期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
Research and Application of Log Defect Detection and Visualization System Based on Dry Coupling Ultrasonic Method
1
作者 Yongning Yuan Dong Zhang +4 位作者 Usama Sayed Hao Zhu Jun Wang Xiaojun Yang Zheng Wang 《Journal of Renewable Materials》 EI 2023年第11期3917-3932,共16页
In order to optimize the wood internal quality detection and evaluation system and improve the comprehensive utilization rate of wood,this paper invented a set of log internal defect detection and visualization system... In order to optimize the wood internal quality detection and evaluation system and improve the comprehensive utilization rate of wood,this paper invented a set of log internal defect detection and visualization system by using the ultrasonic dry coupling agent method.The detection and visualization analysis of internal log defects were realized through log specimen test.The main conclusions show that the accuracy,reliability and practicability of the system for detecting the internal defects of log specimens have been effectively verified.The system can make the edge of the detected image smooth by interpolation algorithm,and the edge detection algorithm can be used to detect and reflect the location of internal defects of logs accurately.The content mentioned above has good application value for meeting the requirement of increasing demand for wood resources and improving the automation level of wood nondestructive testing instruments. 展开更多
关键词 ultrasonic method log defect detection visualization system dry coupling B-scan pulse transmission method bilinear image interpolation algorithm edge detection algorithm
下载PDF
TECHNOLOGY OF QUANTITATIVE ANALYSIS ON VIBRATORY STRESS RELIEF BASED ON ULTRASONIC TIME-OF-ARRIVAL METHOD 被引量:4
2
作者 He Wen Ma Zhenyu Wang Xingli 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第3期461-463,共3页
The effect of vibratory stress relief (VSR) is usually evaluated with the indirect method of observing the change of amplitude frequency response characteristics of structures. A new kind of evaluating method of VSR... The effect of vibratory stress relief (VSR) is usually evaluated with the indirect method of observing the change of amplitude frequency response characteristics of structures. A new kind of evaluating method of VSR based on the ultrasonic time-of-arrival method (UTM), which can obtain the residual stress directly through measuring the propagation time of ultrasonic wave in the material, is presented. At first, the principle of the measuring method of residual stress based on UTM is analyzed. Then the measuring system of the method is described, which is in virtue of ultrasonic flaw detector and high-sampling-rate digital oscillograph. And a set of calibration system that contains a piece of standard specimen is also introduced. Experimental results prove the relation between the residual stress and the propagation time of ultrasonic in workpieces. Finally, the measuring and calibration systems are applied in evaluating the effect of VSR. The final test results show that the method is effective. 展开更多
关键词 ultrasonic time-of-arrival method Residual stress Measure Vibratory stress relief
下载PDF
An efficient nano-adsorbent via surfactants/dual surfactants assisted ultrasonic co-precipitation method for sono-removal of monoazo and diazo anionic dyes
3
作者 Marwa M.Ibrahim 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期225-236,共12页
To preserve the environment for civilization,we should remove the pollutants like toxic dyes by friendly and cost efficacious method.In this study,the effect of surfactants or mixed surfactants on physicochemical,opti... To preserve the environment for civilization,we should remove the pollutants like toxic dyes by friendly and cost efficacious method.In this study,the effect of surfactants or mixed surfactants on physicochemical,optical and adsorption properties of ternary mixed oxide CeO_(2)-ZrO_(2)-Al_(2) O_3(CZA) are investigated.The ternary mixed oxide CZA was prepared by surfactants or mixed surfactants assisted ultrasonic coprecipitation method.The physicochemical and optical properties are estimated by different techniques like XRD,TEM,EDX,FTIR,S_(BET) and UV-Vis/DR.The CZA_T and CZA_C have hybrid shapes and high surface area.The adsorption properties of ternary mixed oxides adsorbents were characterized by sono-removing anionic dyes such as Congo red(CR) and Remazol red RB-133(RR).The different factors like contact time,different dye concentrations and temperatures also studied.The kinetics and isotherms applications showed that,the adsorption process was followed pseudo second order kinetics and the Freundlich isotherm model.Also,the adsorption is spontaneous and endothermic process through the thermodynamic study.Finally,the results showed that the ternary mixed oxide nano-adsorbent(CeO_(2)-ZrO_(2)-Al_(2) O_3) is promising and functional materials for anionic dye sweep from wastewater. 展开更多
