期刊文献+
共找到31,563篇文章
< 1 2 250 >
每页显示 20 50 100
Different hemodynamic responses by color Doppler ultrasonography studies between sildenafil non-responders and responders 被引量:3
1
作者 Shih-Tsung Huang Ming-Li Hsieh 《Asian Journal of Andrology》 SCIE CAS CSCD 2007年第1期129-133,共5页
Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patien... Aim: To determine if there are different penile hemodynamic patterns between sildenafil non-responders and responders by using color Doppler ultrasonography. Methods: A total of 69 erectile dysfunction (ED) patients aged 22-79 years were enrolled into the present study. Thirty-eight (55.1%) men with ED who did not respond to four attempts of treatment with 100 mg sildenafil after re-education were classified as sildenafil non-responders. A com- bination of three vasodilator drugs, 1.25 mg papaverine, 0.4 mg phentolamine and 5 ug prostaglandin E1, was given by intracavernous injection before penile Doppler ultrasonography was carried out. The erectile response to intracavernous injection and vascular parameters including peak systolic velocity (PSV), resistance index (RI), end diastolic velocity (EDV) and cavernosa artery diameter (CD) were measured and the results between sildenafil nonresponders and responders were compared. Results: No statistical difference in vascular parameters measured by Doppler ultrasonography studies between non-responders and responders was noted. Sildenafil non-responders had a poorer penile rigidity response to intracavernous injection than responders (P 〈 0.05). Among patients with adequate PSV (〉 30 cm/s) and abnormal EDV (〉 5 cm/s), individuals in the non-responder group had fewer positive responses to intracavernous vasodilator injection than in the responder group (35.3% vs. 72.2%, P 〈 0.05). Advanced age and comorbidity with diabetes mellitus were significantly associated with sildenafil non-response (P 〈 0.05). Conclusion: Sildenafil non-responders were characterized by a poorer penile rigidity response to intracavernous injection and had an associated impaired veno-occlusive mechanism. Advanced age and comorbidity with diabetes mellitus were two common factors associated with non-response. 展开更多
关键词 color doppler ultrasonography erectile dysfunction IMPOTENCE sildenafil citrate ultrasonography
下载PDF
Use of color Doppler ultrasonography in the diagnosis of anomalous connection in pancreatobiliary disease 被引量:7
2
作者 Hiroki Kawashima Yoshiki Hirooka +7 位作者 Akihiro Itoh Senju Hashimoto Terutomo Itoh Kazuo Hara Akira Kanamori Naoki Ohmiya Yasumasa Niwa Hidemi Goto 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第7期1018-1022,共5页
AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallb... AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening. 展开更多
关键词 Color doppler ultrasonography Anomalous connection in pancreatobiliary disease Gallbladder cancer Gallbladder wall blood flow Endoscopic ultrasonography
下载PDF
Hemodynamics in the portal vein evaluated by pulse wave Doppler ultrasonography in patients with chronic hepatitis C treated with interferon 被引量:1
3
作者 Shigeo Nakanishi Katsuya Shiraki +3 位作者 Kouji Yamamoto Mutsumi Koyama Noboru Kimura Takeshi Nakano 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第3期396-399,共4页
AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN) treatment. METHODS: The subjects in this st... AIM: To employ pulse wave Doppler ultrasonography to evaluate the changes in portal blood flow velocity in patients with chronic hepatitis C (CHC) receiving interferon (IFN) treatment. METHODS: The subjects in this study were 14 patients (13 men and l woman) with CHC who received IFN treatment. Portal blood flow velocity was measured in the vessels at the porta hepatis at four time points: before IFN administration (pre-IFN), 2 wk after the start of administration (wk 2), 24 wk after the start of administration (wk 24, i.e., the end of IFN administration), and 24 wk after the end of administration (wk 48). RESULTS: The patients with CHC in whom IFN treatment resulted in complete elimination or effective elimination of viruses showed a significant increase in portal blood flow velocity at the end of IFN treatment compared with that before IFN treatment. In contrast, when IFN was ineffective, no significant increase in portal blood flow velocity was observed at wk 24 or 48 compared with the pre-IFN value. In addition, the patients with CHC in whom IFN was ineffective showed significantly lower portal blood flow velocity values than control subjects at all measurement time points. CONCLUSION: Pulse wave Doppler ultrasonography is a noninvasive and easily performed method for evaluating the effects of IFN treatment in patients with CHC. This technique is useful for measuring portal blood flow velocity before and 24 wk after IFN administration in order to evaluate the changes over time, thus assessing the effectiveness of IFN treatment. 展开更多
