A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ...[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.展开更多
Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids we...Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids were based on the American Oil Chemists' Society(AOCS) Official Method Ja7b-91,in which n-hexane/2-propanol/acetate buffer was used as the mobile phase.In order to achieve desired results,gradient elu-tion or buffer solution was used,which made the detection process more complicated.Moreover,water or buffer solution could affect the silica gel column both on its lifespan and the separation efficiency significantly.In this study,different mobile phase and detector were used to simplify EYPC analyzing process instead of using water within the mobile phase.The optimized HPLC operating conditions are as follows:pure methanol as a mobile phase,flow rate of 1.0 ml·min-1,silica gel column(250 mm×4.6 mm,5 μm,Inertsil GLTM),column temperature 30 ℃ and low temperature evaporative light scattering detector(40 ℃,0.35 MPa) as used.Under this optimal condition,the linear relative coefficient of the standard curve is 0.998 and the recovery was in the range of 96.83%-101.58% with a relative standard deviation of 1.79%(n=6).展开更多
A simple high-performance liquid chromatography(HPLC)method coupled with an evaporative light scattering detector(ELSD)was developed for the determination of azithromycin in raw materials and pharmaceutical formulatio...A simple high-performance liquid chromatography(HPLC)method coupled with an evaporative light scattering detector(ELSD)was developed for the determination of azithromycin in raw materials and pharmaceutical formulations(injections,capsules and tablets)without any pretreatment or derivatization step.Azithromycin,degradation products and formulation ingredients were separated efficiently by using the mobile phase consisted of ammonium acetate(0.05 M,pH 8.0)and acetonitrile(60:40,v/v)in an isocratic mode at 0.8 ml/min flow rate.Parameters of ELSD were 60C for evaporation temperature and 50 psi for pressure of carrier gas(air).A logarithmic calibration curve was obtained from 50.93 to 509.30 mg/ml(r¼0.9996)for azithromycin,with the limit of detection(LOD)of 6.75 mg/ml(S/n¼3)and the limit of quantification of 22.50 mg/ml(S/n¼10).The developed method was validated and applied with satisfactory accuracy and precision for the determination of azithromycin in raw materials and pharmaceutical formulations(recovery 99e102%,RSD<1.2%,n¼3).No significant difference(t-test)was found between the results of the developed HPLCeELSD method and the HPLCeUV or microbiological method.展开更多
The signal processing circuits of position sensitive detector(PSD) with alternating light source are presented.The measuring device of PSD with alternating light source can effectively eliminate the interference made ...The signal processing circuits of position sensitive detector(PSD) with alternating light source are presented.The measuring device of PSD with alternating light source can effectively eliminate the interference made by light noise signal.展开更多
Linear alkylbenzene(LAB) will be used as solvent for the liquid scintillator in the central detector of Jiangmen Underground Neutrino Observatory. The sheer size of the detector imposes significant challenges and the ...Linear alkylbenzene(LAB) will be used as solvent for the liquid scintillator in the central detector of Jiangmen Underground Neutrino Observatory. The sheer size of the detector imposes significant challenges and the necessity to further improve the optical transparency of high-quality LAB. In order to study high optical transparencies, we continuously improve our measurement setup and use monochromatic light to measure the attenuation lengths of LAB samples. Moreover, the effects of organic impurities on LAB samples are studied to understand their interaction mechanisms and further improve the optical transparency of LAB.展开更多
As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main me...As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources.The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel.GRAND is the largest neutrino detection array to be built in China.GRANDProto35,as the first stage of the GRAND experiment,is a coincidence array composed of radio antennas and a scintillation detector,the latter of which,as a traditional detector,is used to perform cross-validation with radio detection,thus verifying the radio detection efficiency and enabling study of the background exclusion method.This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35.A package based on GEANT4 was used to simulate the details of the scintillation detector,including the optical properties of its materials,the height of the light guide box,and position inhomogeneity.The surface of the scintillator and the reflective materials used in the detector was optimized,and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied.According to the simulation study,the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface,with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m^(2).The performance of the detector was tested in detail through a coincidence experiment,and the test results showed that the number of photoelectrons collected in the detector was$84 with a time resolution of~1 ns,indicating good performance.The simulation results were consistent with those obtained from the tests,which also verified the reliability of the simulation software.These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.展开更多
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,...A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.展开更多
In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a...In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.展开更多
The evolution of next-generation cellular networks is aimed at creating faster,more reliable solutions.Both the next-generation 6G network and the metaverse require high transmission speeds.Visible light communication...The evolution of next-generation cellular networks is aimed at creating faster,more reliable solutions.Both the next-generation 6G network and the metaverse require high transmission speeds.Visible light communication(VLC)is deemed an important ancillary technology to wireless communication.It has shown potential for a wide range of applications in next-generation communication.Micro light-emitting diodes(μLEDs)are ideal light sources for high-speed VLC,owing to their high modulation bandwidths.In this review,an overview ofμLEDs for VLC is presented.Methods to improve the modulation bandwidth are discussed in terms of epitaxy optimization,crystal orientation,and active region structure.Moreover,electroluminescent white LEDs,photoluminescent white LEDs based on phosphor or quantum-dot color conversion,andμLED-based detectors for VLC are introduced.Finally,the latest high-speed VLC applications and the application prospects of VLC in 6G are introduced,including underwater VLC and artificial intelligence-based VLC systems.展开更多
Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling...Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments.展开更多
This article demonstrates the fabrication of organic-based devices using a low-cost solution-processable technique.A blended heterojunction of chlorine substituted 2D-conjugated polymer PBDB-T-2Cl,and PC71BM supported...This article demonstrates the fabrication of organic-based devices using a low-cost solution-processable technique.A blended heterojunction of chlorine substituted 2D-conjugated polymer PBDB-T-2Cl,and PC71BM supported nanocapsules hy-drate vanadium penta oxides(HVO)as hole transport layer(HTL)based photodetector fabricated on an ITO coated glass sub-strate under ambient condition.The device forms an excellent organic junction diode with a good rectification ratio of~200.The device has also shown excellent photodetection properties under photoconductive mode(at reverse bias)and zero bias for green light wavelength.A very high responsivity of~6500 mA/W and high external quantum efficiency(EQE)of 1400%have been reported in the article.The proposed organic photodetector exhibits an excellent response and recovery time of~30 and~40 ms,respectively.展开更多
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
文摘[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.
