Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast ...Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate.展开更多
Objective:We propose a solution that is backed by cloud computing,combines a series of AI neural networks of computer vision;is capable of detecting,highlighting,and locating breast lesions from a live ultrasound vide...Objective:We propose a solution that is backed by cloud computing,combines a series of AI neural networks of computer vision;is capable of detecting,highlighting,and locating breast lesions from a live ultrasound video feed,provides BI-RADS categorizations;and has reliable sensitivity and specificity.Multiple deep-learning models were trained on more than 300,000 breast ultrasound images to achieve object detection and regions of interest classification.The main objective of this study was to determine whether the performance of our Al-powered solution was comparable to that of ultrasound radiologists.Methods:The noninferiority evaluation was conducted by comparing the examination results of the same screening women between our AI-powered solution and ultrasound radiologists with over 10 years of experience.The study lasted for one and a half years and was carried out in the Duanzhou District Women and Children's Hospital,Zhaoqing,China.1,133 females between 20 and 70 years old were selected through convenience sampling.Results:The accuracy,sensitivity,specificity,positive predictive value,and negative predictive value were 93.03%,94.90%,90.71%,92.68%,and 93.48%,respectively.The area under the curve(AUC)for all positives was 0.91569 and the AUC for all negatives was 0.90461.The comparison indicated that the overall performance of the AI system was comparable to that of ultrasound radiologists.Conclusion:This innovative AI-powered ultrasound solution is cost-effective and user-friendly,and could be applied to massive breast cancer screening.展开更多
In the current study, we sought to evaluate the diagnostic efficacies of conventional ultrasound(US), contrastenhanced US(CEUS), combined US and CEUS and magnetic resonance imaging(MRI) in detecting focal solid ...In the current study, we sought to evaluate the diagnostic efficacies of conventional ultrasound(US), contrastenhanced US(CEUS), combined US and CEUS and magnetic resonance imaging(MRI) in detecting focal solid breast lesions. Totally 117 patients with 120 BI-RADS category 4A-5 breast lesions were evaluated by conventional US and CEUS, and MRI, respectively. SonoVue was used as contrast agent in CEUS and injected as an intravenous bolus; nodule scan was performed 4 minutes after bolus injection. A specific sonographic quantification software was used to obtain color-coded maps of perfusion parameters for the investigated lesion, namely the time-intensity curve.The pattern of contrast enhancement and related indexes regarding the time-intensity curve were used to describe the lesions, comparatively with pathological results. Histopathologic examination revealed 46 benign and 74 malignant lesions. Sensitivity, specificity, and accuracy of US in detecting malignant breast lesions were 90.14%, 95.92%, and 92.52%, respectively. Meanwhile, CE-MRI showed sensitivity, specificity, and accuracy of 88.73%, 95.92%, and91.67%, respectively. The area under the ROC curve for combined US and CEUS in discriminating benign from malignant breast lesions was 0.936, while that of MRI was 0.923, with no significant difference between them, as well as among groups. The time-intensity curve of malignant hypervascular fibroadenoma and papillary lesions mostly showed a fast-in/fast-out pattern, with no good correlation between them(kappa 〈0.20). In conclusion, the combined use of conventional US and CEUS displays good agreement with MRI in differentiating benign from malignant breast lesions.展开更多
文摘Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate.
文摘Objective:We propose a solution that is backed by cloud computing,combines a series of AI neural networks of computer vision;is capable of detecting,highlighting,and locating breast lesions from a live ultrasound video feed,provides BI-RADS categorizations;and has reliable sensitivity and specificity.Multiple deep-learning models were trained on more than 300,000 breast ultrasound images to achieve object detection and regions of interest classification.The main objective of this study was to determine whether the performance of our Al-powered solution was comparable to that of ultrasound radiologists.Methods:The noninferiority evaluation was conducted by comparing the examination results of the same screening women between our AI-powered solution and ultrasound radiologists with over 10 years of experience.The study lasted for one and a half years and was carried out in the Duanzhou District Women and Children's Hospital,Zhaoqing,China.1,133 females between 20 and 70 years old were selected through convenience sampling.Results:The accuracy,sensitivity,specificity,positive predictive value,and negative predictive value were 93.03%,94.90%,90.71%,92.68%,and 93.48%,respectively.The area under the curve(AUC)for all positives was 0.91569 and the AUC for all negatives was 0.90461.The comparison indicated that the overall performance of the AI system was comparable to that of ultrasound radiologists.Conclusion:This innovative AI-powered ultrasound solution is cost-effective and user-friendly,and could be applied to massive breast cancer screening.
基金supported by the Natural Science Foundation of Jiangsu University(14KJB320003)
文摘In the current study, we sought to evaluate the diagnostic efficacies of conventional ultrasound(US), contrastenhanced US(CEUS), combined US and CEUS and magnetic resonance imaging(MRI) in detecting focal solid breast lesions. Totally 117 patients with 120 BI-RADS category 4A-5 breast lesions were evaluated by conventional US and CEUS, and MRI, respectively. SonoVue was used as contrast agent in CEUS and injected as an intravenous bolus; nodule scan was performed 4 minutes after bolus injection. A specific sonographic quantification software was used to obtain color-coded maps of perfusion parameters for the investigated lesion, namely the time-intensity curve.The pattern of contrast enhancement and related indexes regarding the time-intensity curve were used to describe the lesions, comparatively with pathological results. Histopathologic examination revealed 46 benign and 74 malignant lesions. Sensitivity, specificity, and accuracy of US in detecting malignant breast lesions were 90.14%, 95.92%, and 92.52%, respectively. Meanwhile, CE-MRI showed sensitivity, specificity, and accuracy of 88.73%, 95.92%, and91.67%, respectively. The area under the ROC curve for combined US and CEUS in discriminating benign from malignant breast lesions was 0.936, while that of MRI was 0.923, with no significant difference between them, as well as among groups. The time-intensity curve of malignant hypervascular fibroadenoma and papillary lesions mostly showed a fast-in/fast-out pattern, with no good correlation between them(kappa 〈0.20). In conclusion, the combined use of conventional US and CEUS displays good agreement with MRI in differentiating benign from malignant breast lesions.