关键词 Chronic Hepatitis C INTERFERON Pulsed-wave doppler ultrasonography Portal Vein HEMODYNAMICS
下载PDF
COLOR DOPPLER ULTRASONOGRAPHY APPEARANCES OF RENAL VEIN THROMBOSIS AND ITS DIAGNOSTIC VALUE 被引量:1
4
作者 Sheng Cai Guang-xi Zhong +3 位作者 Jian-chu Li Yu Xia Hui-jun Li Yu-xin Jiang 《Chinese Medical Sciences Journal》 CAS CSCD 2007年第1期17-21,共5页
Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions... Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11); in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT. 展开更多
关键词 color doppler ultrasonography renal vein thrombosis DIAGNOSIS
下载PDF
A study of the hypoechoic hypertrophic lesions and hypoechoic cancer lesions in hypertrophic prostate inner glands with transrectal color doppler ultrasonography
5
作者 Hui Wang Rui Hou Guang Yang Wenlin Xue Shen Lv 《The Chinese-German Journal of Clinical Oncology》 CAS 2008年第12期732-734,共3页
Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagno... Objective: To observe the sonographic and hemodynamic features of hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands, in order to raise the accuracy of early diagnosis rate for prostate cancer. Methods: 31 cases of hypoechoic hypertrophic lesions and 18 cases of hypoechoic cancer lesions in the hypertrophic prostate inner glands were observed by transrectal ultrasonography and comparatively analyze the shape, edge and the systolic peak velocity (Vs) , resistance index (RI) and pulsatility index (PI) of the lesions. Results: In contrast with hypertrophic group, the cancer group presented irregular shape and unclear edge, and obviously higher Vs, RI and PI. Conclusion: The sonographic appearance and Vs. RI. PI have important value in distinguishing hypoechoic hypertrophic lesions and hypoechoic cancer lesions in the hypertrophic prostate inner glands. 展开更多
关键词 transrectal color doppler ultrasonography inner gland prostate cancer
下载PDF
Value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump by color Doppler ultrasonography
6
作者 Guilong Jin Zhiwei Ding Yuxia Guo Xiangxiang Zhao 《The Chinese-German Journal of Clinical Oncology》 CAS 2008年第11期638-640,共3页
Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results o... Objective: To evaluate the value of identifying and diagnosing mammary carcinoma and non-lactation mastitis lump (NLM) by multicolor Doppler ultrasonography. Methods: We compared and analyzed the examination results of 69 cases of mammary carcinoma proved by surgical pathology and 22 cases of NLM before surgery by multicolor Doppler ultra-sonography. Results: The detection rates of mammary carcinoma and NLM focus by ultrasonic examining were 100%. The shape, envelope, foul line, blood stream between sound and image of two diseases were similar. Of the two diseases, the representation with slight calcification in lump, lower echo in low echo, bloodstream distribution and resistance were different. Conclusion: By analyzing the sound and image representation of mammary lump, we find color Doppler ultrasonography has significant value in identifying and diagnosing mammary carcinoma and non-lactation mastitis lump. 展开更多
关键词 mammary carcinoma non-lactation mastitis lump (NLM) color doppler ultrasonography
下载PDF
The value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications 被引量:7
7
作者 Dao-Zhong Huang Gui-Rong Le +4 位作者 Qing-Ping Zhang Kai-Yan Li Qi-Fa Ye Wei Zhu Yun-Chao Chen the Department of Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2003年第1期54-58,共5页
OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation... OBJECTIVE: To assess the value of color Doppler ultrasonography in monitoring normal orthotopic liver transplantation and postoperative complications. METHODS: Forty-one patients after orthotopic liver transplantation were examined by using color Doppler flow imaging to observe the hepatic blood flow and change of ultrasonography of the hepatic parenchyma and bile duct. The measured indexes included maximum blood flow velocity, time-average blood flow velocity (TAV), resistance index (RI) and diameter of the bile duct. RESULTS: Among 41 patients, 17 (41.5%) suffered from liver transplant rejection. Of the 17 patients, 13 (76.4%) showed decrease of TAV of the portal vein, 15 (88.25%) low-amplitude single-phase serrated wave or negative biphasic wave of the hepatic vein, 9 (52.9%) increased hepatic arterial RI, and 5 (29.4%) slightly dilated bile duct. Sonography showed disappearance of the hepatic artery blood flow around the portal vein in 5 (12.2%) of the 41 patients with hepatic artery thrombosis in the postoperative period. Slight dilatation of the intrahepatic bile duct was found in 3 (7.3%) of the 41 patients in the early postoperational period and it normalized within 2 weeks. Ultrasonography of 20 patients (48.8%) revealed a visible dilatation of the intrahepatic bile duct, which was worsening gradually. The causes of bile duct dilatation included biliary stricture in 2 patients (10%), stone in 15 patients (75%) and others in 3 patients (15%). CONCLUSIONS: Color Doppler ultrasonography is valuable for monitoring normal liver transplantation and postoperative complications. 展开更多
关键词 ultrasonography doppleR COLOR liver transplantation COMPLICATION
下载PDF
Transcranial Doppler ultrasonography: From methodology to major clinical applications 被引量:10
8
作者 Antonello D'Andrea Marianna Conte +11 位作者 Massimo Cavallaro Raffaella Scarafile Lucia Riegler Rosangela Cocchia Enrica Pezzullo Andreina Carbone Francesco Natale Giuseppe Santoro Pio Caso Maria Giovanna Russo Eduardo Bossone Raffaele Calabrò 《World Journal of Cardiology》 CAS 2016年第7期383-400,共18页
Non-invasive Doppler ultrasonographic study of cerebral arteries [transcranial Doppler(TCD)] has been extensively applied on both outpatient and inpatient settings. It is performed placing a low-frequency(≤ 2 MHz) tr... Non-invasive Doppler ultrasonographic study of cerebral arteries [transcranial Doppler(TCD)] has been extensively applied on both outpatient and inpatient settings. It is performed placing a low-frequency(≤ 2 MHz) transducer on the scalp of the patient over specific acoustic windows, in order to visualize the intracranial arterial vessels and to evaluate the cerebral blood flow velocity and its alteration in many different conditions. Nowadays the most widespread indication for TCD in outpatient setting is the research of right to left shunting, responsable of so called "paradoxical embolism", most often due to patency of foramen ovale which is responsable of the majority of cryptogenic strokes occuring in patients younger than 55 years old. TCD also allows to classify the grade of severity of such shunts using the so called "microembolic signal grading score". In addition TCD has found many useful applications in neurocritical care practice. It is useful on both adults and children for day-to-day bedside assessment of critical conditions including vasospasm in subarachnoidal haemorrhage(caused by aneurysm rupture or traumatic injury), traumatic brain injury, brain stem death. It is used also to evaluate cerebral hemodynamic changes after stroke. It also allows to investigate cerebral pressure autoregulation and for the clinical evaluation of cerebral autoregulatory reserve. 展开更多
关键词 Transcranial doppler ultrasonography Lindegaard ratio PARADOXICAL EMBOLISM Microembolic signals Middle cerebral artery Patent foramen ovale CRYPTOGENIC STROKE VASOSPASM Acute SUBARACHNOID hemorrhage Ischemic STROKE
下载PDF
Postoperative complications in patients with portal vein thrombosis after liver transplantation:Evaluation with Doppler ultrasonography 被引量:11
9
作者 Yi-Ping Jia Qiang Lu +7 位作者 Shu Gong Bu-Yun Ma Xiao-Rong Wen Yu-Lan Peng Ling Lin Hong-Yan Chen Li Qiu Yan Luo 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第34期4636-4640,共5页
AIM: To study the postoperative complications in patients with preoperative portal vein thrombosis (PVT) undergoing liver transplantation (LT) and to evaluate the complications with Doppler ultrasonography.METHOD... AIM: To study the postoperative complications in patients with preoperative portal vein thrombosis (PVT) undergoing liver transplantation (LT) and to evaluate the complications with Doppler ultrasonography.METHODS: Retrospective studies were performed on 284 patients undergoing LT (286 LT) with respect to pre- and postoperative clinical data and Doppler ultrasonography. According to the presence and grade of preoperative PVT, 286 LTs were divided into three groups: complete PVT (c-PVT), partial PVT (p-PVT) and non-PVT, with 22, 30 and 234 LTs, respectively. Analyses were carried out to compare the incidence of early postoperative complications.RESULTS: PVT, inferior vena cava (IVC) thrombosis, hepatic artery thrombosis (HAT) and biliary complications were found postoperatively. All complications were detected by routine Doppler ultrasonography and diagnoses made by ultrasound were confirmed by clinical data or/and other imaging studies. Nine out of 286 LTs had postoperative PVT. The incidence of the c-Pv-r group was 22.7%, which was higher than that of the p-Pv-r group (3.3%, P 〈 0.05) and non- PVT group (1.3%, P 〈 0.005). No difference was found between the p-PVT and non-PVT groups (P 〉 0.25). Of the 9 cases with postoperative PVT, recanalizations were achieved in 7 cases after anticoagulation under the guidance of ultrasound, 1 case received portal vein thrombectomy and 1 case died of acute injection. Ten LTs had postoperative 1VC thrombosis. The c-PVT group had a higher incidence of IVC thrombosis than the non- PVT group (9.1% vs 2.6%, P 〈 0.05); no significant difference was found between either the c-PV-T and p-PVT groups (9.1% vs 6.7%, P 〉 0.5) or between the p-PVT and non-PVT groups (P 〉 0.25). Nine cases with IVC thrombosis were cured by anticoagulation under the guidance of ultrasound, and 1 case gained natural cure without any medical treatment after 2 mo. HAT was found in 2 non-PVT cases, giving a rate of 0.7% among 286 LTs. Biliary complications were seen in 12 LTs. The incidence of biliary complications in the c-PVT, p-PVT and non-PVT groups was 9.1%, 3.3% and 4.3%, respectively (P 〉 0.25 for all), among which 2 stenosis led retransplantations and others were controlled by relative therapy.CONCLUSION: C-PVT patients tend to have a higher incidence of PVT and IVC thrombosis than non- PVT patients after LT. The incidence of postoperative complications in p-PVT patients does not differ from that of non-PVT patients, A relatively low incidence of HAT was seen in our study, Doppler ultrasonography is a convenient and efficient method for detecting posttransplant complications and plays an important role in guiding treatment. 展开更多
关键词 Portal vein thrombosis Liver transplantation Postoperative complications doppler ultrasonography
下载PDF
Basket pattern blood flow signals discovered in a case of splenic hamartoma by power Doppler ultrasonography 被引量:5
10
作者 Shigeo Nakanishi Katsuya Shiraki +8 位作者 Kouji Yamamoto Takeshi Nakano Mutsumi Koyama Takatsugu Yano Takayuki Sanda Hisao Tamaki Tadanori Hirano Kazuo Fukudome Akinori Ishihara 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第33期5235-5238,共4页
We present the gray-scale ultrasonography (GSUS), power Doppler ultrasonography (PDUS), abdominal computed tomography (CT), and magnetic resonance imaging (MRI) findings for a case of splenic hamartoma in a 27... We present the gray-scale ultrasonography (GSUS), power Doppler ultrasonography (PDUS), abdominal computed tomography (CT), and magnetic resonance imaging (MRI) findings for a case of splenic hamartoma in a 27-year-old man, showing a φ 50 mm homogeneous, iso- and hypo-echoic splenic mass with evidence of a small plural cystic lesion. This splenic hamartoma showed increased vascularity on power Doppler sonograms. PDUS showed multiple circular blood flow signals inside the mass (i.e. a basket pattern), which was consistent with the small plural cystic lesion shown by GSUS. Spectral analysis also confirmed arterial and venous flow. CT scans showed that the mass had lowdensity relative to the normal spleen and MRI showed that the mass was isodense, relative to the normal spleen. Therefore, CT and MRI are not useful for the diagnosis of splenic hamartoma. Ultrasonography can be used to diagnose splenic hamartoma without administration of a contrast matedal and therefore is an indispensable method for the diagnosis of splenic hamartoma. 展开更多
关键词 Splenic hamartoma ultrasonography Basketpattern
下载PDF
Graves' Disease Thyroid Color-Flow Doppler Ultrasonography Assessment: Review Article
11
作者 Thiago Adler Ralho Rodrigues dos Santos Rodrigo Otavio Gomes Pina +1 位作者 Marina Taliberti Pereira de Souza Maria Cristina Chammas 《Health》 2014年第12期1487-1496,共10页
Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenc... Graves’ disease, as known today, is an autoimmune, diffuse, chronic disease of thyroid gland, as described by Robert Graves in 1835. It presents genetic predisposition and unknown etiology evidence, which is influenced in its development by several factors, including environment (dietary iodine intake, stress, drugs and infections). The disease is characterized by one or more changes: hyperthyroidism, goiter, ophthalmopathy, skin changes and pretibial myxedema, around 5% less common, and other symptoms 90% to 95%. One of the most relevant clinical practice aspects in Graves’ disease patients management is to distinguish Graves’ disease in initial phase, from other types of destructive thyrotoxicosis, in addition to evaluate therapeutic methods and efficient follow up, as well as predict early recurrence or remission of disease. Scintigraphy with pertechnetate (99 mTc) and TSH levels dosage are considered the choice for this purpose. However, they present some technical difficulties, as they are not widely available and have contraindications. In this scenario, thyroid color-flow doppler ultrasonography (US Doppler) presents a viable alternative, as a widely available, low cost, non-invasive and radiation free method, providing initial diagnosis and patients with Graves’ disease follow up. In adittion, this method is used in differential diagnosis with other causes of thyrotoxicosis in the early stage. 展开更多
关键词 THYROID Graves’ Disease ultrasonography Color-Flow doppleR
下载PDF
Relationship between Microscopic Hematuria and Inferior Vena Cava Reflux on Color Doppler Ultrasonography
12
作者 Kimio Sugaya Saori Nishijima +1 位作者 Katsumi Kadekawa Katsuhiro Ashitomi 《Open Journal of Urology》 2013年第8期299-303,共5页
We examined the relationship between microscopic hematuria and inferior vena cava (IVC) reflux. Transabdominal color Doppler ultrasonography of the IVC was performed in the supine position with the convex probe positi... We examined the relationship between microscopic hematuria and inferior vena cava (IVC) reflux. Transabdominal color Doppler ultrasonography of the IVC was performed in the supine position with the convex probe positioned perpendicular to the upper abdominal wall, and the extent of reflux into the IVC with each heart beat was examined near the diaphragm. A total of 171 patients were studied who had no diseases that could cause hematuria, and no symptomatic gross hematuria. The relationship between the existence and severity of IVC reflux and urine occult blood was examined. The 98 males included 50 subjects without IVC reflux and 48 with reflux, while the 73 females included 24 without IVC reflux and 49 with IVC reflux, respectively. The occurrence of IVC reflux was unrelated to age, but the prevalence of reflux was significantly higher in females than males. As the grade of IVC reflux increased, there was an increase in the prevalence and the severity of hematuria in both males and females. In conclusion, IVC reflux could be related to the occurrence of microscopic hematuria. Renal or urinary tract congestion secondary to IVC reflux may be one of the factors contributing to hematuria. 展开更多
关键词 INFERIOR Vena Cava REFLUX ultrasonography HEMATURIA
下载PDF
Accuracy of Doppler Ultrasonography in Assessment of Lower Extremity Peripheral Arterial Diseases
13
作者 Samia Perwaiz Khan   SafiaIzhar 《International Journal of Clinical Medicine》 2018年第6期505-512,共8页
Doppler ultrasound scan is a non-invasive, cheap and convenient tool and it complements angiography, Computed tomography angiography (CTA), magnetic resonance angiography (MRA) and catheter digital subtraction angiogr... Doppler ultrasound scan is a non-invasive, cheap and convenient tool and it complements angiography, Computed tomography angiography (CTA), magnetic resonance angiography (MRA) and catheter digital subtraction angiography (DSA) in screening, diagnosis, treatment and follow-up of peripheral vascular diseases. Symptoms of peripheral vascular diseases are becoming more common due to rise in incidence of diseases and risk factors (diabetes mellitus, dyslipidemias, smoking, sedentary lifestyle). Due to limited availability of highly specific tools such as CT angiography, magnetic resonance angiography (MRA) and DSA (digital subtraction angiography) in many developing countries, doppler ultrasound is gaining more importance. Early determination of peripheral arterial diseases is beneficial in prevention of complications as severity increases may cause intermittent claudication, pain, tissue loss, including ulceration and gangrene (as the diseases progresses) and early management of arteriosclerosis will be beneficial to prevent these complications. 展开更多