文摘Egg yolk phosphatidylcholine(EYPC) is being widely used in food and pharmaceutical industries nowadays owing to its surface activity,pharmaceutical usefulness,and so on.Common determination methods of phospholipids were based on the American Oil Chemists' Society(AOCS) Official Method Ja7b-91,in which n-hexane/2-propanol/acetate buffer was used as the mobile phase.In order to achieve desired results,gradient elu-tion or buffer solution was used,which made the detection process more complicated.Moreover,water or buffer solution could affect the silica gel column both on its lifespan and the separation efficiency significantly.In this study,different mobile phase and detector were used to simplify EYPC analyzing process instead of using water within the mobile phase.The optimized HPLC operating conditions are as follows:pure methanol as a mobile phase,flow rate of 1.0 ml·min-1,silica gel column(250 mm×4.6 mm,5 μm,Inertsil GLTM),column temperature 30 ℃ and low temperature evaporative light scattering detector(40 ℃,0.35 MPa) as used.Under this optimal condition,the linear relative coefficient of the standard curve is 0.998 and the recovery was in the range of 96.83%-101.58% with a relative standard deviation of 1.79%(n=6).
基金National Natural Science Foundations of China(No.81173024)to professor Qiang Fu is gratefully acknowledged.The authors also thank Xi’an Insti-tute of Food and Drug Control for providing the facilities and necessary equipments.
文摘A simple high-performance liquid chromatography(HPLC)method coupled with an evaporative light scattering detector(ELSD)was developed for the determination of azithromycin in raw materials and pharmaceutical formulations(injections,capsules and tablets)without any pretreatment or derivatization step.Azithromycin,degradation products and formulation ingredients were separated efficiently by using the mobile phase consisted of ammonium acetate(0.05 M,pH 8.0)and acetonitrile(60:40,v/v)in an isocratic mode at 0.8 ml/min flow rate.Parameters of ELSD were 60C for evaporation temperature and 50 psi for pressure of carrier gas(air).A logarithmic calibration curve was obtained from 50.93 to 509.30 mg/ml(r¼0.9996)for azithromycin,with the limit of detection(LOD)of 6.75 mg/ml(S/n¼3)and the limit of quantification of 22.50 mg/ml(S/n¼10).The developed method was validated and applied with satisfactory accuracy and precision for the determination of azithromycin in raw materials and pharmaceutical formulations(recovery 99e102%,RSD<1.2%,n¼3).No significant difference(t-test)was found between the results of the developed HPLCeELSD method and the HPLCeUV or microbiological method.
文摘The signal processing circuits of position sensitive detector(PSD) with alternating light source are presented.The measuring device of PSD with alternating light source can effectively eliminate the interference made by light noise signal.
基金supported by the National 973 Project Foundation of the Ministry of Science and Technology of China(No.2013CB834300)Strategic Pilot Science and Technology Project of the CAS(No.XDA10010000)the National Natural Science Foundation of China(No.116201 004)
文摘Linear alkylbenzene(LAB) will be used as solvent for the liquid scintillator in the central detector of Jiangmen Underground Neutrino Observatory. The sheer size of the detector imposes significant challenges and the necessity to further improve the optical transparency of high-quality LAB. In order to study high optical transparencies, we continuously improve our measurement setup and use monochromatic light to measure the attenuation lengths of LAB samples. Moreover, the effects of organic impurities on LAB samples are studied to understand their interaction mechanisms and further improve the optical transparency of LAB.
基金supported by the National Natural Science Foundation of China(Nos.11705103,12005120).
