Nearly 91% of organic pollutants in Hong Kong leachate could be effectively removed by the UASB(upflow anaerobic sludge blanket) process followed by the fenton coagulation. The COD (chemical oxygen demand) of leachate...Nearly 91% of organic pollutants in Hong Kong leachate could be effectively removed by the UASB(upflow anaerobic sludge blanket) process followed by the fenton coagulation. The COD (chemical oxygen demand) of leachate was lowered from an average of 5620 mg/L to 1910 mg/L after the UASB treatment at 37℃, and was further lowered to 513 mg/L after fenton coagulation. The remaining refractory residues could be further removed by photochemical oxidation with the addition of H 2O 2. The BOD/COD ratio was greatly increased from 0.062 to 0.142, indicating the biodegradability of organic residues was improved. The photochemical oxidation for the fenton\|coagulation supernatant was most effective at pH 3\_4, with the addition of 800 mg/L of H 2O 2, and UV radiation time of 30 minutes. The final effluent contained only 148 mg/L of COD, 21 mg/L of BOD(biochemical oxygen demand) and 56 mg/L of TOC (total organic carbon).展开更多
4-Chlorophenol (4-CP) solution was treated by dual-frequency ultrasound inconjunction with Fenton reagent, and obvious improvement in the 4-CP degradation rate was observedin this advanced oxidation process. Experimen...4-Chlorophenol (4-CP) solution was treated by dual-frequency ultrasound inconjunction with Fenton reagent, and obvious improvement in the 4-CP degradation rate was observedin this advanced oxidation process. Experimental results showed that ultrasonic intensity,saturating gas and pH value affected greatly the 4-CP removal rate. Among four different saturatinggases (Ar, O_2, air and N_2), 4-CP degradation with Ar-saturated solution was the best. However, inthe view of practical wastewater treatment, using oxygen as the saturating gas would be moreeconomical. The addition of Fenton reagent followed the first-order kinetics and increased the 4-CPdegradation rate. The 4-CP removal rate increased by around 126% within 15 min treatment. Thesynergetic effect of dual-frequency ultrasound with Fenton reagent on 4-CP degradation was obviouslyobserved.展开更多
Central composite design (CCD), the most popular design ofresponse surface methodology (RSM), was employed to investigate theeffect of total organic carbon (TOC) ratio of high molecular weightorganic matter (HMW) to l...Central composite design (CCD), the most popular design ofresponse surface methodology (RSM), was employed to investigate theeffect of total organic carbon (TOC) ratio of high molecular weightorganic matter (HMW) to low molecular weight organic matter (LMW),the LMW strength and molar ratio of hydrogen peroxide to ferrous ionon landfill leachate treatment by Fenton process. Based on theexperimental data, a response surface quadratic model in terms ofactual factors was obtained through analysis of variance (ANOVA).展开更多
文摘Nearly 91% of organic pollutants in Hong Kong leachate could be effectively removed by the UASB(upflow anaerobic sludge blanket) process followed by the fenton coagulation. The COD (chemical oxygen demand) of leachate was lowered from an average of 5620 mg/L to 1910 mg/L after the UASB treatment at 37℃, and was further lowered to 513 mg/L after fenton coagulation. The remaining refractory residues could be further removed by photochemical oxidation with the addition of H 2O 2. The BOD/COD ratio was greatly increased from 0.062 to 0.142, indicating the biodegradability of organic residues was improved. The photochemical oxidation for the fenton\|coagulation supernatant was most effective at pH 3\_4, with the addition of 800 mg/L of H 2O 2, and UV radiation time of 30 minutes. The final effluent contained only 148 mg/L of COD, 21 mg/L of BOD(biochemical oxygen demand) and 56 mg/L of TOC (total organic carbon).
基金Partly supported by the National Natural Science Foundation of China (No. 20176053)Academic Foundation of Zhejiang University of Technology (No. 20040004).
文摘4-Chlorophenol (4-CP) solution was treated by dual-frequency ultrasound inconjunction with Fenton reagent, and obvious improvement in the 4-CP degradation rate was observedin this advanced oxidation process. Experimental results showed that ultrasonic intensity,saturating gas and pH value affected greatly the 4-CP removal rate. Among four different saturatinggases (Ar, O_2, air and N_2), 4-CP degradation with Ar-saturated solution was the best. However, inthe view of practical wastewater treatment, using oxygen as the saturating gas would be moreeconomical. The addition of Fenton reagent followed the first-order kinetics and increased the 4-CPdegradation rate. The 4-CP removal rate increased by around 126% within 15 min treatment. Thesynergetic effect of dual-frequency ultrasound with Fenton reagent on 4-CP degradation was obviouslyobserved.
基金Supported by the Delaware Solid Waste Authority, Dover DE, USA and China Scholarship Council (No. 97842039).
文摘Central composite design (CCD), the most popular design ofresponse surface methodology (RSM), was employed to investigate theeffect of total organic carbon (TOC) ratio of high molecular weightorganic matter (HMW) to low molecular weight organic matter (LMW),the LMW strength and molar ratio of hydrogen peroxide to ferrous ionon landfill leachate treatment by Fenton process. Based on theexperimental data, a response surface quadratic model in terms ofactual factors was obtained through analysis of variance (ANOVA).