关键词 PAD PERIPHERAL ARTERIAL Diseases doppleR ultrasonography T2DM Type 2Diabetes MELLITUS
下载PDF
Relationship between neonatal respiratory distress syndrome pulmonary ultrasonography and respiratory distress score,oxygenation index,and chest radiography grading
14
作者 Hai Yang Li-Jun Gao +5 位作者 Jing Lei Qiang Li Liu Cui Xiao-Hua Li Wu-Xuan Yin Sen-Hua Tian 《World Journal of Clinical Cases》 SCIE 2024年第20期4154-4165,共12页
BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a ... BACKGROUND Accurate condition assessment is critical for improving the prognosis of neonatal respiratory distress syndrome(RDS),but current assessment methods for RDS pose a cumulative risk of harm to neonates.Thus,a less harmful method for assessing the health of neonates with RDS is needed.AIM To analyze the relationships between pulmonary ultrasonography and respiratory distress scores,oxygenation index,and chest X-ray grade of neonatal RDS to identify predictors of neonatal RDS severity.METHODS This retrospective study analyzed the medical information of 73 neonates with RDS admitted to the neonatal intensive care unit of Liupanshui Maternal and Child Care Service Center between April and December 2022.The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest Xray grade of each newborn before and after treatment were collected.Spearman correlation analysis was performed to determine the relationships among these values and neonatal RDS severity.RESULTS The pulmonary ultrasonography score,respiratory distress score,oxygenation index,and chest X-ray RDS grade of the neonates were significantly lower after treatment than before treatment(P<0.05).Spearman correlation analysis showed that before and after treatment,the pulmonary ultrasonography score of neonates with RDS was positively correlated with the respiratory distress score,oxygenation index,and chest X-ray grade(ρ=0.429–0.859,P<0.05).Receiver operating characteristic curve analysis indicated that pulmonary ultrasonography screening effectively predicted the severity of neonatal RDS(area under the curve=0.805–1.000,P<0.05).CONCLUSION The pulmonary ultrasonography score was significantly associated with the neonatal RDS score,oxygenation index,and chest X-ray grade.The pulmonary ultrasonography score was an effective predictor of neonatal RDS severity. 展开更多
关键词 Neonatal respiratory distress syndrome Pulmonary ultrasonography ultrasonography score Respiratory distress score Oxygenation index Chest X-ray grading
下载PDF
Interventional endoscopic ultrasonography for pancreatic cancer 被引量:2
15
作者 Kazuo Hara Kenji Yamao +7 位作者 Nobumasa Mizuno Susumu Hijioka Akira Sawaki Masahiro Tajika Hiroki Kawai Shinya Kondo Yasuhiro Shimizu Yasumasa Niwa 《World Journal of Clinical Oncology》 CAS 2011年第2期108-114,共7页
Endoscopic ultrasonography(EUS)represents the combination of endoscopy and intraluminal ultrasonography.This allows use of a high-frequency transducer(5-20 MHz)that,due to the short distance to the target lesion,provi... Endoscopic ultrasonography(EUS)represents the combination of endoscopy and intraluminal ultrasonography.This allows use of a high-frequency transducer(5-20 MHz)that,due to the short distance to the target lesion,provides ultrasonographic images of higher resolution than those obtained from other imaging modalities,including multiple-detector-row-computed tomography,magnetic resonance imaging,and positron emission tomography.EUS is now a widely accepted modality for diagnosing pancreatic diseases.However,the most important limitation of EUS has been the lack of specificity in differentiating between benign and malignant changes.In 1992,EUS-guided fine needle aspiration(FNA)of lesions in the pancreas head was introduced into clinical practice,using a curved linear-array echoendoscope.Since then,EUS has evolved from EUS imaging to EUSFNA and wider applications.Interventional EUS for pancreatic cancer includes EUS-FNA,EUS-guided fine needle injection,EUS-guided biliary drainage and anastomosis,EUS-guided celiac neurolysis,radiofrequency ablation,brachytherapy,and delivery of a growing number of anti-tumor agents.This review focuses on interventional EUS,including EUS-FNA and therapeutic EUS for pancreatic cancer. 展开更多
关键词 ENDOSCOPIC ultrasonography-biliary drainage ENDOSCOPIC ultrasonography-choledochoduodenostomy ENDOSCOPIC ultrasonography-fine needle ASPIRATION ENDOSCOPIC ultrasonography-guided biliary drainage INTERVENTIONAL ENDOSCOPIC ultrasonography