文摘As a proposed detector,the giant radio array for neutrino detection(GRAND)is primarily designed to discover and study the origin of ultra-high-energy cosmic rays,with ultra-high-energy neutrinos presenting the main method for detecting ultra-high-energy cosmic rays and their sources.The main principle is to detect radio emissions generated by ultra-high-energy neutrinos interacting with the atmosphere as they travel.GRAND is the largest neutrino detection array to be built in China.GRANDProto35,as the first stage of the GRAND experiment,is a coincidence array composed of radio antennas and a scintillation detector,the latter of which,as a traditional detector,is used to perform cross-validation with radio detection,thus verifying the radio detection efficiency and enabling study of the background exclusion method.This study focused on the implementation of the optimization simulation and experimental testing of the performance of the prototype scintillation detector used in GRANDProto35.A package based on GEANT4 was used to simulate the details of the scintillation detector,including the optical properties of its materials,the height of the light guide box,and position inhomogeneity.The surface of the scintillator and the reflective materials used in the detector was optimized,and the influence of light guide heights and position inhomogeneity on the energy and time resolutions of the detector was studied.According to the simulation study,the number of scintillator photoelectrons increased when changing from the polished surface to the ground surface,with the appropriate design height for the light guide box being 50 cm and the appropriate design area for the scintillator being 0.5 m^(2).The performance of the detector was tested in detail through a coincidence experiment,and the test results showed that the number of photoelectrons collected in the detector was$84 with a time resolution of~1 ns,indicating good performance.The simulation results were consistent with those obtained from the tests,which also verified the reliability of the simulation software.These studies provided a full understanding of the performance of the scintillation detector and guidance for the subsequent operation and analysis of the GRANDProto35 experimental array.
基金supported by the Major program of Natural Science Foundation of Shandong Province(No.ZR2020ZD30)the National Natural Science Foundation of China(Nos.11775133,U2167202,U1432119).
文摘A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels.
基金supported by the National Natural Science Foundation of China (Nos.12275007, U1867214, 11775004)the funding from the State Key Laboratory of Nuclear Physics and Technology,Peking University,China (No. NPT2021ZZ01)funding from heavy Ion Research Facility,Lanzhou,China (No. HIR2021PY002)。
文摘In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.
基金the National Natural Science Foundation of China(62274138,11904302)Science and Technology Plan Project in Fujian Province of China(2021H0011)+2 种基金Fujian Province Central Guidance Local Science and Technology Development Fund Project in 2022(2022L3058)Major Science and Technology Project of Xiamen,China(3502Z20191015)Foshan Hi-tech Zone High-tech Industrialization Entrepreneurial Team Special Guidance Fund in 2022(222019000131).
文摘The evolution of next-generation cellular networks is aimed at creating faster,more reliable solutions.Both the next-generation 6G network and the metaverse require high transmission speeds.Visible light communication(VLC)is deemed an important ancillary technology to wireless communication.It has shown potential for a wide range of applications in next-generation communication.Micro light-emitting diodes(μLEDs)are ideal light sources for high-speed VLC,owing to their high modulation bandwidths.In this review,an overview ofμLEDs for VLC is presented.Methods to improve the modulation bandwidth are discussed in terms of epitaxy optimization,crystal orientation,and active region structure.Moreover,electroluminescent white LEDs,photoluminescent white LEDs based on phosphor or quantum-dot color conversion,andμLED-based detectors for VLC are introduced.Finally,the latest high-speed VLC applications and the application prospects of VLC in 6G are introduced,including underwater VLC and artificial intelligence-based VLC systems.
基金supported by the Fundamental Research Funds for the Central Universities,China(Grant No.AUGA5710056414)the Program for Innovation Research of Science in Harbin Institute of Technology(Grant Nos.PIRS OF HIT A201412 and PIRS OF HIT Q201505)+3 种基金the National Natural Science Foundation of China(Grant No.11675046)the Doctoral Fund of the Ministry of Education of China(Grant No.20122302120003)the Natural Science Foundation of Heilongjiang Province of China(Grant No.A201303)the Postdoctoral Scientific Research Developmental Fund of Heilongjiang Province,China(Grant No.LBH-Q15060)
文摘Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments.
文摘This article demonstrates the fabrication of organic-based devices using a low-cost solution-processable technique.A blended heterojunction of chlorine substituted 2D-conjugated polymer PBDB-T-2Cl,and PC71BM supported nanocapsules hy-drate vanadium penta oxides(HVO)as hole transport layer(HTL)based photodetector fabricated on an ITO coated glass sub-strate under ambient condition.The device forms an excellent organic junction diode with a good rectification ratio of~200.The device has also shown excellent photodetection properties under photoconductive mode(at reverse bias)and zero bias for green light wavelength.A very high responsivity of~6500 mA/W and high external quantum efficiency(EQE)of 1400%have been reported in the article.The proposed organic photodetector exhibits an excellent response and recovery time of~30 and~40 ms,respectively.