关键词 CeO_(2)-ZrO_(2)-Al_(2)O_3 SURFACTANTS ultrasonic co-precipitation method Optical properties Wastewater Adsorption
下载PDF
Numerical simulation of flow in Hartmann resonance tube and flow in ultrasonic gas atomizer 被引量:1
4
作者 李博 胡国辉 周哲玮 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2007年第11期1415-1426,共12页
The gas flow in the Hartmann resonance tube is numerically investigated by the finite volume method based on the Roe solver. The oscillation of the flow is studied with the presence of a needle actuator set along the ... The gas flow in the Hartmann resonance tube is numerically investigated by the finite volume method based on the Roe solver. The oscillation of the flow is studied with the presence of a needle actuator set along the nozzle axis. Numerical results agree well with the theoretical and experimental results available. Numerical results indicate that the resonance mode of the resonance tube will switch by means of removing or adding the actuator. The gas flow in the ultrasonic gas atomization (USGA) nozzle is also studied by the same numerical methods. Oscillation caused by the Hartmann resonance tube structure, coupled with a secondary resonator, in the USGA nozzle is investigated. Effects of the variation of parameters on the oscillation are studied. The mechanism of the transition of subsonic flow to supersonic flow in the USGA nozzle is also discussed based on numerical results. 展开更多
关键词 Hartmann resonance tube spray atomization ultrasonic gas atomization finite volume method roe solver
下载PDF
Laminar Mesoporous Structure of Modified Montmorillonite Clays and Its Formation Mechanism 被引量:1
5
作者 张颖 陈爱平 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第2期321-327,共7页
Zr-pillared clays were prepared by heating and ultrasonic methods in intercalation process. The resultants were characterized by XRD, N2 adsorption-desorption, SEM, and TG/DTA analysis. Ultrasonic technology accelerat... Zr-pillared clays were prepared by heating and ultrasonic methods in intercalation process. The resultants were characterized by XRD, N2 adsorption-desorption, SEM, and TG/DTA analysis. Ultrasonic technology accelerated the pillaring process effectively and obtained better ordered structure than by heating method. The specific surface area and pore volume of the Zr-pillared clays increased by about 13 and 3 times respectively. Rare earth metal (Ce) was introduced into Zr-pillared clays by co-intercalation and dipping method. The specific surface area was increased by co-intercalation approach, but it was decreased dramatically by dipping method. Thermal stability of Ce modified samples prepared by co-intercalation method was enhanced in comparison with Zr-pillared clays. Modification mechanism and "corrugation-like" structural mode of intercalation process was proposed basing on the double XRD peaks in small-angle range of pillared clays, which was related to the deformation of silicate layer. 展开更多
关键词 Zr-pillared clay ultrasonic method CE "corrugationlike" structural model
下载PDF
Synthesis,Structural Characterization and Hydrogen Storage of Nickel-containing Mesoporous MCM-48 by Electroless Plating 被引量:1
6
作者 张光旭 REN Xiaocong +1 位作者 FANG Yuan CHEN Jian 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第1期64-67,共4页
Hydrogen is a promising fuel for it is clean,highly abundant and non-toxic,but on-board storage of hydrogen is still a challenge.So it is imperative to have an efficient method of hydrogen storage.The mesoporous MCM-4... Hydrogen is a promising fuel for it is clean,highly abundant and non-toxic,but on-board storage of hydrogen is still a challenge.So it is imperative to have an efficient method of hydrogen storage.The mesoporous MCM-48 especially the nickel-containing MCM-48 has great potential in hydrogen storage.MCM-48 was prepared by hydrothermal synthesis.Then electroless plating technology was used to deposit Ni on the surface of MCM-48 under ultrasonic environment.Powder X-ray diffraction(XRD),transmission electron microscopy(TEM),and N2 adsorption-desorption were employed to investigate the pore structure properties.The results showed that all the samples had Ia3 d cubic structure and pore channels were highly ordered.Hydrogen adsorption studies showed that the MCM-48 after nickel plating adsorbed nearly twice the amount of hydrogen than pure MCM-48 at 2.0 MPa,263 K.So we believe that a small amount of Ni can improve the capacity of hydrogen adsorption of MCM-48 efficiently. 展开更多