下载PDF
Endoscopic ultrasonography-related diagnostic accuracy and clinical significance on small rectal neuroendocrine neoplasms 被引量:1
16
作者 Jun Weng Yu-Fan Chen +5 位作者 Shu-Han Li Yan-Hua Lv Ruo-Bing Chen Guo-Liang Xu Shi-Yong Lin Kun-Hao Bai 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期774-778,共5页
This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal sube... This research aimed to examine the diagnostic accuracy and clinical significance of endoscopic ultrasonography(EUS)in the context of small rectal neuroendocrine neoplasms(NENs).A total of 108 patients with rectal subepithelial lesions(SELs)with a diameter of<20 mm were included in the analysis.The diagnosis and depth assessment of EUS was compared to the histology findings.The prevalence of NENs in rectal SELs was 78.7%(85/108).The sensitivity of EUS in detecting rectal NENs was 98.9%(84/85),while the specificity was 52.2%(12/23).Overall,the diagnostic accuracy of EUS in identifying rectal NENs was 88.9%(96/108).The overall accuracy rate for EUS in assessing the depth of invasion in rectal NENs was 92.9%(78/84).Therefore,EUS demonstrates reasonable diagnostic accuracy in detecting small rectal NENs,with good sensitivity but inferior specificity.EUS may also assist physicians in assessing the depth of invasion in small rectal NENs before endoscopic excision. 展开更多
关键词 Rectal neuroendocrine neoplasms Endoscopic ultrasonography DIAGNOSIS Depth of invasion
下载PDF
Double contrast-enhanced ultrasonography improves diagnostic accuracy of T staging compared with multi-detector computed tomography in gastric cancer patients 被引量:1
17
作者 Yan-Fen Xu Hui-Yun Ma +4 位作者 Gui-Ling Huang Yu-Ting Zhang Xue-Yan Wang Ming-Jie Wei Xiao-Qing Pei 《World Journal of Gastroenterology》 SCIE CAS 2024年第23期3005-3015,共11页
BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and ... BACKGROUND Gastric cancer(GC)is the most common malignant tumor and ranks third for cancer-related deaths among the worldwide.The disease poses a serious public health problem in China,ranking fifth for incidence and third for mortality.Knowledge of the invasive depth of the tumor is vital to treatment decisions.AIM To evaluate the diagnostic performance of double contrast-enhanced ultrasonography(DCEUS)for preoperative T staging in patients with GC by comparing with multi-detector computed tomography(MDCT).METHODS This single prospective study enrolled patients with GC confirmed by preoperative gastroscopy from July 2021 to March 2023.Patients underwent DCEUS,including ultrasonography(US)and intravenous contrast-enhanced ultrasonography(CEUS),and MDCT examinations for the assessment of preoperative T staging.Features of GC were identified on DCEUS and criteria developed to evaluate T staging according to the 8th edition of AJCC cancer staging manual.The diagnostic performance of DCEUS was evaluated by comparing it with that of MDCT and surgical-pathological findings were considered as the gold standard.RESULTS A total of 229 patients with GC(80 T1,33 T2,59 T3 and 57 T4)were included.Overall accuracies were 86.9%for DCEUS and 61.1%for MDCT(P<0.001).DCEUS was superior to MDCT for T1(92.5%vs 70.0%,P<0.001),T2(72.7%vs 51.5%,P=0.041),T3(86.4%vs 45.8%,P<0.001)and T4(87.7%vs 70.2%,P=0.022)staging of GC.CONCLUSION DCEUS improved the diagnostic accuracy of preoperative T staging in patients with GC compared with MDCT,and constitutes a promising imaging modality for preoperative evaluation of GC to aid individualized treatment decision-making. 展开更多
关键词 Double contrast-enhanced ultrasonography Multi-detector computed tomography Gastric cancer T staging
下载PDF
Doppler Study of Uterine Artery and Ultrasonography of Endometrial Thickness in Perimenopausal and Postmenopausal Bleeding
18
作者 Shaimaa Belal Manal Abdel-Wanees Al-Sayed +1 位作者 Hany Mahmoud Abd El Hamid Hesham Mohammed Hamed 《Open Journal of Obstetrics and Gynecology》 2022年第4期309-322,共14页
