST.The window factors can adjust the scale of the Gaussian window function to the ultrasonic signal,which reduces the calculation error attributed to the conventional Gaussian window function.Meanwhile,the frequency bandwidth selection rules for the linear regression of the amplitude ratio are given to further improve stability and accuracy.First,the feasibility and influencing factors of the SR-ST method are studied through numerical testing and standard sample experiments.Second,artificial samples with different Q values are used to study the adaptability and stability of the SR-ST method.Finally,a further comparison between the new method and the conventional spectral ratio method(SR)is conducted using rock field samples,again addressing stability and accuracy.The experimental results show that this method will yield an error of approximately 36%using the conventional Gaussian window function.This problem can be solved by adding the time window factors to the Gaussian window function.The frequency bandwidth selection rules and mean slope value of the amplitude ratio used in the SR-ST method can ensure that the maximum error of different Q values estimation(Q>15)is less than 10%.展开更多
为研究高浓度纳米颗粒悬浮液的粒径分布表征,引入超声谱高浓度颗粒粒径测量理论(核壳模型),同时搭建了一套超声法高浓度悬浮液粒径测量实验装置,并进行理论模型的实验验证,测得体积浓度为10%至30%的纳米铟锡金属氧化物(Indium Tin Oxide...为研究高浓度纳米颗粒悬浮液的粒径分布表征,引入超声谱高浓度颗粒粒径测量理论(核壳模型),同时搭建了一套超声法高浓度悬浮液粒径测量实验装置,并进行理论模型的实验验证,测得体积浓度为10%至30%的纳米铟锡金属氧化物(Indium Tin Oxides,ITO)水性悬浮液的超声衰减,通过数据反演技术最终获取样品的颗粒粒径分布。结果表明:高浓度纳米颗粒悬浮液中声衰减系数随浓度增加但偏离线性递增趋势,与核壳模型数值模拟更接近。同时,粒径反演的结果与高速离心沉降法也较为吻合。展开更多
基金supported by National Natural Science Foundation of China (Grant No. 50802009)Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20070151024)
文摘The ultrasonic attenuation coefficient is one of the most important acoustic parameters to character the performance of a thin layer media, but it can not be measured due to mutual superposition of multiple reflected waves at the same interface in ultrasonic testing. Ultrasonic pulse echo and lamb wave to evaluate the thin layer media can not obtain attenuation coefficient at present. In this paper, analytical method was used to study the acoustics characteristic of thin layer media with the ultrasonic echo testing. Meanwhile, the process of ultrasonic attenuation measurement was presented. Simulation and experimental investigation is focused on a thin layer of rubber. Attenuation coefficient was introduced and evaluation mathematics model was established by the two echoes cross-correlation with and without the thin layer media based on the time delay spectrum. It involved the parameters related to the acoustic properties of the thin layer media. Through calculating the sound velocity and acoustic impedance with the evaluation model, it can deduce the relation between the attenuation coefficient and the frequency. Through analyzing the simulation results, it indicated that the attenuation coefficients were invariable with the varying of the frequency. However, the attenuation coefficients increased with the frequency increasing by ultrasonic testing the thin layer of rubber. The reason was that the attenuation factor was not taken into account during the simulation. This method overcomes shortcomings that the traditional ultrasonic testing can not evaluate the thin layer media whose thickness is less than motivation wavelength. It is a new solution to study the attenuation characteristic and on-line nondestructive evaluation in the thin layer media.
基金supported by the Special Fund of the Institute of Geophysics,China Earthquake Administration(Nos.DQJB19B02 and DQJB17T04)
文摘The quality factor(or Q value)is an important parameter for characterizing the inelastic properties of rock.Achieving a Q value estimation with high accuracy and stability is still challenging.In this study,a new method for estimating ultrasonic attenuation using a spectral ratio based on an S transform(SR-ST)is presented to improve the stability and accuracy of Q estimation.The variable window of ST is used to solve the time window problem.We add two window factors to the Gaussian window function in the ST.The window factors can adjust the scale of the Gaussian window function to the ultrasonic signal,which reduces the calculation error attributed to the conventional Gaussian window function.Meanwhile,the frequency bandwidth selection rules for the linear regression of the amplitude ratio are given to further improve stability and accuracy.First,the feasibility and influencing factors of the SR-ST method are studied through numerical testing and standard sample experiments.Second,artificial samples with different Q values are used to study the adaptability and stability of the SR-ST method.Finally,a further comparison between the new method and the conventional spectral ratio method(SR)is conducted using rock field samples,again addressing stability and accuracy.The experimental results show that this method will yield an error of approximately 36%using the conventional Gaussian window function.This problem can be solved by adding the time window factors to the Gaussian window function.The frequency bandwidth selection rules and mean slope value of the amplitude ratio used in the SR-ST method can ensure that the maximum error of different Q values estimation(Q>15)is less than 10%.
文摘为研究高浓度纳米颗粒悬浮液的粒径分布表征,引入超声谱高浓度颗粒粒径测量理论(核壳模型),同时搭建了一套超声法高浓度悬浮液粒径测量实验装置,并进行理论模型的实验验证,测得体积浓度为10%至30%的纳米铟锡金属氧化物(Indium Tin Oxides,ITO)水性悬浮液的超声衰减,通过数据反演技术最终获取样品的颗粒粒径分布。结果表明:高浓度纳米颗粒悬浮液中声衰减系数随浓度增加但偏离线性递增趋势,与核壳模型数值模拟更接近。同时,粒径反演的结果与高速离心沉降法也较为吻合。