关键词 MCM-48 electroless Ni-plating ultrasonic method metallic composites hydrogen storage
下载PDF
The spectrum entropy estimation method for ultrasonic backscattering signal in cancellous bones 被引量:2
7
作者 XU Feng XU Yiwen +2 位作者 LIU Chengcheng TA De'an GUO Jianzhong 《Chinese Journal of Acoustics》 CSCD 2017年第3期337-346,共10页
In the application of cancellous bone ultrasound diagnosis based on backscattering method, it is of great importance to estimate fast and accurately whether the valid backscattering signal exists in the received signa... In the application of cancellous bone ultrasound diagnosis based on backscattering method, it is of great importance to estimate fast and accurately whether the valid backscattering signal exists in the received signal. We propose a fast estimation method based on spectrum entropy method. With 984 records of adult calcaneus clinical data, we estimate the validity of the backscatter signal using this method. The results of the proposed method and the results of experience-base judgement were compared and analyzed. And two key parameters, the signal range length and the segment number of the spectrum entropy, were analyzed. The results show when the signal range length is 13 I^s and the segment number is 15 20, this method can get the best result (accuracy〉95%, sensitivity〉99%, specificity〉87%), while taking little calculation time (1.5 ms). Therefore, this spectrum entropy method can satisfy the accuracy and real-time requirements in the ultrasonic estimation for cancellous bone. 展开更多
关键词 BONE The spectrum entropy estimation method for ultrasonic backscattering signal in cancellous bones
原文传递
Bulk heterojunction thin film formation by single and dual feed ultrasonic spray method for application in organic solar cells 被引量:1
8
作者 D.M.Marathe H.S.Tarkas +3 位作者 M.S.Mahajan G.S.Lonkar S.R.Tak J.V.Sali 《Journal of Semiconductors》 EI CAS CSCD 2016年第9期47-50,共4页
We here present a way of preparing the polymer: fullerene BHJ using dual feed method which can lead to formation of pure phases. In this report, we present results of our initial experiments in this direction.The eff... We here present a way of preparing the polymer: fullerene BHJ using dual feed method which can lead to formation of pure phases. In this report, we present results of our initial experiments in this direction.The effect of process parameters on the thickness and surface roughness of the active layer has been discussed.The structural and optical properties have been studied using the optical microscope, UV–visible spectroscopy and photoluminescence spectroscopy. Significant PL quenching indicates efficient charge separation in the BHJ formed using this technique. We have also compared the BHJ thin films prepared with this dual feed ultrasonic technique with the single feed spray method. The BHJ formed using this technique has been used as an active layer in OSC. 展开更多
关键词 P3HT PCBM dual feed ultrasonic spray method organic solar cell
原文传递
Low frequency ultrasonic multi-mode Lamb wave method for characterizing the ultra-thin transversely isotropic laminate composite: Theory and experiment 被引量:1
9
作者 ZHANG Rui, WAN Mingxi, CHEN Xiao, (Department of Biomedical Engineering Xi’an Jiaotong University Xi’an 710049) CAO Wenwu is with the Intercollege Materials Research Laboratory The Pennsylvania State University University Park, PA, 16802, USA 《Chinese Journal of Acoustics》 2001年第4期355-364,共10页
A low-frequency multi-mode ultrasonic Lamb wave method suitable for character- izing the thickness, the density and the elastic constants of the ultra-thin transversely isotropic laminate composite is presented. The &... A low-frequency multi-mode ultrasonic Lamb wave method suitable for character- izing the thickness, the density and the elastic constants of the ultra-thin transversely isotropic laminate composite is presented. The 'ultra-thin' here means that the thickness of the plate is much less than the wavelength of the ultrasonic wave so that the echoes from the front and back faces of the plate can't be separated in the time domain. The dispersion equations for the low frequency ultrasonic Lamb waves with the propagation directions parallel and vertical to the fiber direction are derived. In conjunction with the least square algorithm method, the secant algorithm is used to estimate the parameters of the ultra-thin fiber-reinforced composite layer. The evaluation errors and the sensitivity of the method to different paramters of the thin composite are analyzed. The technique has been used to characterize the ultra-thin grass fiber reinforced PES composite with thickness down to ten percents of the ultrasonic wavelength. It is observed that the agreement between the nominal and the estimation values is reasonably good. 展开更多