Background: Transvaginal color Doppler sonography of the uterine artery has been reported useful for evaluation of abnormal uterine bleeding in peri-/post-menopausal women. It may differentiate physiological from mali... Background: Transvaginal color Doppler sonography of the uterine artery has been reported useful for evaluation of abnormal uterine bleeding in peri-/post-menopausal women. It may differentiate physiological from malignant endometrial changes. Objective: Evaluating the endometrial thickness and uterine artery Doppler as an initial diagnostic tool to identify patients with abnormal endometrial pathology. Methods: This is a prospective case control study consisted of total 50 women with peri-(n = 35) and post-(n = 15) menopausal bleeding, with 20 women consisting control group (no bleeding) (peri-(n = 10) and post-menopausal (n = 10)). Double layer endometrial thickness and uterine-artery-Doppler waveforms were measured, with the latter being S/D ratio, RI and PI. These were related to histological findings (endometrial biopsy). Result: Patients with abnormal uterine bleeding (both peri- and postmenopausal) had a significantly higher mean endometrial thickness than the control women. Study group showed a significantly lower value of all Doppler indices (S/D ratio, RI and PI). In study group, patients with malignant endometrial pathology showed significantly thicker endometrium and significantly lower Doppler indices than those with benign pathology. Conclusion: The combination of endometrial thickness and uterine artery color Doppler pattern might predict uterine endometrial malignancy, although whether it can discriminate (screen) patients requiring endometrial biopsy is not evident. Further study is needed. 展开更多
关键词 doppler Study Uterine Artery ultrasonography Endometrial Thickness
下载PDF
Intraoperative cholangio-ultrasonography(IOCUS)during hepatectomy with resection of the biliary confluence:An effective alternative to intraoperative cholangiography
19
作者 Daniele Del Fabbro Fabio Procopio +5 位作者 Jacopo Galvanin Guido Costa Simone Famularo Angela Palmisano Matteo Donadon Guido Torzilli 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第4期417-420,共4页
Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgi... Intraoperative ultrasonography(IOUS)in hepatobiliary surgery is well known as an essential tool for radical and safe hepatectomies,allowing to perform parenchymal sparing surgery and,as consequence,to expand the surgical indications for patients otherwise considered unresectable.Nevertheless,since many years,despite its effectiveness in the study of vascular anatomy of the liver,the gold standard for the assessment of biliary anatomy during surgery is intraoperative cholangiography(IOC),which is used for the validation of preoperative imaging as well as for guiding reconstruction in case of bile duct injury or resection. 展开更多
关键词 anatomy BILIARY ultrasonography
下载PDF
Beta-HCG Levels and Ovarian Ultrasonography Results among Non-Pregnant Women of Reproductive Age in Port Harcourt, Nigeria: A Cross-Sectional Study
20
作者 Celine C. Agonsi Francis Anacletus +2 位作者 Joel Aluko Chinemerem Eleke Joy C. Samuel 《Journal of Biosciences and Medicines》 2024年第5期233-241,共9页
Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian ca... Background: Certain ovarian cancers that were previously common in postmenopausal women are now increasingly observed in women of reproductive age. The research on using β-HCG as a diagnostic biomarker for ovarian cancer in women of reproductive age is ongoing. Aim: This study assessed the level of serum β-HCG in non-pregnant women of reproductive age and determined its potential association with suspicious ovarian ultrasonography results. Methods: The study was conducted in Port Harcourt, Nigeria. This study adopted a cross-sectional design on a quota sample of 224 case notes of women aged 18 - 40 years obtained from eight diagnostic centres. A data extraction form was used for data collection. Data analysis employed descriptive statistics, Chi-square, Fisher’s exact test, and Odds Ratio at 95% confidence and 5% significance levels. Results: About 5.8% of the participants exhibited detectable levels of serum β-HCG above 5 IU/L (World Health Organization reference) at a mean concentration of 5.87 (±1.75) IU/L. About 4.0% of the participants had suspicious ovarian lesions identified through ultrasonography. Participants with elevated serum β-HCG levels above the WHO reference were 59 times more likely to have suspicious ovarian lesions (Odds ratio: 59.4, 95%CI: 12.3 - 287.8, p β-HCG level and age (p = 0.041) as well as parity (p Conclusion: Serum β-HCG levels above the WHO reference in non-pregnant women were associated with suspicious ovarian lesions. More rigorous primary research, systematic reviews, and meta-analyses are needed to confirm the findings of this study. 展开更多
关键词 Biomarkers Ovarian Cancer PREGNANCY ultrasonography
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部