The water-lubricated thrust bearings of the marine rim-driven thruster(RDT)are usually composed of polymer composites,which are prone to serious wear under harsh working conditions.Ultrasonic is an excellent non-destr...The water-lubricated thrust bearings of the marine rim-driven thruster(RDT)are usually composed of polymer composites,which are prone to serious wear under harsh working conditions.Ultrasonic is an excellent non-destructive monitoring technology,but polymer materials are characterized by viscoelasticity,heterogeneity,and large acoustic attenuation,making it challenging to extract ultrasonic echo signals.Therefore,this paper proposes a wear monitoring method based on the amplitude spectrum of the ultrasonic reflection coefficient.The effects of bearing parameters,objective function,and algorithm parameters on the identification results are simulated and analyzed.Taking the correlation coefficient and root mean square error as the matching parameters,the thickness,sound velocity,density,and attenuation factor of the bearing are inversed simultaneously by utilizing the differential evolution algorithm(DEA),and the wear measurement system is constructed.In order to verify the identification accuracy of this method,an accelerated wear test under heavy load was executed on a multi-functional vertical water lubrication test rig with poly-ether-etherketone(PEEK)fixed pad and stainless-steel thrust collar as the object.The thickness of pad was measured using the high-precision spiral micrometer and ultrasonic testing system,respectively.Ultimately,the results demonstrate that the thickness identification error of this method is approximately 1%,and in-situ monitoring ability will be realized in the future,which is of great significance to the life prediction of bearings.展开更多
In the application of cancellous bone ultrasound diagnosis based on backscattering method, it is of great importance to estimate fast and accurately whether the valid backscattering signal exists in the received signa...In the application of cancellous bone ultrasound diagnosis based on backscattering method, it is of great importance to estimate fast and accurately whether the valid backscattering signal exists in the received signal. We propose a fast estimation method based on spectrum entropy method. With 984 records of adult calcaneus clinical data, we estimate the validity of the backscatter signal using this method. The results of the proposed method and the results of experience-base judgement were compared and analyzed. And two key parameters, the signal range length and the segment number of the spectrum entropy, were analyzed. The results show when the signal range length is 13 I^s and the segment number is 15 20, this method can get the best result (accuracy〉95%, sensitivity〉99%, specificity〉87%), while taking little calculation time (1.5 ms). Therefore, this spectrum entropy method can satisfy the accuracy and real-time requirements in the ultrasonic estimation for cancellous bone.展开更多
This paper contributes to extracting information from signals of broadband ultrasonic attenuation spectrum for effective utilization in particle size characterization. The single particle scattering model and the coup...This paper contributes to extracting information from signals of broadband ultrasonic attenuation spectrum for effective utilization in particle size characterization. The single particle scattering model and the coupled-phase model are formulated simultaneously, the relationship between particle size distribution and ultrasonic spectrum is established, and a convergence criterion for calculation is quantified. Demonstration inversion by the optimum regularization factor method is carried out to yield typical numerical results for discussion. With the experimental set-up developed by the Institute of Particle and Two-Phase Flow Measurement (IPTFM) at the University of Shanghai for Science and Technology, sand sediment particle size is measured by attenuation spectrum and analyzed using the above inversion algorithm and theoretical models. To validate the proposed ultrasonic spectrum particle sizing method, results are compared with those obtained by microscopy.展开更多
基金supported by the National Key R&D Program of China(No.2018YFE0197600)European Union’s Horizon 2020 Research and Innovation Programme RISE under Grant Agreement No.823759(REMESH)the National Natural Science Foundation of China(No.52071244).
文摘The water-lubricated thrust bearings of the marine rim-driven thruster(RDT)are usually composed of polymer composites,which are prone to serious wear under harsh working conditions.Ultrasonic is an excellent non-destructive monitoring technology,but polymer materials are characterized by viscoelasticity,heterogeneity,and large acoustic attenuation,making it challenging to extract ultrasonic echo signals.Therefore,this paper proposes a wear monitoring method based on the amplitude spectrum of the ultrasonic reflection coefficient.The effects of bearing parameters,objective function,and algorithm parameters on the identification results are simulated and analyzed.Taking the correlation coefficient and root mean square error as the matching parameters,the thickness,sound velocity,density,and attenuation factor of the bearing are inversed simultaneously by utilizing the differential evolution algorithm(DEA),and the wear measurement system is constructed.In order to verify the identification accuracy of this method,an accelerated wear test under heavy load was executed on a multi-functional vertical water lubrication test rig with poly-ether-etherketone(PEEK)fixed pad and stainless-steel thrust collar as the object.The thickness of pad was measured using the high-precision spiral micrometer and ultrasonic testing system,respectively.Ultimately,the results demonstrate that the thickness identification error of this method is approximately 1%,and in-situ monitoring ability will be realized in the future,which is of great significance to the life prediction of bearings.
基金supported by the National Natural Science Foundation of China(11327405,11525416,11604054,11504057)
文摘In the application of cancellous bone ultrasound diagnosis based on backscattering method, it is of great importance to estimate fast and accurately whether the valid backscattering signal exists in the received signal. We propose a fast estimation method based on spectrum entropy method. With 984 records of adult calcaneus clinical data, we estimate the validity of the backscatter signal using this method. The results of the proposed method and the results of experience-base judgement were compared and analyzed. And two key parameters, the signal range length and the segment number of the spectrum entropy, were analyzed. The results show when the signal range length is 13 I^s and the segment number is 15 20, this method can get the best result (accuracy〉95%, sensitivity〉99%, specificity〉87%), while taking little calculation time (1.5 ms). Therefore, this spectrum entropy method can satisfy the accuracy and real-time requirements in the ultrasonic estimation for cancellous bone.
基金National High Technology Development 863 Program(2006AA03Z349)National Science Foundation of China (50706029)Shang-hai Education Committee Foundation (07ZZ88)
文摘This paper contributes to extracting information from signals of broadband ultrasonic attenuation spectrum for effective utilization in particle size characterization. The single particle scattering model and the coupled-phase model are formulated simultaneously, the relationship between particle size distribution and ultrasonic spectrum is established, and a convergence criterion for calculation is quantified. Demonstration inversion by the optimum regularization factor method is carried out to yield typical numerical results for discussion. With the experimental set-up developed by the Institute of Particle and Two-Phase Flow Measurement (IPTFM) at the University of Shanghai for Science and Technology, sand sediment particle size is measured by attenuation spectrum and analyzed using the above inversion algorithm and theoretical models. To validate the proposed ultrasonic spectrum particle sizing method, results are compared with those obtained by microscopy.