关键词 wave mode Theory and experiment Low frequency ultrasonic multi-mode Lamb wave method for characterizing the ultra-thin transversely isotropic laminate composite
原文传递
Effect of diffraction on the ultrasonic velocity measuredby the pulse interference method in VHF range 被引量:1
10
作者 WEI Tingcun(Department of Electrical Engineering, Tohoku University Japan) 《Chinese Journal of Acoustics》 2002年第1期30-35,共6页
The effect of diffraction on the ultrasonic velocity measured by the pulse interference method has been investigated in VHF range theoretically and experimentally. Two silicate glasses are taken as the specimens, thei... The effect of diffraction on the ultrasonic velocity measured by the pulse interference method has been investigated in VHF range theoretically and experimentally. Two silicate glasses are taken as the specimens, their frequency dependences of longitudinal velocities are measured in the frequency range of 50-350 MHz, and the phase advances of ultrasonic signals caused by diffraction effect are calculated using A. O. Williams' theoretical expression. For the velocity error due to diffraction effect, the experimental results are in good agreement with the theoretical prediction. It has been shown that the velocity error due to diffraction effect is directly proportional to dθ21 (f)/df, whereθ21 (f) is the phase advances difference between the two partial reflection signals used in velocity measurement and f is the ultrasonic frequency. 展开更多
关键词 Effect of diffraction on the ultrasonic velocity measuredby the pulse interference method in VHF range VHF
原文传递
An assessment on the wideband and narrowband methods for ultrasonic blood flow measurements
11
作者 QI Jinyi GAO Shangkai and YANG Fusheng(Dept. of electrical engineering, Tsinghua university Beijing 100084) 《Chinese Journal of Acoustics》 1997年第1期59-70,共12页
A comparison study on the ultrasonic blood flow estimation methods is carried out in this paper. The methods are divided into two classes-narrowband and wideband techniques.The pulsed Doppler systems and the autocorre... A comparison study on the ultrasonic blood flow estimation methods is carried out in this paper. The methods are divided into two classes-narrowband and wideband techniques.The pulsed Doppler systems and the autocorrelation methods are essentially the narrowband estAnators. They give the results with low velocity resolution and probably the aliased spectrum.The wider the frequency band of the signals, the worse the results. Time domain crosscorrelation technique, wideband makimum likelihood estimation and 2D Fourier transform method are three wideband techniques. The high velocity resolution and the ability of anti-aliasing are shown by these wideband estimation strategies. 展开更多
关键词 flow An assessment on the wideband and narrowband methods for ultrasonic blood flow measurements IEEE
原文传递
Extraction of Submerged Topographic Line in B-Scan Ultrasonic Image
12
作者 SONG Huan ZOU Xianjian YANG Weili 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2015年第4期350-354,共5页
The analysis of underwater topography ultrasonic image, which can be obtained by using B-scan ultrasound imaging technique, is the basis and important work in topography study. In this paper, we present a novel self-a... The analysis of underwater topography ultrasonic image, which can be obtained by using B-scan ultrasound imaging technique, is the basis and important work in topography study. In this paper, we present a novel self-adapted method for the extraction of submerged topographic line. Since the distribution of gray values in the image has a mutation process, this feature is used to appropriately track the topographic line of imaging band, and wavelet denoising method is applied to denoise the obtained lines. The described method also takes the continuity of topography into consideration during tracking procedure. The results show that the extraction error is within 2-pixel width(approximate 1 mm). This method is suitable for the extraction of current model topographic lines with the advantages of good self-adaption, high speed and high resolution. 展开更多
关键词 ultrasonic image submerged topography wavelet denoising method self-adapted tracking
原文传递
Multicolor biomass based carbon nanodots for bacterial imaging
13
作者 Wenbo Zhao Yong Wang +2 位作者 Kaikai Liu Rui Zhou Chongxin Shan 《Chinese Chemical Letters》 SCIE CAS CSCD 2022年第2期798-802,共5页
