期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
FEATURE EXTRACTION OF BONES AND SKIN BASED ON ULTRASONIC SCANNING 被引量:3
1
作者 Zheng Shuxian Zhao Wanhua +1 位作者 Lu Bingheng Zhao Zhao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第4期510-514,共5页
In the prosthetic socket design, aimed at the high cost and radiation deficiency caused by CT scanning which is a routine technique to obtain the cross-sectional image of the residual limb, a new ultrasonic scanning m... In the prosthetic socket design, aimed at the high cost and radiation deficiency caused by CT scanning which is a routine technique to obtain the cross-sectional image of the residual limb, a new ultrasonic scanning method is developed to acquire the bones and skin contours of the residual limb. Using a pig fore-leg as the scanning object, an overlapping algorithm is designed to reconstruct the 2D cross-sectional image, the contours of the bone and skin are extracted using edge detection algorithm and the 3D model of the pig fore-leg is reconstructed by using reverse engineering technology. The results of checking the accuracy of the image by scanning a cylinder work pieces show that the extracted contours of the cylinder are quite close to the standard circumference. So it is feasible to get the contours of bones and skin by ultrasonic scanning. The ultrasonic scanning system featuring no radiation and low cost is a kind of new means of cross section scanning for medical images. 展开更多
关键词 ultrasonic scanning image reconstruction Feature extraction Bones and skin Image accuracy
下载PDF
Ultrasonic focusing and scanning with multiple waves 被引量:2
2
作者 张碧星 刘冬冬 +1 位作者 师芳芳 Hefeng Dong 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期312-317,共6页
This paper presents a new focusing and scanning method which focuses multiple waves on a target. The key of the method is to control excitation pulses for each element of the transducer array. The excitation pulse on ... This paper presents a new focusing and scanning method which focuses multiple waves on a target. The key of the method is to control excitation pulses for each element of the transducer array. The excitation pulse on each array element is obtained by time reversing the signal received by the same element, which is generated by an imaginary source at the target. The excitation pulses from all array elements are transmitted and arrive at the target simultaneously, and focusing is achieved. The performance of the two methods is compared in numerical examples, and it is demonstrated that the proposed method achieves a satisfactory focusing and a good signal-to-noise ratio no matter where the target location is. 展开更多
关键词 ultrasonic focusing and scanning multiple waves transducer array
下载PDF
Nanofillers modification of Epocast 50-A1/946 epoxy for bonded joints 被引量:3
3
作者 U.A.Khashaba A.A.Aljinaidi M.A.Hamed 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2014年第5期1288-1300,共13页
Epocast 50-A1/946 epoxy was primarily developed for joining and repairing of composite aircraft structural components. The objective of the present work is to modify the Epocast epoxy resin by different nanofillers in... Epocast 50-A1/946 epoxy was primarily developed for joining and repairing of composite aircraft structural components. The objective of the present work is to modify the Epocast epoxy resin by different nanofillers infusion. The used nanofillers include multi-walled carbon nanotubes(MWCNTs), SiC and Al2O3 nanoparticles. The nanofillers with different weight percentages are ultrasonically dispersed in the epoxy resin. The sonication time and amplitude for MWCNTs are reduced compared to Al2O3 and SiC nanoparticles to avoid the damage of MWCNTs during sonication processes. The fabricated neat epoxy and twelve nanocomposite panels were characterized via standard tension and in-plane shear tests. The experimental results show that the nanocomposites materials with 0.5wt% MWCNTs, 1.5wt% SiC and 1.5wt% Al2O3 nanoparticles have the highest improvement in the tensile properties compared to the other nanofiller loading percentages.The improvements in the shear properties of these nanocomposite materials were respectively equal to 5.5%, 4.9%, and 6.3% for shear strengths, and 10.3%, 16.0%, and 8.1% for shear moduli. The optimum nanofiller loading percentages will be used in the following papers concerning their effect on the bonded joints/repairs of carbon fiber reinforced composites. 展开更多
关键词 Iosipescu shear tests Nanocomposites Optimum nanofiller weight percentage scanning electron microscopic Tension tests ultrasonic
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部