Biomass-based carbon nanodots(CNDs) are becoming promising fluorescent materials due to their superior optical properties and excellent biocompatibility. However, most fluorescent CNDs are prepared under high temperat... Biomass-based carbon nanodots(CNDs) are becoming promising fluorescent materials due to their superior optical properties and excellent biocompatibility. However, most fluorescent CNDs are prepared under high temperatures with artificial chemicals as precursors. In this work, multicolor biomass-based CNDs have been prepared by employing natural biomass as precursors through an ultrasonic-assisted method at room temperature. The multicolor biomass-based CNDs can be prepared within 10 min, and cavitation produced by ultrasound in solution contributes to the polymerization of biomolecules into nanodots. The emission of the CNDs covers from blue to red region, with emission peaks centered at 410 nm, 520 nm and 670 nm, and the corresponding photoluminescence quantum yields of the CNDs are 11%, 12% and28%, respectively. Furthermore, bacterial imaging by using the biomass-based CNDs as fluorescent imaging agent has been demonstrated. This work provides a convenient ultrasonic-assisted way for fabrication multicolor and eco-friendly biomass CNDs, demonstrating their application in bacterial imaging. 展开更多
关键词 Carbon nanodots BIOMASS Fluorescence ultrasonic methods Bacterial imaging
原文传递
Ultrasound Assisted Synthesis of Nanoscale NH2-MIL-53(Fe) for the Adsorption of Dye
14
作者 巫学敏 刘龙雪 +3 位作者 刘玲 尤梓涵 郭鸿旭 陈彰旭 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2021年第1期42-46,2,共6页
Nanometer blocks of amide-functionalized Fe(Ⅲ)-based metal-organic frameworks,NH2-MIL-53(Fe),were prepared via ultrasonic method without any surfactants at room temperature and atmospheric pressure.The characterizati... Nanometer blocks of amide-functionalized Fe(Ⅲ)-based metal-organic frameworks,NH2-MIL-53(Fe),were prepared via ultrasonic method without any surfactants at room temperature and atmospheric pressure.The characterization for the as-prepared nano-structured MOFs was established by XRD,SEM,TEM,XPS and N2 adsorption-desorption.The as-prepared sample with high specific surface area(179.9 m^(2)·g^(-1))showed excellent adsorption for methylene blue in the liquid phase.The as-prepared NH_(2)-MIL-53(Fe)adsorbent seems to be a promising material in practice for organic dye removal from aqueous solution. 展开更多
关键词 NH2-MIL-53(Fe) ultrasonic method REMOVAL methylene blue
原文传递
Laser-induced topology optimized amorphous nanostructure and corrosion electrochemistry of supersonically deposited Ni_(30)Cr_(25)Al_(15)Co_(15)Mo_(5)Ti_(5)Y_(5) HEA coating based on AIMD
15
作者 Xue Yan Cheng Zhang +3 位作者 Yangshuai Li Youjian Yi Ziruo Cui Bingyuan Han 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2022年第11期257-269,共13页
A novel Ni_(30)Cr_(25)Al_(15)Co_(15)Mo_(5)Ti_(5)Y_(5) high-entropy alloy(HEA)coating was irradiated to optimize its internal structure via laser after supersonic particle deposition(SPD).Owing to the high energy densi... A novel Ni_(30)Cr_(25)Al_(15)Co_(15)Mo_(5)Ti_(5)Y_(5) high-entropy alloy(HEA)coating was irradiated to optimize its internal structure via laser after supersonic particle deposition(SPD).Owing to the high energy density of the laser and large temperature gradient,the crystallization process of the molecules and atoms in the coating was restrained and supercooling occurred.Experimental results showed that a considerable number of nano-crystal grains precipitated and amorphous structures were formed because of the random orientation of the crystals.The baseline of differential scanning calorimetry scans obtained for the coating started to shift at the Tg of 939.37℃ and a step was observed.Multiple dispersion peaks and lattice fringes indicated that the nucleation of the irradiated laser-induced topology optimized(LTO)coating was incomplete.The laser-induced topology optimizing treatment led to quasi-isotropy in the SPD coating.Furthermore,the LTO coating exhibited a residual stress of 18.4 MPa,stress-strain response,and fatigue limit of 265 MPa.Hence,the LTO coating exhibited higher performance than the unirradiated SPD coating.The Nyquist and Bode electrochemical impedance spectra of the LTO coating,including two relaxation processes,indicated that the corrosion process steadily recovered to the equilibrium state.This implies that the uniform oxidation passivation layer on the surface of the LTO coating insulated the material from the corrosive medium,protecting the substrate from further corrosion,thus enhancing the structural security of the material for use in super-intense laser facility applications. 展开更多
关键词 ultrasonic atomization spin method(UASM) Laser-induced topology optimized(LTO) Amorphous nanostructure High-entropy alloy(HEA) Ab-initio molecular dynamics(AIMD)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部